• Title/Summary/Keyword: Time-efficiency

Search Result 11,896, Processing Time 0.043 seconds

Comparison Analysis of Time and Frequency Resource of Candidate Waveforms for 5G Mobile Communications (5세대 이동통신을 위한 후보 변조기술들의 시간과 주파수 자원 비교 분석)

  • An, Changyoung;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.11
    • /
    • pp.987-995
    • /
    • 2016
  • One of evaluation indicators of candidate waveforms for 5G mobile communication is spectral efficiency improvement by OOB(Out of Band) power reduction technique. In this paper, time-frequency resource allocation characteristic of UFMC(Universal Filtered Multi-Carrier), FBMC(Filter Bank Multi-Carrier), and W-OFDM(Weighted Orthogonal Frequency Division Multiplexing) system is evaluated and analyzed. As simulation results, spectral efficiency characteristic of these systems have been improved according to time resource allocation. In this paper, we can confirm that each system has similar time-frequency efficiency characteristic when the number of transmission bit is same and four symbols are transmitted with the linear system condition. Also, we can conclude that FBMC system has the lowest time-frequency resource efficiency under the nonlinear condition.

The Efficiency Analysis of Firms Having Established a Business Intelligence System Using DEA/Time-Window Analysis (DEA를 이용한 기업의 Business Intelligence 시스템 도입 효율성에 대한 비교 평가 연구)

  • Baek, Seong-Hyun;Park, Kwang-Ho;Kim, Tai-Young
    • Information Systems Review
    • /
    • v.17 no.3
    • /
    • pp.113-133
    • /
    • 2015
  • In this paper, DEA analysis is employed to compare and evaluate the relative efficiency of a business intelligence (BI) system among five industrial groups such as IT and financial services, electricity and electronics, energy and chemistry, automotive and heavy machinery, and food and apparel. Especially, this study has analyzed the improving tendency of relative efficiency of the industrial groups since they adopted the BI System using Time-Window Analysis. The research findings show that the energy and chemical industry group tends to be remarkably more efficient than the other groups and the electrical and electronic industry turns out to gradually improve their efficiency since the adoption of the BI system.

Development of Swimming Mechanism and Algorithm for Fish-Type Underwater Robot(1) (물고기형 수중로봇의 유영메커니즘 및 알고리즘 개발(1))

  • Ryuh, Young-Sun
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.1
    • /
    • pp.43-48
    • /
    • 2009
  • Generally, underwater vehicle type of propeller shows low efficiency about 50%-55%. However, the efficiency of swimming mechanism of a fish is 60%-70%, more efficient about 20% than screw propellers. Recently, research of underwater vehicle type of fish increase due to its good efficiency and is regarded as a typical bio-mimical robot. In this research, a new algorithm and mechanism that show low energy consumption imitating swimming mechanism of fish proposed increasing speed and running time in field trial.

  • PDF

Removal Characteristics of Hazard Organic Substances in the Multi-stage Ozone Contactor (다단오존접촉조에서 유해화학물질의 제거특성)

  • 박영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.41-49
    • /
    • 1999
  • The water treatment by was performed to remove VOC and organic substances in the multi-stage ozone contactor. Ozone is mainly utilized to change the chemical structures of organic substance, of which finally has the purpose to degrad them. The removal efficiency of VOC has 20~60% at the ozone concentration of 3 ppm, in case of trichloroethylene, its efficiency is reduced by 85% at the ozone contact time of 8 min. Design factors such as the number of stage, ozone concentration, zone contact time are determined for optimal treatment in the multi-stage contactor.

  • PDF

Development of a variable resistance-capacitance model with time delay for urea-SCR system

  • Feng, Tan;Lu, Lin
    • Environmental Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.155-161
    • /
    • 2015
  • Experimental research shows that the nitric oxides ($NO_X$) concentration track at the outlet of selective catalytic reduction (SCR) catalyst with a transient variation of Adblue dosage has a time delay and it features a characteristic of resistance-capacitance (RC). The phenomenon brings obstacles to get the simultaneously $NO_X$ expected to be reduced and equi-molar ammonia available to SCR reaction, which finally inhibits $NO_X$ conversion efficiency. Generally, engine loads change frequently, which triggers a rapid changing of Adblue dosage, and it aggravates the air quality that are caused by $NO_X$ emission and ammonia slip. In order to increase the conversion efficiency of $NO_X$ and avoid secondary pollution, the paper gives a comprehensive analysis of the SCR system and tells readers the key factors that affect time delay and RC characteristics. Accordingly, a map of time delay is established and a solution method for time constant and proportional constant is carried out. Finally, the paper accurately describes the input-output state relation of SCR system by using "variable RC model with time delay". The model can be used for a real-time correction of Adblue dosage, which can increase the conversion efficiency of $NO_X$ in SCR system and avoid secondary pollution forming. Obviously, the results of the work discover an avenue for the SCR control strategy.

Removal Characteristics of Nitrogen and Phosphorus in swine wastewater by Using Acetic acid on the SBR Process (SBR에서 아세트산을 이용한 양돈폐수의 질소·인 제거 특성)

  • Huh, Mock;Kang, Jin-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.1
    • /
    • pp.84-93
    • /
    • 2004
  • This study was performed : 1) to find the suitable HRT(hydralic retention time), 2) to evaluate the effects of the ratio of mixing/aeration time and injection time of external carbon source, for the removal of organics, nitrogen and phosphorus in swine wastewater by SBR(sequencing batch reactor process), which is one of the biological treatment process. The result of this study were summarized as follows : (1) As the ratio of mixing/aeration time was higher, $NH_4{^+}-N$ removal efficiency was increased and it was increased with increasing injection time of external carbon source because nitrification was affected by denitrification microbes propagation when injection time of external carbon soruce was shorted. T-N removal efficiency was increased with increasing the ratio of mixing/aeration time and injection time of external carbon source. (2) The T-P removal efficiency showed a great difference in each operating condition, and it was increased with increasing the ratio of mixing/aeration time increased and when the injection time of external carbon source was shorted because denitrification was done with effect by denitrification microbes propagation. (3) The highest removal efficiency of organic and nitrogen were obtained by the operating condition of Run 4-1(the ratio of mixing/aeration time : 16.5/5.5, injection time of external carbon source : 15hours) and T-P were obtained by the operation condition of Run 4-2(the ratio of mixing/aeration time : 16.5/5.5, injection time of external carbon source : 3hours), and efficiency(effluent concentration)of $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, T-N and T-P in the treated water was 96.1%, 87.7%, 90.6%, 86.6% and 84.5%, respectively.

  • PDF

studdyon the Field Efficiency of the Plowing Operation of the Power Tillers in accordance withthe Various Field Dimensions. (보장구획의 장단변화에 따른 경운기의 기종별 이경작업 효력에 관한 연구)

  • 최규홍;김종관
    • Journal of Biosystems Engineering
    • /
    • v.2 no.1
    • /
    • pp.49-54
    • /
    • 1977
  • In order to obtain the field efficiency of the power tiller plowing on the various size of and its length-width field tests were performed with 8ps.10ps. power tiller popularly used in the korean rural area, and Satoh 5ps. made in Japan, Land Master 5ps. made in England were tested to compare with the field efficiency of the above power tillers. The results obtained in this tests were as follows ; 1. In considering of the resting time and the refueling time and others, the field efficiency of Satoh was the highest among the power tillers as to be 80%, at the 8ps. power tiller 76.5%, at the 10ps. power tiller 79.3% and the lowest field efficiency was obtained at the Land Master as 75.7%. 2. The field efficiency of the each power tiller increased as the ratio of the length to width of the field was increased. 3. The increasing rate of field efficiency was much bigger in the below the ratio of 5 : 1 but at the upper ratio increased above, the ratio was nearly constant. 4. The field efficiency of the power tiller was higher at the smaller power tiller than the larger, except the Land Master , because of easily operating and turning of the power tiller by virtue of its lighter weight.

  • PDF

Comparison of Anaerobic Digestion Efficiency with Different Temperature of Food Wastes (음식물류폐기물의 성상별 온도변화에 따른 혐기성소화 효율 비교 연구)

  • Hwang, Kwanghyun;Kim, Dongik
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.4
    • /
    • pp.332-339
    • /
    • 2019
  • A comparative study on the anaerobic digestion efficiency according to the temperature change was conducted considering the characteristics of domestic food wastes with high water content of about 80 % or more. The substrate was tested for anaerobic digestion efficiency in two substrates, a liquid component separated naturally from food waste and food waste itself. In the anaerobic digestion experiments, the digestion efficiency was the highest at $55^{\circ}C$ (thermophilic temperature). However, the digestion efficiency at $45^{\circ}C$(middle high temperature) was lower than that at $35^{\circ}C$(mesophilic temperature). The comparison of general food wastes anaerobic digestion requiring 30 days of hydraulic retention time to the liquid component indicated a stable digestion efficiency even after 15 days of hydraulic retention time.In the experiments conducted on food waste, the digestion efficiency at $55^{\circ}C$ was higher than that at $35^{\circ}C$. When the food waste, especially the liquid component originating from food waste, is treated by anaerobic digestion method, the mesophilic temperature and thermophilic temperature conditions are more favorable in the digestion efficiency than the middle high temperature ($45^{\circ}C$). However, when applying thermophilic or mesophilic temperature anaerobic digestion process operation in the field, the amount of energy input should be considered.

A new proposal for the appropriate quality control of driven piles by using set values (최종관입량을 기준으로 한 합리적인 말뚝 시공관리 방안)

  • 이명환;홍헌성;김성회;전영석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03a
    • /
    • pp.51-63
    • /
    • 2000
  • Because of simplicity and easiness, dynamic pile driving formulae have long been used by most of the field engineers for pile quality control purposes. Yet their reliability have been repeatedly reported unsuitable and the results can lead to significant errors. According to the research results by the authors, the two most important sources of unreliability of dynamic pile driving formulae are uncertainty in the estimation of hammer efficiency and time dependent characteristics of pile bearing capacity. Based on this finding a new method is proposed. By using the actual value of hammer efficiency the pile bearing capacity at the time of driving could be reasonably estimated. By performing restrike test sometime after pile installation, time effect coefficient could be determined. The effectiveness of the proposed method was proven in the actual construction project.

  • PDF

Comparative Study on Disinfection Efficiency of Chlorine and Chloramine in the Distribution Systems (배·급수계통에서 유리염소와 클로라민의 소독효과에 관한 비교연구)

  • Choi, Yong-Il;Nam, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.82-88
    • /
    • 1999
  • This study was to evaluate disinfection efficiency of chlorine and chloramine as secondary disinfectants in the distribution systems. Indicator organism, HPC in the suspended and attached were measured for copper, galvanized steel, PVC, and carbon steel pipes. For suspended microorganism, the PVC pipe was markedly dense among the assessed pipe materials. The attached microorganism was markedly equivalent roughness of pipe materials. In copper and galvanized pipes, chloramine was more effective that free chlorine to disinfect suspended microorganism in the contact time of 2 hours. The contact time for the 99% inactivation of suspended microorganism by chloramine was longer than that of free chlorine. Regardless of pipe materials, chloramine was effective on both disinfection efficiency and 99% inactivation time for attached microorganism. In conclusion, chloramine which is good disinfectant for long contact time was recommended as secondary disinfectant in distribution system.

  • PDF