• Title/Summary/Keyword: Time-delayed Measurement

Search Result 67, Processing Time 0.022 seconds

A Study on method development of parameter estimation for real-time QRS detection (실시간 QRS 검출을 위한 파라미터 estimation 기법에 관한 연구)

  • Kim, Eung-Suk;Lee, Jeong-Whan;Yoon, Ji-Young;Lee, Myoung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.193-196
    • /
    • 1995
  • An algorithm using topological mapping has been developed for a real-time detection of the QRS complexes of ECG signals. As a measurement of QRS complex energy, we used topological mapping from one dimensional sampled ECG signals to two dimensional vectors. These vectors are reconstructed with the sampled ECG signals and the delayed ones. In this method, the detection rates of CRS complex vary with the parameters such as R-R interval average and peak detection threshold coefficient. We use mean, median, and iterative method to determint R-R interval average and peak estimation. We experiment on various value of search back coefficient and peak detection threshold coefficient to find optimal rule.

  • PDF

Integrated Navigation System Design of Electro-Optical Tracking System with Time-delay and Scale Factor Error Compensation

  • Son, Jae Hoon;Choi, Woojin;Oh, Sang Heon;Hwang, Dong-Hwan
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.2
    • /
    • pp.71-81
    • /
    • 2022
  • In order for electro-optical tracking system (EOTS) to have accurate target coordinate, accurate navigation results are required. If an integrated navigation system is configured using an inertial measurement unit (IMU) of EOTS and the vehicle's navigation results, navigation results with high rate can be obtained. Due to the time-delay of the navigation results of the vehicle in the EOTS and scale factor errors of the EOTS IMU in high-speed and high dynamic operation of the vehicle, it is much more difficult to have accurate navigation results. In this paper, an integrated navigation system of EOTS which compensates time-delay and scale factor error is proposed. The proposed integrated navigation system consists of vehicle's navigation system which provides time-delayed navigation results, an EOTS IMU, an inertial navigation system (INS), an augmented Kalman filter and integration Kalman filter. The augmented Kalman filter outputs navigation results, in which the time-delay of the vehicle's navigation results is compensated. The integration Kalman filter estimates position, velocity, attitude error of the EOTS INS and accelerometer bias, accelerometer scale factor error, gyro bias and gyro scale factor error from the difference between the output of the augmented Kalman filter and the navigation result of the EOTS INS. In order to check performance of the proposed integrated navigation system, simulations for output data of a measurement generator and land vehicle experiments were performed. The performance evaluation results show that the proposed integrated navigation system provides more accurate navigation results.

A Case Study on the Six Sigma Application to Reduce Waiting Day for Computed Tomography in the Radiology Department (영상의학과 전산화단층촬영 검사 대기일 단축을 위한 6-시그마 적용사례 연구)

  • Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.2
    • /
    • pp.225-230
    • /
    • 2010
  • The purpose of the study was to apply and to expand the six sigma to reduce waiting times for computed tomography (CT) examination which manipulated by the department of radiology. It was preceded by DMAIC (Define, Measure, Analyze, Improve, and Control). In the stage of definition, it wereselected for total 5 critical to quality (CTQ), which were the kindness, the waiting time, the examination explanation, the waiting day and the waiting stand environment, that increased the reserved time of CT examination. In the stage of measurement, the number of examinations and of reservation waiting days performed and resulted in final CTQ(Y) which measured each 1.68 and 1.85 sigma. In the stage of analysis, the examination concentrated on morning time, non-scheduled examination of the day, the delayed time of booking, frequent telephone contacting and equipment malfunction were determined as variable key causes. In the stage of improvement, it were performed with expansion of the examination in the morning time, integration of laboratories that used to in each steps, developing the ability of simultaneous booking schedule for the multiple examinations, developing program of examination request, and the customer management team operations. For the control, the number of examinations and reserved waiting days were measured each 3.14 and 1.13 sigma.

Hydrogen Jet Structure and Measurement of Local Equivalence Ratio by LIBs under the Different Injection Pressure (분사 압력에 따른 수소 제트의 형상과 LIBs를 적용한 국부 당량비 계측)

  • Lee, Sanguk;Kim, Jungho Justin;Bae, Choongsik
    • Journal of ILASS-Korea
    • /
    • v.27 no.2
    • /
    • pp.84-93
    • /
    • 2022
  • To implement carbon-neutrality in transportation sectors until 2050, hydrogen is considered a promising fuel for internal combustion engines because hydrogen does not contain carbon itself. Although hydrogen does not emit CO2 emission from its combustion process, the low energy density in a volume unit hinders the adoption of hydrogen. Therefore, the understanding of hydrogen jet behavior and measurement of equivalence ratio must be conducted to completely implement the high-pressure hydrogen direct injection. The main objective of this research is feasibility test of hydrogen local equivalence ratio measurement by laser-induced breakdown spectroscopy (LIBs). To visualize the macroscopic structure of hydrogen jet, high-speed schlieren imaging was conducted. Moreover, LIBs has been adopted to validate the feasibility of hydrogen local equivalence ratio measurement. The hydrogen injection pressure was varied from 4 MPa to 8 MPa and injected in a constant volume chamber where the ambient pressure was 0.5 MPa. The increased injection pressure extends the vertical penetration of hydrogen jet. Due to the higher momentum supply when the injection pressure is high, the hydrogen has easily diffused in all directions. As the laser trigger timing has delayed, the low hydrogen atomic emission was detected due to the longer mixture formation time. Based on equivalence ratio measurement results, LIBs could be applied as a methodology for hydrogen local equivalence ratio measurement.

Approach to the Children with Recurrent Infections (재발성 감염 질환의 접근 방법)

  • Lee, Jae Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.5
    • /
    • pp.461-468
    • /
    • 2005
  • The major function of immune system is to protect infections. The immune systems are composed of innate and adaptive immunity. In adaptive immunity, the cellular and humoral components interact each other. Neonates and infants are infected frequently, because immune systems are naive and easy to expose to infectious agents. The complete history and physical examination is essential to evaluate the child with recurrent infections. The environmental risk factors of recurrent infections are day care center, cigarette smoke, and air pollution. The underlying diseases such as immunodeficiency, autoimmune diseases, allergy, and disorders of anatomy or physiology increase the susceptibility to infections. In immunodeficiency, infections are characterized by severe, chronic, recurrent, and unusual microbial agents infection. The defects of antibody production are susceptible to sinopulmonary bacterial infections. T cells defects are vulerable to numerous organisms such as virus, fungi, bacteria and etc. The screening tests for immune functions are the quantitative and qualitative measurements of each immune components. A complete blood count with white blood cell, differential, and platelet provide quantitative informations of immune components. Total complement and immunoglobulin levels represent the humoral component. Antibody levels of previously injected vaccines also provide informations of the antigen specific antibody immune responses. T cell and subsets count is quantitative measurement of cell mediated immunity. Delayed hypersensitivity skin test is a crude measurement of T cell function. The long term outcome of children with recurrent infections is completely dependent on the underlying diseases, the initial time of diagnosis and therapy, continued management, and genetic counscelling.

Balanced Performance Measurement System for Strategic Learning (전략적 학습의 촉진을 위한.균형 성과측정시스템의 개발)

  • Min, Jae H;Lee, Young-Chan;Ha, Chang-Hoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.27 no.3
    • /
    • pp.93-114
    • /
    • 2002
  • This paper suggests a dynamic balanced scorecard (DBSC) model employing the concept of system dynamics (SD), which could overcome the limitations inherent in the conventional balanced scorecard (BSC) and facilitate strategic learning process in organizations. The BSC has been a successful framework for measuring an organization's performance in various Perspectives through translating an organization's vision and strategy into an interrelated set of key performance indicators and specific actions. The BSC, while having significant strengths over traditional performance measurement methods, however, has its own limitations, due to its static nature, such as overlooking two-way causation between performance Indicators and neglecting the impact of delayed feedback flowing from the adoption of new strategies or policy changes. To overcome these limitations, we employs SD, a methodology for understanding complex systems where dynamic feedback among the interrelated system components significantly impact on the system outcomes. The SD simulation model in the form of DBSC we suggest in this paper would serve as a useful strategic learning tool for facilitating an organization's communication process through various scenario analyses as well as predicting the dynamic behavior pattern of their key performance measures over a future time frame. For the demonstration purpose, we apply the DBSC model to Korea Coal Corporation (KoCoal ) BSC case.

A Study on the Application of Under Voltage Load Shedding Scheme in Line Contingency considering Motor Load (모터부하를 고려한 상정사고 발생 시 저전압 부하차단 적용 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • Failure of high-voltage transmission line, which is responsible for large-scale power transmission, can be reason for system voltage instability. There are many methods to prevent voltage instability like adjustment of equipment, the generator voltage setting, and load shedding. Among them, the load shedding, have a problem of economic loss and cascading effect to power system. Therefore, the execution of load shedding, amount and timing is very important. Conventionally, the load shedding setting is decided by the preformed simulation. Now, it is possible to monitor the power system in real time by the appearance of PMU(Phasor Measurement Unit). By this reason, some of research is performed about decentralized load shedding. The characteristics of the load can impact to amount and timing of decentralized load shedding. Especially, it is necessary to consider the influence of the induction motor loads. This paper review recent topic about under voltage load shedding and compare with decentralized load shedding scheme with conventional load shedding scheme. And simulations show the effectiveness of proposed method in resolving the delayed voltage recovery in the Korean Power System.

Effect of Storage Conditions on Graft of Polypropylene Non-woven Fabric Induced by Electron Beam (전자선 조사된 폴리프로필렌 부직포의 그라프트에 있어 보관조건이 미치는 영향)

  • Lee, Jin Young;Jeun, Joon-Pyo;Kang, Phil-Hyun
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.57-62
    • /
    • 2015
  • In this study, we fabricated effect of storage conditions on graft of polypropylene (PP) non-woven fabric induced by electron beam. The electron beam irradiations on PP non-woven fabric were carried out over a range of irradiation doses from 25 to 100 kGy to make free radicals on fabric surface. The radical measurement was established by electron spin resonance (ESR) for confirming the changes of the alkyl radical and peroxy radical according to effect of storage time, storage temperature and atmosphere. It was observed that the free radicals were increased with irradiation dose and decreased with storage time due to the continuous oxidation. However, the radical extinction was significantly delayed due to reduced mobility of radicals at extremely low temperature. The degree of graft based on the analysis of ESR was investigated. The conditions of graft reaction were set at a temperature: $60^{\circ}C$, reaction time: 6 hours and styrene monomer concentration: 20 wt%.

A Study on the Partial Discharge Wave Propagation along Stator Winding (회전기 권선의 펄스 전송특성 연구)

  • Kang, Dong-Sik;Sim, Woo-Yong;Hwang, Don-Ha;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.738-740
    • /
    • 2003
  • A lot of R&D on the diagnosis of stator winding insulation for large rotating machines has been carried out since the 1970s. The on-line partial discharge measurement has proved to be an effective technique in the evaluation of the state of stator insulation in high voltage rotating machines. It is well known that if the discharge pulses propagate through the winding conductor, they are attenuated and delayed. In the present study, to investigate the attenuation and the time delay of discharge pulses through the winding conductor, a series of tests were conducted using a model coils and slot. Thus it could be concluded that while the high frequency pulse propagates in radiation or end-winding coupling modes, the low frequency one does in a series mode through the coil conductor.

  • PDF

A Case of Postviral Gastroparesis in a 7-year-old Boy (바이러스 감염 후 발생한 위마비증 1례)

  • Kim, Eul-Soon;Kim, Jin-Suk;Park, Jae-Ock
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.5 no.1
    • /
    • pp.73-78
    • /
    • 2002
  • Gastroparesis is rare in children and is defined as delayed emptying of gastric contents into the duodenum without mechanical obstruction. We experienced a case of gastroparesis in a 7-year-old boy after a viral illness. He was admitted because of excessive abdominal bloating and diffuse abdominal pain, and was diagnosed by clinical manifestations and measurement of the gastric emtpyting time. He recovered after dietary management and with commbined medication of erythromycin and domperidone in 50 days of illness.

  • PDF