• Title/Summary/Keyword: Time-alignment

Search Result 715, Processing Time 0.024 seconds

Liquid crystal alignment and pretilt angle generation in the cell using linearly polarized UV light Irradiation on polymer surface (고분자막에 직선편광된 자외선 조사를 이용한 셀의 액정배향과 프리틸트각의 발생)

  • 서대식;이정호;이창훈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.259-262
    • /
    • 1998
  • The liquid crystal (LC) alignment and pretilt angle generation using photo-alignment method were investigated in this study. We obtained that the monodomain alignment of nematic(N) LC increases with increasing irradiation time in a cell with linearly polarized ultraviolet (LPUV) light irradiation on polyimide (Pl) surfaces. We consider that the monodomain alignment is able to be anisotropic dispersion force due to photo-depolymerization of polymer with LPUV light irradiation on Pl surface. Also, we observed that the uniform alignment of NLC is obtained in a cell with normally LPUV light irradiated on Pl surface at 30 min. and then oblique LPUV is secondly irradiated on Pl surfaces rotated by 90$^{\circ}$. The pretilt angle of NLC is generated about 1.5$^{\circ}$ with oblique angle 60$^{\circ}$.

  • PDF

DEVELOPMENT OF THE OPTICAL ALIGNMENT SYSTEM FOR FIB SECONDARY OF THE 1.8M OPTICAL TELESCOPE (보현산천문대 1.8m 광학 망원경 f/8 부경 광축 조정 장치 개발)

  • Yuk, In-Su;Jang, Jeong-Gyun;Seong, Hyeon-Cheol
    • Publications of The Korean Astronomical Society
    • /
    • v.11 no.1
    • /
    • pp.163-175
    • /
    • 1996
  • We propose the development and test result of new optical axis alignment system for the interchangeable F/8 secondary mirror of the BOAO 1.8m telescope system. Since the original system was not equipped with a suitable optical alignment facility, the whole alignment process was performed by hand. It was necessary at least three persons working more than 2 nights and the altitude of the telescope could not exceed 10 degrees, in such altitude the alignment quality was not so good by atmospheric effect. The new system adopts position readable motorized system and remote control operation by the computer installed in observation room, which reduces the number of workers to only one and eliminates the altitude restriction. The defocused CCD image pair obtained at higher altitude makes the aberration estimates more accurately and the number of required alignment loops is reduced from 10 to 4. The system has been installed on September 1, and performed alignment three times. The test results show that the system is stable and accurate, gives better optical performance of the telescope under F/8 focus. We hope to emphasize the fact that the new system will increase observation time of the telescope by about 20 nights per year assuming one alignment in every month.

  • PDF

Simplified Cubature Kalman Filter for Reducing the Computational Burden and Its Application to the Shipboard INS Transfer Alignment

  • Cho, Seong Yun;Ju, Ho Jin;Park, Chan Gook;Cho, Hyeonjin;Hwang, Junho
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.6 no.4
    • /
    • pp.167-179
    • /
    • 2017
  • In this paper, a simplified Cubature Kalman Filter (SCKF) is proposed to reduce the computation load of CKF, which is then used as a filter for transfer alignment of shipboard INS. CKF is an approximate Bayesian filter that can be applied to non-linear systems. When an initial estimation error is large, convergence characteristic of the CKF is more stable than that of the Extended Kalman Filter (EKF), and the reliability of the filter operation is more ensured than that of the Unscented Kalman Filter (UKF). However, when a system degree is large, the computation amount of CKF is also increased significantly, becoming a burden on real-time implementation in embedded systems. A simplified CKF is proposed to address this problem. This filter is applied to shipboard inertial navigation system (INS) transfer alignment. In the filter design for transfer alignment, measurement type and measurement update rate should be determined first, and if an application target is a ship, lever-arm problem, flexure of the hull, and asynchronous time problem between Master Inertial Navigation System (MINS) and Slave Inertial Navigation System (SINS) should be taken into consideration. In this paper, a transfer alignment filter based on SCKF is designed by considering these problems, and its performance is validated based on simulations.

Effects of alignment layer on pretilt generation and electrical characteristics for nematic liquid crystal by using photo-alignment techniques (광배향을 이용한 네마틱 액정의 프리틸트 발생과 전기적 특성에 관한 배향층의 효과)

  • 서대식;박태규;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.2
    • /
    • pp.151-156
    • /
    • 2000
  • Effects of alignment layers on pretilt nagle generation and electrical characteristics in nematic liquid crystal(NLC) by using photo-alignment techniques on polyimide PI) surface with side chain were studied. The generated pretilt angle of the NLC on rubbed PI surface with 1-layer is almost the same as that with the 2-layers. However, the generated pretilt angle of the NLC on photo-induced PI surface with 2-layers is larger than that with the 1-layer. The different mechanism of pretilt generation in NLC was observed on the rubbing and photo-alignment method. Therefore, the pretilt angle of the NLC on photo-induced PI surface is attributed to surface roughness due to photo-dissociation on the polymer with UV light irradiation on PI surface. We observed the same characteristics of voltage-transmittance (V-T) and response time for 1- and 2-layers on PI surface. Consequently, we sugest that the VHR of photo-aligned TN-LCD is higher than that of the rubbing-aligned TN-LCD.

  • PDF

The Effect of Shoulder Stabilization Exercise through Visit Rehabilitation on Muscle Activity and Postural Alignment, Self-Efficacy in Rural Elderly People with Round Shoulders

  • Kim, Yong-Nam;Kim, Jae-Woon
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.3
    • /
    • pp.148-154
    • /
    • 2021
  • Purpose: This study covered the effect of shoulder stabilization exercise on muscle activity, postural alignment and self-efficacy of the elderly people with round shoulders by visiting village hall in rural area. Methods: 40 elderly people with round shoulders were recruited for this study (experimental group: 20 subjects and control group: 20 subjects). The experimental group was asked to perform shoulder stabilization exercise 60 minutes per one time for 8 weeks and three times in a week and the control group was asked to receive education related to pain management for the initial one time. Before and after the experiment, we measured the subjects' muscle activity of upper trapezius, serratus anterior, infraspinatus, pectoralis major and the lower trapezius, then postural alignment of craniovertebral angle and round shoulder posture. In addition, self-efficacy is measured through the questionnaire. Results: Compared to the control group, the experimental group showed significant differences in the muscle activity of all muscles, posture alignment of the craniovertebral angle. round shoulder posture, and improvement of self-efficacy. Conclusion: We found that shoulder stabilization exercise is effective in muscle activity, postural alignment and self-efficacy of the elderly people through visit-rehabilitation service. This study can be used for improving the physical and mental abilities through active visit-rehabilitation service for areas where have poor medical benefits. It is considered that systematic visit rehabilitation service should have institutional framework ultimately.

Comparison of Muscle Performance of the Lumbar Region and Head Alignment According to the Length of Sitting Time

  • Park, Yong-Nam;Bae, Young-Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.6
    • /
    • pp.386-392
    • /
    • 2013
  • Purpose: This study aimed to verify the impact of the time that the sitting posture is maintained on changes in muscle performance and head alignment. Methods: The subjects of this study were healthy adults aged between 20 and 30 years. Ninety-three subjects participated in this study (male: 57, female: 36). The subjects were divided into a one-hour group, a two-hour group, and a three-hour group. All the subjects adjusted the height of their chair to a comfortable position and then seat for one, two, or over three hours. Both prior to and after the experiment, the muscle performance (muscle strength, endurance, and flexibility) of the subjects was measured. Results: In the 2-hours and 3-hour group, muscle strength, flexibility and endurance reduced significantly before and after the study, and the head alignment significantly changed. Conclusion: Thease findings showed that sitting continuously for longer than two hours decreases muscle strength, endurance, and flexibility. A flexed posture affects the muscle performance of the lumbar region and may result in problematic postures, such as a forward head position.

A Simulation Technique of the Shipboard INS Transfer Alignment Environments using Hardware-In-the-Loop Simulation (HILS를 이용한 함정의 관성항법장치 전달정렬 환경 모의 기법)

  • Kim, Woon-Sik;Yang, Tae-Soo;Kim, Sang-Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.181-188
    • /
    • 2011
  • A simulation technique, which simulate dynamic motion and communication environments of ship in the lab, is needed in order to reduce the testing cost when we evaluate the transfer alignment performance of shipboard INS. Hardware-In-the-Loop Simulation(HILS) can be used as an effective test method for those system because it can provide flexible and realistic simulation environments, various test scenario, and repeated test environment in the lab without additional cost and person. This paper presents the methods for implementing the real time HILS environment for testing transfer alignment performance of shipboard INS. It includes real time executive for controlling realtime simulation and calculating the ship motion, communication method for interfacing between the systems, and coordinate transformation method for converting real ship coordinate attitude data to lab coordinate attitude data.

Liquid crystal alignment effects for the photo-aligned VA-LCD on the photo-polymer

  • Hwang, Jeoung-Yeon;Seo, Dae-Shik;Hahn, Eun-Joo;Kim, Jae-Hyung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.10-13
    • /
    • 2000
  • In this study the new photo-alignment material copoly(PM4Ch-ChMa)(copoly (poly (4-methancryloyloxy)chalcone-cholesteryl methacry late)) was synthesized, Also, the liquid crystal (LC) aligning capabilities and the electro-optical(EO) characteristics for the photo-aligned vertical-aligned(VA)-LC display(LCD) were studied. The monodomain alignment of the NLC for the photo-aligned VA-LCD by linearly polarized UB exposure on the Photo-dimerized copoly(PM4Ch-ChMA) surface was observed,. Excellent Voltage-transmittance characteristics for the VA-LCD photo-aligned by polarized UV exposure on the copoly (PM4Ch-ChMA) surfaces for 1 min was achieved. The response time of the VA-LCD photo-aligned by polarized UV exposure on the copoly (PM4Ch-ChMA) surfaces for 1 min was 39.3 ms, We suggest that the photo-dimerized chacone group increased with increasing UV exposure time, which then contributes to a low response time of the photo-aligned VA-LCD on the copoly (PM4Ch-ChMA) surfaces.

  • PDF

Effects of Roscovitine on Nuclear Maturation, Spindle Configuration, and Chromosome Alignment in Porcine Oocytes

  • Park, Sang-Hyoun;Yu, Il-Jeoung
    • Journal of Embryo Transfer
    • /
    • v.25 no.4
    • /
    • pp.251-258
    • /
    • 2010
  • In the present study, effects of concentration and time of culture in presence of roscovitine on nuclear maturation and meiotic spindle configuration, chromosomal alignment were examined in porcine oocytes. In experiment 1, porcine cumulus oocyte complexes (COCs) were cultured at $39^{\circ}C$ in a 5% $CO_2$ atmosphere in North Carolina State University 23 (NCSU-23) supplemented with 25, 50, 75 or $100\;{\mu}M$ roscovitine for 22 h and then were cultured for additional 22 h after removal of roscovitine. Nuclear maturation and morphology of the meiotic spindle and chromosomal alignment were examined to determine the optimal concentration of roscovitine in oocyte maturation. In experiment 2, COCs were cultured in NCSU-23 supplemented with $50\;{\mu}M$ roscovitine for 17, 20, 27 or 42 h and then an additional 22 h without roscovitine was followed to determine the optimal time of culture. The optimal concentration of roscovitine to arrest and resume meiosis of porcine oocyte was $50\;{\mu}M$ by examining nuclear status (p<0.05) and normal spindle and chromosome configuration. The optimal time of culture in presence of roscovitine to arrest meiosis of porcine oocyte was 17 h (p<0.05), although MII rates and normal morphology of the meiotic spindle and chromosomal alignment were not significantly different among various times of culture. In conclusion, the optimal concentration and time of culture in presence of roscovitine to arrest porcine oocytes are $50\;{\mu}M$ and 17 h, respectively.

Effect of Electric field on an Injection Velocity in a Vertically Aligned Nematic Liquid Crystal (수직배향 네마틱 액정셀에서의 주입속도에 미치는 전기장 효과)

  • Jeon, Yeon-Mun;Kim, Sang-Gyun;Kim, Youn-Sik;An, Myeong-Hwan;Lee, Seung-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.7
    • /
    • pp.695-699
    • /
    • 2006
  • Injection time of liquid crystal (LC) by capillary action in a vertically aligned (VA) nematic LC cell takes longer than that in a homogeneously aligned (HA) LC cell because Miesowicz viscosity in the former is bigger than that in the latter. To reduce liquid crystal injection time in the VA cell, we applied vertical electric field while injecting so that the orientation of LC molecules is changed from vertical alignment to homogeneous alignment. Consequently, the injection speed is improved by 25 % when compared with the cell without an applied field.