• Title/Summary/Keyword: Time window

Search Result 1,449, Processing Time 0.027 seconds

Methodology for Estimating Highway Traffic Performance Based on Origin/Destination Traffic Volume (기종점통행량(O/D) 기반의 고속도로 통행실적 산정 방법론 연구)

  • Howon Lee;Jungyeol Hong;Yoonhyuk Choi
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.2
    • /
    • pp.119-131
    • /
    • 2024
  • Understanding accurate traffic performance is crucial for ensuring efficient highway operation and providing a sustainable mobility environment. On the other hand, an immediate and precise estimation of highway traffic performance faces challenges because of infrastructure and technological constraints, data processing complexities, and limitations in using integrated big data. This paper introduces a framework for estimating traffic performance by analyzing real-time data sourced from toll collection systems and dedicated short-range communications used on highways. In particular, this study addresses the data errors arising from segmented information in data, influencing the individual travel trajectories of vehicles and establishing a more reliable Origin-Destination (OD) framework. The study revealed the necessity of trip linkage for accurate estimations when consecutive segments of individual vehicle travel within the OD occur within a 20-minute window. By linking these trip ODs, the daily average highway traffic performance for South Korea was estimated to be248,624 thousand vehicle kilometers per day. This value shows an increase of approximately 458 thousand vehicle kilometers per day compared to the 248,166 thousand vehicle kilometers per day reported in the highway operations manual. This outcome highlights the potential for supplementing previously omitted traffic performance data through the methodology proposed in this study.

A Study on the Arrangements of YangjinDang in Sang-ju Foundation by Date on the Excavation and Jungsuki (중수기 및 발굴 자료로 본 상주 양진당의 배치에 관한 연구)

  • Kim, Chan-Yeung;Chung, Myung-Sup
    • Journal of architectural history
    • /
    • v.20 no.4
    • /
    • pp.61-80
    • /
    • 2011
  • This study estimated the prototype of Yangjindang at the time of its foundation by putting together the literature and discovered data and historical research on family related to Sangju Yangjindang, and looked at its architectural characteristics. These are summarized as follows: First, Yangjindang is an office building which was completed in three years [1629] after its start of construction when Keomgan Jojeong was at the age of 72 [1626] in his latter days and it was used for performing ancestral rites for Jojeong's forefathers of the head family of Pungyang Jo by family origin. Yangjindang was founded as a base of utopia for putting ancestral rites & commemoration, harmoniousness of a tribe, and educational idea into practice together with Ojakdang. Such a movement can be judged to interpret and apply the circumstances of the times realistically and flexibly where they tried to pursue the promotion of Confucianism & studies of the proprieties as well as the consciousness of practice, and to bring a tribe into harmony after the war through the retirement of Toegye School. Second, it is located at a topographically ideal spot on the edge of the Jangcheon-a tributary of Nakdong with a good physiology and landscape and its location was also the lot for a house of Jojeong's ancestor, which was burned down by war. Behind such a location and planning of Yangjindang, it is presumed, though not certain that it was modelled after Naeap village at Andong- Jojeong's parents-in-low's home. Third, as for its foundation size, it's a head house as much as about more than 100-kan, and its structure is composed of Samyo, Bonche, and Yangjindang. In addition, arrangements of buildings and its composition system and renovation procedures followed Chu-tzu Garyoe. Composition of Samyo can be restored to Yangjindang, Jugo, Woesammun, and Samyo; however, there has been no case of existence in case of Jugo building composition & arrangement takes on an aspect of a compromise between Gamyojido and Sandangjido of Garoe, which seems to be the result from flexibly interpreting and applying the rituals and studies of the proprieties of Toegye School in keeping with locational topography and realistic circumstances while making it a principle for them to observe by Toegye School. There exists a difference between Bonche and its counterpart of the upper class housing at Sangju district in that Bonche[main building] is a squre-shaped 'Ttuljip' typical of Andong setting a family ancestral ritual as a main function. Fourth, there existed a lot of hardships in raising money to cover repairs in time of doing repairs to this structure after 180 years since its establishment. In case of the repair work on Bonche, the level of renovation was limited to the replacement of old materials for rafters, doorpost, roof members and railings with new materials, together with partial alterations in case of window system. It is estimated that Yangjindang was renovated in 1808, and afterwards it was renamed Okryujeong after being re-built at another site. Through the repairs, the floor was expanded for the clan's meeting, and angle rafters and roof members were mended as well. Especially, the plane and structure of Okryujeong which was re-built at another site are expected to give clues to its restoration due to the resemblance to original appearance of Yangjindang at the time of its renovation in 1808.

Effectiveness of Real-time Oxygen Control in Fresh Produce Container Equipped with Gas-diffusion Tube (기체확산 튜브 부착 신선 농산물 용기에서의 실시간 산소농도 제어의 효과)

  • Jo, Yun Hee;An, Duck Soon;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.3
    • /
    • pp.119-123
    • /
    • 2013
  • Simplified control logic was devised to fabricate and operate the modified atmosphere (MA) container of fresh produce equipped with gas-diffusion tube whose opening/closing was controlled in response to real time $O_2$ concentration. This is a simplified ramification of the previously developed control logic using both $O_2$ and $CO_2$ concentrations ([$O_2$] & [$CO_2$]). The developed logic was applied to and tested by a container system filled with spinach at $10^{\circ}C$ having optimum MA window of [$O_2$] of 7~10% and [$CO_2$] of 5~10%. It was shown that setting the proper on-off limit (11%) for $O_2$ control based on the assumed relationship $[O_2]+[CO_2]$=21% could attain the desired $CO_2$ concentration just below the upper tolerance limit ($[CO_2]_H$, 10%). The $O_2$ control point can be the lower tolerance limit or adjusted one (21-$[CO_2]_H$) depending on the commodity's MA requirement. The developed logic using single $O_2$ sensor could attain the equilibrated [$O_2$] of 11% with [$CO_2$] of 8~9% which was desired and similar to that of its predecessor ([$O_2$] of 9~10% with [$CO_2$] of 10%) using both $O_2$ and $CO_2$ sensors. Both MA containers (one only with single $O_2$ sensor control and one with $O_2$ and $CO_2$ sensors) could also keep the spinach quality without significant difference between them, but significantly better than perforated control package of air.

  • PDF

The Signaling Effect of Stock Repurchase on Equity Offerings in Korea (자기주식매입의 유상증자에 대한 신호효과)

  • Park, Young-Kyu
    • The Korean Journal of Financial Management
    • /
    • v.25 no.1
    • /
    • pp.51-84
    • /
    • 2008
  • We investigate the signaling effect of repurchase preceding new equity issue using Korean data. In a short time span, firms announce stock repurchases and equity offerings. The proximity of two events in Korean firms indicates that those are not independent of each other. In this paper, we test the signaling effect of repurchase on equity offerings on the two measures. One is announcement effect, which is measured as CAR(0, +2). The other is the effectiveness which is measured as CAR(0, +30) because the price movement during this window influences on the price of new issues. Previous studies that stock repurchase convey positive signal to equity offerings-Billet and Xue(2004) and Jung(2004)-construct sample without the limit of time interval between two events. This causes the unclear relation between those because of the long time interval. In this study we consider only samples of being within one year each other to reduce this problem and clarify the signal of repurchase on equity offerings. Korean firms are allowed to repurchase own shares with two different method. One is direct repurchase as same as open market repurchase. The other is stock stabilization fund and stock trust fund which trust company or bank buy and sell their shares on the behalf of firms. Generally, the striking different characteristic between direct repurchase and indirect repurchase is following. Direct repurchase is applied by more strict regulation than indirect repurchase. Therefore, the direct repurchase is more informative signal to the equity offering than the indirect repurchase. We construct two sample firms- firms with direct repurchase preceding-equity offerings and indirect repurchase-preceding equity offering, and one control firms-equity offerings only firms-to investigate the announcement effect and the effectiveness of repurchases. Our findings are as follows. Direct repurchase favorably affect the price of new issues favorably. CAR(0, +2) of firms with direct repurchase is not different from that of equity offerings only firms but CAR(0, +30) is higher than that of equity offerings only firms. For firms with indirect repurchase and equity offerings, Both the announcement effect and the effectiveness does not exist. Jung(2004) suggest the possibilities of how indirect stock repurchase can be regarded as one of unfair trading practices on based on the survey results that financial managers of some of KSE listed firms have been asked of their opinion on the likelihood of the stock repurchase being used in unfair trading. This is not objective empirical evidence but opinion of financial managers. To investigate whether firms announce false signal before equity offerings to boost the price of new issues, we calculate the long-run performance following equity offerings. If firms have announced repurchase to boost the price of new issues intentionally, they would undergo the severe underperformance. The empirical results do not show the severer underperformance of both sample firms than equity offerings only firms. The suggestion of false signaling of repurchase preceding equity offerings is not supported by our evidence.

  • PDF

Closure of Atrial Septal Defects through a Video-assisted Mini-thoracotomy (흉강경하 최소절개를 이용한 심방중격결손의 폐쇄)

  • Min, Ho-Ki;Yang, Ji-Hyuk;Jun, Tae-Gook;Park, Pyo-Won;Choi, Seon-Uoo;Park, Seung-Woo;Min, Sun-Kyung;Lee, Jae-Jin
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.568-572
    • /
    • 2008
  • Background: Minimally invasive surgery is currently popular, but this has been applied very sparingly to cardiac surgery because of some limitations. Our study evaluated the safety and efficacy of atrial septal defect (ASD) closure through a video-assisted mini-thoracotomy. Material and Method: Fifteen patients were analyzed. Their mean age was $31{\pm}6$ years. The mean ASD size was $24{\pm}5mm$ and there were 3 cases of significant tricuspid regurgitation. The working window was made through the right 4th intercostal space via a $4{\sim}5cm$ inframammary skin incision, CPB was conducted with performing peripheral cannulation. After cardioplegic arrest, the ASDs were closed with a patch (n=11) or direct sutures (n=4), and the procedures were assisted by using a thoracoscope. There were 3 cases of tricuspid repair and 1 case of mitral valve repair. The mean CPB time and aortic occlusion time were $160{\pm}47\;and\;70{\pm}26 $minutes, respectively. Result: There was no mortality, but there were 3 minor complications (one pneumothorax, one wound dehiscence and one arrhythmia). The mean hospital stay was $5.9{\pm}1.8$ days. The mean follow-up duration was $10.7{\pm}6.4$ months. The follow-up echocardiogram noted no residual ASD or significant tricuspid regurgitation. Three patients suffered from pain or numbness. Conclusion: This study showed satisfactory clinical and cosmetic results. Although the operative time is still too long, more experience and specialized equipment would make this technique a good option for treating ASD.

A Basic Study for the Retrieval of Surface Temperature from Single Channel Middle-infrared Images (단일 밴드 중적외선 영상으로부터 표면온도 추정을 위한 기초연구)

  • Park, Wook;Lee, Yoon-Kyung;Won, Joong-Sun;Lee, Seung-Geun;Kim, Jong-Min
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.2
    • /
    • pp.189-194
    • /
    • 2008
  • Middle-infrared (MIR) spectral region between 3.0 and $5.0\;{\mu}m$ in wavelength is useful for observing high temperature events such as volcanic activities and forest fire. However, atmospheric effects and sun irradiance in day time has not been well studied for this MIR spectral band. The objectives of this basic study is to evaluate atmospheric effects and eventually to estimate surface temperature from a single channel MIR image, although a typical approach utilize split-window method using more than two channels. Several parameters are involved for the correction including various atmospheric data and sun-irradiance at the area of interest. To evaluate the effect of sun irradiance, MODIS MIR images acquired in day and night times were used for comparison. Atmospheric parameters were modeled by MODTRAN, and applied to a radiative transfer model for estimating the sea surface temperature. MODIS Sea Surface Temperature algorithm based upon multi-channel observation was performed in comparison with results from the radiative transfer model from a single channel. Temperature difference of the two methods was $0.89{\pm}0.54^{\circ}C$ and $1.25{\pm}0.41^{\circ}C$ from the day-time and night-time images, respectively. It is also shown that the emissivity effect has by more largely influenced on the estimated temperature than atmospheric effects. Although the test results encourage using a single channel MR observation, it must be noted that the results were obtained from water body not from land surface. Because emissivity greatly varies on land, it is very difficult to retrieval land surface temperature from a single channel MIR data.

A Deep Learning Based Approach to Recognizing Accompanying Status of Smartphone Users Using Multimodal Data (스마트폰 다종 데이터를 활용한 딥러닝 기반의 사용자 동행 상태 인식)

  • Kim, Kilho;Choi, Sangwoo;Chae, Moon-jung;Park, Heewoong;Lee, Jaehong;Park, Jonghun
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.1
    • /
    • pp.163-177
    • /
    • 2019
  • As smartphones are getting widely used, human activity recognition (HAR) tasks for recognizing personal activities of smartphone users with multimodal data have been actively studied recently. The research area is expanding from the recognition of the simple body movement of an individual user to the recognition of low-level behavior and high-level behavior. However, HAR tasks for recognizing interaction behavior with other people, such as whether the user is accompanying or communicating with someone else, have gotten less attention so far. And previous research for recognizing interaction behavior has usually depended on audio, Bluetooth, and Wi-Fi sensors, which are vulnerable to privacy issues and require much time to collect enough data. Whereas physical sensors including accelerometer, magnetic field and gyroscope sensors are less vulnerable to privacy issues and can collect a large amount of data within a short time. In this paper, a method for detecting accompanying status based on deep learning model by only using multimodal physical sensor data, such as an accelerometer, magnetic field and gyroscope, was proposed. The accompanying status was defined as a redefinition of a part of the user interaction behavior, including whether the user is accompanying with an acquaintance at a close distance and the user is actively communicating with the acquaintance. A framework based on convolutional neural networks (CNN) and long short-term memory (LSTM) recurrent networks for classifying accompanying and conversation was proposed. First, a data preprocessing method which consists of time synchronization of multimodal data from different physical sensors, data normalization and sequence data generation was introduced. We applied the nearest interpolation to synchronize the time of collected data from different sensors. Normalization was performed for each x, y, z axis value of the sensor data, and the sequence data was generated according to the sliding window method. Then, the sequence data became the input for CNN, where feature maps representing local dependencies of the original sequence are extracted. The CNN consisted of 3 convolutional layers and did not have a pooling layer to maintain the temporal information of the sequence data. Next, LSTM recurrent networks received the feature maps, learned long-term dependencies from them and extracted features. The LSTM recurrent networks consisted of two layers, each with 128 cells. Finally, the extracted features were used for classification by softmax classifier. The loss function of the model was cross entropy function and the weights of the model were randomly initialized on a normal distribution with an average of 0 and a standard deviation of 0.1. The model was trained using adaptive moment estimation (ADAM) optimization algorithm and the mini batch size was set to 128. We applied dropout to input values of the LSTM recurrent networks to prevent overfitting. The initial learning rate was set to 0.001, and it decreased exponentially by 0.99 at the end of each epoch training. An Android smartphone application was developed and released to collect data. We collected smartphone data for a total of 18 subjects. Using the data, the model classified accompanying and conversation by 98.74% and 98.83% accuracy each. Both the F1 score and accuracy of the model were higher than the F1 score and accuracy of the majority vote classifier, support vector machine, and deep recurrent neural network. In the future research, we will focus on more rigorous multimodal sensor data synchronization methods that minimize the time stamp differences. In addition, we will further study transfer learning method that enables transfer of trained models tailored to the training data to the evaluation data that follows a different distribution. It is expected that a model capable of exhibiting robust recognition performance against changes in data that is not considered in the model learning stage will be obtained.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

Monitoring North Korea Nuclear Tests: Comparison of 1st and 2nd Tests (북한 핵실험 모니터링 : 1, 2차 비교)

  • Chi, Heon-Cheol;Park, Jung-Ho;Kim, Geun-Young;Che, Il-Young;Sheen, Dong-Hoon;Shin, Jin-Soo;Cho, Chang-Soo;Lee, Hee-Il
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.243-248
    • /
    • 2010
  • Two suspicious events, which were claimed as underground nuclear tests by North Korea, were detected in the northern Korean Peninsula on October 9, 2006 and May 25, 2009. The KIGAM and Korea-China Joint seismic stations are distributed uniformly along the boundaries between North Korea and adjacent countries. In this study, the data from broadband stations with the distance of 200 to 550 km from the test site are used to analyze and compare two nuclear tests of North Korea. By comparing the time differences of the Pn-wave arrival times of 1st and 2nd tests at multiple stations, the relative locations of two test sites could be calculated precisely. From the geometrical calculation with the velocity of Pn wave $V_{Pn}$ = 8 km/s, the 2nd test site is estimated to move in the WNW direction from 1st one with the distance of 2 km. Body wave magnitude, mb of the 2nd test, which was announced officially as the network average of 4.5, varies widely with the directional location of stations from 4.1 to 5.2. The magnitude obtained from Lg wave, $m_b$(Lg), shows less variation between 4.3 to 4.7 with the average of 4.6. The moving-window spectra of time traces of 1st and 2nd tests show very similar pattern with different scale level. In addition, the corner frequencies of P wave of 1st and 2nd tests at each station show no or negligible difference. This indicates the burial depths of two tests might be very similar. The relative yield amount of the 2nd test is estimated 8 times larger than that of the 1st from the weighted average of ground-velocity amplitude ratios.