• Title/Summary/Keyword: Time temperature shift technique

Search Result 15, Processing Time 0.029 seconds

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

Multiscale Modeling and Simulation of Water Gas Shift Reactor (Water Gas Shift Reactor의 Multiscale 모델링 및 모사)

  • Lee, Ukjune;Kim, Kihyun;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.582-590
    • /
    • 2007
  • In view of the analysis of the phenomena and the prediction of the performance, mathematical modelling and simulation of a high temperature pilot reactor for water gas shift reaction (WGSR) has been carried out. Multiscale simulation incorporated computational fluid dynamics (CFD) technique, which has the capability to deal with the reactor shape, fluid and energy transport with extensive degree of accuracy, and process modeling technique, which, in turn is responsible for reaction kinetics and mass transport. This research employed multiscale simulation and the results were compared with those from process simulation. From multiscale simulation, the maximum conversion of was predicted approximately 0.85 and the maximum temperature at the reactor was calculated 720 K, resulting from the heat of reaction. Dynamic simulation was also performed for the time transient profile of temperature, conversion, etc. Considering the results, it is concluded that multiscale simulation is a safe and accurate technique to predict reactor behaviors, and consequently will be available for the design of commercial size chemical reactors as well as other commercial unit operations.

Time-Temperature Superposition Behavior for Accelerated Fatigue Lifetime Testing of Polycarbonate(PC) (폴리카보네이트(PC)의 가속 피로수명 시험을 위한 시간-온도 호환성)

  • Kim Gyu-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.8 s.251
    • /
    • pp.976-984
    • /
    • 2006
  • Time-temperature superposition has been studied to determine the long-term fatigue life over millions of cycles for glassy polymers. π le superposition is supposed to make an accelerated lifetime testing (ALT) technique possible. Dog-bone shaped specimens made of carbon filled Polycarbonate (PC) were tested under fatigue, based on the stress-lifetime approach (S-N curve). Fatigue-induced localized yield-like deformation is considered as the defect leading to fatigue and its evolution behavior is characterized by a modified energy activation model in which temperature is considered as fatigue acceleration factor. This model allows the reduced time concept to account for effects of different temperature in short-term fatigue data to determine long-term fatigue life through the use of time-temperature superposition that is applicable under a low frequency and isothermal conditions. The experimental results validated that the proposed technique could be a possible method for accelerated lifetime testing (ALT) of time-dependent polymeric materials.

Measurement of Vibration Mode Shapes Using Time Average ESPI (시간 평균 ESPI를 이용한 진동 물체의 모우드 형태의 계측)

  • Kang, Young-June;Choi, Jang-Seob
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.2
    • /
    • pp.84-93
    • /
    • 1996
  • Non-destructive inspection techniques using laser have been broading their application areas as well as growing their measurement skills together with the rapid development of circumferential technology like fiber optics, computer and image processing. The ESPI technique is already on the stage of on-line testing with commercial products in developed country nations. Especially, this technique is expected to be applied to the nuclear industry, automobile and aerospace because it is proper for the vibration measurement and it can be applied to objects of a high temperature. This paper describes the use of the ESPI system for measuring vibration patterns on the reflecting objects. Using this system, high-quality Jo fringes for identifying mode shapes are displayed. A bias vibration is introduced into the reference beam to shift the Jo fringes so that fringe shift algorithms can be used to determine vibration amplitude. Using this method, amplitude fields for vibrating objects were obtained directly from the time-average interferograms recorded by the ESPI system.

  • PDF

Effect of Shift Interval for the Clinical Nurse on the Circadian Rhythm (임상 간호사의 교대근무 기간이 circadian rhythm 변화에 미치는 영향)

  • 황애란;정현숙;임영신;이혜원;김조자
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.2
    • /
    • pp.129-149
    • /
    • 1991
  • Circadian rhythm is entrained in the 24-hour time interval by periodic factors in the environment, known as zeitgeber. But most rotating work schedules are outside the range of the entrainment of the pacemaker timing the human circadian sleep - wake cycle. It has been postulated that physiological and emotional disturbances occur in most human functions when the circadian rhythm is disturbed. So application of circadian principles to the design of shift schedules can aid in maintaining the temporal integrity of the circadian system and thereby minimize for the shift worker any detrimental consequences of circadian disruption. This study was a quasi-experimental study to test the effect of shift intervals for the clinical nurse on the circadian rhythm. Twenty nurses newly employed in general units of two hospitals were selected as an experimental group and twelve college nursing students as a control group. Both groups were selected according to an established criteria using a purposive sampling technique. Ten subjects were assigned to a weekly shift group and another ten to a biweekly shift group engaged in a semi -continuous shift schedule(sunday off) with a backward direction, that is, morning -evening - night shift. The control group worked a morning shift for 42 days. Oral temperature rhythm, waking tim, sleep - wake cycle, fatigue, and mental performance were measured during the experimental period. The data collection period was from April 30, 1990 to June 10, 1990. MANOVA, paired t-test, ANOVA, and Student Newman Keuls method were used for statistical analysis. The results are summarized as follows. 1. Phase delay in the acrophase of temperature rhythm was shown according to the backward rotating shift. A complete adaptation to work on the night shift was achieved between the sixth and ninth day of the night shift. 2. There was no difference in either waking time or sleep- wake cycle according to the duration of the working day for every shift group. Significant difference was found in the waking time and the sleep -wake cycle for subjects on the morning, evening, and night shift in both of the shift groups(weekly shift group : λ=0.121, p<0.01, λ=0.112, p<0.01, biweekly shift group : λ=0.116, p<0.01, λ=0.084, p<0.01). 3. There was no difference in fatigue between the first working day and the last working day for the control group and for the biweekly shift group. In the weekly shift group, physical fatigue was significantly different for the first day and the sixth day of the night shift(t=-2.28, p<0.05). Physical fatigue and total fatigue on the first day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=5.79, p<0.01, F=4.56, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05), Physical fatigue, neurosensory fatigue and total fatigue on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=12.65, p<0.01, F=7.77, p<0.01, F=9.68, p<0.01). There was a significant difference between the shift groups and the control group(p<0.05). 4. No difference in mental performance was seen between the first day and the last day of work in each case. An arithmatic test on the first day of the night shift revealed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.79, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05) . The digital symbol substitution test and the arithmetic test on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.68, p<0.05, F=5.55, p<0.01), and both showed a significant difference between the shift groups and the control group(p<0.05). Accordingly, this study showed that during night duty, the waking time, sleep- wake cycle, and fatigue increased and mental performance decreased compared with morning and evening duty. It was also found that the weekly shift group had a higher fatigue score on the sixth day of night duty as compared to the -first day, but the waking time, sleep- wake cycle, and mental performance revealed no difference for the duration of the night duty or between shift groups, and complete adaptation of temperature rhythm was achieved between the sixth and ninth day of night duty. It is possible to conclude from these results that for intermediate circadian type in a healthy young woman, a biweekly shift system is more compatible with the circadian timing system than weekly shift system.

  • PDF

Long-Term Performance Prediction of Carbon Fiber Reinforced Composites Using Dynamic Mechanical Analyzer (동적기계분석장치를 이용한 탄소섬유/에폭시 복합재의 장기 성능 예측)

  • Cha, Jae Ho;Yoon, Sung Ho
    • Composites Research
    • /
    • v.32 no.1
    • /
    • pp.78-84
    • /
    • 2019
  • This study focused on the prediction of the long-term performance of carbon fiber/epoxy composites using Dynamic Mechanical Analysis (DMA) and Time-Temperature Superposition (TTS). Single-frequency test, multi-frequency test, and creep TTS test were performed. A sinusoidal load of $20{\mu}m$ amplitude was applied while increasing the temperature from $-30^{\circ}C$ to $240^{\circ}C$ at $2^{\circ}C/min$ for the single-frequency test and the multi-frequency test. The frequencies applied to the multi-frequency test were 0.316, 1, 3.16, 10 and 31.6 Hz. In the creep TTS test, a stress of 15 MPa was applied for 10 minutes at every $10^{\circ}C$ from $-30^{\circ}C$ to $230^{\circ}C$. The glass transition temperature was determined by single-frequency test. The activation energy and the storage modulus curve for each temperature were obtained from glass transition temperature for each frequency by the multi-frequency test. The master curve for the reference temperature was obtained by applying the shift factor using the Arrhenius equation. Also, TTS test was used to obtain the creep compliance curves for each temperature and the master curve for the reference temperature by applying the shift factors using the manual shift technique. The master curve obtained through this process can be applied to predict the long-term performance of carbon fiber/epoxy composites for a given environmental condition.

A Study on Reliability Verification of Resonance Frequency Detection of Vibration Object using Time-average ESPI (시간 평균 ESPI를 이용한 진동 물체의 공진 주파수 검출 신뢰도 검증에 대한 연구)

  • Hong Kyung-Min;Ryu Weon-Jae;Kang Young-Jung;Lee Dong-Hwan
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.930-933
    • /
    • 2005
  • Non-destructive inspection techniques using laser have been breading their application areas as well as growing their measurement skills together with the rapid development of circumferential technology like fiber optics. computer and image processing The ESPI technique is already on the stage of on-line testing with commercial products in developed country nations. Especially, this technique is expected to be applied to the nuclear industry, automobile and aerospace because it is proper for the vibration measurement and it can be applied to objects of a high temperature. This paper describes the use of the ESPI system for measuring vibration patterns on the reflecting objects. Using this system, high-quality Jo fringes for identifying mode shapes are displayed. A bias vibration is introduced into the reference beam to shift the Jo fringes so that fringe shift algorithms can be used to determine vibration amplitude. Using this method. amplitude fields for vibrating objects were obtained directly from the time-average interferometer recorded by the ESPI system.

  • PDF

Comparison of Optical Properties of Ga-doped and Ag-doped ZnO Nanowire Measured at Low Temperature

  • Lee, Sang Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.5
    • /
    • pp.262-264
    • /
    • 2014
  • Pristine ZnO, 3 wt.% Ga-doped (3GZO) and 3 wt.% Ag-doped (3SZO) ZnO nanowires (NWs) were grown using the hot-walled pulse laser deposition (HW-PLD) technique. The doping of Ga and Ag in ZnO NWs was observed by analyzing the optical and chemical properties. We optimized the synthesis conditions, including processing temperature, time, gas flow, and distance between target and substrate for the growth of pristine and doped ZnO NWs. The diameter and length of pristine and doped ZnO NWs were controlled under 200 nm and several ${\mu}m$, respectively. Low temperature photoluminescence (PL) was performed to observe the optical property of doped NWs. We clearly observed the shift of the near band edge (NBE) emission by using low temperature PL. In the case of 3GZO and 3SZO NWs, the center photon energy of the NBE emissions shifted to low energy direction using the Burstein Moss effect. A strong donor-bound exciton peak was found in 3 GZO NWs, while an acceptor-bound exciton peak was found in 3SZO NWs. X-ray photoelectron spectroscopy (XPS) also indicated that the shift of binding energy was mainly attributed to the interaction between the metal ion and ZnO NWs.

In situ Photoacoustic Study of Water Gas Shift Reaction over Magnetite/Chromium Oxide and Copper/Zinc Oxide Catalysts

  • Byun, In-Sik;Choi, Ok-Lim;Choi, Joong-Gill;Lee, Sung-Han
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.11
    • /
    • pp.1513-1518
    • /
    • 2002
  • Kinetic studies on the water-gas shift reaction catalyzed by magnetite/chromium oxide and copper/zinc oxide were carried out by using an in situ photoacoustic spectroscopic technique. The reactions were performed in a closed-circulation reactor system using a differential photoacoustic cell at total pressure of 40 Torr in the temperature range of 100 to $350^{\circ}C.$ The CO2 photoacoustic signal varying with the concentration of CO2 during the catalytic reaction was recorded as a function of time. The time-resolved photoacoustic spectra obtained for the initial reaction stage provided precise data of CO2 formation rate. The apparent activation energies determined from the initial rates were 74.7 kJ/mol for the magnetite/chromium oxide catalyst and 50.9 kJ/mol for the copper/zinc oxide catalyst. To determine the reaction orders, partial pressures of CO(g) and H2O(g) in the reaction mixture were varied at a constant total pressure of 40 Torr with N2 buffer gas. For the magnetite/chromium oxide catalyst, the reaction orders with respect to CO and H2O were determined to be 0.93 and 0.18, respectively. For the copper/zinc oxide catalyst, the reaction orders with respect to CO and H2O were determined to be 0.79 and 0, respectively.

MEASUREMENT OF THE VIBRATION MODE SHAPE USING THE TIME AVERAGE FSPI (시간평균 ESPI에 의한 진동 MODE SHAPE의 계측)

  • 최장섭;강영준;문상섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.308-313
    • /
    • 1995
  • Non-destructive inspection techniques using laser have been broading their application areas as well as growing their measurement skills together with the rapid development of circumferential technology like fiber optics and computer. The remarkable inspection technique using laser speckle, so-called ESPI is aleady on the stage of on-line testing with commercial products in other nations. Especially, this technique is expected to be applied to the nuclear industry. Because it is proper for the vibration measurement and it can be applied to objects of a high temperature. This paper describes the use of the ESPI system for measuring vibration patterns on the reflecting objects. Using this system, high-quality Jo fringers fso that fringe shift algorthms can be used to determine vibration interferograms recorded by the ESPI system.

  • PDF