Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.

Investigation of light stimulated mouse brain activation in high magnetic field fMRI using image segmentation methods

  • Kim, Wook;Woo, Sang-Keun;Kang, Joo Hyun;Lim, Sang Moo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.11-18
    • /
    • 2016
  • Magnetic resonance image (MRI) is widely used in brain research field and medical image. Especially, non-invasive brain activation acquired image technique, which is functional magnetic resonance image (fMRI) is used in brain study. In this study, we investigate brain activation occurred by LED light stimulation. For investigate of brain activation in experimental small animal, we used high magnetic field 9.4T MRI. Experimental small animal is Balb/c mouse, method of fMRI is using echo planar image (EPI). EPI method spend more less time than any other MRI method. For this reason, however, EPI data has low contrast. Due to the low contrast, image pre-processing is very hard and inaccuracy. In this study, we planned the study protocol, which is called block design in fMRI research field. The block designed has 8 LED light stimulation session and 8 rest session. All block is consist of 6 EPI images and acquired 1 slice of EPI image is 16 second. During the light session, we occurred LED light stimulation for 1 minutes 36 seconds. During the rest session, we do not occurred light stimulation and remain the light off state for 1 minutes 36 seconds. This session repeat the all over the EPI scan time, so the total spend time of EPI scan has almost 26 minutes. After acquired EPI data, we performed the analysis of this image data. In this study, we analysis of EPI data using statistical parametric map (SPM) software and performed image pre-processing such as realignment, co-registration, normalization, smoothing of EPI data. The pre-processing of fMRI data have to segmented using this software. However this method has 3 different method which is Gaussian nonparametric, warped modulate, and tissue probability map. In this study we performed the this 3 different method and compared how they can change the result of fMRI analysis results. The result of this study show that LED light stimulation was activate superior colliculus region in mouse brain. And the most higher activated value of segmentation method was using tissue probability map. this study may help to improve brain activation study using EPI and SPM analysis.

Automatic Detection and Classification of Rib Fractures on Thoracic CT Using Convolutional Neural Network: Accuracy and Feasibility

  • Qing-Qing Zhou;Jiashuo Wang;Wen Tang;Zhang-Chun Hu;Zi-Yi Xia;Xue-Song Li;Rongguo Zhang;Xindao Yin;Bing Zhang;Hong Zhang
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.869-879
    • /
    • 2020
  • Objective: To evaluate the performance of a convolutional neural network (CNN) model that can automatically detect and classify rib fractures, and output structured reports from computed tomography (CT) images. Materials and Methods: This study included 1079 patients (median age, 55 years; men, 718) from three hospitals, between January 2011 and January 2019, who were divided into a monocentric training set (n = 876; median age, 55 years; men, 582), five multicenter/multiparameter validation sets (n = 173; median age, 59 years; men, 118) with different slice thicknesses and image pixels, and a normal control set (n = 30; median age, 53 years; men, 18). Three classifications (fresh, healing, and old fracture) combined with fracture location (corresponding CT layers) were detected automatically and delivered in a structured report. Precision, recall, and F1-score were selected as metrics to measure the optimum CNN model. Detection/diagnosis time, precision, and sensitivity were employed to compare the diagnostic efficiency of the structured report and that of experienced radiologists. Results: A total of 25054 annotations (fresh fracture, 10089; healing fracture, 10922; old fracture, 4043) were labelled for training (18584) and validation (6470). The detection efficiency was higher for fresh fractures and healing fractures than for old fractures (F1-scores, 0.849, 0.856, 0.770, respectively, p = 0.023 for each), and the robustness of the model was good in the five multicenter/multiparameter validation sets (all mean F1-scores > 0.8 except validation set 5 [512 x 512 pixels; F1-score = 0.757]). The precision of the five radiologists improved from 80.3% to 91.1%, and the sensitivity increased from 62.4% to 86.3% with artificial intelligence-assisted diagnosis. On average, the diagnosis time of the radiologists was reduced by 73.9 seconds. Conclusion: Our CNN model for automatic rib fracture detection could assist radiologists in improving diagnostic efficiency, reducing diagnosis time and radiologists' workload.

A Study of Augmented Reality based Visualization using Shape Information of Building Information Modeling (BIM 형상정보를 이용한 증강현실기반 가시화 사례)

  • Heo, Kyung-Jin;Lee, Seok-Jun;Jung, Soon-Ki
    • Spatial Information Research
    • /
    • v.20 no.2
    • /
    • pp.1-11
    • /
    • 2012
  • In the current construction planning and designing process, an architectural miniature model was designed to verify the interior or exterior spatial sense of a building structure, but building of the miniature model is demand much more effort and time; in addition to this it has limitation to identify interior information of the building. For a complement of it, CAD would be used in the existing planning and designing process to visualize the building information, but its visualization is not satisfactory for the 3D volume which could be easily verified with the miniature model. CAD is the specific software for designing building structures and the 3D results are usually rendered on 2D monitor screen. Therefore, there is a shortage of cognitive immersion for the 3D space. In this paper, we introduce the conversion process of BIM shape data into the Augmented Reality contents by using a series of softwares. As a result of modification on construction plan or design we reduced the cost and time to reconstruct the final visualization. We have shown that the interior or exterior information of the building structures are easily visualized with BIM shape data on augmented reality environment. Several proposed interaction methods, such as rem oval of building components, and slice-cut operation, provide the user for the effective manipulation of models on the augmented reality environment.

Phantom-Validated Reference Values of Myocardial Mapping and Extracellular Volume at 3T in Healthy Koreans

  • Lee, Eunjin;Kim, Pan Ki;Choi, Byoung Wook;Jung, Jung Im
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.141-153
    • /
    • 2020
  • Purpose: Myocardial T1 and T2 relaxation times are affected by technical factors such as cardiovascular magnetic resonance platform/vendor. We aimed to validate T1 and T2 mapping sequences using a phantom; establish reference T1, T2, and extracellular volume (ECV) measurements using two sequences at 3T in normal Koreans; and compare the protocols and evaluate the differences from previously reported measurements. Materials and Methods: Eleven healthy subjects underwent cardiac magnetic resonance imaging (MRI) using 3T MRI equipment (Verio, Siemens, Erlangen, Germany). We did phantom validation before volunteer scanning: T1 mapping with modified look locker inversion recovery (MOLLI) with 5(3)3 and 4(1)3(1)2 sequences, and T2 mapping with gradient echo (GRE) and TrueFISP sequences. We did T1 and T2 mappings on the volunteers with the same sequences. ECV was also calculated with both sequences after gadolinium enhancement. Results: The phantom study showed no significant differences from the gold standard T1 and T2 values in either sequence. Pre-contrast T1 relaxation times of the 4(1)3(1)2 protocol was 1142.27 ± 36.64 ms and of the 5(3)3 was 1266.03 ± 32.86 ms on the volunteer study. T2 relaxation times of GRE were 40.09 ± 2.45 ms and T2 relaxation times of TrueFISP were 38.20 ± 1.64 ms in each. ECV calculation was 24.42% ± 2.41% and 26.11% ± 2.39% in the 4(1)3(1)2 and 5(3)3 protocols, respectively, and showed no differences at any segment or slice between the sequences. We also calculated ECV from the pre-enhancement T1 relaxation time of MOLLI 5(3)3 and the post-enhancement T1 relaxation time of MOLLI 4(1)3(1)2, with no significant differences between the combinations. Conclusion: Using phantom-validated sequences, we reported the normal myocardial T1, T2, and ECV reference values of healthy Koreans at 3T. There were no statistically significant differences between the sequences, although it has limited statistical value due to the small number of subjects studied. ECV showed no significant differences between calculations based on various pre- and post-mapping combinations.

The Kinematic Analysis of the Tennis Flat Serve Motion (테니스 플랫 서브 동작의 운동학적 분석)

  • Oh, Cheong-Hwan;Choi, Su-Nam;Nam, Taek-Gil
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.97-108
    • /
    • 2006
  • C. H. OH, S. N. CHOI, T. G. NAM, The Kinematic Analysis of the Tennis Flat Serve Motion, Korean Jiurnal of Sports Biomechanics, Vol. 16, No. 2, pp. 97-108, 2006. By the comparison and the analysis of the different factors during the tennis flat serve motion such as the required time per section, the movement displacement of the racket, the velocity of the upper limbs joints, the physical center of gravity, and the angle and the angular velocity of the upper limbs joints between an ace player and a mediocre player, these following results were drawn. First, the experiment result of the total time required per section in a tennis flat serve motion showed that an ace player was faster than a mediocre player by 0.4 seconds. This result suggested that it was required to increase the speed of the racket head by a swift swing to perform an effective flat serve motion. Second, the experiment result of the movement displacement of the racket in the tennis flat serve motion showed that an ace player greatly moved toward the left side on an x-axis. But both an ace and a mediocre player were shown to be at the similar points on a y-axis at the moment of the impact of the racket. An ace player was also shown to be located at a higher position on a z-axis by 0.23m. Third, the velocity of the center of gravity of an ace player was faster in every phase than that of a mediocre player in a tennis flat serve motion. Fourth, the velocity of the upper limb joints of an ace player was faster in every phase than that of a mediocre player in a tennis flat serve motion. Fifth, the experiment result of the speed of the racket head in tennis flat serve motion showed that a mediocre player was faster than an ace player in the first phase, but the latter was faster than the former in the second, third, and the fourth phases. Sixth, at the moment of impact of a tennis flat serve, an ace player had greater flexion of the angle of the wrist joints by an 11.8 degree than a mediocre player. An ace player also had greater extension of the angle of the elbow joint and the shoulder joint respectively by a 5.2 degree and a 1.4 degree with a mediocre player. Seventh, an ace player had greater angular velocity of the upper limb joints and the hip joints than a mediocre player at the moment of the impact of tennis flat serve. Eighth, an ace player was shown to have a greater change of the forward and the backward inclination (or the anterior and posterior inclination) of the upper body

Effects of Freezing-Thawing Conditions on Physicochemicnl and Histological Properties of Plaice, Paralichthys olivaceus Muscle (동결-해동 조건이 넙치육의 물리$\cdot$화학적 및 조직학적 변화에 미치는 영향)

  • CHO Young-Je;CHO Min-Sung;LEE Nam-Gul;CHOI Young-Jun;KIM Tae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.463-470
    • /
    • 1998
  • To improve muscle quality and prolong freshness of sashimi, the effects of freezing-thawing condition on physicochemical and rheological properties of plaice muscle were investigated. Muscle tested were frozen with quick freezing (liquid nitrogen gas) or slow freezing ($-15^{\circ}C$ air). Transition time of zone of ice crystal formation was within 10 minute for quick freezing and 110 minute for slow freezing. Time required for thawing to $0^{\circ}C$ in muscle temperature by various thawing methods was shortest with $25^{\circ}C$ tap water, followed by $15^{\circ}C$ tap water, $10^{\circ}C$ tap water, $25^{\circ}C$ air, $5^{\circ}C$ tap water and $0^{\circ}C$ cold water. Breaking strength of muscle was higher in quickly frozen sample than in slowly frozen sample. According to sashimi term, changes in breaking strength of muscle did not show any difference in quickly frozen sample, while showed significant difference in slowly frozen sample. The remaining content of ATP was not effected by freezing speed, and ATP content was apt to higher in quickly thawed sample than in slowly thawed sample. IMP was the majority of ATP and it's related compounds of sample after freezing and thawing. Collagen matrix was weakened markedly in slowly frozen sample than in quickly frozen sample.

  • PDF

Eternal Love of Hwang Jin-yi that Unfolding Section of Yearning (그리움의 절편을 빚어내는 황진이의 영원한 사랑)

  • Park, Inkwa
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.209-214
    • /
    • 2019
  • The study is a hypothetical one about how to cut out a single emotion and activate it positively. The study could be used to treat literary therapy through AI. In this study, Hwang Jin-yi's Sijo "Long and Long Night of Winter Solstice Month" was studied. Because this work is very appropriate for the study of emotional cutting and interlinking. This counting method of treatment was used in this Sijo. Hwang Jin-yi's work cuts out "Long and Long Night of Winter Solstice Month" from the beginning. And they dream of regenerating their emotions by putting the time of their cut-off under the 'blanket of the spring breeze.' And in the end, the time of yearning unfolds to infinity, very finely. The extended hours of longing were added to the 'blanket of the spring breeze.' Spread out the times of yearning, it dreams of eternal love, the yearning for everlasting love. These literary acts are expected to lead to many changes in the human nervous system. This is the method of love that dreams of healing emotions in literature. Lover was left but not sent, lover's love amplifies feelings of joy. This method of emotional counting is believed to be very useful in the upcoming literary treatment by AI.

Quality Enhancement of Kimchi by Pre-Treatment with Slightly Acidic Electrolyzed Water and Mild Heating during Storage (미산성 차아염소산수와 미가열 병용 처리를 통한 원료 전처리 및 김치 저장 중 품질 확보)

  • Park, Joong-Hyun;Kim, Ha-Na;Oh, Deog-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.2
    • /
    • pp.269-276
    • /
    • 2016
  • This study was conducted to determine the inactivation effects of slightly acidic electrolyzed water (SAEW) on microorganisms attached to salted Chinese cabbage and food materials of kimchi, such as slice radish and green onion. In addition, changes in microbial and physicochemical quality of manufactured kimchi during storage at $4^{\circ}C$ for 4 weeks were investigated. Compared to the untreated control with tap water, total bacterial counts (TBC) of Chinese cabbage, slice radish, and green onion were reduced by 1.75, 1.68, and 1.03 log CFU/g at dipping times of 20 min, 5 min, and 10 min, respectively, upon treatment with 30 ppm SAEW at $40^{\circ}C$. Effect of microbial inhibition was higher in salted Chinese cabbage brined in 10% salt (w/v) of 30 pm SAEW at $40^{\circ}C$ than in untreated control with tap water, as indicated by 1.00 log CFU/g reduction. TBC of kimchi manufactured with materials treated with 30 ppm SAEW at $40^{\circ}C$ was not significantly affected compared to untreated control, although coliforms were remarkably reduced compared to the untreated control. At the beginning of storage (1 weeks), TBC and lactic acid bacteria (LAB) counts increased by approximately 9 and 7.66~8.18 log CFU/g, respectively, and coliforms were completely eliminated. The pH and acidity of kimchi at 2 weeks were 4.34~4.49 and 0.55~0.66%, respectively, and then slowly decreased. The texture (firmness) of kimchi decreased with storage time, but the difference was not significant. This combined treatment might be considered as a potentially beneficial sanitizing method for improving the quality and safety of kimchi.

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF