• Title/Summary/Keyword: Time slice

검색결과 239건 처리시간 0.022초

SLS의 공정 파라미터 최적화에 관한 연구 (Optimization of Build Parameters in SLS Process)

  • 허성민;오도근;최경현;이석희
    • 대한기계학회논문집A
    • /
    • 제24권3호
    • /
    • pp.769-776
    • /
    • 2000
  • RP(Rapid Prototyping) technology is gaining its popularity in building a prototype in all industries. SLS(Slective Laser Sintering) is one of RP technologies, which is focused on tooling processes as well as three dimension solid model. There are several factors, the length and the cross-sectional area of a part, that have an effect on build setup in SLS process. In this paper, the computation on geometrical relationship is used to slice STL file and to estimate these factors. Based on these values, the build setup parameters such as the heating temperature, the laser power, and the powder cartridge feed rate are determined by neural network approaches. The test results show that the computation time is saved and the neural network approach is able to apply to get the optimal parameters of build process within an acceptable error rate.

Adaptive Slicing with Curvature Considerations

  • Banerjee, Ashis Gopal;Kumar, Aloke;Tejavath, Shankar;Choudhury, Asimava Roy
    • International Journal of CAD/CAM
    • /
    • 제3권1_2호
    • /
    • pp.31-40
    • /
    • 2003
  • In this paper, first order slice height calculation in Laminated Object Manufacturing (LOM) of free form surfaces is done with two different considerations: that a) the cutter trajectory is oriented in the direction of local absolute maximum more in number when compared to the case where the cutter trajectory is contained in the normal vertical section (NVS). However, it would help in achieving higher form accuracy of the final part because it would be a form of worst-case check. For the second proposed strategy, least number of slices results, thereby reducing overall build time drastically.

사구슬롯이 있는 3상 농형 유도 전동기의 인버터 구동시 토오크 특성 및 회전자 바 동손분포 해석 (Analysis of the Torque Characteristics and Loss Distribution of the Rotor Bar of an Inverter-fed Cage Induction Motor with Skewed Slots)

  • 김병택;최병일;박승찬;오경일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권12호
    • /
    • pp.797-806
    • /
    • 2000
  • In this paper, the torque characteristics and the bar loss distribution are analyzed when a general cage induction motor with skewed slots is fed by a 6-step inverter. For the electromagnetic analysis, time-stepping finite element method is used. And the multi-slice technique and sliding surface technique are respectively utilized to consider the skew effect and the rotation of the rotor. As a result, the effects of skewed rotor bar and the inverter output voltage on the characteristics of the torque and bar loss in the rotor are investigated. The simulation results are verified by measurement of flux density distribution axially in the stator teeth.

  • PDF

Agile Fabrication of a Sample by a Solid Freeform Fabrication System

  • Taijoon Um;Youngcheol Joo;Park, Sehyung;Sanghyun Min
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1740-1743
    • /
    • 2002
  • This paper presents the basic concept of a Solid Freeform Fabrication System using a rapid prototyping procedure. The system can fabricate a ceramic model by laser cutting, accumulating, laminating and sintering of each slice. The system is mainly equipped with a laser apparatus, an x-y table, a material transfer system, and an electric oven. The system could fabricate a small object with smooth surface within comparatively short period of time. The system has also shown its effectiveness in terms of the direct application of the object without the secondary mechanical process. The fabricated sample could directly be applied and used to fairly wide practical areas.

  • PDF

Digital Signal Processor와 개발시스템의 설계 및 구현 (Design and Implementation of Digital Signal Processor and Development System)

  • 임광일;이우선;신인철;이태원
    • 대한전자공학회논문지
    • /
    • 제23권6호
    • /
    • pp.902-907
    • /
    • 1986
  • A real-time microprogrammable digital signal processor is designed and implemented using the bit-slice logic, a parallel multiplier, 74 series TTLs and MOS memories. A microinstruction set for the processor is defined and an application program development system is constructed. For its performance evalution, a digital filter and FFT are implemented with this digital signal processor. It is proved that this processor is faster than commrcially available single chip digital signal processors such as \ulcornerD 7720, AMI 2811, enabling very high speed digital signal processing.

  • PDF

Cellular Band의 슬롯형 CDMA 무선통신 모듈 설계 (Design of a Slot Type CDMA Wireless Communication Module on the Celluar Band)

  • 류태영;차경호;이창식
    • 한국산업정보학회논문지
    • /
    • 제9권2호
    • /
    • pp.89-95
    • /
    • 2004
  • CDMA(Code Division Multiple Access)는 이동통신에서 다수의 사용자들이 동시에 시간과 주파수를 공유하며 접속이 가능한 다중접속(Multiple Access) 방식의 하나이다. 그렇지만 이동통신은 주파수라는 한정된 자원을 이용하기 때문에 용량이 제한된 가용 주파수 자원을 여러 사람이 효율적으로 공유할 수 있도록 하는 다중접속이 이동통신에서는 필수적인 기술이다. CDMA는 홈네트워크, 군사용, 상업용뿐만 아니라 의료분야에까지도 다양하게 응용되어가고 있다. 본 논문은 기존 양면보드 방식이 아닌 PCB 8계층의 적층방식을 단면보드 회로로 구성하여 RF(Radio Frequency)특성을 유지하며, 슬롯형의 커넥터를 적용한 Cellular Band의 CDMA 모듈의 설계 및 성능 분석 결과를 제시한다.

  • PDF

MR Line Scan Angiography using Spectral Analysis

  • Jung, Kwan-Jin;Ro, Yong-Man;Sim, Bog-Tae;Ra, Jong-Beom;Cho, Zang-Hee
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.27-28
    • /
    • 1989
  • In conventional line scan angiography, flow signal has been enhanced by the time_of_flight effect while the signal from stationary tissues has been suppressed by the saturation rf pulse followed by spoiling gradients. Due to the inhomogeneous rf field and the tissue dependent T1 relaxation time, however, stationary tissues can not be suppressed completely or uniformly, and the remnant stationary signal deteriorates the resultant angiogram. Here, the complete cancellation of stationary tissues is made possible by the spectral analysis of a series of repetitive line images of the same slice. The Fourier transformation of a set of line images results in the spectrum images, where stationary tissues are collected into the dc component while arteries are included in harmonic components because of the variation of the flow velocity and the resultant flow signal in arteries according to the cardiac cycle. The summation of harmonic components excluding the dc component results in the angiogram of arteries with the complete cancellation of stationary tissues.

  • PDF

Time of Flight 원리를 이용한 삼차원 자기공명 혈관조영술의 구현 (Magnetic Resonance Angiography using 3D Time-Of-Flight Method)

  • 이윤;류택현;김시승;안성혁;이만우;정관진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.96-97
    • /
    • 1998
  • 3D TOF MR Angiography is able to obtain thinner slice thickness, higher SNR, therefore higher spatial resolution than 2D TOF MR Angiography. Since it uses longer TR than 2D TOF MRA to allow stronger in-flow effect, the background tissue may not be fully saturated. Thus background tissue signal can be further suppressed by MTS(Magnetization Transfer Saturation). Flow-compensation was accomplished by GMN(Gradient Moment Nulling), and tracking saturation was used to suppress vein signal. The different flow signal at the entry of the slab and output of the slab can be compensated by TONE(Tilted Optimized Non-saturating Excitation) RF pulse.

  • PDF

압축성이 슬로싱 현상에 미치는 영향에 관한 실험적 연구 (An Experimental Study on Compressibility Effect in Sloshing Phenomenon)

  • 박준수;김현이;이기현;권순홍;전수성;정병훈
    • 한국해양공학회지
    • /
    • 제23권4호
    • /
    • pp.12-18
    • /
    • 2009
  • The present study focused on the compressibility of partially filled fluids in a sloshing tank. Filling ratios ranging from 18% to 26% were used to find compressible impact on a vertical wall. The model test was for 1/25 scale of a 138 K LNGC cargo tank. To investigate the two dimensional phenomenon of sloshing, a longitudinal slice model was tested. A high speed camera was used to capture the flow field, as well as the air pocket deformation. The pressure time history synchronized with the video images revealed the entire compressible process. Three typical impact phenomena were observed: hydraulic jump, flip through, and plunging breaker. In particular, the pressure time history and flow pattern details for flip through and plunging breaker are presented.

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.