• Title/Summary/Keyword: Time slice

Search Result 239, Processing Time 0.026 seconds

Projection-type Fast Spin Echo Imaging (프로젝션 타입 고속 스핀 에코 영상)

  • 김휴정;김치영;김상묵;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.42-51
    • /
    • 2000
  • Purpose: Projection-type Fast Spin Echo (PFSE) imaging is robust to patient motion or flow related artifact compared to conventional Fast Spin Echo (FSE) imaging, however, it has difficulty in controlling $T_2$ contrast. In this paper, Tz contrast in the PFSE method is analyzed and compared with those of the FSE method with various effective echo times by computer simulation. The contrasts in the FSE and PFSE methods are also compared by experiments with volunteers. From the analysis and simulation, it is shown that ${T_2}-weighted$ images can well be obtained by the PFSE method proposed. Materials and methods: Pulse sequence for the PFSE method is implemented at a 1.0 Tesla whole body MRI system and $T_2$ contrasts in the PFSE and FSE methods are analyzed by computer simulation and experiment with volunteers. For the simulation, a mathematical phantom composed of various $T_2$ values is devised and $T_2$ contrast in the reconstructed image by the PFSE is compared to those by the FSE method with various effective echo times. Multi-slice ${T_2}-weighted$ head images of the volunteers obtained by the PFSE method are also shown in comparison with those by the FSE method at a 1.0 Tesla whole body MRI system. Results: From the analysis, $T_2$ contrast by the PFSE method appears similar to those by the FSE method with the effective echo time in a range of SO-lOOms. Using a mathematical phantom, contrast in the PFSE image appears close to that by the FSE method with the effective echo time of 96ms. From experiment with volunteers, multi-slice $T_2-weighted$ images are obtained by the PFSE method having contrast similar to that of the FSE method with the effective echo time of 96ms. Reconstructed images by the PFSE method show less motion related artifact compared to those by the FSE method. Conclusion: The projection-type FSE imaging acquires multiple radial lines with different angles in polar coordinate in k space using multiple spin echoes. The PFSE method is robust to patient motion or flow, however, it has difficulty in controlling $T_2$ contrast compared to the FSE method. In this paper, it is shown that the PFSE method provides good $T_2$ contrast (${T_2}-weighted$ images) similar to the FSE method by both computer simulation and experiments with volunteers.

  • PDF

Fixed Time Synchronous IPC in Zephyr Kernel (Zephyr 커널에서 고정 시간 동기식 IPC 구현)

  • Jung, Jooyoung;Kim, Eunyoung;Shin, Dongha
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.4
    • /
    • pp.205-212
    • /
    • 2017
  • Linux Foundation has announced a real-time kernel, called Zephyr, for IoT applications recently. Zephyr kernel provides synchronous and asynchronous IPC for data communication between threads. Synchronous IPC is useful for programming multi-threads that need to be executed synchronously, since the sender thread is blocked until the data is delivered to the receiver thread and the completion of data transfer can be known to two threads. In general, 'IPC execution time' is defined as the time duration between the sender thread sends data and the receiver thread receives the data sent. Especially, it is important that 'IPC execution time' in the synchronous IPC should be fixed in real-time kernel like Zephyr. However, we have found that the execution time of the synchronous IPC in Zephyr kernel increases in proportion to the number of threads executing in the kernel. In this paper, we propose a method to implement a fixed time synchronous IPC in Zephyr kernel using Direct Thread Switching(DTS) technique. Using the technique, the receiver thread executes directly after the sender thread sends a data during the remaining time slice of the sender thread and we can archive a fixed IPC execution time even when the number of threads executing in the kernel increases. In this paper, we implemented synchronous IPC using DTS in the Zephyr kernel and found the IPC execution time of the IPC is always 389 cycle that is relatively small and fixed.

Fast Mode Decision using Block Size Activity for H.264/AVC (블록 크기 활동도를 이용한 H.264/AVC 부호화 고속 모드 결정)

  • Jung, Bong-Soo;Jeon, Byeung-Woo;Choi, Kwang-Pyo;Oh, Yun-Je
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.2 s.314
    • /
    • pp.1-11
    • /
    • 2007
  • H.264/AVC uses variable block sizes to achieve significant coding gain. It has 7 different coding modes having different motion compensation block sizes in Inter slice, and 2 different intra prediction modes in Intra slice. This fine-tuned new coding feature has achieved far more significant coding gain compared with previous video coding standards. However, extremely high computational complexity is required when rate-distortion optimization (RDO) algorithm is used. This computational complexity is a major problem in implementing real-time H.264/AVC encoder on computationally constrained devices. Therefore, there is a clear need for complexity reduction algorithm of H.264/AVC such as fast mode decision. In this paper, we propose a fast mode decision with early $P8\times8$ mode rejection based on block size activity using large block history map (LBHM). Simulation results show that without any meaningful degradation, the proposed method reduces whole encoding time on average by 53%. Also the hybrid usage of the proposed method and the early SKIP mode decision in H.264/AVC reference model reduces whole encoding time by 63% on average.

Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application (Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구)

  • Kim, Sae-Ssak;Goo, Eun-Hoe;Dong, Kyung-Rae;Kweon, Dae-Chel;Lee, Jae-Seung;Cho, Jae-Hwan;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

A Threshold Controller for FAST Hardware Accelerator (FAST 하드웨어 가속기를 위한 임계값 제어기)

  • Kim, Taek-Kyu;Suh, Yong-Suk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.187-192
    • /
    • 2014
  • Various researches are performed to extract significant features from continuous images. The FAST algorithm has the simple structure for arithmetic operation and it is easy to extraction the features in real time. For this reason, the FPGA based hardware accelerator is implemented and widely applied for the FAST algorithm. The hardware accelerator needs the threshold to extract the features from images. The threshold is influenced not only the number of extracted features but also the total execution time. Therefore, the way of threshold control is important to stabilize the total execution time and to extract features as much as possible. In order to control the threshold, this paper proposes the PI controller. The function and performance for the proposed PI controller are verified by using test images and the PI control logic is designed based on Xilinx Vertex IV FPGA. The proposed scheme can be implemented by adding 47 Flip Flops, 146 LUTs, and 91 Slices to the FAST hardware accelerator. This proposed approach only occupies 2.1% of Flip Flop, 4.4% of LUTs, and 4.5% of Slices and can be regarded as a small portion of hardware cost.

Investigation of Perfusion-weighted Signal Changes on a Pulsed Arterial Spin Labeling Magnetic Resonance Imaging Technique: Dependence on the Labeling Gap, Delay Time, Labeling Thickness, and Slice Scan Order (동맥스핀표지 뇌 관류 자기공명영상에서 라벨링 간격 및 지연시간, 표지 두께, 절편 획득 순서의 변화에 따른 관류 신호변화 연구)

  • Byun, Jae-Hoo;Park, Myung-Hwan;Kang, Ji-Yeon;Lee, Jin-Wan;Lee, Kang-Won;Jahng, Geon-Ho
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.108-118
    • /
    • 2013
  • Currently, an arterial spin labeling (ASL) magnetic resonance imaging (MRI) technique does not routinely used in clinical studies to measure perfusion in brain because optimization of imaging protocol is required to obtain optimal perfusion signals. Therefore, the objective of this study was to investigate changes of perfusion-weighed signal intensities with varying several parameters on a pulsed arterial spin labeling MRI technique obtained from a 3T MRI system. We especially evaluated alternations of ASL-MRI signal intensities on special brain areas, including in brain tissues and lobes. The signal targeting with alternating radiofrequency (STAR) pulsed ASL method was scanned on five normal subjects (mean age: 36 years, range: 29~41 years) on a 3T MRI system. Four parameters were evaluated with varying: 1) the labeling gap, 2) the labeling delay time, 3) the labeling thickness, and 4) the slice scan order. Signal intensities were obtained from the perfusion-weighted imaging on the gray and white matters and brain lobes of the frontal, parietal, temporal, and occipital areas. The results of this study were summarized: 1) Perfusion-weighted signal intensities were decreased with increasing the labeling gap in the bilateral gray matter areas and were least affected on the parietal lobe, but most affected on the occipital lobe. 2) Perfusion-weighted signal intensities were decreased with increasing the labeling delay time until 400 ms, but increased up to 1,000 ms in the bilateral gray matter areas. 3) Perfusion-weighted signal intensities were increased with increasing the labeling thickness until 120 mm in both the gray and white matter. 4) Perfusion-weighted signal intensities were higher descending scans than asending scans in both the gray and white matter. We investigated changes of perfusion-weighted signal intensities with varying several parameters in the STAR ASL method. It should require having protocol optimization processing before applying in patients. It has limitations to apply the ASL method in the white matter on a 3T MRI system.

Slices Method of Petri Nets Using the Transitive Matrix for Scheduling Analysis in FMS (유연생산 시스템 스케쥴링 분석을 위한 추이적 행렬을 이용한 패트리 넷의 분할)

  • Song, You-Jin;Kim, Jong-Wuk;Lee, Jong-Kun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.4
    • /
    • pp.292-298
    • /
    • 2002
  • We focus on the slicing off some sub-nets using the transitive matrix. Control flows in the Petri nets is done based on the token flows. One control f]ow explains the independent tokens status and if the token-in divides into several tokens after firing a transition then the control flow divides to several flows, as well. Accordingly, we define that the basic unit of concur-rency (short BUC) is a set of the executed control flows based on the behavioral properties in the net. The BUC is S-invariant which has one control flow. We show the usefulness of transitive matrix to slice off some subnets from the original net based on BUC-through on an example.

Maximum-Intensity Projection for Magnetic Resonance Angiography (Magnetic Resonance Angiography를 위한 Maximum-Intensity Projection을 구현)

  • Yi, Y.;Ryu, T.H.;Kim, S.S.;Kim, I.Y.;Lee, M.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.484-488
    • /
    • 1997
  • In this Paper, We use Maximum-Intensity Projection(MIP) algorithms. Maximum-Intensity Projection algorithms currently used for construction of magnetic resonance angiograms. The blood flow in a volume of interest is represented by bright intensities in the MR data volume. The flow within the vasculature shows up in the projections plane. By relating the intensities of the pixel to their location in the slice, the total number of pixels considered for the projection plane was reduced, thus saving calculation time. The algorithm was written in visual C++.

  • PDF

Study of Karyotype , Meiosis and Isozyme of Hybrid from cross Lilium longiflorum x L. X elegans (Lilium longiflorum $\times$ L. X elegans 의 자방배양에 의해 얻어진 잡종 F$_1$의 핵형 , 감수분열 및 lsozyme에 대한 연구)

  • 윤의수
    • Korean Journal of Plant Resources
    • /
    • v.1 no.1
    • /
    • pp.80-87
    • /
    • 1988
  • Hybries which was made up by chromosome of L. longiflorum and L. x elegans, using root-tip individual which was obtained through ovary slice culture, and root-tip of these parents, with hoirugen staining, gimsa staining and Q-H staining inaccordance with the location and the existence of secondary construction which waslocating near short arm centromere of No, 1,2,6,9. In metaphase of meiosis ofhybrid which was made up by univalent from 2 individuals to 10 individuals wasobserved, and nuclear plate which was having abnormal type's synthesis amounted to91% of all cells whieh were observed. This result showed the fact that someobstacle arose annormal progress of the divission after that time. 63% of the cellshad micronucleus from 1 individlial to 4 individuals in tetrad phase of meiosisdivision. The peroxidase and $\alpha$ -estelase zymogram phenotypes of parents andhybrids were determined using agarlose IEF gel. Crosses were performed betweenparents bearing dissimilar allelomorphs in orther to discern the genetic control ofthe resolved enzymes. Genetic variation of hybrids were detected at all but 2 plant progenies.

  • PDF

Determining Variables of Fabrication for Stereolithograpy (유전자 알고리즘을 이용한 광조형장치의 작업변수 결정)

  • 전근수;백인환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.910-913
    • /
    • 2000
  • In this research we investigate geometric issues involved while using a particular rapid prototyping system, called Stereolithography(SLA). SLA create prototypes layer by layer, each layer being formed by scanning a laser beam across the x, y surface of a vat of liquid monomer mix. The performance of SLA is influenced by orientation and layer thickness of designed fabrication. The number of layer and the area needed support is influenced by the orientation and layer thickness of designed fabrication. The step influence and volume error is influenced by slice thickness. We minimize the support are, the number of layer and cusp height. These variables of fabrication is minimized using genetic algorithm. The time for genetic algorithm is as little as we can accept. So we calculate support area and cusp height simply.

  • PDF