• Title/Summary/Keyword: Time compression

Search Result 1,821, Processing Time 0.029 seconds

A New Design and Implementation of Digital Evidence Container for Triage and Effective Investigation (디지털 증거 선별 조사의 효율성을 위한 Digital Evidence Container 설계 및 구현)

  • Lim, Kyung-Soo;Lee, Chang-Hoon;Lee, Sang-In
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.4
    • /
    • pp.31-41
    • /
    • 2012
  • The law enforcement agencies in the worldwide are confiscating or retaining computer systems involved in a crime/civil case, if there are any, at the preliminary investigation stage, even though the case does not involve a cyber-crime. They are collecting digital evidences from the suspects's systems and using them in the essential investigation procedure. It requires much time, though, to collect, duplicate and analyze disk images in general crime cases, especially in cases in which rapid response must be taken such as kidnapping and murder cases. The enterprise forensics, moreover, it is impossible to acquire and duplicate hard disk drives in mass storage server, database server and cloud environments. Therefore, it is efficient and effective to selectively collect only traces of the behavior of the user activities on operating systems or particular files in focus of triage investigation. On the other hand, if we acquire essential digital evidences from target computer, it is not forensically sound to collect just files. We need to use standard digital evidence container from various sources to prove integrity and probative of evidence. In this article, we describe a new digital evidence container, we called Xebeg, which is easily able to preserve collected digital evidences selectively for using general technology such as XML and PKZIP compression technology, which is satisfied with generality, integrity, unification, scalability and security.

Hardware Implementation of Real-Time Blind Watermarking by Substituting Bitplanes of Wavelet DC Coefficients (웨이블릿 DC 계수의 비트평면 치환방법에 의한 실시간 블라인드 워터마킹 및 하드웨어 구현)

  • 서영호;김동욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3C
    • /
    • pp.398-407
    • /
    • 2004
  • In this paper, a blind watermarking method which is suitable to the video compression using 2-D discrete wavelet transform was proposed and implemented into the hardware using VHDL(VHSIC Hardware Description Language). The goal of the proposed watermarking algorithm is the authentication about the manipulation of the watermark embedded image and the detection of the error positions. Considering the compressed video image, the proposed watermarking scheme is unrelated to the quantization and is able to concurrently embed or extract the watermark. We experimentally verified that the lowest frequency subband(LL4) is not sensitive to the change in the spatial domain, so LL4 subband was selected for the mark space. And the combination of the bitplanes which has the properties of both the minimum degradation of the image and the robustness was chosen as the embedded Point in the mark space in LL4 subband. Since we know the watermark embedded positions and the watermark is embedded by not varying the value but changing the value, the watermark can be extracted without the original image. Also, for the security when exposing the watermark embedded position, we embed the encrypted watermark by the block cipher. The proposed watermark algorithm shows the robustness against the general image manipulation and is easily transplanted into the image or video compressor with the minimal changing in the structure. The designed hardware has 4037 LABs(24%) and 85 ESBs(3%) in APEX20KC EP20K400CF672C7 FPGA of Altera and stably operates in 82MHz clock frequency.

Transform Skip Mode Fast Decision Method for HEVC Encoding (HEVC 부호화를 위한 변환생략 모드 고속 선택 방법)

  • Yang, Seungha;Shim, Hiuk Jae;Lee, Dahee;Jeon, Byeungwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.4
    • /
    • pp.172-179
    • /
    • 2014
  • HEVC (High Efficiency Video Coding) fine-tuned many existing coding tools and adopted also many new coding techniques. As a result, HEVC has accomplished about 2 times of compression efficiency enhancement compared to the existing video coding standard of H.264/AVC. One of the newly adopted tools in HEVC is the transform skip scheme which performs quantization without transform. This technique improves coding efficiency especially with computer-generated images. However, the unavailability of global or local properties of general video signals demands encoder to decide whether performing transform or not for each TU (Transform Unit). The necessity of computing rate-distortion costs for this decision is one reason to increase encoder complexity. In this paper, a fast transform skip mode decision method is proposed, which is based on the fast decision of rate-distortion cost calculation for transform skip mode, by considering frequency characteristics of residual signal. The proposed method can reduce $4{\times}4$ TU encoding time by about 27.1% with only about 0.03% consequential decrement in BDBR.

The Fundamental Study on th e Soil Remediation for Copper Contaminated Soil using Nanobubble Water (나노버블수에 의한 구리 오염 토양의 정화에 관한 기초 연구)

  • Jeong, So-Hee;Kim, Dong-Chan;Han, Jung-Geun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 2017
  • The fundamental study for an application of nanobubble as a soil remediation enhancer on heavy metal contaminated soil was carried out. The existence and long-term stability of hydrogen nanobubbles were investigated by particle analysis and zeta-potential analysis. And the removal efficiency of copper using nanobubble water(NBW) and distilled water(DW) were compared and analyzed through a batch desorption test. As a result, it is confirmed that nanobubble which was fabricated by compression-dissolution type generator can exist for more than 14 days. The results of batch test show that copper removal of NBW was higher than that of DW irrespectively to soil type and increased as solid-liquid ratio and contact time increased, respectively. According to the pH change, the removal of copper on sand was higher on the acid side but the removal difference was slightly lower on the clay. It is considered that a high efficiency of NBW in copper removal is due to the large surface area and high zeta-potential of nanobubbles. Therefore, the nanobubble can be applied to soil remediation for heavy-metal contaminated soil as an eco-friendly enhancer.

A Micro Finite Element Analysis on Effects of Altering Monomer-to-Powder ]Ratio of Bone Cement During Vertebroplasty (골 시멘트 중합 비율 변경이 척추성형술 치료에 미치는 영향에 대한 비교 분석)

  • 김형도;탁계래;김한성
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.451-458
    • /
    • 2002
  • Osteoporosis is a systemic skeletal disease caused by low bone mass and the decrease of bone density in the microstructure of trabecular bone. Drug therapy(PTH Parathyroid hormone) may increase the trabecular thickness and thus bone strength. Vertebroplasty is a minimally invasive surgery foy the treatment of osteoporotic vertebral compression fracture. This Procedure includes Puncturing vertebrae and filling with Polymethylmethacrylate(PMMA). Although altering recommended monomer-to-Powder ratio affects material properties of bone cement, clinicians commonly alter the mixture ratio to decrease viscosity and increase the working time. The Purposes of this study were to analyze the effect of 4he monomer-to-powder ratio on the mechanical characteristics of trabecular. In this paper, the finite element model of human vertebral trabecualr bone was developed by modified Voronoi diagram, to analyze the relative effect of hormone therapy and vertebroplasty at the treatment of osteoporotic vertebrae. Trabeuclar bone models for vertebroplasty with varied monomer-to-Powder ratio(0.40∼1.07 ㎖/g) were analyzed. Effective modulus and strength of bone cement-treated models were approximately 60% of those of intact models and these are almost twice the values of hormone-treated models. The bone cement models with the ratio of 0.53㎖/g have the maximum modulus and strength. For the ratio of 1.07㎖/g, the modulus and strength were minimum(42% and 49% respectively) but these were greater than those for drug therapy. This study shows that bone cement treatment is more effective than drug therapy. It is found that in vertebroplasty, using a monomer-to-powder ratio different from that recommended by manufacturer nay significantly not only reduce the cement's material Properties but also deteriorate the mechanical characteristics of osteoporotic vertebrae.

Settlement Characteristics of a Large-Scale Foundation over a Sabkha Layer Consisting of Carbonate Sand (Sabkha층 탄산질 모래의 침하특성 및 상부기초의 거동)

  • Kim, Seok-Ju;Han, Heui-Soo
    • The Journal of Engineering Geology
    • /
    • v.23 no.3
    • /
    • pp.247-256
    • /
    • 2013
  • The carbonate sands of the Sabkha layer in the Middle East have very low shear strength. Therefore, instant settlement and time-dependent secondary settlement occur when inner voids are exposed, as in the case of particle crushing. We analyzed settlement of the Sabkha layer under a large-scale foundation by hydrotesting, and compared the field test results with the results of laboratory tests. With ongoing particle crushing, we observed the following stress-strain behaviors: strain-hardening (Sabkha GL-1.5 m), strain-perfect (Sabkha GL-7.0 m), and strain-softening (Sabkha GL-7.5 m). General shear failure occurred most frequently in dense sand and firm ground. Although the stress-strain behavior of Sabkha layer carbonate sand that of strain-softening, the particle crushing strength was low compared with the strain-hardening and strain-perfect behaviors. The stress-strain behaviors differ between carbonate sand and quartz sand. If the relative density of quartz sand is increased, the shear strength is also increased. Continuous secondary compression settlement occurred during the hydrotests, after the dissipation of porewater pressure. Particle crushing strength is relatively low in the Sabkha layer and its stress-strain behavior is strain-softening or strain-perfect. The particle crushing effect is dominant factor affecting foundation settlement in the Sabkha layer.

Design of a Holter Monitoring System with Flash Memory Card (플레쉬 메모리 카드를 이용한 홀터 심전계의 설계)

  • 송근국;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.251-260
    • /
    • 1998
  • The Holter monitoring system is a widely used noninvasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we design a high performance intelligent holter monitoring system which is characterized by the small-sized and the low-power consumption. The system hardware consists of one-chip microcontroller(68HC11E9), ECG preprocessing circuit, and flash memory card. ECG preprocessing circuit is made of ECG preamplifier with gain of 250, 500 and 1000, the bandpass filter with bandwidth of 0.05-100Hz, the auto-balancing circuit and the saturation-calibrating circuit to eliminate baseline wandering, ECG signal sampled at 240 samples/sec is converted to the digital signal. We use a linear recursive filter and preprocessing algorithm to detect the ECG parameters which are QRS complex, and Q-R-T points, ST-level, HR, QT interval. The long-term acquired ECG signals and diagnostic parameters are compressed by the MFan(Modified Fan) and the delta modulation method. To easily interface with the PC based analyzer program which is operated in DOS and Windows, the compressed data, that are compatible to FFS(flash file system) format, are stored at the flash memory card with SBF(symmetric block format).

  • PDF

CLINICAL STUDY OF SURGICALLY ASSISTED RAPID MAXILLARY EXPANSION (외과적 술식을 동반한 급속 상악 확장술의 임상 연구)

  • Yang, Chan-Young;Min, Seung-Ki;Oh, Sung-Hwang;Kwon, Kyung-Hwan;Lee, Jun;Cha, Jae-Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.1
    • /
    • pp.60-69
    • /
    • 2005
  • Orthopedic rapid maxillary expansion(RME) has been a common treatment modality used to widen narrow maxillae in young children. However, since more skeletally matured adolescents or adults has closed midpalatal suture, the result of RME was undesirable because of dental tipping with little or no basal skeletal movement and resulted to many other complications. After such treatment, complications often occurred such as alveolar bending, compression of periodontal ligament, extrusion, buccal tipping, and severe relapse. Thus, surgically assisted rapid maxillary expansion(SA-RME) is required, especially for patients over 14 years old, to skeletally release maxillary expansion. We used two methods of maxillary expansion surgery. Surgically assisted rapid maxillary expansion(SA-RME) & surgically assisted posterior segmental expansion(SA-PSE) were used for narrow maxilla. The study was divided into two groups(SA-RME group and SA-PSE group). SA-RME group was consisted of 2 males and 4 females, and the ages of materials ranged from 15 years to 25 years with a mean of 20.2 years. SA-PSE group was consisted of 1 male and 5 females, and the ages ranged from 13 years to 23 years with a mean of 18.7 years. Dental study models were fabricated before starting the expansion and immediately after the expansion was completed. It was fabricated again 1 month later, 3 months later when the expansion device was removed, and 6 months later after the expansion was completed. A repeated measures analysis of variance(ANOVA) test was applied to assess changes between each groups over time. The amount of expansion and the amount of tipping movement each in both groups were compared by using paired t-test and it was also compared between each subjects within the group by using independent t-test. Both SA-RME and SA-PSE group showed stable results, but SA-PSE group showed statical significance in tipping movement of second premolar. We compared 6 patients who recieved SA-RME with 6 patients who received SA-PSE, and appraised the clinical usefulness.

A Case of Pulmonary Gangrene Associated with Obstructive Pneumonia Due to Non-small Cell Lung Carcinoma (위치에 따라 이동하는 종괴를 포함한 공동으로 진행된 비소세포폐암에 동반된 폐렴)

  • Kim, Sung-Jun;Um, Tae-Chan;Moon, Kwie-Ae;Kim, Phil-Ho;Kim, Sang-Hyun;Jeoung, Byung-Oh;Lee, Hyuk-Pyo;Kim, Joo-In;Yum, Ho-Kee;Choi, Soo-Jeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.591-595
    • /
    • 1999
  • Pulmonary gangrene is a rare complication of severe pulmonary infection in which a pulmonary segment or lobe is sloughed. It is a part of a spectrum of disease in which lung tissue is devitalized(such as necrotizing pneumonia, pulmonary abscess), but apart from them, pulmonary gangrene has more extensive area of necrosis and thrombosis of large vessels plays a prominent role in the pathogenesis. We experienced a case of pulmonary gangrene in 71 year old female obstructive pneumonia patient with non-small cell lung carcinoma. She complained high fever, chill and despite treatment with antibiotics, pneumonia progressed to empyema. At that time chest radiograph showed a large cavity including sloughed lung tissue, freely moving to dependent position at both lateral decubitus view. RML and RLL were resected and compression of pulmonary vessels by enlarged lymph nodes was observed. Defervescence was obtained immediate postoperative period and the patient was discharged after infection control with antibiotics, chest tube drainage. The perivascular lymph nodes dissected during lobectomy were proved to be reactive hyperplasias. We speculated that the carcinoma caused obstructive pneumonia, in turn, resulted in reactive hyperplasia of the draining lymph nodes surrounding the large vessels and finally the lung tissues supplied by them necrotized and sloughed.

  • PDF

Improvement Method of Sand Ground Using an Environmental Friendly Bio-grouting Material (친환경 바이오그라우팅을 이용한 모래지반 개량 공법)

  • Kim, Dae-Hyeon;Sagong, Myung;Park, Kyung-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.6
    • /
    • pp.473-481
    • /
    • 2013
  • The purpose of this research is to evaluate the improvements in the strength and injection range of loose ground after injecting $CaCO_3$(created by microorganism reaction). For this purpose, three cases of single-layer (Sand, SP, SW) specimens were made in a 150mm D ${\times}$ 200mm H space and two cases of multi-layer specimens (SW/SP, SP/SW) were made in a 150mm D ${\times}$ 300mm H space. The specimens were made with a relative density of 30% of soft ground and an injection was given over a time of one day. The uniaxial compression strength was measured with a cone penetrometer and the injection range was observed by checking the bulb formation around the injection nozzle. Also, the compositions of the specimens were assessed through XRD analyses. Based on the test results, a compressive strength of 500kPa and 15cm thick cementation were noted due to the cementation of the soil. This implies that there are significant effects of the pore condition and size on bio-grouting technology.