• Title/Summary/Keyword: Time Resolved

Search Result 894, Processing Time 0.03 seconds

A Generic Time-resolved Fluorescence Assay for Serine/threonine Kinase Activity: Application to Cdc7/Dbf4

  • Xu, Kui;Stern, Alvin S.;Levin, Wayne;Chua, Anne;Vassilev, Lyubomir T.
    • BMB Reports
    • /
    • v.36 no.4
    • /
    • pp.421-425
    • /
    • 2003
  • The serine/threonine protein kinase family is a large and diverse group of enzymes that are involved in the regulation of multiple cellular pathways. Elevated kinase activity has been implicated in many diseases and frequently targeted for the development of pharmacological inhibitors. Therefore, non-radioactive antibody-based kinase assays that allow high throughput screening of compound libraries have been developed. However, they require a generation of antibodies against the phosphorylated form of a specific substrate. We report here a time-resolved fluorescence assay platform that utilizes a commercially-available generic anti-phosphothreonine antibody and permits assaying kinases that are able to phosporylate threonin residues on protein substrates. Using this approach, we developed an assay for Cdc7/Dbf4 kinase activity, determined the $K_m$ for ATP, and identified rottlerin as a non-ATP competitive inhibitor of this enzyme.

Spatially and Time Resolved Optical Diagnostics for High Pressure Microdischarges

  • Pu, Yi-Kang;Zhu, Xi-Ming;Huang, Bang-Dou;Takashima, Keisuke
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.140-140
    • /
    • 2013
  • This presentation will describe recent developement in spatially and time resolved optical diagnostics for two kinds of the high pressure microdischarges. The first kind is a nanosecond pulsed discharge with two pin electrodes while the second kind is a microwave split ring resonator developed by Jeff Hopwood. Both spatially and time resolved optical emissions are collected for these two discharges and some interesting phenomena are observed. By using either the Stark broadening or a collisional radiative model for high pressure discharges, the evolution of electron density can be obtained. We will compare these different techniques for obtaining the electron density and discuss their limitations.

  • PDF

Study of a time-resolved spectroscopy using BBO crystal in pico--second time domain (BBO 결정을 이용한 피코초 영역에서 시간 분해 분광학 연구)

  • 이승묵;조기호;황성태;정창수;이범구
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.90-91
    • /
    • 2002
  • 강한 펄스 레이저가 렌즈에 의해 투명한 매질 속에 집광되면 가시광선 영역에서부터 적외선 영역에 걸친 넓은 파장대의 빛이 발생하게 되는데 이것을 White-Light Continuum이라고 한다. 비선형 결정인 $\beta$-BBO에 의해서도 넓은 영역의 백색광을 발생시킬 수 있다. 이러한 펄스 백색광은 Time-resolved spectroscopy에서의 Probe beam과 다양한 파장대의 펄스 레이저 발생 및 증폭을 위한 Seed pulse 등으로 응용되고 있다. (중략)

  • PDF

Measurement of Absorption and Scattering Coefficients of Biological Tissues by Time-Resolved Reflectance Method (시간 분해 반사율에 의한 생체조직의 흡수계수와 산란계수 측정)

  • Jeon, Kye-Jin;Park, Seung-Han;Kim, Ung;Yoon, Gil-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.499-505
    • /
    • 1997
  • A non-invasive technique to measure absorption and scattering coefficients was investigated The reflected backscattered light from the surface of phantom and biological tissue was obtained by using a time-correlated single photon counting system in pico-second time domain. The absorption and scattering coefficients were acquired by the time of peak and asymptotic behavior of the time-resolved reflectance curve and agreed well the ones that is obtained with deconvolution method It was found that the approximation method was good for biological medium to calculate optical properties due to its convenience and accuracy.

  • PDF

Time-Resolved Resonance Raman Spectroscopic Study on Metallotetraphenylporphyrins: Effects of Metal Sizes

  • 정새채;김동호;조대원;윤민중
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.657-662
    • /
    • 1999
  • The variation of Jahn-Teller(J-T) distortion imposed on various metallo- tetraphenylporphyrins(MTPPS;M=ZnⅡ,PdⅡ,PtⅡ,and RhⅢ) has been investigated by time-resolved resonance Raman spectroscopy. B1g and B2g modes of the triplet(π,π*) states for the heavy-metal porphyrins exhibit the enhancement of their intensities compared with those of 3ZnⅢTPP, while the enhancement of phenyl internal mode is reduced. These results suggest that the J-T distortion becomes manifest as the metal size increases, and consequently the porphyrin-to-phenyl ring charge transfer in the excited triplet state is inhibited.

QUANTITATIVE MONITORING OF TISSUE OXYGENATION BY TIME-RESOLVED SPECTROSCOPY

  • Yamashita, Yutaka;Oda, Motoki;Ohmae, Etsuko;Tsuchiya, Yutaka
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2101-2101
    • /
    • 2001
  • Near-infrared spectroscopy is now being used in clinical diagnosis as a non-invasive monitor of tissue oxygenation state. However, due to lack of the optical pathlength information within tissues, it is still difficult to quantitate the hemoglobin concentration with present CW techniques. Time-resolved spectroscopy (TRS), which measures temporal profiles of emerging light from tissues, enables to estimate the pathlength distribution within tissues by converting time to distance. Consequently, quantitative measurement of tissue oxygenation is possible by analyzing the data with optical diffusion equation 1) or our Microscopic Beer-Lambert law2). Time-Resolved Spectroscopy System : TRS-1O3) Our TRS-10 system consists of a three-wavelength (759, 797, 833 nm) PLP as pulsed light source, a high speed PMT with high sensitivity and three signal-processing circuits for time-resolved measurement (CFD/TAC, A/D converter and histogram memory). Optical pulse train consisting of 759, 797 and 833nm is generated by PLP at 5㎒ repetition rate and irradiated a sample through a single optical fiber. The diffuse-reflected light from the sample is collected by a bundle fiber and then detected by the PMT for single photon measurement. After being amplified by a following fast amplifier, the electrical signals for each wavelength are picked out by CFD/TAC module. Then, a signal processing circuit integrated the TRS data for each wavelength individually. The simultaneous TRS measurement for three wavelengths achieved without any optical or mechanical switch. Experiment and Results Input and detection fibers of TRS-10 were attached at the human forehead with a fiber separation of 3cm. TRS measurements were continuously performed for about 20 minutes including 2 minutes hyper ventilation. It was observed that the total hemoglobin concentration was decreasing during the hyper ventilation and recovered until 2 minutes after hyper ventilation. On the other hand, the deoxy-hemoglobin concentration began to increase after hyper ventilation and had its peak at around 2 minute later, showing 502 drop from 75% to 60% due to inhibition of breathing by performing hyper ventilation. The results showed that this system might be able to quantitate the concentrations of oxy- and deoxy-hemoglobin in the human brain.

  • PDF

Four Dimension(4D) Time Resolved Imaging of Contrast Kinetics(TRICKS) MR Angiography (4차원 영상기법 Time Resolved Imaging of Contrast Kinetics MRA의 유용성)

  • Lim, cheong-hwan;Bae, sung-jin
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1105-1110
    • /
    • 2009
  • To assess the clinical value of time resolved imaging of contrast kinetics(TRICKS) MRA by comparison with conventional time of flight(TOF) MR angiography. Both TOF-MRA and TRICKS-MRA were performed in 17 patients with cerebrovascular disease and in 6 patients with brain tumor. Among 17 cerebraovascular patients, digital subtraction angiography(DSA) data were also obtained in 11 patients. TOF-MRA showed good spatial resolution but short in temporal resolution. Although TRICKS-MRA showed somewhat low spatial resolution, it showed superior temporal resolution by distinguishing vessel and tumor in all patients. Also, from the analysis of vessel-tumor relationship, TRICKS-MRA showed better performance than TOF-MRA. TRICKS-MRA makes it possible to image arterial, capillary and venous phase sequentially with very speedy manner and therefore, the clinical use of this method is highly suggestive for future use.

  • PDF

Product-Resolved Photodissociations of Iodotoluene Radical Cations

  • Shin, Seung-Koo;Kim, Byung-Joo;Jarek, Russell L.;Han, Seung-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.267-270
    • /
    • 2002
  • Photodissociations of o-, m-, and p-iodotoluene radical cations were investigated by using Fourier-transform ion cyclotron resonance (FT-ICR) spectrometry. Iodotoluene radical cations were prepared in an ICR cell by a photoionization charge-transfer method. The time-resolved one-photon dissociation spectra were obtained at 532 nm and the identities of $C_7H_7^+$ products were determined by examining their bimolecular reactivities toward toluene-$d_8$. The two-photon dissociation spectra were also recorded in the wavelength range 615-670 nm. The laser power dependence, the temporal variation, and the identities of $C_7H_7^+$ were examined at 640 nm. The mechanism of unimolecular dissociation of iodotoluene radical cations is elucidated: the lowest barrier rearrangement channel leads exclusively to the formation of the benzyl cation, whereas the direct C-I cleavage channel yields the tolyl cations that rearrange to both benzyl and tropylium cations with dissimilar branching ratios among o-, m-, and p-isomers. With a two-photon energy of 3.87 eV at 640 nm, the direct C-I cleavage channel results in the product branching ratio, [tropylium cation]/[benzyl cation], in descending order, 0.16 for meta >0.09 for ortho >0.05 for para.

Time-resolved transient reflective image on silicon surface after single-shot fs-laser pulse irradiation (단일 펨토초 레이저펄스를 이용한 실리콘 표면에서의 시분해 반사율 측정 연구)

  • Moon, Heh-Young;Sidhu, Mehra Singh;Lee, Hyun-Kyu;Jeoung, Sae-Chae
    • Laser Solutions
    • /
    • v.14 no.4
    • /
    • pp.21-27
    • /
    • 2011
  • In this work, we have studied on time-resolved transient reflective image of single crystalline Si surface after single-shot fs-laser irradiation with varying the laser fluence under two different laser spot sizes. The temporal profiles of transient reflectivity changes as well as its maximum values at the early delay time were found to be strongly dependent on both the laser beam spot size and laser fluence. We have interpreted the dependence of transient reflectivity changes on the laser spot size in terms of a relaxation of the generated free carriers to the bulk silicon, which should be interacted with the plasma.

  • PDF