• 제목/요약/키워드: Time Domain Reflectometry

검색결과 199건 처리시간 0.036초

Microwave Dielectric Characterization of Binary Mixtures of 3-Nitrotoluene with Dimethylacetamide, Dimethylformamide and Dimethylsulphoxide

  • Chaudhari, Ajay;Chaudhari, H.C.;Mehrotra, S.C.
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권9호
    • /
    • pp.1403-1407
    • /
    • 2004
  • Dielectric relaxation measurements on 3-nitrotoluene (3-NT) mixture of dimethylacetamide (DMA), dimethylformamide (DMF) and dimethysulphoxide (DMSO) have been carried out across the entire concentration range using Time domain reflectometry technique at 15, 25, 35 and $45^{\circ}C$ over the frequency range from 10 MHz to 20 GHz. For all the mixtures, only one dielectric loss peak was observed in this frequency range and the relaxation in these mixtures can be well described by a single relaxation time using Debye model. Bilinear calibration method is used to obtain complex permittivity ${\varepsilon}^{*}({\omega})$ from complex reflection coefficient ${\rho}^{*}({\omega})$ over frequency range 10 MHz to 20 GHz. The excess permittivity, excess inverse relaxation time, Kirkwood correlation factor, molar energy of activation are also calculated for these mixtures to study the solute-solvent interaction.

Development of Calibration Model and Analysis of Soil Water Content using Time-Domain Refelctometry Probe in LTPP Sections (LTPP 구간에서 TDR 방식 함수량계를 이용한 현장함수비 보정모델 개발과 함수비 분석 연구)

  • Kim, Boo-Il;Jeon, Sung-Il
    • International Journal of Highway Engineering
    • /
    • 제7권4호
    • /
    • pp.103-112
    • /
    • 2005
  • Water content of sub-layer in pavement systems has a large effect on pavement performance. Many researchers lately make use of time-domain reflectometry(TDR) probes to measure the soil water content of sub-layer from field monitoring. The laboratory calibration test of TDR probe should be performed with soil field, because TDR probe can cause an error by type, gradation, density, and temperature of soil. This study performed the laboratory calibration test of TDR probe(CS616) with subgrade and subbase material in long term pavement performance(LTPP) sections. And the calibration equations of TDR probe(CS616) were then proposed. It was confirmed from the study that the data of TDR probe monitored in field could be used to estimate the freezing, unfrozen water content, and matric suction of soil.

  • PDF

The Implementation of Load Resistance Measurement System using Time-Frequency Domain Reflectometry (시간-주파수 영역 반사파 계측방법을 이용한 부하 저항 측정 시스템 구현)

  • Kwak, Ki-Seok;Park, Tae-Geun;Yoon, Tae-Sung;Park, Jin-Bae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • 제55권10호
    • /
    • pp.435-442
    • /
    • 2006
  • One of the most important topics about the safety of electrical and electronic system is the reliability of the wiring system. The Time-Frequency Domain Reflectometry(TFDR) is a state-of-the-art system for detecting and estimating of the fault on a wiring. In this paper, We've considered the load resistance measurement on a coaxial cable using TFDR in a way of expanded application. The TFDR system was built using commercial Pci extensions for Instrumentation(PXI) and LabVIEW. The proposed real time TFDR system consisted of the reference signal design, signal generation, signal acquisition, algorithm execution and results display part. To implement real time system, all of the parts were programmed by the LabVIEW which is one of the graphical programming languages. Using the application software implemented by the LabVIEW, we were able to design a proper reference signal which is suitable for target cable and control not only the arbitrary waveform generator in the signal generation part but alto the digital storage oscilloscope in the signal acquisition part. By using the TFDR real time system with the terminal resistor on the target cable, we carried out load impedance measurement experiments. The experimental results showed that the proposed system are able not only to detect the location of impedance discontinuity on the cable but also to estimate the load resistance with high accuracy.

Tempereture Dependent Dielectric Relaxation Study of Aniline in Dimethylsulphoxide and Dimethlformamide Using Time Domain Technique (시간분해기법을 이용한 디메틸 술폭사이드와 디메틸 포름아미드-아닐린용액에서 온도의존 유전이완에 관한 연구)

  • Chaudhari, Ajay;Patil, C.S.;Shankarwar, A.G.; Arbad, B.R.;Mehrotra, S.C.
    • Journal of the Korean Chemical Society
    • /
    • 제45권3호
    • /
    • pp.201-207
    • /
    • 2001
  • The dielectric relaxation study for aniline-dimethylsulphoxide (DMSO) and aniline-dim.ethylformamide(DMF) has been carried out using the Time domain reflectometry (TDR) technique, at different temperature and concentrations, in the frequency range of 10 MHz to 10 GHz. The dielectric parameters viz. static permittivity, relaxation time, the Kirkwood correlation factor, excess permittivity, excess inverse relaxation time and thermodynamic parameters have been obtained. The calibration method based on least squares fit method has been used. The dielectric parameters show systematic change with temperature and concentrations.

  • PDF

Quasi-Distributed Temperature Sensor Based on a V-Grooved Single-Mode Optical Fiber Covered with Ethylene Vinyl Acetate

  • Kim, Kwang Taek;Jeong, Seong-Gab
    • Journal of Sensor Science and Technology
    • /
    • 제23권4호
    • /
    • pp.229-233
    • /
    • 2014
  • In this study, a V-grooved single-mode fiber along with optical time domain reflectometry (OTDR) as a quasi-distributed temperature sensor was investigated. The external medium used to fill the V-groove affects the optical mode. The V-groove was filled with ethylene vinyl acetate (EVA) because its transmittance was sensitive to temperature. The experimental results showed that the optical loss of the sensor varies with temperature, and the sensitivity depends on the depth of the V-groove.

Detection and Localization of Neutral Wire Defect of XLPE Power Cable Based on The Time-Frequency Domain Reflectometry (시간-주파수 영역 반사파 계측법 기반 XLPE 전력 케이블의 중성선 결함 위치 측정 연구)

  • Lee, Chun-Ku;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1790-1791
    • /
    • 2011
  • In this paper, the diagnosis system for detecting and localizing the neutral wire defect in an energized XLPE power cable is proposed. The neutral wire defect is detectd and localized by the time-frequency domain reflectometry. To extract the reflected signal from the neutral wire defect, the adaptive RLS filtering is introduced. To verify the proposed method, the experiments for detecting and localizing neutral wire defect in active XLPE power cable is conducted.

  • PDF

Implementation of Coupler for Live Wire Fault Detection System using Time-Frequnecy Domain Reflectometry (커플러를 이용한 활선 상태 배선 진단 시간-주파수 영역 반사파 계측 시스템 구현)

  • Doo, Seung-Ho;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1541-1542
    • /
    • 2008
  • In this paper, we introduce a live wire power transmission line fault detection system using time-frequency domain reflectometry(TFDR). The TFDR is known that is more precise method than the other conventional ones. However, the TFDR is generally adopted only in fault detection for communication cable, and dead line power transmission line. Therefore, this paper suggests a TFDR system with coupler which separates 220V, 60Hz signal and TFDR reference signal for implementation the live wire fault detection system. This approach is verified by circuit simulation.

  • PDF

Analysis of the Time Domain Reflectometry for the Monitoring of Rock Displacement (시간 영역 반사법에 의한 암반 변위의 계측 기술 분석)

  • 정소걸
    • Tunnel and Underground Space
    • /
    • 제5권1호
    • /
    • pp.70-76
    • /
    • 1995
  • Two types of deformations can occur on the cable during the monitoring of the rock displacement by the time domain reflectometry. One is the impedance model for tensile deformation, and the other is the capacitance model for the shear deformation. The former gives a response signal with a gradual change in the amplitude of the reflected voltage, meanwhile the latter produces a signal with a blunted spike. The resolution of the TDR can be improved to 0.125% using calibration crimps on the cable of 60 meters long. It is recommended that the diameter of the cable should be 18 mm at least in order to induce a better reflected pulse without any open-circuit. The actual TDR technique cannot characterize the type and the magnitude of rock displacement quantitatively. Systematic investigation of the TDR parameters, such as the exact of cable diameter, cable length, number of crimps, combination of shearing and extension, and environment of the TDR equipment, will be able to improve the resolution to 0.01 mm.

  • PDF

A Study on the Calibrate Method of Volumetric Moisture Content Measuring Sensor(CS616) (TDR(Time Domain Reflectometry) 방식의 함수센서 (CS616) 보정방법에 관한 연구)

  • Cho, Myung-Hwan;Kim, Hong-Man;Jee, Kee-Hwan;Park, Joo-Young
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2010년도 정기 학술발표대회
    • /
    • pp.89.1-89.1
    • /
    • 2010
  • 본 연구는 토양의 함수비를 측정하기 위하여 TDR(Time Domain Reflectometry, 시간영역 광전자파 분석기) 방식의 함수센서(CS616)에 대한 올바른 보정시험을 제안하기 위하여 피복두께, 센서간 간섭 영향, 온도의 영향 및 다짐율 변화에 대한 실내 시험을 수행하였다. 시험 결과 피복두께, 센서간 간섭 영향 및 온도의 영향은 체적함수비의 크기에 미치는 영향은 크지 않은 것으로 나타났으며, 오히려 보정시험시 정확한 체적함수비 조건을 유지하는 것이 중요할 것으로 사료된다. 또한 보정시험을 수행할 때 다짐율까지 고려한 시험을 수행하는 노력에 비하여 얻어지는 체적함수비의 정확도의 크기는 다짐율과 주기를 고려하여 얻어진 회귀식을 살펴보면 주기에 비하여 상대적으로 영향이 작은 것으로 사료된다.

  • PDF