• Title/Summary/Keyword: Time Device

Search Result 5,942, Processing Time 0.028 seconds

IoT Device Testing for Efficient IoT Device Framework

  • Gong, Dong-Hwan
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.77-82
    • /
    • 2020
  • IoT devices frequently require input resources to communicate with various sensors or IoT platforms. IoT device wastes a lot of time as idle time or waiting time to check the data of the input resource and use the input resource. In addition, IoT devices use various input resources. We compares and analyzes input idle time and input waiting time generated from hardware serial input resource, software serial input resource, digital port input resource, and analog port input resource using Arduino widely used as IoT device. In order to design the IoT device framework, it is necessary to understand the characteristics of input resources and to design them to minimize unnecessary input idle time and input waiting time. The analog input wait time has a much larger input wait time than the digital input wait time, so it must be designed to receive analog information periodically at the appropriate timing. The characteristics of the input resources analyzed in this way help to design an efficient IoT device.

Development of the slitting device on separation study of pellet and hull (펠릿과 헐의 분리 연구를 위한 슬리팅 장치 개발)

  • 정재후;윤지섭;홍동희;김영환;진재현;박기용
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.236-239
    • /
    • 2003
  • The spent fuel slitting device is an equipment developed in order to feed UO$_2$pellet to the dry pulverizing/mixing device. In this study, we have compared and analyzed the handling method of the slitting and that of the pellet and hull, processing time, separating time for 20kgHM, the number of blades, on the existing slitting device using in DUPIC, and spent fuel management technology research and test facility. Also, we have compared and analyzed about an advantage and weak point, designing and producing, processing, establishment, operation, maintenance about the vertical and horizontal slitting device. Based on these results, we have developed the vertical slitting device. By using the results, we have enhanced the slitting processing time(over 40%)in comparison with DUPIC device, and it will is effectively applied to available data for designing and producing of the hot test facility.

  • PDF

Optical Bistable Device Using Poistive Electro-Optic Feedback (전기광학적 정궤환을 이용한 광쌍안정소자)

  • 이창희;김석윤;갑상영;이수영
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.1
    • /
    • pp.94-100
    • /
    • 1988
  • To improve the switching time of active optical bistable devices, we propose an active optical bistable device that consists of a diode laser, a transistor, and a photodetector. By implementing the proposed device we realize the optical bistable device with a 5 nanosecond switching time. This is the fastest switching time among the hybrid type optical bistable devices. It is also experimentally demonstrated that the proposed device may be used in an optical disc pick up.

  • PDF

A Study On Development Train Reach Spare Time Indicate Device At The Railway Level Crossing (철도건널목 열차도달 잔여시간 표시장치 개발 연구)

  • 박기범;장우진;최규형
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.117-124
    • /
    • 2002
  • Fixed distance control system at the railway level crossing have some problem. The problem is especially serious for high speed or low speed train. Therefore present developed device is fixed time control system. But fixed time control system haven't indicate device when train reach at the railway level crossing on alarm. This paper' result in study for train reach spare time indicate device.

  • PDF

Comparison of Lane Curing Time using Natural Drying and Line Drying Device when Painting Pavements on Highways (고속도로에서 차선도색시 자연건조 및 열풍기 사용시의 차선 양생시간 비교)

  • Hong, Su-Jeong;Oh, Heung-Un
    • International Journal of Highway Engineering
    • /
    • v.20 no.4
    • /
    • pp.35-46
    • /
    • 2018
  • PURPOSES : The purpose of this study is to compare the lane curing time of natural drying and a lane drying device when painting lines on a highway. METHODS : The painting process was carried out in July 2015 and September 2015, respectively, for the Gimcheon IC - Gimcheon JC. After the painting, measurements were obtained three times at six measurement points located at 20 m intervals on the shoulder line and the dividing line. The curing time was measured for natural drying and drying using a lane drying device, and compared for different pavement types (asphalt, concrete) and paint types (waterborne paint, methyl methacrylate paint). RESULTS : The results of the lane curing time comparison on the highway are as follows. The combination of asphalt and methyl methacrylate paint cured more rapidly during both the natural drying and drying using the lane drying device. Finally, it was cured at least 32.2% and 40.7% faster when using a drying device than in natural drying. CONCLUSIONS : The comparison of lane curing time of the highway showed that the combination of asphalt and methyl methacrylate paint cured more rapidly when using both natural drying and a lane drying device.

A Study on how to Utilize the DR System using Assistive Devices (보조기구를 이용한 DR System 활용 방법에 대한 연구)

  • Seon-Yeol, Seo;Jeong-Ho, Kim;Jin-Ok, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • The hip joint device is an important immobilization device for internal rotation in the diagnosis of bone density test, microfracture, and arthritis. These fixing mechanisms have limitations in maintaining reproducibility due to the use of Velcro. In this study, we developed an improved hip joint device and evaluated its usefulness. For 30 students enrolled in the Department of Radiology, we evaluated the reproducibility through medical imaging and the time required for positioning by applying the conventionaling and improved device. Changes over time were also evaluated. As a result, compared to the conventional device, the improved device showed a 32% reduction in positioning time and improved reproducibility by about 6.2 times. As for the amount of change over time, the positioning time increased in the conventional device, but decreased in the improved device, and the reproducibility of the conventional device was lower than that of the improved device. Through this, it can be said that the use of the improved device improved the image quality and reduced the radiologist's workload.

Development of a Low -Cost and Precise Liquid Metering Device for Automatic Nutrient-Solution Control (양액 자동조제용 액제 정밀계량 장치 개발)

  • 이정훈;류관희;이규철
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.12a
    • /
    • pp.255-262
    • /
    • 1997
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. Those parts were controlled by personal computer with time-based odoff control method. To verify the performance of the developed metering device, the relationship between operating time and discharge was examined and the accuracy of the developed metering device was compared with commercial metering pumps. The results of this study are as follows. 1. The correlation coefficient between the flow rate and operating time was 0.9999, and the linear regression equation computed was y=21.759x, where y is the discharge(g) and x is the operating time(s). 2. The developed device has greater accuracy than commercial metering pumps in terms of the full-scale error. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3 %, $\pm$2.45 % and $\pm$1.38 % respectively. 3. Above results show developed metering device is a useful tool for nutrient-solution control system.

  • PDF

Development of Ignitor of Open-Type Propulsion Device for Korean Interceptor (대응탄 개방형 추진장치용 점화기개발)

  • Kwon, Soon-Kil;Kim, Chang-Kee;Yun, Sang-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1166-1170
    • /
    • 2011
  • For developing the ignition device for the interceptor of Korean active protection system, the design parameters of the ignition device which should have a short ignition delay time and sufficient energy for propellant ignition were studied. The electric primer instead of mechanical primer was adopted for deceasing delay time, and ignition code was used for decreasing the time difference of flame propagation from the flame holes. The developed ignition device showed the ignition delay time of a few ms. When the designed ignition device was applied to the open-type propulsion devices, the stable interior ballistic characteristic was showed in a firing test.

Comparison of Accuracy and Output Waveform of Devices According to Rectification Method (정류방식에 따른 장치의 정확도와 출력 파형의 비교)

  • Lee, In Ja
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

EPD time delay in etching of stack down WSix gate in DPS+ poly chamber

  • Ko, Yong Deuk;Chun, Hui-Gon
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.130-136
    • /
    • 2002
  • Device makers want to make higher density chips as devices shrink, especially WSix poly stack down is one of the key issues. However, EPD (End Point Detection) time delay was happened in DPS+ poly chamber which is a barrier to achieve device shrink because EPD time delay killed test pattern and next generation device. To investigate the EPD time delay, a test was done with patterned wafers. This experimental was carried out combined with OES(Optical Emission Spectroscopy) and SEM (Scanning Electron Microscopy). OES was used to find corrected wavelength in WSix stack down gate etching. SEM was used to confirm WSix gate profile and gate oxide damage. Through the experiment, a new wavelength (252nm) line of plasma is selected for DPS+ chamber to call correct EPD in WSix stack down gate etching for current device and next generation device.

  • PDF