• Title/Summary/Keyword: Time Determination

Search Result 2,981, Processing Time 0.026 seconds

Determination of Polonium Nuclides in a Water Sample with Solvent Extraction Method

  • Lee, M.H.;Lee, C.H.;Song, K.;Kim, C.K.;Martin, P.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.9
    • /
    • pp.2488-2492
    • /
    • 2010
  • A method is described for the determination of the Po nuclides in a water sample. After the Po nuclides were purified from interfering elements in a water sample using a manganese dioxide precipitation followed by a solvent extraction method, the Po nuclides were deposited onto the silver plate. A large volume of the water sample was effectively pretreated with manganese dioxide precipitation method. To determine the optimum conditions for plating Po, the effects of the pH, volume, temperature and time on the Po deposition were investigated in hydrochloric acid solution. The investigated determination method of Po nuclides with solvent extraction was applied to a tap water sample.

Routing Service Implementation using a Dual Graph (듀얼 그래프를 이용한 라우팅 서비스 구현)

  • 김성수;허태욱;박종현;이종훈
    • Proceedings of the IEEK Conference
    • /
    • 2003.11b
    • /
    • pp.171-174
    • /
    • 2003
  • Shortest path problems are among the most studied network flow optimization problems, with interesting applications in various fields. One such field is the route determination service, where various kinds of shortest path problems need to be solved in location-based service. Our research aim is to propose a route technique in real-time location-based service (LBS) environments according to user's route preferences such as shortest, fastest, easiest and so on. Turn costs modeling and computation are important procedures in route planning. We propose a new rest modeling method for turn costs which are traditionally attached to edges in a graph. Our proposed route determination technique also has an advantage that can provide service interoperability by implementing XML web service for the OpenLS route determination service specification.

  • PDF

Determination of Ammonia-N in Environmental Water by Air-segmented FIA

  • Feng, Yong-Lai;Tian, Li-Ching;Wang, Wei;Wu, Qiao-Znen
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.787-792
    • /
    • 1995
  • A method for determination of ammonia-N in environmental water by air-segmented flow injection analysis using the colour reaction of phenol and sodium hypochlorite with ammonia was described in this paper. When the reaction temperature is $70^{\circ}C$ and the reaction residence time is 5 minutes, a sample frequency of $60-90h^{-1}$ can be achieved. The detection limit and relative deviation are $0.05mg.ml^{-1}$ and 4%, respectively. The recovery of this method is 96 - 110%, and the determination results of the method are greatly agreement with standard colorimetric method.

  • PDF

A Study on the Attitude Determination of the KOMPSAT (다목적 실용 위성의 자세결정에 관한 연구)

  • Kim, Byung-Doo;Lee, Ja-Sung;Choi, Wan-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.474-477
    • /
    • 1997
  • In this paper, an efficient attitude determination algorithm based on the Kalman Filter which combines earth/sun sensor data with gyro data in a mutually compensating manner is presented. Quaternion is used as the attitude state to save computation time and to prevent the gimbal-lock situation associated with Euler angles. Gyro data allows the use of the kinematic equation instead of space vehicle's dynamic equation which is usually based on approximation of the actual dynamics and inaccurate torque information. The gyro data are used to propagate the attitude through kinematic equation and the earth/sun sensor data are used to update the attitude and estimate the gyro bias. Simulation results for the KOMPSAT attitude determination system are presented.

  • PDF

Two Bayesian methods for sample size determination in clinical trials

  • Kwak, Sang-Gyu;Kim, Dal-Ho;Shin, Im-Hee;Kim, Ho-Gak;Kim, Sang-Gyung
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.6
    • /
    • pp.1343-1351
    • /
    • 2010
  • Sample size determination is very important part in clinical trials because it influences the time and the cost of the experimental studies. In this article, we consider the Bayesian methods for sample size determination based on hypothesis testing. Specifically we compare the usual Bayesian method using Bayes factor with the decision theoretic method using Bayesian reference criterion in mean difference problem for the normal case with known variances. We illustrate two procedures numerically as well as graphically.

Determination of $\alpha$--pyrrolidone in panax ginseng Extracts (인삼 extract중의 $\alpha$-pyrrolidone검정)

  • 서정상
    • YAKHAK HOEJI
    • /
    • v.13 no.4
    • /
    • pp.111-120
    • /
    • 1969
  • The determination of $\alpha$-pyrrolidone in ginseng extract by gas liquid chromatography (GLC) was established. $\alpha$-Pyrrolidone in extract was tentatively identified by comparison of the relative retention time of sample peak with those of reference compound and coinjection noted peak enhancement. The .alpha.-pyrrolidone peak elimination was demonstrated by formation of oxime when treated with excess of NH$_{2}$OH ${\cdot}$ HCl and NaOH, allowed to stand at room temperature for 5 minute. The elimination was also observed when samples were treated by the same procedure. The above method was proved to be useful for the determination of $\alpha$-pyrrolidone in ginseng extract and in ginseng extract mixed with 51 plant extracts.

  • PDF

Determination of Cyanide Ion by Adsorptive Stripping Voltammetry (흡착벗김 전압전류법에 의한 시안화이온의 정량)

  • Cha, Ki-Won;Ko, Su-Jin;Kim, Jea-Kyun
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.540-544
    • /
    • 2001
  • Determination of cyanide ion has been studied by adsorptive stripping voltammetry using hanging mercury electrode. Cyanide ion complexed with copper ion is adsorpbed on the electrode and oxidised at the positive potential scan. Optimal conditions of CN determination were found to be ; supporting electrolyte solution ; 0.1 M NaCl of ammonium buffer at pH 10, accumulation potential; -800 mV vs Ag/AgCl, accumulation time ; 300 s, scan rate ; 50mV/s. The linear concentration of cyanide ion was observed in the range $1{\times}10^{-8}$, $1{\times}10^{-7}M$. The detection limit(n/s=3) was $0.13{\mu}g/L$($5{\times}10^{-9}M$) with 3.5% RSD.

  • PDF

Automated Control Gain Determination Using PSO/SQP Algorithm (PSO/SQP를 이용한 제어기 이득 자동 추출)

  • Lee, Jang-Ho;Ryu, Hyeok;Min, Byoung-Moom
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 2008
  • To design flight control law of an unmanned aerial vehicle, automated control gain determination program was developed. The procedure for determination of control gain was formulated as the control gains were designed from the optimal solutions of the optimization problem. PSO algorithm, which is one of the evolutionary computation method, and SQP algorithm, which is one of the nonlinear programming method, are used as optimization problem solver. Thru this technique, computation time required for finding the optimal solution is decreased to 1/5 of that of PSO algorithm and more accurate optimal solution is obtained.

  • PDF

Automatic Determination of Coagulant Dosing Rate Using Fuzzy Neural Network (Fuzzy Neural Network에 응집제 투입률의 자동결정)

  • Chung, Woo-Seop;Oh, Sueg-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.1
    • /
    • pp.101-107
    • /
    • 1997
  • Recently, as the raw water quality becomes to be polluted and the seasonal and local variation of water quality becomes to be severe, an exact control of coagulant dosing have been required in the water treat- ment plant. The amounts of coagulant is related to the raw water quality such as turbidity, alkalinity, water temperature, pH and edectrical conductivity. However the process of chemical reaction has not been clarified so far, so the dosing rate has been decided by jar-test, which is taken one or two hours. For the sake of this coagulant dosing control, fuzzy neural network to fuse fuzzy logic and neural network was proposed, and the scheme was applied to automatic determination of coagulant dosing rate. This controller can automatically identify the if-then rules and tune the membership functions by utilizing expert's cintrol data. It is shown that determination of coagulant dosing rate according to real time sensing of water quality is very effect.

  • PDF

Analysis of Characteristics of All Solid-State Batteries Using Linear Regression Models

  • Kyo-Chan Lee;Sang-Hyun Lee
    • International journal of advanced smart convergence
    • /
    • v.13 no.1
    • /
    • pp.206-211
    • /
    • 2024
  • This study used a total of 205,565 datasets of 'voltage', 'current', '℃', and 'time(s)' to systematically analyze the properties and performance of solid electrolytes. As a method for characterizing solid electrolytes, a linear regression model, one of the machine learning models, is used to visualize the relationship between 'voltage' and 'current' and calculate the regression coefficient, mean squared error (MSE), and coefficient of determination (R^2). The regression coefficient between 'Voltage' and 'Current' in the results of the linear regression model is about 1.89, indicating that 'Voltage' has a positive effect on 'Current', and it is expected that the current will increase by about 1.89 times as the voltage increases. MSE found that the mean squared error between the model's predicted and actual values was about 0.3, with smaller values closer to the model's predictions to the actual values. The coefficient of determination (R^2) is about 0.25, which can be interpreted as explaining 25% of the data.