• 제목/요약/키워드: Time Conversion

검색결과 2,156건 처리시간 0.025초

Fast Coordinate Conversion Method for Real-time Weather Radar Data Processing

  • Jang, Bong-Joo;Lim, Sanghun;Kim, Won
    • Journal of Multimedia Information System
    • /
    • 제5권1호
    • /
    • pp.1-8
    • /
    • 2018
  • The coordinate system conversion of weather radar data is a basic and important process because it can be a factor to measure the accuracy of radar precipitation rate by comparison with the ground rain gauge. We proposed a real-time coordinate system conversion method that combines the advantages of the interpolation masks of SPRINT and REORDER to use tables of predetermined radar samples for each interpolated object coordinate and also distance weights for each precomputed sample. Experimental results show that the proposed method improves the computation speed more than 20~30 times compared with the conventional method and shows that the deterioration of image quality is hardly ignored.

Optimal equivalent-time sampling for periodic complex signals with digital down-conversion

  • Kyung-Won Kim;Heon-Kook Kwon;Myung-Don Kim
    • ETRI Journal
    • /
    • 제46권2호
    • /
    • pp.238-249
    • /
    • 2024
  • Equivalent-time sampling can improve measurement or sensing systems because it enables a broader frequency band and higher delay resolution for periodic signals with lower sampling rates than a Nyquist receiver. Meanwhile, a digital down-conversion (DDC) technique can be implemented using a straightforward radio frequency (RF) circuit. It avoids timing skew and in-phase/quadrature gain imbalance instead of requiring a high-speed analog-to-digital converter to sample an intermediate frequency (IF) signal. Therefore, when equivalent-time sampling and DDC techniques are combined, a significant synergy can be achieved. This study provides a parameter design methodology for optimal equivalent-time sampling using DDC.

한국형 환자분류도구-1(KPCS-1)의 신뢰도와 타당도 검증 및 간호시간 환산지수 산출 (Verification of Reliability and Validity of KPCS-1 and Estimation of Nursing Time Conversion Index)

  • 송경자;김은혜;유정숙;박현애;송말순;박광옥
    • 임상간호연구
    • /
    • 제16권2호
    • /
    • pp.127-140
    • /
    • 2010
  • Purpose: This study was performed to verify reliability and validity of Korean Patient Classification System for nurses(KPCS-1), to estimate nursing time conversion index, and to classify patients into groups according to KPCS-1 scores. Methods: KPCS-1 was revised from KPCS by a professional review team. Interrater reliability and construct validity of KPCS-1 were verified by data from 433 patients. Direct and indirect nursing time of 204 patients were measured by stopwatch observation and self reports for 24 hours. Nursing time conversion index was calculated. Results: KPCS-1 consisted of 12 area, 50 nursing activities, and 73 items. The interrater reliability was tested between two nurse group (r=.88, p<.001) and construct validity was verified according to medical department (F=10.97, p<.001) and patient pattern (F=5.54, p=.001). The correlation of nursing time and classification score was also statistically significant (r=.56, p<.001). The nursing time conversion index was 9.03 minutes per 1 classification score. The patients were classified into 4 groups by the classification scores. Conclusion: KPCS-1 can be a useful factor type patient classification system for general ward. Further study is needed to evaluate validity and reliability for refining KPCS-1 and to develop ways connecting the scores with nursing outcomes.

수종 광중합 복합 레진의 중합 깊이와 광조사 시간에 따른 중합률에 관한 연구 (A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE DEPTH OF CURE AND LIGHT CURING TIME)

  • 김경현;권오승;김현기;백규철;엄정문;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.35-60
    • /
    • 1997
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc, depend on the degree of conversion of the resin components. The clinical behavior of restorative resins varies brand to brand. Part of this variation is associated with the filler and differences in the polymer matrix. The polymer matrix of resins may differ because the involved monomers are dissimilar and because of variation in the catalyst system. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the depth of cure and light curing time. 7mm diameter cylindrical aluminum molds were filled with each of five different hybrid light curing composite resins(Z-100, Charisma, Herculite XRV, Prisma TPH, Veridonfil) on the thin resin films. The molds were 1mm, 2mm, 3mm, 4mm, and 5mm in depth to produce resin films of various heights. Each sample was given 20sec, 40sec, and 60sec illumination with a light source. The degree of conversion of carbon double bonds to single bonds in the resin films was examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows; 1. There was difference in the degree of conversion among five light curing composite resins according to the depth of cure for 20sec, 40sec, and 60sec illumination with light source with statistical significance(P<0.05). 2. Five light curing composite resins show lower degree of conversion at surface of the resin than depth of 1mm. 3. The degree of conversion of five light curing composite resins was siginificantly reduced from the maximum for the resin film when the light passed through as little as 1mm of each composite. 4. The degree of conversion of five light curing composite resins decrease significantly at the depth of 4mm, and polymerization was not occured at the depth of 5mm except for Prisma TPH. 5. The degree of conversion of five light curing composite resins was increased with increased light curing time, and there was no significant differences in the degree of conversion above 4mm in Z-100, 3mm in Charisma, and at depth of 5mm in Herculite XRV and Veridonfil(P>0.05).

  • PDF

잠재적 시간 오차에 따른 현휘의 발생 방지를 위한 최적 블라인드 제어 (Optimum Blind Control to Prevent Glare Considering Potential Time Error)

  • 성윤복
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.74-86
    • /
    • 2012
  • For the improvement of environmental comfort in the buildings with the blind control, the objective of this study is to prevent the direct glare caused by the daylight inlet. During the process of solar profile prediction, time are significant factors that may cause error and glare during the blind control. This research proposes and evaluates the correction and control method to minimize prediction error. For the local areas with different longitude and local standard meridian, error occurred in the process of the time conversion from local standard time to apparent solar time. In order to correct error in time conversion, apparent solar time should be recalculated after adjusting the day of year and the equation of time. To solve the problems by the potential time errors, control method is suggested to divide the control sections using the calibrated fitting-curve and this method is verified through simulations. The proposed correction and control method, which considered potential time errors by loop lop leap years, could solve the problems about direct glare caused by daylight inlet on the work-plane according to the prediction errors of solar profile. And also these methods could maximize daylight inlet and solar heat gain, because the blocked area on windows could be minimized.

Real-Time 2D-to-3D Conversion for 3DTV using Time-Coherent Depth-Map Generation Method

  • Nam, Seung-Woo;Kim, Hye-Sun;Ban, Yun-Ji;Chien, Sung-Il
    • International Journal of Contents
    • /
    • 제10권3호
    • /
    • pp.9-16
    • /
    • 2014
  • Depth-image-based rendering is generally used in real-time 2D-to-3D conversion for 3DTV. However, inaccurate depth maps cause flickering issues between image frames in a video sequence, resulting in eye fatigue while viewing 3DTV. To resolve this flickering issue, we propose a new 2D-to-3D conversion scheme based on fast and robust depth-map generation from a 2D video sequence. The proposed depth-map generation algorithm divides an input video sequence into several cuts using a color histogram. The initial depth of each cut is assigned based on a hypothesized depth-gradient model. The initial depth map of the current frame is refined using color and motion information. Thereafter, the depth map of the next frame is updated using the difference image to reduce depth flickering. The experimental results confirm that the proposed scheme performs real-time 2D-to-3D conversions effectively and reduces human eye fatigue.

국내 광전기화학 수소생산의 경제성 평가 (Economic Evaluation of Domestic Photoelectrochemical Hydrogen Production)

  • 김봉진;김종욱
    • 한국수소및신에너지학회논문집
    • /
    • 제21권1호
    • /
    • pp.64-71
    • /
    • 2010
  • This paper deals with an economic evaluation of domestic immersing type photoelectrochemical hydrogen production. We also make some sensitivity analysis of hydrogen production prices by changing the values of input factors such as the initial capital cost, the solar to hydrogen conversion efficiency, and the system duration time. The hydrogen production price of the immersing type photoelectrochemical system was estimated as 8,264,324 won/$kgH_2$. It is expected that the production cost by photoelectrochemical hydrogen production can be reduced to 26,961 won/$kgH_2$ if the solar to hydrogen conversion efficiency is increased to 14%, the system duration time is increased to 20,000 hours, and the initial capital cost is decreased to 10% of the current level. The photoelectrochemical hydrogen production is evaluated as uneconomical at this time, and we need to enhance the solar to hydrogen conversion efficiency and the system duration time as well as to reduce prices of the system facilities.

Performance of Column Type Bioreactor Packed with Immobilized Cyclodextrin Glucanotransferase for Cyclodextrin Production

  • Lee, Yong-Hyun;Lee, Sang-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • 제1권1호
    • /
    • pp.63-69
    • /
    • 1991
  • Performance of column type bioreactor packed with immobilized cyclodextrin glucanotransferase (CGTase) on chitosan and Amberite IRA 900 was evaluated for cyclodextrin(CD) production. For CGTase immobilized on chitosan, the maximum CD conversion yield of 42% was achieved at the range of 88-168 units of immobilizied CGTase per gram of chitosan, retention time of 0.3 hr, and from 5.0% (w/v) of partially cyclized soluble starch. On the other hand, for CGTase immobilized on Amberite IRA 900, the maximum conversion yield of 40% was obtained at the range of 3.6-11.0 units of immobilized CGTase per gram of carrier and retention time of 1.2 hr from 5.0% of substrate. Above CD conversion yields are almost identical level with that can be obtained with soluble CGTase of 47%. The productivities of bioreactor packed with immobilized CGTase were 17.0g of CD/lㆍhr for amberite IRA 900 and 15.5g of CD/lㆍhr for chitosan. The partially cyclized starch with soluble CGTase were more suitable as substrate to achieve better CD conversion yield, and 5% (w/v) of partially cyclized soluble starch containing 10% (w/w) of CD was found to be most suitable to obtain maximum CD conversion yield.

  • PDF

Super-High Speed Photo detection through Frequency Conversion for Microwave on Optical Network

  • Choi, Young-Kyu;Shin, Sang-Yeol
    • Journal of information and communication convergence engineering
    • /
    • 제6권4호
    • /
    • pp.439-443
    • /
    • 2008
  • It is shown that even if the modulating frequency of the light is too high for direct detection the signal can be extracted by frequency conversion at the same time as the detection by means of the nonlinearity of the APD. When this frequency conversion detection is applied to an optical receiver, the detection bandwidth can be increased while the configuration of the optical detection circuit and the signal processing in the subsequent stages are simplified. A fundamental analysis is carried out with an APD which is confirmed experimentally.

Audio Sampling Rate Conversion Block의 설계 (Design of Audio Sampling Rate Conversion Block)

  • 정혜진;심윤정;이승준
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.827-830
    • /
    • 2003
  • This paper proposes an area-efficient FIR filter architecture for sampling rate conversion of hi-fi audio data. Sampling rate conversion(SRC) block converts audio data sampled at 96KHz down to 48KHz sampled data and vice versa. 63-tap FIR filter coefficients have been synthesized that gives 100dB stop band attenuation and 5.2KHz transition bandwidth. Time-shared filter architecture requires only one multiplier and accumulator for 63-tap filter operation. This results in huge hardware saving of up to 10~19 times smaller compared with traditional FIR structure.

  • PDF