• 제목/요약/키워드: Tilting Chair

검색결과 15건 처리시간 0.017초

전정기능 평가를 위한 탈수직축 회전자극 시스템 및 HMD 시스템의 개발 (Development of the Off-vertical Rotary Chair and Visual Stimulation system for Evaluation of the Vestibular Function)

  • 김규겸;고종선;박병림
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.377-380
    • /
    • 2001
  • The vestibular system located in the inner ear controls reflex body posture and movement. It has the semicircular canals sensing an angular acceleration and the otolith organs sensing a linear acceleration. With this organic signal, medical doctor decide if a person has disease or not. To obtain this data, a precision stimular system is considered. Robust control is needed to obtain eye signals induced by off-vertical axis rotation because of an unbalanced load produced by tilting the axis of the system upto 30 degrees. In this study, off-vertical axis rotatory system with visual stimulation system are developed. This system is consisted of head mounted display for generating horizontal, vertical, and three dimensional stimulus patterns. Furthermore wireless recording system using RF modem is considered for noiseless data transmission.

  • PDF

전력전자 기술을 응용한 의료장비 개발 사례 (Example Development of Medical Equipment Applying Power Electronics Technique)

  • 고종선;이태훈;김영일;김규겸;박병림
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.524-530
    • /
    • 2002
  • 일상 생활에서 반사적인 자세 조절은 정전기관, 시각, 고유수용체 등의 감수체에 의한 구심성 신호가 정전 신경핵에 전달되어 안구운동이나 골격근의 수축을 유발하여 이루어진다. 자세조절기능의 부조화는 오심, 구토, 현기증 등을 초래하여 삶의 의욕을 상실하게 만든다. 본 연구의 목적은 정전기관의 반규관과 이석기관을 선별적으로 자극하기 위한 탈수직축 회전자극 시스템과 수평, 수직, 3D 환경에서 시각자극을 할 수 있는 시운동자극시스템을 개발하여 인간의 자세조절 기능을 평가 하는데 있다. 탈수직축 회전자극 시스템은 편안한 의자와 DC 서보모터로 구동되는 기울임 테이블로 구성되고 PMSM에 의해 제어된다. 그리고 속도 궤환 루프와 위치 궤환 루프를 포함하는 이중 피드백 루프가 서보 제어되는 회전자극시스템에 적용된다. HMD를 이용하여 수평, 수직, 3D 시각자극패턴을 구현 하였고 OKN 자극을 위한 무선시스템과 전기안진 기록계를 이용하여 안구운동을 기록하였다. 이득, 위상, 대칭성은 정전 자극과 시각 자극에 의해 유발되는 안구운동의 분석으로부터 얻어진다.

전력전자 기술을 응용한 의료장비 개발 사례 (Example Development of Medical equipment applying Power Electronics Technique)

  • 고종선;이태훈;김영일;김규겸;박병림;김민선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.661-664
    • /
    • 2002
  • A control of the body posture and movement is maintained by the vestibular system, vision, and proprioceptors. Afferent signals from those receptors are transmitted to the vestibular nuclear complex, and the efferent signals from the vestibular nuclear complex control the eye movement. The postural disturbance caused by loss of the vestibular function results in nausea, vomiting, vertigo and loss of craving for life. The purpose of this study is to develop a off-vertical rotatory system for evaluating the function of semicircular canals and otolith organs, selectively, and visual stimulation system for stimulation with horizontal, vertical and 3D patterns. The Off-vertical axis rotator which stimulates semicircular canals and otolith organs selectively is composed of a comportable chair, a DC servo-motor with reducer and a tilting table controlled by PMSM. And a double feedback loop system containing a velocity feedback loop and a position feedback loop is applied to the servo controlled rotatory chair system. Horizontal, vertical, and 3D patterns of the visual stimulation for applying head mounted display are developed. And wireless portable systems for optokinetic stimulation and recording system of the eye movement is also constructed. The Gain, phase, and symmetry is obtained from analysis of the eye movement induced by vestibular and visual stimulation. Detailed data were described.

  • PDF

사무용 의자의 조인트 구조에 따른 등판 반발력 분석 (Evaluating the Reaction Force of Office Chair Backrest for Different Joint Structures)

  • 형준호;김사엽;노종련;박성빈;정경렬
    • 대한기계학회논문집B
    • /
    • 제39권6호
    • /
    • pp.535-540
    • /
    • 2015
  • 등판이 기울어지는 사무용 의자에서 등판 회전축 위치를 인체의 엉덩관절에 일치시키면 인체와 등판이 일체화되어 기울어짐으로써 사용성을 향상시킬 수 있다. 그러나 등판 힌지가 외부로 돌출되지 않도록 하기 위해 적용되는 핀인슬롯 조인트에서 기구적인 마찰이 발생해 등을 기울이고 세우는 동안 사용자에 영향을 줄 것으로 예상된다. 본 연구에서는 마찰 정도가 다른 조인트 부품으로서 슬라이더, 롤러 그리고 베어링 세 가지 유형을 적용하고, 등판 기울임 시 대비 복귀 시의 반발력 비율을 측정하였다. 실험 결과 베어링, 롤러, 슬라이더를 적용한 경우 등판 반발력 비율은$[{\pm}SD]$은 각각 $59.7[{\pm}10.3]%$, $47.2[{\pm}13.6]%$, $30.3[{\pm}18.1]%$로 나타나 베어링을 적용할 경우 마찰이 가장 작았다. 그러나 각 부품들은 생산단가 측면에서 차이를 보이기 때문에 부품 선정 시 마찰감소 성능뿐만 아니라 사용자의 주관적인 만족도를 함께 고려할 수 있음을 제시하였다.

전정기능 평가를 위한 탈수직축 회전자극 시스템 및 HMD 시스템의 개발 (Development of the off-vertical rotatory chair and visual stimulation system for evaluation of the vestibular function)

  • 김규겸;고종선;박병림;김인동
    • 전력전자학회논문지
    • /
    • 제6권4호
    • /
    • pp.325-332
    • /
    • 2001
  • 전징기관은 내이에 존재하며 유연한 동작과 몸의 자세 그리고 운동을 조절한다. 이 기관은 회진 가속도를 감지하는 세반고리관과 선형 가속을 감지하는 이석기관으로 구성된다. 이러한 기관의 생체 신호로부터 의사는 사람이 환자인지를 판단한다. 이 신호의 데이터를 얻기 위해서 회전의자 한쪽을 들어올려 최대 30도까지 기울인 상태에서, 회전제어하게 되는데, 이 경우 부하의 불균형으로 인한 불평형 부하를 제거하고, 생체신호의 측정을 위하여 robust제어가 요구된다. 본 연구에서는 자세조절기능에 대한 이석기관의 역할을 추구하기 위하여 탈수직축 회전자극기를 개발하였으며, 공간을 차지하고 다양한 시각패턴을 만들지 못하는 기존 시각자극시스템의 단점을 해결하기 위하여 HMD를 이용한 시각자극 시스템을 개발하였다. 더구나 노이즈에 취약한 아날로그 신호인 ENG신호의 전송문제를 해결하기 위하여 근거리 R/F 무선시스템으로 개발하였다. 이상의 제안된 시스템을 제작하고 실험한 결과를 보고하였다.

  • PDF