• Title/Summary/Keyword: Tilting Center

Search Result 128, Processing Time 0.026 seconds

The Effect of Pelvic Tilting and the Valsalva Maneuver on Electromyographic Activity of Erector Spinae During Squat Lifting and Lowering (골반경사방향과 발잘바기법이 물건 들어 올리기와 내리기 시 척추기립근의 활동전위에 마치는 영향)

  • Roh, Jung-Suk;Yi, Chung-Hwi;Chung, Bo-In;Lee, Young-Hee
    • Physical Therapy Korea
    • /
    • v.5 no.1
    • /
    • pp.30-43
    • /
    • 1998
  • The purposes of this study were to examine the effect of two different pelvic alignments and the Valsalva maneuver on electromyographic (EMG) activity of the erector spinae during squat lifting and lowering, and to find an efficient method for squat lifting and lowering. Twenty hea1thy men in their twenties lifted and lowered loads using four different methods: 1) anterior pelvic tilt position with the Valsalva maneuver, 2) anterior pelvic tilt position without the Valsalva maneuver, 3) posterior pelvic tilt with the Valsalva maneuver, 4) posterior pelvic tilt without the Valsalva maneuver. The EMG activity of erector spinae was recorded during both lifting and lowering with each method. The EMG activity of each individual was normalized to EMG activity produced by muscle during maximal voluntary contraction. Two-way analysis of variance for repeated measures ($2{\times}2$) was used to analyze the effect of the two factors: 1) pelvic tilt position (anterior pelvic tilt, posterior pelvic tilt), 2) the Valsalva maneuver (with and without). Analysis was performed separately for the lifting and lowering. The results were as follows: 1) EMG activity of erector spinae was greater when the pelvis was tilted anteriorly than when the pelvis was tilted posteriorly during squat lifting and squat lowering. 2) There was no difference between EMG activity of erector spinae with the Valsalva maneuver and EMG activity of erector spinae without the Valsalva maneuver during squat lifting and squat lowering. These results suggest that the greater EMG activity of erector spinae with an anterior pelvic tilt position during squat lifting and squat lowering may ensure optimal muscular support for the spine while handling loads, but the Valsalva maneuver may have less effect on erector spinae.

  • PDF

A proposal of the Optimal Angle of Standing Assistant Chair for the Elderly by Comparing of Pressure Distribution on Hip (둔부의 압력분포 비교를 이용한 고령자용 기립보조의자의 기립 최적각도 제안)

  • Chang, Sung-Ho;Baek, Ji-Hoon;Lee, Jung-Eon;Mirazamjon, Nematov;Kang, Seok-Wan;Lee, Wang-Bum
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.3
    • /
    • pp.108-114
    • /
    • 2018
  • One of the most performed action in daily life is standing up from sitting position. As the population of the world is aging at the high rates, people may face problems with reduced muscle strength as well as psychological changes. This can lead elderly people having difficulties with standing up from chair. Now, with the aging trend worldwide, products are being developed that can support the lives of the elderly. This study examines the distribution of hip pressure in relation to the seating positions of the standing assistance seats under development to prevent standing up accidents in older adults. The currently developing standing assistant chair designed to tilt to a maximum angle of 25 degrees. At over $25^{\circ}$, design considers that older people are at risk of thrown back out of that force and that the forces exerted on their arms and legs can be a significant burden to older people. By considering danger of higher than $25^{\circ}$ for older people which is experimented in the basis of static capturing approach in previous papers, it is experimented people with age group of 20~60 on $0^{\circ}$ to $25^{\circ}$ tilting angle on the basis of dynamic capturing method in order to pick convenient angle of inclination. Moreover, tried to find the optimum angle by comparing the hip pressure distribution when seated at the edge of the seat and at the center of the seat with the pressure distribution sensor.

Design of W-Band Cassegrain Antenna for Beam Steering (빔 조향을 위한 W-대역 카세그레인 안테나 설계)

  • Park, Myung-Hoon;Han, Jun-Yong;Lee, Taek-Kyung;Lee, Jae-Wook;Oh, Gyung-Hyun;Song, Sung-Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.4
    • /
    • pp.358-368
    • /
    • 2016
  • In this paper, for the mechanical beam steering of the Cassegrain antenna, the steering performances of the main reflector tilting method are characterized, and the Cassegrain antenna for the antenna rotating method is designed and its performances are measured. In the Cassegrain antenna operating at W-band, the changes of characteristics due to changes in the sizes of the main/sub-reflectors and other structural changes are analyzed to obtain the structural variables satisfying the performance goal. The manufactured antenna in W-band shows the measured gain of 42.08 dBi, 3 dB beamwidth of $1.32^{\circ}$, $1.14^{\circ}$ and the return loss($S_{11}$) of -23.58 dB at the center frequency of 94 GHz.

The Service Voltage Measurement and Analysis while TTX Runs (틸팅열차 운행 중 가선전압 계측 및 분석연구)

  • Lee, Su-Gil;Kang, Chul;Her, Jae-Sern;Kim, Jae-Chul;Lim, Jae-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.58-65
    • /
    • 2009
  • Recently, the Korea Tilting Express(TTX), "HANVIT 200", KRRI(Korea Railroad Research Institute) developed runs for test on the conventional railroad, Honam line, Center line, Chunk-buk line and Tae-baek line. In this paper, we measured the service voltage while TTX ran on the conventional railroad and analyzed the condition of voltage. For measuring voltage directly, we installed PT under the pantograph and measured the voltage of the primary winding. In addition, we record situations that other trains pass by TTX and environments while TTX ran. And then we analyzed the condition of voltage using the records and CBEMA curve. In result, over 110[%] voltage of rated voltage(25[kV]) often occurred and the voltage of some place continued over 110[%] for about 200[s]. Especially, the voltage condition of Tae-baek line is the worst. The results in this paper can help to stabilize the power device and power converter of TTX.

Effect of Different Heel Plates on Muscle Activities During the Squat (스쿼트 동작 시 발뒤꿈치 보조물 경사각에 따른 하지근과 척추기립근의 근육활동 비교)

  • Chae, Woen-Sik;Jeong, Hyeun-Kyeong;Jang, Jae-Ik
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.113-121
    • /
    • 2007
  • The purpose of this study was to determine the effect of three different plates($0^{\circ}$, $10^{\circ$}, $20^{\circ}$)under heels on the lower limb muscles and erector spinae during squat exercise. Ten high school korean traditional wrestling players(age: $18.5{\pm}0.7$, weight: $1972.2{\pm}128.5N$, height: $177.8{\pm}6.0cm$, weight of barbell: $1004.5{\pm}132.4N$) performed squat exercise using three different tilting plates under heels at a cadence of 40beats/sec with 80% one repetition maximum load. Surface electrodes were placed on the participants' left and right erector spinae, and rectus femoris, vastus medialis, vastus lateralis, tibialis anterior, biceps femoris, medial gastrocnemius, and lateral gastrocnemius in the right lower extremity. One S-VHS camcorder(Panasonic AG456, 60fields/s) was placed 10m to the side of the participant. To synchronize the video and EMG data, a synchronization unit was used for this study. Average and Peak IEMG values were determined for each participant. For each variable, a one-way analysis of variance was used to determine whether there were significant differences among three different tilting plates under heels. When a significant difference was found in plates type, post hoc analyses were performed using the Tukey procedure. A confidence level of p<.05 was used to determine statistical significance. As a result of this study, maximum nEMG values of the tibialis anterior in $0^{\circ}$ plates was significantly higher than the corresponding values for the other plates during the knee extension. This increased activation in the tibialis anterior muscle indicates an increase in displacement of center of gravity of body. It is very likely that additional muscle activation are needed to stop the forward and backward movement. The results also showed that muscular activities of quadriceps femoris and erector spinae were decreased with increasing angle of plates. This suggests that increasing angle of plate may help to sustain the balance and posture of squat exercise. It is considered that very few significant differences were found among three different plates($0^{\circ}$, $10^{\circ}$, $20^{\circ}$) since elite players with much experience in squat exercise, were chosen as a participant of this study. In order to obtain meaningful results regarding the tilting angle of heel plates in squat exercise, kinetic and 3D kinematic analysis will be needed in the future study.

Study on the Radiation Pattern of Radiated Emission above 1 GHz (1 GHz 이상에서의 복사 방출 방사 패턴에 관한 연구)

  • Chung, Yeon-Choon;Lee, Soon-Yong;Kwun, Suk-Tai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.336-344
    • /
    • 2011
  • The purpose of this study is to analyze the radiation-pattern characteristics above 1 GHz for the electromagnetic wave radiated from multi-slot such as ventilations, etc. on the enclosure of an EUT and so to make recommendations for suitable test methods. An experimental EUT was formed by putting a comb-generator at the center of a rectangular enclosure with 4 slots, and its radiation pattern was analyzed in the frequency range of 1~6 GHz. As analysis results, multi-lobe appears above 2 GHz and the number of multi-lobes is growing as the frequency increases. And real radiated-emission measurements were performed for the experimental EUT by scanning a receiving antenna in the height of 1~4 m and tilting toward maximum radiation, as well as setting the height of a receiving antenna to the central position of the EUT which is prescribed at the present standards. The measured results are +12.8 dB in the scanning and +16.4 in the scanning and tilting compared with the present standard test method. Therefore, the latter must be revised in order to consider the radiation pattern above 1 GHz.

Study on Direct Teaching Algorithm for Remote Center Motion of Surgical Assistant Robot using Force/Torque Sensor (힘/토크 센서를 이용한 수술보조로봇의 원격중심운동 직접교시 알고리즘 연구)

  • Kim, Minhyo;Jin, Sangrok
    • The Journal of Korea Robotics Society
    • /
    • v.15 no.4
    • /
    • pp.309-315
    • /
    • 2020
  • This study shows a control strategy that acquires both precision and manipulation sensitivity of remote center motion with manual traction for a surgical assistant robot. Remote center motion is an essential function of a laparoscopic surgical robot. The robot has to keep the position of the insertion port in a three-dimensional space, and general laparoscopic surgery needs 4-DoF (degree-of-freedom) motions such as pan, tilt, spin, and forward/backward. The proposed robot consists of a 6-axis collaborative robot and a 2-DoF end-effector. A 6-axis collaborative robot performs the cone-shaped trajectory with pan and tilt motion of an end-effector maintaining the position of remote center. An end-effector deals with the remaining 2-DoF movement. The most intuitive way a surgeon manipulates a robot is through direct teaching. Since the accuracy of maintaining the remote center position is important, direct teaching is implemented based on position control in this study. A force/torque sensor which is attached to between robot and end-effector estimates the surgeon's intention and generates the command of motion. The predefined remote center position and the pan and tilt angles generated from direct teaching are input as a command for position control. The command generation algorithm determines the direct teaching sensitivity. Required torque for direct teaching and accuracy of remote center motion are analyzed by experiments of panning and tilting motion.

Frustration of Rod-Disc Molecule in Reorientation under Vertical Electric Field

  • Jung, Jun-Ho;Ha, Kyung-Su;Chae, Mi-Na;Park, Seul-Ki;Song, Eun-Gyoung;Lee, Myong-Hoon;Jeong, Kwang-Un;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.610-613
    • /
    • 2009
  • New rod-disc liquid crystal (LC) molecule RD12 (12 is the number of carbon atoms between the rod and disc mesogenic liquid crystals) was synthesized via the chemical attachment of six cyanobiphenly calamitic mesogens linked to the triphenyl discotic mesogen with six alkyl chain linkage. Aligning characteristics associated with homogenous alignment is investigated at first and then field-dependent molecular reorientation under a vertical electric field is studied. Interestingly, they show abnormal slow molecular transition from initiate state (no electric field condition) to certain voltage. In this condition, we observe the molecular competition during reorientation. However, once a tilting direction of disk molecules are defined, the frustration is not observed anymore. The origin of this phenomenon is explained with a suggested model for the first time.

  • PDF

Remote Access and Data Acquisition System for High Voltage Electron Microscopy (초고전압 투과전자현미경의 원격제어 및 데이터 획득 시스템)

  • Ahn, Young-Heon;Kang, Ji-Seoun;Jung, Hyun-Joon;Kim, Hyeong-Seog;Jung, Hyung-Soo;Han, Hyuck;Jeong, Jong-Man;Gu, Jung-Eok;Lee, Sang-Dong;Lee, Jy-Soo;Cho, Kum-Won;Kim, Youn-Joong;Yeom, Heon-Young
    • Applied Microscopy
    • /
    • v.36 no.1
    • /
    • pp.7-16
    • /
    • 2006
  • A new remote access system for a 1.3 MV high voltage electron microscope has been developed. Almost all essential functions for HVEM operation, huck as stage control, specimen tilting, TV camera selection and image recording, are successfully embedded into this prototype of the remote system. Particularly, this system permits perfect and precise operation of the goniometer and also controls the high resolution digital camera via simple Web browsers. Transmission of control signals and communication with the microscope is accomplished via the global ring network for advanced applications development (GLORIAD). This fact makes it possible to realize virtual laboratory to carry out practical national and international HVEM collaboration by using the present system

The Status of Accident and Prevention Measures for Ladles (래들에 의한 재해발생 실태와 예방대책)

  • Choi, Seung Ju;Shin, Woon Chul
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.201-207
    • /
    • 2014
  • This study is aimed to improve safety of ladle in the metal products manufacturing industry. Burns may occur from spills, spatters or eruptions of hot metal from ladles during pouring or transporting. According to the statistics of occupational accidents about the ladle, many victims were exposed to or contacted with extreme temperatures. The many fatal injuries occurred as a result of unexpected discharging of molten metal due to tipping over ladles. To prevent ladles from turning over, the trunnion axis shall be located below the center of gravity of the ladle at all operating condition. For this purpose, the equation is proposed to calculate the minimum location of a trunnion axis for definite static stability when tilting.