• Title/Summary/Keyword: Tilt effects

Search Result 188, Processing Time 0.027 seconds

Influential Parameters on Offshore Jacket Structure Launching (해양 자켓구조물 진수 영향인자에 대한 고찰)

  • 조철희;김경수;김재환;이수훈
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.141-147
    • /
    • 2001
  • The launching process is one of the most critical operations for large structure in offshore installation. Since as the size increases it limits the availability of offshore crane facilities, the large jacket structures are often installed by launching. As the structure approaches to tilt beam, it reaches critical load, and there are parameters to affect on launching procedure. The major influential parameters are trim, draft of barge, center of gravity, center of buoyancy and reserved buoyancy of jacket. As increasing of trim and draft, structural loads tend to decrease. The trim is found to be more contributing than draft on structural loads. Therefore the trim should be increased so as to decrease structural loads and to avoid stalling of structure and submergence of stern. During the launching process, the distance between jacket and seabed should be investigated which differs from the amount of reserved buoyancy and launching condition of barge. In this paper the effects of parameters on launching process are numerically investigated.

  • PDF

A Study on a Mobile Sun Tracking System (이동형 태양 추적 시스템에 관한 연구)

  • Choy, Ick;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.38-43
    • /
    • 2009
  • In this paper. a prototype of a mobile Sun tracking system is proposed. The proposed system uses 2-axis tilt sensor and 3-axis magnetic sensor to measure the orientation and the posture of the system according to the horizontal system of coordinates, which are used to compensate the slope effects. Then through astronomical calculation using the time and position information obtained by GPS sensor the azimuth and altitude of the Sun from that location is calculated. The position of the Sun is converted to that of the mobile Sun tracking system coordinates and used to control A-axis and C-axis of the system.

Effects of liquid crystal alignment on new photo-dimerized PCEMA surfaces (새로운 광중합된 PCEMA 표면을 이용한 액정배향효과)

  • 황정연;서대식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.235-240
    • /
    • 2000
  • New photh-alignment materials based on PCEMA (poly(4-methacryloyloxylchalcone))for liquid crystal (LC) aligning were synthesized. and the electro(EO) characteristics of the photo-aligned TN-LCD were investigated. The excellent LC alignment and voltage-transmittance (V-T) characteristics for the photo-aligned TN-LCD on PCEMA surface containing more cinnamoly group can be achieved. However the reverse tilt disclinations for the photo-aligned TN-LCD on the PCEMA surface containing more OH group were observed. Consequently we suggest that the LC aligning capabilities can be increased by increasing of cinnamoly group on the PCEMA surfaces.

  • PDF

The Effects of the Capsule Density Uniformity on the Behavior of Cylindrical Capsules Transported through a Pipiline

  • Rhee, Kyoung-Hoon
    • Korean Journal of Hydrosciences
    • /
    • v.5
    • /
    • pp.115-124
    • /
    • 1994
  • This paper presents the results of a study conducted to improve the understanding of the characteristics of cylindrical capsule flow in a pipeline by taking into account of the effect of capsule density uniformity. The effect fo capsule density variation in the axial direction was studied both experimentally and analytically. The experiments were conducted in a 190mm diameter straight pipe 17m long. The velocity, gap and tilt of capsules were measured under various conditions. In order to interpret the data on various capsule density conditions, the stability index given in the dimensionless number was introduced. The motion of capsules in pipelines is strongly affected by the stability of the capsules characterized by the statility index. The experiments conducted proved that the stability index is a vaild criterion for explaining and correlating data on the capsule motion and the capsule denisity uniformity.

  • PDF

Study on the Functional Brassiere Development (기능적 Brassiere 개발에 관한 연구(II) - bust up 기능을 중심으로 -)

  • Choi Hei-Sun;Khang Yeo-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.3 s.39
    • /
    • pp.229-238
    • /
    • 1991
  • The object of this study is to develope an improved version of brassiere with better fit and improved performance by conducting a try-on test on 6 types of revised brassieres (constructed on above basis). The study procedures consisted of a try-on test of experimentally constructed brassieres and a sensory test on fit. The results of experimentally constructed brassiere trial are as follows. 1. The sizes showing performance effects due to different types of experimentally construct- ed brassieres were bust length, bust height, under bust curve length, vertical and horizontal bust diamenter, upper-lower bust slope angle (direct measurement, parallel standard, upper torso tilt rate), side bust slope angle and top bust slope angle. 2. Concerning the changes in lower cup interior, elastic materials and wider portions perfor-med better in bust up effect. 3. No effects due to different shoulder strap positions were observed, but combined with lower cup interior changes the side types proved more effective than the standard types.

  • PDF

A Study on the Effect of Pelvic Tilting Exercise in Hemiplegic Patients (골반운동이 뇌졸중 환자의 보행특성에 마치는 효과)

  • Lee, Jeong-Weon
    • Physical Therapy Korea
    • /
    • v.5 no.2
    • /
    • pp.23-38
    • /
    • 1998
  • The objective of this study was to identify the effects of pelvic tilting exercise on gait patterns of hemiplegic patients. The subjects of this study were 31 hemiplegic in- and out-patients of the Rehabilitation Hospital, Yonsei University Medical Center, from September 24, 1997 through November 5, 1997. Pre- and post-treatment change in gait patterns were measured using a ink foot-print. The data were analyzed by the paired t-test, one-way ANOVA, and independent t-test. The findings were as follows: The difference in gait patterns between pre- and post-treatment was statistically significant, with an increase in gait velocity to 7.98 cm/sec post-treatment; an increase in cadence to 7.29 steps/min; a narrowing of the base of support to 1.33 cm; an increase in step length of 3.92 cm on the less affected side and 3.73 cm on the more affected side; an increase in stride length of 5.82 cm on the less affected side and 5.92 cm on the more affected side(statistically not significant in foot angle). In relation to sex, age, cause of stroke, and laterality of paralysis, the difference in gait patterns between pre- and post-treatment was not statistically significant. Where there was no significant difference of the effects of pelvic exercise regarding the degree of spasticity, the presence of a decrease in proprioception, and the duration of treatment. In conclusion, hemiplegic pelvic tilting exercise was found to have transmitting positive effect in improving gait patterns.

  • PDF

Effects of Modified Abdominal Draw-in Maneuver on Trunk Muscle Stability and Functional Capacity and Pain in Patients with Chronic Low Back Pain (수정된 복부 드로우-인 기법이 만성요통 환자의 몸통 안정성과 기능, 통증에 미치는 영향 -사례연구-)

  • Kim, Chang-Beom
    • PNF and Movement
    • /
    • v.15 no.3
    • /
    • pp.217-226
    • /
    • 2017
  • Purpose: The purpose of this study was to determine the effects of a modified abdominal draw-in maneuver on trunk stability and functional capacity as well as pain in patients with chronic low back pain. Methods: The study included 3 patients with chronic low back pain who volunteered to participate. The modified abdominal draw-in maneuver included a posterior pelvic tilt, a traditional abdominal draw-in maneuver, and a vibration sensory feedback device. Voluntary abdominal contraction using the vibration sensory feedback device was performed by the subjects for more than 1 hour per day, 5 times per week, for 6 weeks along with common low back pain treatment. Electromyographic signals in the rectus abdominis (RA), external oblique (EO), internal oblique (IO), and erector spinae (ES) muscles were measured to compare muscle activation. The degree of pain was measured using the visual analogue scale (VAS), and functional capacity was measured using the Korea Oswestry Disability Index (K-ODI). All results were compared to the means before and after intervention. Results: After the intervention, the RA, EO, and IO showed increased muscle activation and the ES showed decreased muscle activation. The visual analogue scale decreased after intervention and the K-ODI decreased after intervention. Conclusion: Modified abdominal draw-in maneuvers in daily life combined with therapeutic exercises may be effective in relieving pain and dysfunctions in chronic low back pain patients.

Leg Length Discrepancy to Influence on Kinematic Changes of the Pelvis and the Hip during Gait

  • Yong, MinSik;Park, SoHyun
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.6
    • /
    • pp.368-371
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the effects of leg length discrepancy on kinematic changes of the pelvis and hip during gait. Methods: A total of ten healthy women with no history of neurological, musculoskeletal surgery or injuries, or pain in the lower limbs were recruited. They were assigned to two groups; the experimental group (LLD) consisting of five subjects leg length discrepancy of 10mm to 18mm and the control group (CON) consisting of five subjects leg length discrepancy of<10 mm. All participants were instructed to perform three walking trials for further analysis by using the Cortex 3.0 software program. Independent T-test and Mann-Whitney test were used to examine the effects of mild LLD on kinematic changes of the pelvis and hip during gait. Results: Angles of hip flexion, hip abduction, pelvic obliquity, and pelvic tilt in the experimental group were not significantly different compared to those of the control group. Conclusion: Mild leg length discrepancy induces kinematic changes in the lower limbs, including decreased hip flexion, increased hip abduction, and increased pelvic obliquity in the shorter limb, and increased hip adduction and increased pelvic obliquity in the longer limb. However, those changes were not significant.

Chemical Structural Effects of Polyimides on the Alignment and Electro-optical Properties of Liquid Crystal Cells

  • Paek, Sang-Hyon;Wonseok Dong
    • Macromolecular Research
    • /
    • v.12 no.3
    • /
    • pp.251-257
    • /
    • 2004
  • The nature of the nematic liquid crystal (LC) alignment induced by the rubbed polyimide (PI) alignment layers (ALs) and the electro-optical (EO) properties of the LC cells are expected to depend on the chemical and physical features of the PI. By employing five pyromellitic dianhydride (PMDA)-type PIs having different functionalities, we have studied the effects of the PI's structure and chemistry on the alignment characteristics and the cell's EO properties. Increasing the flexibility of the PI increases the pretilt angle and tends to improve the alignment stability. On the other hand, the rigid, fluorinated PI displays poor stability for LCs and induces a less stable/uniform LC alignment and, subsequently, a small pre tilt angle. It also transpired that fluorination of the PI deteriorated the voltage-transmittance characteristics and the voltage holding ratio; increasing the flexibility of the PI structure improves these EO properties. The finding that the qualitative trends for the PI's functionalities are similar for both the alignment and EO properties suggests that the EO properties are closely related to the alignment characteristics, which are determined by short-range interactions between LC and PI molecules.

Effects of Resistance Footrest on Spine Posture in Visual Display Terminal Workers

  • Yoo, Won-gyu
    • Physical Therapy Korea
    • /
    • v.28 no.2
    • /
    • pp.117-122
    • /
    • 2021
  • Background: Flat-back posture refers to a posture in which the pelvis is tilted backward, the lumbar spine is bent, the upper thoracic spine is increasingly bent, and the lower thoracic spine is straight. Given that most of the day is spent sitting, we need to develop exercise programs and devices that are suitable for people who spend less time exercising than sitting. Objects: This study investigated the effects of resistance footrest exercise on spine posture angles in visual display terminal (VDT) workers with flat back. Methods: We measured the upper lumbar angle (ULA) and lower lumbar angle (LLA) using a flexible ruler for the ULA and LLA. Then, after 1 week of resistance footrest exercise designed to strengthen the lumbar spine musculature, we measured these angles again. We measured each angle three times and then compared measurements from before and after exercise. Results: There were no significant differences in the ULA following the strengthening exercise, but significant differences were observed in LLA. Conclusion: The resistance footrest exercise strengthened the muscles affecting the pelvic and lumbar lordotic angles, and increases in the LLA were changed. This suggests that the role of the lower lumbar spine in the lumbar lordotic curve is greater than that of the upper lumbar spine. In addition, considering the contemporary tendency to lead fairly sedentary lives, these results indicate that exercising while seated can be effective.