• Title/Summary/Keyword: Tilt angle

Search Result 629, Processing Time 0.032 seconds

Development of MEMS Sensor-based High Resolution Tilt Monitoring System (MEMS 센서 기반 고정밀 기울기 모니터링 시스템 설계)

  • Son, Young-Dal;Eun, Chang-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.11
    • /
    • pp.1364-1370
    • /
    • 2019
  • Tilt sensors are mainly used to measure the collapse of structures such as buildings, bridges and tunnels. Recently, due to the ease of use and low price, many tilt sensors using MEMS sensors have been used, but the measurement angle range is limited, and thus, they do not have high precision for 360 degree. This is due to the inherent offset and scale errors of MEMS sensors. In this paper, we proposed an algorithm for the calculation of precision angles to reduce the mechanical error of MEMS sensors, and produced a MEMS sensor module and a transmission module to compare the angle accuracy of sensor modules before calibration and the angle measurement accuracy after calibration. Experimental results show that the proposed technique has a precision of ± 0.015 degrees for all 360-degree.

Analysis of Major Error Factors in Coherent Beam Combination: Phase, Tip Tilt, Polarization Angle, and Beam Quality

  • Jeongkyun Na;Byungho Kim;Changsu Jun;Yoonchan Jeong
    • Current Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.406-415
    • /
    • 2024
  • The major error factors that degrade the efficiency of coherent beam combining (CBC) are numerically studied in a comprehensive manner, paying particular attention to phase, tip-tilt, polarization angle, and beam quality. The power in the bucket (PIB), normalized to the zero-error PIB, is used as a figure of merit to quantify the effect of each error factor. To maintain a normalized PIB greater than or equal to 95% in a 3-channel CBC configuration, the errors in phase, tip-tilt, and polarization angle should be less than 1.06 radians, 1.25 ㎛, and 1.06 radians respectively, when each of the three parameters is calculated independently with the other two set to zero. In a worst-case scenario of the composite errors within the parameter range for the independent-95%-normalized-PIB condition, the aggregate effect would reduce the normalized PIB to 83.8%. It is noteworthy that the PIB performances of a CBC system, depending on phase and polarization-angle errors, share the same characteristic feature. A statistical approach for each error factor is also introduced, to assess a CBC system with an extended number of channels. The impact of the laser's beam-quality factor M2 on the combining efficiency is also analyzed, based on a super-Gaussian beam. When M2 increases from 1 to 1.3, the normalized PIB is reduced by 2.6%, 11.8%, 12.8%, and 13.2% for a single-channel configuration and 3-, 7-, and 19-channel CBC configurations respectively. This comprehensive numerical study is expected to pave the way for advances in the evaluation and design of multichannel CBC systems and other related applications.

A Study on Somatotype Classification of the Late Middle-Aged Women (중년 후기 여성의 체형 유형화에 관한 연구)

  • 심정희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.1
    • /
    • pp.15-26
    • /
    • 2002
  • The purpose of this study was to classier the somatotype of late middle-aged women and to analyze the characteristics of each somatotype. The subjects were 337 late middle-aged women and their age range os from 45 to 59 fears old. Data were collected through anthropometry and photometry and analyzed by factor analysis, cluster analysis and discriminant analysis. The results were as follows; 1. The result of factor analysis indicated that 9 factors were extracted through factor analysis and those factors comprised 83.56 percent of total valiance. 2. Using factor scores, cluster analysis was carried out and the subject were classified into 4 cluster. Each cluster was classified as their body front and side view contour. Type 1 is tall, slim, and lower balk is flat on the side. Type 2 is standard and lean-back type on the side. Type 3 is standard height and weight, H type in front, and belly-protruded on the side. Type 4 is short, fat, and the side is hip-protruded. 3. According to the stepwise discriminant analysis, the 9 important items in classifying the somatotype of the late middle-aged women are as follows ; lower back tilt angle, hip depth(back) -back waist depth(back), bust depth(fore) - anterior waist depth(fore), jugular fossa point(fore), upper back tilt angle, burst breadth -waist breadth, right shoulder tilt, height of shoulder - height of anterior waist, abdomen breath. The correct classification rate for these items is as exact as 84.62%.

Improved ultrasonic beacon system for indoor localization

  • Shin, Su-Young;Choi, Jong-Suk;Kim, Byoung-Hoon;Park, Mi-Gnong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1775-1780
    • /
    • 2005
  • One of the most important factors so that mobile objects can achieve their purpose is the information about their positions. In this paper, we propose an improved beacon system, to which ultrasonic sensors are attached, for the indoor localization of mobile objects. We have researched so that it can cover the wider space and estimate more accurate positions than the existent beacon systems. The existent beacon systems have the constraint that one beacon cannot cover wide area since ultrasonic sensors have limits in the angle of signal (beam-angle) on which their signal strength depends. Hence, we used the active beacon which consists of a pan-tilt mechanism and a beacon module. The active beacon system can always aim at mobile objects in order to transmit the strongest signal of the ultrasonic sensors into the objects using the pan-tilt mechanism. In addition, this system is inexpensive because it can decrease the number of beacons by about a half of the beacons of the existent system. Finally, the results show what is the difference between the active beacon system and existent beacon systems, and how accurate it is.

  • PDF

Automatic Landing System using a Trajectory of Laser Beam (레이저 빔 궤적을 이용한 자동 랜딩 시스템)

  • Hwang, Jin-Ah;Nam, Gi-Gun;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.1
    • /
    • pp.39-45
    • /
    • 2007
  • This paper proposes a method of container position measurement using automatic landing system that is estimated by a laser range finder. In the most of container position measurement methods, CCD cameras or laser scanners have been used to get the source data. However those sensors are not only weak for disturbances, for examples, the light, fog, and rain, but also the system cost is high. When the spreader arrives at the goal position, it is still swung by inertia or by wind effect. In this paper, the spreader swung data have been used to find the container position. The laser range finder is equipped in the front side of spreader. It can measure distance and relative position between spreader and container. This laser range finder can be rotated as desired by a motor. And a tilt sensor is equipped on the spreader to measure spreader sway. The relative position information between the spreader and a container using the laser range finder and tilt sensor is estimated through the geometrical analysis.

A Study on Relationship between Heart Rate Variabilities and Autonomic Balance during Head-up Tilt (Head-up Tilt상태에서 심박변동과 자율신경활동 균형의 관계에 관한 연구)

  • 정기삼;신건수
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.37-44
    • /
    • 1997
  • In this paper, the power spectral analysis of heart rate variability(HRV) was performed to evaluate effects of orthostatic stress with head-up tiIt on autonomic nervous system(ANS) for 25 healthy male subjects(age : 24 $\pm$ 5 yr.) and a new method was proposed to assess the autonomic balance. The ECG and respiration signals were recorded at tiIt angles of $0^{\circ}$, $45^{\circ}$, $90^{\circ}$and $0^{\circ}$ successively for 10 minutes per each stage under the condition of frequency controlled respiration(0.25Hz). Heat rate(HR) gradually increased ils the angle increased Similarly, according to the increment of angle, normalized low frequency component(0.05-0.15Hz) gradually increased, whereas normalized high frequency component (0.20-0.30Hz) was reduce4 From these results it is speculated that orthostatic stress head-up tiLt, results in the prevalence of sympathetic tone in autonomic balance with the increment of sympathetic tone and the decrement of parasympathetic tone, which seems to meanthat autonomic nervous system plays a major role in compensating for disturbances of cardiovascular system due to it.

  • PDF

Analysis of a Semicircle Antenna by Tilt Angles for Wideband Applications (광대역 통신용 반원형 안테나의 경사각에 의한 성능분석)

  • Jung, Chang-Won;Yeom, In-Su;Park, Se-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1509-1513
    • /
    • 2009
  • A semicircle antenna is presented for wideband communication system. The proposed antenna radiates linear polarized wave omnidirectionally in wide frequency band from 1.5 GHz to more than 5 GHz (110%). The frequency bands of the proposed antenna are investigated from the variable current path lengths by tilting angles. The overall radiation gain of the proposed antenna is 2-3 dBi.

MORPHOLOGICAL CHARACTERISTICS OF NONLINEAR OPTICAL MOLECULES AT THE AIR/WATER INTERFACE

  • Lim, Sung-Taek;Park, Mi-Kyung;Shin, Dong-Myung;Kwon, Ohoak
    • Journal of Photoscience
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 1998
  • The texture change of non-linear optical molecules at the air/water interface was investigated as a function of surface pressure with Brewster angle microscopy. The texture change resulted from the aggregation of dye molecules is important to understand the film uniformity and grain formation process. The 4-Octadecylhydroxy-4'-nitrostilbene (OHNS) generated the small spots of size around 1$\mu$m. The spots exhibit high contrast with other film area and do not show angle dependent reflectivity change. It is interesting to observe that the size of the domain stays the same as the film pressure increases. At high surface pressure, the contrast ratio of domains becomes high, which means dense packing of OHNS. And, the size of domain grows. In the middle of domain, highly contrasted domains are formed. The first and the second order transitions of OHNS observed from surface pressure-area isotherm result from the two types of grains. The N,N-Dihexadecylcyanoaniline (DHCA) formed highly contrasted gains over entire region, and the grains are the double layers. The difference in Langmuir film of OHNS and DHCA at the air/water interface is consistent with the small tilt angle from the surface normal for OHNS and the large tilt angle for DHCA in the Langmuir-Blodgett films.

  • PDF

Effects of Neck Stabilizing Exercise on Muscle Characteristics, Muscle Activity and Posture in Patients with Cervicogenic Headache (목 안정화 운동이 경추성두통 환자의 근육특성과 근활성도 및 자세에 미치는 영향)

  • Park, Seungkyu;Yoon, Jonghyuk
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.4
    • /
    • pp.301-309
    • /
    • 2019
  • Purpose : The purpose of this study was to provide an effective method of exercise therapy for patients with cervicogenic headache. Methods : The subjects were divided into the following two groups according to the intervention received: cervical stretch exercise (n=15, control group) cervix-stabilizing exercise (n=15, experimental group) tone (Hz) and stiffness (N/m) of the suboccipital and upper trapezius muscles were measured. T1 slope angle and neck tilt angle were measured. After the exercise program intervention, a greater amount of change in muscle tone and stiffness of suboccipital and upper trapezius muscles was found in the experimental group, as compared to the control group. Greater amount of change in posture was found in the experimental group, as compared to the control group (p<0.05). Results : After the exercise program intervention, a greater amount of change in muscle tone and stiffness of suboccipital and upper trapezius muscles was found in the experimental group, as compared to the control group. Greater amount of change in posture was found in the experimental group, as compared to the control group (p<0.05). Conclusion : The neck-stabilizing exercise were shown to be effective in decreasing the tone of the cervical muscles by stabilizing the cervical bone and improving muscle activity, and in improving the posture by decreasing muscle tone and stiffness.

Ellipsometric Expressions of Multilayered Substrate Coated with a Uniaxially Anisotropic Alignment Layer (단축이방성 배향막이 코팅되어 있는 다층박막시료의 타원식)

  • Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.271-278
    • /
    • 2013
  • The effective reflection coefficients of an obliquely incident wave on a multi-layered substrate coated with a uniaxially anisotropic alignment layer are derived. The effective reflection coefficients as well as explicit ellipsometric expressions are provided as a function of film constants of multiple layers together with magnitude of anisotropy, direction of optic axis, and thickness of the alignment layer. It is expected that by adapting these expressions to the conventional modelling technique, the ordinary refractive index, the extra-ordinary refractive index, the azimuth angle and the tilt angle of the optic axis, and the thickness of the aligned surface can be determined simultaneously together with the thickness and volume fraction of each layer beneath the alignment layer.