• Title/Summary/Keyword: Tilt System

Search Result 686, Processing Time 0.025 seconds

Oscillatory Josephson-Vortex Resistance in Stacks of $Bi_{2}Sr_{2}CaCu_{2}O_{8+x}$ Intrinsic Josephson Junctions

  • Choi Jae-Hyun;Bae Myung-Ho;Lee Hu-Jong;Kim Sang-Jae
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • We report the oscillation of the Josephson vortex-flow resistance in the rectangular stacks of $Bi_{2}Sr_{2}CaCu_{2}O_{8+x}$(Bi-2212) intrinsic Josephson junctions (IJJs). Apiece of Bi-2212 single crystal containing a few tens of IJJs was sandwiched between two gold electrodes and fabricated into a rectangular shape with the typical lateral size of about $1.5{\times}10\;{\mu}m^2$, using e-beam lithography and focused ion-beam etching techniques. In a tesla-range magnetic field applied in parallel with the junction planes, the oscillation of the Josephson vortex flow resistance was observed at temperatures near 60 K. The oscillation results from the interplay between the triangular Josephson vortex lattice and the potential barrier at the boundary of a single crystal. The oscillatory magnetoresistance for different bias currents, external magnetic fields, and the tilt-angles provides useful information on the dynamics of the coupled Josephson-vortex lattice system.

  • PDF

The Wetting Properties of UBM-coated Si-wafer to the Lead-free Solders in Si-wafer/Bumps/Glass Flip-Chip Bonding System

  • Hong, Soon-Min;Park, Jae-Yong;Park, Chang-Bae;Jung, Jae-Pil;Kang, Choon-Sik
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2000.04a
    • /
    • pp.74-79
    • /
    • 2000
  • In an attempt to estimate the wetting properties of wettable metal layers by wetting balance method, an analysis of wetting curves of the coating layer was performed. Based on the analysis, wetting properties of UBM-coated Si-plate were estimated by the new wettability indices. The wetting curves of the one and both sides-coated UBM layers have the similar shape and show the similar tendency to the temperature. So the wetting property estimation of one side coating is possible with wetting balance method. For UBM of Si-chip, Cr/Cu/Au UBM is better than Ti/Ni/Au in the point of wetting time. At general reflow temperature, the wettability of high melting point solders(Sn-Sb, Sn-Ag) is better than that of few melting point ones(Sn-Bi, Sn-In).The contact angle of the one side coated plate to the solder can be calculated from the farce balance equation by measuring the static state force and the tilt angle.

  • PDF

CONTINUOUS PERSON TRACKING ACROSS MULTIPLE ACTIVE CAMERAS USING SHAPE AND COLOR CUES

  • Bumrungkiat, N.;Aramvith, S.;Chalidabhongse, T.H.
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.136-141
    • /
    • 2009
  • This paper proposed a framework for handover method in continuously tracking a person of interest across cooperative pan-tilt-zoom (PTZ) cameras. The algorithm here is based on a robust non-parametric technique for climbing density gradients to find the peak of probability distributions called the mean shift algorithm. Most tracking algorithms use only one cue (such as color). The color features are not always discriminative enough for target localization because illumination or viewpoints tend to change. Moreover the background may be of a color similar to that of the target. In our proposed system, the continuous person tracking across cooperative PTZ cameras by mean shift tracking that using color and shape histogram to be feature distributions. Color and shape distributions of interested person are used to register the target person across cameras. For the first camera, we select interested person for tracking using skin color, cloth color and boundary of body. To handover tracking process between two cameras, the second camera receives color and shape cues of a target person from the first camera and using linear color calibration to help with handover process. Our experimental results demonstrate color and shape feature in mean shift algorithm is capable for continuously and accurately track the target person across cameras.

  • PDF

Study on the Heat Collecting Performance of Flat-Plate Solar Collector by the angle (평판형 태양열 집열기의 각도에 따른 집열성능 연구)

  • Ji, M.K.;Kong, T.W.;Bae, C.W.;Jeong, H.M.;Chung, H.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.316-321
    • /
    • 2000
  • In this study, heat collecting performance was study of flat plate solar collector by the angle. A method of study on were made turn out artificial sun by the angle of 0, 15, 30 degrees. The heat performances were measured the tube array surface temperature by thermo-couple. The winter season natural condition for 4 times on the angles of various general and emboss glass at optimum distance(0.68m) calculated of between sun and solar collector. To sum up temperature rise is appear more or less that emboss glass is all the better for general glass. The temperature variable at below of 30 degree was appear very less. The maximum performance of this system at that it is tilt angle of 30 with general glass is appear Q:11.54(kcal/min) and ${\Delta}T=18.9^{\circ}C$.

  • PDF

A Study on Assessments of Baroreflex Sensitivity through the Closed-loop Feedback Model of Cardiovascular System (심혈관계의 폐루프 귀환 모델을 통한 압수용체반사감도의 평가에 관한 연구)

  • Choi, S.J.;Shin, K.S.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.447-450
    • /
    • 1997
  • In this paper, the method is proposed, which enables us to assess baroreflex sensitivity noninvasively through the closed-loop feedback model between RR fluctuation and arterial blood pressure fluctuation, which are obtained in blood low signals. The proposed indexes of baroreflex sensitivity, $BRS_{LF}$ and $BRS_{HF}$, are calculated by the modulus(or gain) of the transfer unction between two fluctuations above in LF band and HF band, where the coherence is more than 0.5. To evaluate the performance of the proposed method, it is applied to blood low signals obtained from subjects at tilt angles of $0^{\circ},\;45^{\circ},\;90^{\circ}$ and $0^{\circ}$ successively. In result, it is concluded that the proposed method enables us to assess baroreflex sensitivity noninvasively.

  • PDF

Analysis and Design of 3-DOF Parallel Mechanism Based on Kinematic Couplings (기구학적 커플링으로 구성된 3자유도 병렬 메커니즘 해석 및 설계)

  • Wang, Wei-Jun;Han, Chang-Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.479-486
    • /
    • 2012
  • This paper presents a high-speed automatic micro-alignment system that is a part of an inspection machine for small-sized molded lenses of mobile phones, palm-top computers, and so on. This work was motivated by the shortcomings of existing highest-grade commercial machine. A simple tip/tilt/Z parallel mechanism is designed based on kinematic couplings, which is a 3-degree-of-freedom (3-DOF) moderate-cost alignment stage. It is used to automatically adjust the posture of each lens on the tray, which is impossible by the conventional instrument. Amplified piezoelectric actuators are used to ensure the accuracy and dynamic response. Forward kinematic analysis and simulation show that the parasitic motion is small enough compared to the actuator stroke. From the workspace analysis of the moving platform, it is clear that the output motion range satisfies the design requirements.

Aerodynamic Design of SUAV Flaperon (스마트무인기 플래퍼론 공력설계)

  • Choi, Seong-Wook;Kim, Jai-Moo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.8
    • /
    • pp.26-33
    • /
    • 2005
  • Smart UAV, which adopting tiltrotor aircraft concept, requires vertical take-off and landing, long endurance and high speed capability. These contradictable flight performances are hard to meet unless the operation of flap system which should reveal optimal performance for each flight mode. In order to design SUAV flaperon satisfying the three performance requirements, various configurations are generated and their aerodynamic performances are analyzed using numerical flow computations around flap systems. Considering aerodynamic performance and structural simplicity, a final flap configuration is selected and the performance is validated through the wind tunnel testing for 40% scale model.

WASHINGTON PHOTOMETRY OF THE GLOBULAR CLUSTERS IN THE VIRGO GIANT ELLIPTICAL GALAXY M86

  • Park, Hong-Soo
    • Journal of The Korean Astronomical Society
    • /
    • v.45 no.3
    • /
    • pp.71-84
    • /
    • 2012
  • We present a photometric study of the globular clusters (GCs) in the Virgo giant elliptical galaxy M86 based on Washington $CT_1$ images. The colors of the GCs in M86 show a bimodal distribution with a blue peak at ($C-T_1$) = 1.30 and a red peak at ($C-T_1$) = 1.72. The spatial distribution of the red GCs is elongated similar to that of the stellar halo, while that of the blue GCs is roughly circular. The radial number density profile of the blue GCs is more extended than that of the red GCs. The radial number density profile of the red GCs is consistent with the surface brightness profile of the M86 stellar halo. The GC system has a negative radial color gradient, which is mainly due to the number ratio of the blue GCs to the red GCs increasing as galactocentric radius increases. The bright blue GCs in the outer region of M86 show a blue tilt: the brighter they are, the redder their mean colors get. These results are discussed in comparison with other Virgo giant elliptical galaxies.

The Effect of Thoracic Posture on The Shoulder Range of Motion and on Three-Dimensional Scapular Kinematics (흉추 자세가 견관절 가동범위와 3차원적 견갑골 운동학에 미치는 영향)

  • Park, Seung-Kyu;Han, Song-E
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.2
    • /
    • pp.197-204
    • /
    • 2010
  • Scapular position and motion are essential for normal upper limb mobility; Further, the posture of patients with thoracic kyphosis is related to shoulder girdle function and disorder. The purpose of this study was to examine the effects of thoracic posture on the shoulder range of motion and on three-dimensional scapular kinematics. Thirty healthy subjects performed right-arm abduction along the frontal plane while standing in both erect and in slouched trunk posture. The scapular position and rotation, and shoulder and thoracic angles were recorded using a motion analysis system. The scapular upward rotation and internal rotation were significantly altered according to postural tatiges; however, scapular tilt was not affected. Shoulder angle was significantly decreased in the slouched posture as c rpared to tatt in the erect posture. Thus, a slouched posture(thoracic kyphosis) significantly affects the shoulder range of motion and scapular kinematics during shoulder abduction in the frontal plane.

Differential diagnosis of vertigo (어지럼증의 감별진단)

  • Kang, Ji-Hoon;Shin, Ji-Yong;Kim, Min-Ju;Ma, Hyeo-Il
    • Journal of Medicine and Life Science
    • /
    • v.16 no.3
    • /
    • pp.64-75
    • /
    • 2019
  • Vertigo and dizziness are common symptoms with various etiologies and pathogeneses. Vertigo is an illusion of motion due to disease of the vestibular system, usually a sense of rotation. Dizziness, a term that represents a wide range of non-vertigo symptoms, is commonly associated with non-vestibular disorders including old age, cardiac syncope, orthostatic hypotension, metabolic disease, anxiety, and drugs. Vertigo should be determined whether the cause is central or peripheral. Peripheral vertigo is usually benign but central vertigo is serious and often require urgent treatment. The careful history and detailed physical examinations(pattern of nystagmus, ocular tilt reaction, head impulse test and positional tests such as Dix-Hallpike maneuver) provide important clues to the diagnosis of vertigo. Most of patients have benign peripheral vestibular disorders - vestibular neuritis, benign paroxysmal positional vertigo (BPPV), and Meniere's disease. BPPV is a leading cause of peripheral vertigo and can easily be cured with a canalith repositioning maneuver. In this review, a focus is on the differential diagnosis of common vestibular disorders with peripheral and central causes.