• Title/Summary/Keyword: Tile Index

Search Result 59, Processing Time 0.025 seconds

Calculation of Topographic Index with Geographic Information System

  • Kim, Sang-Hyun;Ham, Kun-Yeun
    • Korean Journal of Hydrosciences
    • /
    • v.8
    • /
    • pp.85-95
    • /
    • 1997
  • The multiple flow direction algorithm to calculate the spatial variation of the saturation tendency, I. e. topographic index, is integrated into the Geographic Information System, GRASS. A procedure is suggested to consider the effect of a tile system on calculating the topographic index. A small agricultural subwatershed ($3.4\;\textrm{km}^2$) is used for this study. The impact of a tile system on the groundwater table can be effectively considered by the Laplace's equation to the DEM. The analysis shows that a tile system has a high degree of saturation to compared to the case without tile drainage, and the predicted riparian area is well fitted to the actual watershed condition. A procedure is suggested to consider a tile system's effect on calculating the topographic index.

  • PDF

Calculation of Watershed Topographic Index with Geographic Information System (지리정보시스템을 이용한 유역에서의 지형지수 산정)

  • 김상현;한건연
    • Water for future
    • /
    • v.29 no.4
    • /
    • pp.199-208
    • /
    • 1996
  • The multiple flow direction algorithm to calculate the spatial variation of the saturation tendency, i.e. topographic index, is integrated into the Geogrphic Information System, GRASS. A procedure is suggested to consider the effect of a tile system on calculating the topographic index. A small agricultural subwatershed (3.4$\textrm{km}^2$) is used for this study. The impact of a tile system on the groundwater table can be effectively considered by the Laplace's equation to the DEM. The analysis shows that a tile system has a high degree of saturation compared to the case without tile drainage, and the predicted riparian area is well fitted to the actual watershed condition. A procedure is suggested to consider the effect of tile system on calculating the topographic index.

  • PDF

Effect of Hydrophobic Surface Coating on Flowability of Ceramic Tile Granule Powders (표면 소수화 처리를 통한 도자타일 과립 분말의 유동 특성)

  • Kim, Jin-Ho;Kim, Ung-Soo;Han, Kyu-Sung;Hwang, Kwang-Take
    • Korean Journal of Materials Research
    • /
    • v.29 no.7
    • /
    • pp.425-431
    • /
    • 2019
  • Generally, ceramic tiles for building construction are manufactured by dry forming process using granular powders prepared by spray drying process after mixing and grinding of mineral raw materials. In recent years, as the demand for large ceramic tiles with natural texture has increased, the development of granule powders with high packing ratio and excellent flowability has become more important. In this study, ceramic tile granule powders are coated with hydrophobically treated silica nanoparticles. The effects of hydrophobic silica coating on the flowability of granule powders and the strength of the green body are investigated in detail. Silica nanoparticles are hydrophobically treated with GPTMS(3-glycidoxypropyl trimethoxy silane), which is an epoxy-based silane coupling agent. As the coating concentration increases, the angle of repose and the compressibility decrease. The tap density and flowability index increase after silica coating treatment. These results indicate that hydrophobic treatment can improve the flowability of the granular powder, and prevent cracking of green body at high pressure molding.

A study on Reliability Analysis for Plane Frame Structure (평면뼈대구조의 신뢰성해석에 관한연구)

  • 이중빈;신형우
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1989.10a
    • /
    • pp.34-39
    • /
    • 1989
  • Recent trends in design standards development have encouraged the use of probabilistic limit sate design concepts. Reliability analysis adopted in those advanced countries have the potentials that they afford for symplifying the design Process arid placing it on a consistent reliability based for various construction materials. This study is proposed in the reliability analysis of plane frame structures using second-order moment method(Level-II they). Lind-Hasofer's minimum distance method is use in the derivation of an mathematical algorithm as well as an determination of Correlation cofficients, reliability index and total reliability index depending on the multiple failure modes. In addition. This study is employed as a practical tool for the approximate reliability analysis. Results of the numerincal analysis showed that the difference between the reliability index of the failure probability of the multiple failure modes and the total reliability index of the failure probability with the simultaneous failure modes deviated nearly 3∼10% depending on tile performance functions.

  • PDF

A Study on the Development of an Instrument for Evaluating the Quality of Nursing Care (간호의 질 평가도구 개발에 관한 일 연구)

  • 유지수
    • Journal of Korean Academy of Nursing
    • /
    • v.7 no.2
    • /
    • pp.11-21
    • /
    • 1977
  • Many in nursing look back on Nursing Research history and proudly point to the fact that emphasis in nursing research has changed from studying the nurse to studying nursing practice. In recent years, much emphasis has been placed on seeking a method of evaluating the quality of nursing care. In spite of these attempts, however, an instrument for evaluating the quality of nursing care that is actually applicable in the clinical area has not been found. The Purposes of this study are as follows: 1) To develop the instrument to be used in evaluating the quality of nursing care provided in the Neuro - Surgery Constant Care Unit of Severance Hospital 2) To evaluate the quality of nursing care in the clinical area. 3) To provide the necessary information for improvement of quality of nursing care. The instrument for evaluating the quality of nursing care, developed by the investigator, was composed of 7 nursing goals and divided into 65 standards of nursing performance. The 7 nursing goal are as follows : 1) Maintenance of airway 2) Maintenance of fluid at electrolyte balance 3) Maintenance of elimination 4) Personal hygiene 5) Optimum activity 6) Prevention of accidents 7) Emotional care The study population defined was composed of all the case (51) who were admitted in the Neuro- Surgery Constant Care Unit of Severance Hospital from May 7-13, 1976. The observation method was used and the data was subjected to the %, X²-test, T-test, F-test and Correlation. The results of tile study were as follows : 1. Levels of nursing performance regarding nursing goals. Seven different nursing care indices were constructed in terms of nursing goals. The index scores were grouped arbitrarily into ,j categories such as "excellent", "good", "moderate", "incomplete", and "poor"based upon the investigator′s personal judgement. a. The nursing index of maintaining airway showed that 78% of the patients fell within the "excellent" and 22% of the patients, fell within the "good" category. b. The nursing index of maintaining fluid & electrolyte balance showed that 95% of the patients fell within the "excellent" and 5 % of the patients fell within the "good" category. c. The nursing index of maintaining elimination showed that 100% of the patients fell within the "excellent" category. d. The nursing index of personal hygiene revealed that 49% of the patients fell within the "excellent" and 51% of the patients fell within the "good" category. e. The nursing index of optimum activity showed that 63% of the patients fell within the "excellent" and 32% of the patients fell within tile "good" and 5% of patients fell within the "moderate" category. f. The nursing index of prevention of accidents showed that 100% of the patients foil within the "excellent" category. g. The nursing index of emotional cart revealed that 27% of the patients fell within the "excellent", 24 % of the patients fell within tile "good", 29 % of the patients fell within the "incomplete" category. From these findings it is disclosed that the quality of nursing care provided in the Neuro- Surgery Constant Care Unit of Severance Hospital was excellent. h. There were statistically significant differences between the nursing index of physical care and emotional care. (t=8.73, D. F. =100. p<0.01) It is revealed that more physical care then emotional care was carried out by nurses. 2. Levels of nursing performance regarding general characteristics of the patients. No significant differences were observed statistically with the nursing indices of nursing goals according to the sex (t=0.084, D. F. =12, p>0.05). Age (F=0.1251, D. F. : 3.18. p 〉0.05), absence or presence of operating experiences (t=0.6032, D. F. =12, p〉0.05, levels of consciousness (F=0.31, D. F. :3. 18, p >0.05) 3. Relationship between the levels of consciousness and the nursing index of each nursing goal. There was negative correlation between the levels of consciousness and the nursing index of maintaining airway (r=-0. 5449, p<0.01) and personal hygiene (r= -0.4075, p<0.01) There was positive correlation between the levels of consciousness and the nursing index of optimum activity (r=0.3936, p <0.01) and emotional care (r=0.7819, p〈0.01). There was slight correlation between the levels of consciousness and the nursing index of maintaining fluid & electrolyte balance (r=-0.3418, 0.010.05) and preventing accidents (r=0.1441, p>0.05.

  • PDF

The structural analysis of bogie for high speed freight car (고속화차용 용접대차의 구조강도해석)

  • 황원주;함영삼;권성태;허현무;전응식
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.217-221
    • /
    • 2001
  • Barber bogie and Y25 bogie is the main bogie of freight car which is used in the Korean railway. In case of Barber bogie and a mixed formation tile maximum speed limit of empty car is 70 km/h and that of loaded car is 90 km/t and also it runs a speed of 110 km/h in time of an exclusive formation of Y25 bogie. The car named as high speed freight car at present is Y25 bogie which modeled on the Y25 bogie or Europe developed in 1993, Y25 bogie has no problem about the running capacity up to the speed of 110 km/h, but it works as limiting factors to tile increasing cost of maintenance and repair expenses which caused by repair of bogie and the cost of materials. This study is going to describe the contents examined by analysis and tests, aimed at being used as an index of plan in the future through the strength test of high speed freight car which is used now.

  • PDF

The Relation between the Process Capability Index and the Quality Assurance Level Considering Various Conditions (다양한 상황을 고려한 공정능력지수와 품질보증수준의 관계)

  • 조문수;임태진
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.2
    • /
    • pp.130-151
    • /
    • 2002
  • This paper investigates the relation between the Process capability index(PCI) and the quality assurance level under various conditions. The effect of the off-targetness of the process mean, deviation from the nomality, the estimation error, and tile measurement error on the quality assurance level is evaluated. Various distributions such as the Student-t, the chi-square, the gamma, the Weibull, and the log-normal distributions are considered to evaluate the deviation from the nomality. The quality levels under abnormal conditions turn out to be severely different from that under the standard condition. We provide tables and graphs of the quality assurance level on various abnormal conditions. In order for the industry users to use the PCI properly, they should refer to the tables and graphs, especially when they are not certain about the standard assumptions on which the PCI depends.

Robust Reference Point and Feature Extraction Method for Fingerprint Verification using Gradient Probabilistic Model (지문 인식을 위한 Gradient의 확률 모델을 이용하는 강인한 기준점 검출 및 특징 추출 방법)

  • 박준범;고한석
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.40 no.6
    • /
    • pp.95-105
    • /
    • 2003
  • A novel reference point detection method is proposed by exploiting tile gradient probabilistic model that captures the curvature information of fingerprint. The detection of reference point is accomplished through searching and locating the points of occurrence of the most evenly distributed gradient in a probabilistic sense. The uniformly distributed gradient texture represents either the core point itself or those of similar points that can be used to establish the rigid reference from which to map the features for recognition. Key benefits are reductions in preprocessing and consistency of locating the same points as the reference points even when processing arch type fingerprints. Moreover, the new feature extraction method is proposed by improving the existing feature extraction using filterbank method. Experimental results indicate the superiority of tile proposed scheme in terms of computational time in feature extraction and verification rate in various noisy environments. In particular, the proposed gradient probabilistic model achieved 49% improvement under ambient noise, 39.2% under brightness noise and 15.7% under a salt and pepper noise environment, respectively, in FAR for the arch type fingerprints. Moreover, a reduction of 0.07sec in reference point detection time of the GPM is shown possible compared to using the leading the poincare index method and a reduction of 0.06sec in code extraction time of the new filterbank mettled is shown possible compared to using the leading the existing filterbank method.

Speech Intelligibility Analysis on the Vibration Sound of the Glass Window of a Conference Room (회의실 유리창 진동음의 음성 명료도 분석)

  • Kim, Hee-Dong;Kim, Yoon-Ho;Kim, Seock-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.4 s.121
    • /
    • pp.363-369
    • /
    • 2007
  • The purpose of the study is to obtain acoustical information to prevent eavesdropping of the glass window. Speech intelligibility was investigated on the vibration sound detected from the glass window of a conference room. Objective test using speech transmission index(STI) was performed to estimate quantitatively the speech intelligibility. STI was determined based on tile modulation transfer function(MTF) of the room-glass window system. Using Maximum Length Sequency(MLS) signal as a sound source, impulse responses of the glass window and MTF were determined by signals from accelerometers and laser doppler vibrometer. Finally, speech intelligibility of the interior sound and window vibration were compared under different sound pressure levels and amplifier gains to confirm the effect of measurement condition on the speech intelligibility.

A Study on the Toxicity Analysis of Combustion Gases of Architectural Surface Materials and Architectural Adhesives (건축용 외장재와 접착제 연소가스의 독성분석에 관한 연구)

  • Kim, Won-Jong;Park, Young-Ju;Lee, Hae-Pyeong;Lim, Suk-Hwan;Kim, Jung-In
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.48-52
    • /
    • 2013
  • This study was carried out, using toxicity test apparatus, to analyze toxic gases of heat insulation material and adhesives of composite panels used for the architectural surface material when a fire occurs. The findings of this study show that CO, $CO_2$, HCOH, $CH_2CHCN$ and $NO_x$ were detected from styrofoam, reinforced styrofoam, polyurethane foam and glass fiber, but in the case of the polyurethane foam, HCl and HCN were detected as well. All the architectural adhesives released CO, $CO_2$ and $NO_x$, but HCHO was only detected from the adhesives for styrofoam, wood, tile, windows and doors; $CH_2CHCN$ was only from those for wood and stone; $C_6H_5OH$ was only from those for wood. The toxicity index was also measured for architectural surface material and adhesives. Polyurethane foam showed the highest index, 11.7, and glass fiber was followed as 6.8. Reinforced styrofoam showed 5.7 and styrofoam revealed the least 4.9. In the case of architectural adhesives, the highest ranking was those for stone 7.4, windows and doors 6.1, wood 5.3, tile 3.8, and styrofoam 3.7 were followed, respectively.