• Title/Summary/Keyword: Tightness

Search Result 438, Processing Time 0.022 seconds

Effects of a Complex Manual Therapy Program for Sacroiliac Joint Dysfunction on Women's Menstrual Pain, Joint Pain, and Hip Range of Motion: A Single Case Study (엉치엉덩관절 기능부전에 대한 복합 도수치료 프로그램이 여성의 생리통, 관절 통증, 엉덩관절 가동 범위에 미치는 영향: 단일 사례 보고)

  • Woon-ho Choi;Seung-byoung Lee;Suk-chan Hahm
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.3
    • /
    • pp.85-99
    • /
    • 2023
  • Background: This study aimed to investigate the effects of a complex manual therapy program on hip and knee pain occurring together with menstrual pain and iliotibial band tightness in a woman with sacroiliac joint dysfunction. Methods: This study was carried out over a period of 3 months by dividing the treatment process into three sequential stages. Intensities of menstrual pain, hip pain, and knee pain, and hip range of motion (ROM) in the participant were assessed at baseline and at the end of each stage, and a modified intervention was applied according to results of assessments after each stage. Results: There was a decrease in the intensity of menstrual pain after the first and third stages of treatment, and there were reductions in the intensities of hip and knee pain after the third stage. Hip ROM was rather decreased after the second stage, but it was increased after the third stage. Conclusion: The findings of this study indicate that treatment of the instability and positional fault of sacroiliac joint can relieve hip and knee pain, improve hip ROM, and alleviate primary dysmenorrhea in patients with sacroiliac joint dysfunction.

  • PDF

Evaluation of the Load Carrying Capacity on a Rahmen Bridge with Ultra-high Strength Centrifugally Formed Square Beams as the Superstructure (초고강도 원심성형 각형보를 상부구조로 하는 라멘교의 내하성능 평가 )

  • Doo-Sung Lee;Sung-Jin Kim;Jeong-Hoi Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.61-69
    • /
    • 2024
  • An ultra-high strength prestressed prismatic beam of 100 MPa in compressive strength was developed by increasing the water-tightness of concrete by utilizing centrifugal molding processes without adding expensive admixtures. The centrifugal prismatic PSC beam developed as the superstructure of the avalanche tunnel was constructed on a rahmen bridge in a small local river. In this study, the centrifugal prismatic beam was compared and analyzed based on the results of measurements made through static load tests and the results of numerical analysis of the target structure. The common load-carrying capacity and safety of the rahmen bridge were evaluated. The static·dynamic load tests and finite element analysis results of this bridge were similar, and it was confirmed that the behavior of the centrifugal prismatic beam was well simulated. All centrifugally formed square beams that make up the composite rahmen bridge were evaluated to secure sufficient load carrying capacity under the design live load, and structural reliability was proven by ensuring safety.

Effects of Aged Black Garlic Extracts on the Tight Junction Permeability and Cell Invasion in Human Gastric Cancer Cells (흑마늘 추출물이 인체위암세포의 tight junction 투과성 조절과 세포 침윤성 억제에 미치는 영향)

  • Shin, Dong-Yeok;Yoon, Moo-Kyoung;Choi, Young-Whan;Gweon, Oh-Cheon;Kim, Jung-In;Choi, Tae-Hyun;Choi, Yung-Hyun
    • Journal of Life Science
    • /
    • v.20 no.4
    • /
    • pp.528-534
    • /
    • 2010
  • Garlic (Allium sativum) has been well-known as a folk remedy for a variety of ailments since ancient times, and it is well documented that enhanced garlic consumption leads to a decrease in incidences of cancer. Tight junctions (TJs) are critical structures for the maintenance of cellular polarity, acting as paracellular permeability barriers and playing an essential role in regulating the diffusion of fluid, electrolytes and macromolecules through the paracellular pathway. Matrix metalloproteinases (MMPs) have been implicated as possible mediators of invasiveness and metastasis in some cancers. In this study, we investigated the potential effects of water extract of aged black garlic (ABG) on the correlation between tightening of TJs and anti-invasive activity in human gastric carcinoma AGS cells. The inhibitory effects of ABG on cell motility and invasiveness were found to be associated with increased tightness of TJs, which was demonstrated by an increase in transepithelial electrical resistance. Additionally, the activities of MMP-2 and -9 in AGS cells were inhibited by treatment with ABG, and this was also correlated with a decrease in the expression of their mRNA and proteins. Furthermore, RT-PCR and immunoblotting results indicated that ABG repressed the levels of the claudin proteins, major components of TJs that play a key role in the control and selectivity of paracellular transport. In conclusion, these results suggest that ABG treatment may inhibit tumor metastasis and invasion, and therefore may act as a dietary source to decrease the risk of developing cancer.

All-inside Arthroscopic Capsular Imbrication and Lateral Release in Patellofemoral Instability (Operative technique) (슬개대퇴관절 불안정성에서의 관절경적 All-inside 관절막 중첩술 및 외측 지대 유리술 (수술 술기))

  • Kim, Jae-Hwa;Cho, Duck-Yun;Yoon, Hyung-Ku;Kim, Jung-Ryul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.118-122
    • /
    • 2006
  • Purpose: We introduce a technique of all inside arthroscopic capsular imbrication and lateral release used to treat patellofemoral instability. Methods: With the arthroscope in the anteromedial portal for best viewing, the arthroscopic scissor is placed through superolateral portal for proximal to distal release. The release performed 5mm to 1cm from the edge of the patella. After completion of the procedure, with the arthroscope in anterolateral portal, we inserted 5mm cannula in superolateral portal and made working portal from superomedial portal. Medial reefing was performed with all inside technique by using curved needle of the spectrum suturing system and No. 1 monofilament PDS suture is passed through the superomedial portal percutaneously and retrieved through a superolateral portal. Conclusion: Several methods for arthroscopic patella realignment have been proposed, but they have consisted primarily of arthroscopically assisted techniques using a medial incision. We believe that our procedure is preferable to arthroscopically assisted methods commonly used, in that an incision is avoided and the vastus medialis obliqqus is not violated. Our technique is minimally invasive and is easy to control the tightness of the medial patellofemoral ligament (MPFL) under direct vision.

  • PDF

An Evaluation of Flexural Behavior of Fume Pipe Repaired by Hybrid Concrete Repair Materials (하이브리드 콘크리트 보수재료로 보수된 흄관의 휨 거동 평가)

  • Yoo, Sung Won;Choi, Young Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.92-98
    • /
    • 2019
  • In this study, we developed a repair material incorporating PVA powder resin and nylon fiber into cemented carbide used in the existing field to improve adhesion performance and water tightness with existing concrete. Flexural behavior evaluation was performed. The main experimental variables were PVA powder resin, nylon fiber mixing rate and damage type, and performance tests were conducted to evaluate compressive strength and flexural behavior after repairing materials. It was found that all formulations fully satisfied the required performance of the repair material. The flexural strength test results of the repaired tube specimens showed that the performance of the repaired materials was maximized when the nylon fiber was added and the PVA powder was added in an appropriate amount. The flexural behavior of all the specimens showed the flexural behavior of the structural members with a low rebar ratio, suggesting that the amount of iron wire in the domestic fume pipe was somewhat insufficient. That is, it was confirmed that the amount of reinforcement of the steel wire was somewhat small, so that the concrete was cracked before the behavior of the concrete and the steel wire reached the extreme state, and the concrete was immediately destroyed beyond the tensile strength of the concrete.

A Study on the Results of Questionnaire Survey and Health Examination for Respiratory Disease among Residents in Briquette Fuel Complex in Ansim, Daegu (안심연료단지 주변지역 주민의 호흡기계질환에 대한 설문조사 및 건강검진 결과 분석)

  • Lee, Kwan;Lim, Hyun-Sul;Kim, Min-Gi;Min, Young-Sun;Lee, Young-Hyun;Kim, Sung-Woo;Choi, Hye-Sook;Ahn, Yeon-Soon;Sakong, Joon;Yu, Seung-do;Kim, Geun-Bae;Yoon, Mi-Ra
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.355-365
    • /
    • 2015
  • Objectives: This study was conducted to better understand the relationship between health effects and exposure to dusts from a briquette fuel complex in Ansim, Daegu, Korea. Methods: The subjects of this study consisted of 2,980 persons over 40 years old who had lived 20 years or more around a briquette fuel complex in Daegu. We conducted a questionnaire survey, and chest radiography was performed. In addition, chest computed tomography(CT) (335 cases) and pulmonary function test(PFT) (658 cases) were done. Pneumoconiosis was diagnosed if one of three radiologists determined(or suspected) pneumoconiosis. We also conducted in-depth interviews for pneumoconiosis cases. We defined the exposed group as subjects residing within a 500 meter radius from the walls of the briquette fuel complex, and the others were defined as the control group. Results: Subjects in the exposed and control groups are respectively 715(24%) and 2,265 cases(76%). Major respiratory symptoms in the exposed group such as sputum, dyspnea, chest tightness and wheezing were significantly higher than in the control group. By chest radiography, 173 cases of pneumoconiosis or suspicious pneumoconiosis were detected. By PFT, 62 cases(29.5%) of chronic obstructive pulmonary disease(COPD) among 210 asymptomatic subjects were detected. Finally, by chest CT we concluded 28 cases to be pneumoconiosis, and eight cases among them proved to be pneumoconiosis by environmental exposure. Conclusions: Through this study, we concluded that health outcomes such as respiratory symptoms, pneumoconiosis, and COPD were caused by continuous exposure to dusts from the briquette fuel complex. Policies to reduce environmental exposure are needed, and cases of environmental disease should be intensively followed up by the government.

Durability and Crack Control of Concrete Using Fluosilicates Based Composite (규불화염계 복합 조성물을 혼입한 콘크리트의 균열제어 및 내구성)

  • Yun, Hyun-Do;Yang, Il-Seung;Kim, Do-Su;Khil, Bae-Su;Han, Seung-Gu
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.57-64
    • /
    • 2006
  • The crack presented in concrete structures causes a structural defect, the durability decrease, and external damages etc. Therefore, it is necessary to improve durability through the effort to control the crack. Fluosilicic acid($H_2SiF_6$) is recovered as aqueous solution which absorbs $SiF_4$ produced from the manufacturing of industrial-graded $H_3PO_4$ or HF. Generally, fluosilicates prepared by the reaction between $H_2SiF_6$ and metal salts. Addition of fluosilicates to cement endows odd properties through unique chemical reaction with the fresh and hardened cement. Mix proportions for experiment were modulated at 0.45 of water to cement ratio and $0.0{\sim}2.0%$ of adding ratio of fluosilicate salt based inorganic compound. To evaluate correlation of concrete strength and adding ratio of fluosilicate salt based inorganic compound, the tests were performed about design strength(21, 24, 27 MPa) with 0.5% of adding ratio of fluosilicate salt based inorganic compound. Applications of fluosilicate salt based inorganic compound to reduce cracks resulted from plastic and drying shrinkage, to improve durability are presented in this paper. Durability was evaluated as neutralization, chloride ion penetration depth, freezing thawing resistant tests and weight loss according reinforcement corrosion. It is ascertained that the concrete added fluosilicate salt based inorganic compound showed m ability to reduce the total area and maximum crack width significantly as compared non-added concrete. In addition, the durability of concrete improved because of resistance to crack and watertightness by packing role of fluosilicate salt based inorganic compound obtained and pozzolanic reaction of soluble $SiO_2$ than non-added concrete.

A Study of Adverse Health Symptoms of Spray Painters Using Isocyanates(HDI) (분사페인트에 의한 이소시안화물의 노출이 건강에 미치는 영향에 관한 연구)

  • Lee, So-Gil;Pisaniello, Dino;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.79-86
    • /
    • 2008
  • In the manufacturing industries using HDI(hexamethylene diisocyanate) product hardeners, exposure to HDI is common to spray painters in terms of inhalation and dermal or ocular contact. Due to a lack of information for spray painters in automobile and furniture industries, a questionnaire survey was conducted for the prevalence of adverse health symptoms(33 spray painters and an unexposed group n = 91) to assess the importance of personal controls. Despite the small sample size, common health symptoms were reported, such as skin symptoms(dry cracked skin-61% and dermatitis/skin irritation-33%) and respiratory symptoms(phlegm-49%, asthma-21%). In addition, other adverse health symptoms were reported, such as skin rash(12%), cough(39%), shortness of breath with wheezing(30%), chest tightness and difficulty in breathing(30%). No significant eye symptoms were reported. It was founded that the adverse health symptoms reported in this study were related to poor personal work practices and inappropriate PPE use. Therefore, appropriate personal controls like PPE use, work practices, regular training and education are suggested to minimize the risk of health symptoms. In addition, medical examination will also be suggested for individual health effects.

Study on Hydration Heat of Blended Belite Binder (벨라이트계 혼합 결합재의 수화열 특성에 관한 연구)

  • Lee, Kewn-Chu;Cho, Jae-Woo;Jung, Sang-Hwa;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.145-150
    • /
    • 2011
  • Presently, mass concrete structures are being built in federal and private projects of civil infrastructures and building structures. The hydration heat of mass concrete structures is the most important factor in the quality of concrete matrix and construction period. Moreover, internal cracks caused by hydration heat degrades durability, water tightness, and strength of concrete. To reduce hydration heat, it is necessary to blend belite cement (${\beta}-C_2S$) with industrial by-products (i.e. granulated slag and fly ash). In this experiment, 14 levels of binary binders and 4 levels of ternary binders were used to understand the effect of different replacement ratio on hydration heat, strength and microstructure (i.e. SEM and XRD) of mortar. Cumulative hydration heat at 28 days for the binary and ternary binders was affected by replacement ratio of fly ash and/or granulated slag. As fly ash content increased, hydration heat decreased. As granulated slag content increased, reduction rate of the hydration heat was lower than when fly ash was used. Especially, the hydration heat of ternary binder blended with 40% flyash and 30% granulated slag showed about 50% of hydration heat from using belite cement (P). The study results showed that the temperature rise of concrete matrix can be decreased by using blended belite binders producing low hydration heat and reasonable strength.

Assembly and Test of the In-cryostat Helium Line for KSTAR (KSTAR 저온용기 내부의 헬륨라인 설치 및 검사)

  • Bang, E.N.;Park, H.T.;Lee, Y.J.;Park, Y.M.;Choi, C.H.;Bak, J.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • In-cryostat helium lines are under installation to transfer a cryogenic helium into cold components in KSTAR device. In KSTAR, three kinds of helium should be supplied into the cold components, which are supercritical helium Into superconduction(SC) magnet system, liquid helium into current lead system, and gas helium into thermal shields. Cryogenic helium lines consist of transfer lines outside the cryostat, in-cryostat helium lines, and electrical breaks. In-cryostat helium lines should be guaranteed of leak tightness for tong time operation at high internal helium pressure of 20 bar. We wrapped the helium line with multi-layer insulator(MLI) to reduce radiation heat and insulated the surface of the high potential part with prepreg tape. The electrical break was fabricated by brazing ceramic tube with stainless steel tube. To ensure the operation reliability at operation temperature, all the electrical break have been examined by the thermal cycle test at liquid nitrogen and by the hydraulic test at 30 bar. And additional surface insulation was prepared with prepreg tape to give structural safety. At present most of the in-cryostat helium lines have been installed and the final inspection test is progressing.