• Title/Summary/Keyword: Tightness

Search Result 438, Processing Time 0.024 seconds

Anatomy and Biomechanics of the Patellofemoral Joint (슬개대퇴관절의 해부학과 생체역학에 관한 문헌적 고찰)

  • Choi, Byung-Ok
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.935-944
    • /
    • 2001
  • The patellofemoral pint is formed by the articulation of the patella and femoral condyles in the trochlear groove. The complexity of the patellofemoral pint is magnified by the fact that the tibiofemoral pint works in conjunction with the patellofemoral pint. Additionally, other pints such as the subtalar pint., hip and sacroiliac pints indirectly contribute to the function of the patellofemoral pint. This pint has little bony stability, Soft tissue surrounds the pint to increase stability. The patellofemoral pint increases the mechanical advantage of the quadriceps muscles and resists mechanical loading. In patellofemoral dysfunction, patellofemoral contact pattern is disrupted. leading to excessive compression at the pint. When you treat the patellofemoral dysfunction, you should evaluate anatomic and biomechanic components and find factors of patellofemoral dysfunction. Hamstring tightness. weakness of VMO and tightness of lateral retinaculum lead to flexed knee and abnormal patella tracking and patellofemoral pint reaction force and patellofemoral dysfunction. A through understanding of the anatomy and biomechanics may assist the clinician in the recognition and treatment of patients with patellofemoral pain. Therefore physical therapists should apply modality as well as therapeutic exercise, stretching and strengthening. In this paper, I will discuss the germane anatomical structures and biomechanics of the patellofemoral pint.

  • PDF

A Study on Development of High Pressure Hydrogen Injection Valve (직접분사식 고압 수소분사밸브의 개발에 관한 연구)

  • Kim, Yun-Young;Ahn, Jong-Yun;Lee, Jong-Tai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.11 no.3
    • /
    • pp.107-117
    • /
    • 2000
  • Ball poppet valve type high pressure hydrogen injection valve actuated by solenoid has been developed for the feasibility of practical use of hydrogen fueled engine with direct injection and the precise control of fuel injection ratio in hydrogen fueled engine with dual injection. The gas-tightness of ball poppet injection valve is improved by the introduction of ball-shaped valve face, valve end typed spherical pair, and valve stem with rotating blade. Ball poppet valve is mainly closed by differential pressure due to the area difference between valve fillet and pressure piston. So, it can be operated by solenoid actuator with small driving force. From the evaluation of ball poppet injection valve, it was found that the gastightness and controlment of this injection valve are better than those of injection valve had been developed before.

  • PDF

Investigation of the required performance to develop a performance-based indicator for balcony window systems in apartment houses (공동주택 발코니 창호의 성능기반지표 개발을 위한 요구성능 조사)

  • Moon, Hyeun-Jun;Ryu, Seung-Ho;Yang, Gi-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.102-107
    • /
    • 2009
  • Window system is an essential component for lighting, ventilation and thermal environment in buildings. Moreover, as balcony extension in apartment houses become legalized, the performance requirements of window systems in balcony space are getting complicated. However, at this moment, five properties of the windows are used to represent the performance aspects of the system, including wind resistance, air tightness, water tightness, sound insulation, thermal resistance. And such single properties are not capable to express the performance of a space with the window systems in terms of performance concept. A performance analysis with wholistic approach is required to see the effect of the window system in built environment. Thus, performance-based approach should be established, which will be able to evaluate the goal/function and comfort of occupants/owners. As the first step to develop the performance indicator for the window systme for balcony space, this study conducts a survey to find the required performance aspects. A complete set of performance-based indicators will be developed with verification methods in the later stage of research.

  • PDF

Analysis on Non-malignant Respiratory and Drowsiness Rate Symptom for Passengers Using Subway in Seoul (서울 지하철을 이용하는 승객들의 비악성 호흡기질환과 졸음 증상 유병물 분석)

  • Park, Dong-Uk;Jin, Ku-Won;Yoo, Kyong-Nam
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.412-417
    • /
    • 2006
  • A self-administrated non-malignant respiratory symptoms questionnaire was sent to 1,099 citizens who take subway running in Seoul city. Symptom prevalence rate was high: 70.6% of subjects reported 'chest tightness', 43.4%, 'dysphnea'; 76.2%, 'dry cough'; 49.5%, 'runny nose'; 94.4%, 'drowsiness' when they take subway. The groups responding significant higher respiratory and drowsiness symptoms were 'young passengers' (vs elderly passengers), 'the female' (vs male), 'using subway everyday' (vs often), 'using subway for rush-hour time' (vs other than rush-hour), 'using transfer subway' (no transfer), 'using underground track' (vs ground track). Logistic. regression model was employed to find personal and subway characteristics affecting non-malignant respiratory symptoms. This study concluded that respiratory diseases history such as asthma, rhinitis, sinusitis, hypersensitivity pneumonitis significantly affect 'dry cough' and 'runny nose'. Thus, passengers with respiratory diseases history shows 2.8 times greater 'dry cough' than and 3.4 times greater 'runny nose' than those passengers without respiratory diseases history felt. This results indicated that several measures have to take to protect sensitive groups such as passengers with respiratory diseases, children and elderly people. Also passenger who use to transfer shows 1.7 times higher runny nose symptoms than that passenger who do not transfer felt.

A Study on the Characteristics of the interface in Tube / Tubesheet of the Nuclear Steam Generator by Explosive Bonding (폭발접합된 원자력 증기발생기 튜브/튜브시트 계면 특성에 관한 연구)

  • 이병일;공창식;심상한;강정윤;이상래
    • Explosives and Blasting
    • /
    • v.17 no.4
    • /
    • pp.32-50
    • /
    • 1999
  • This study deals with interface charactristics of tube and tubesheet of the nuclear steam generator by the explosive expansion in order to take advantage of optimum expansion ratio, pull-out strength and leakage tightness and improvement of the resisitance on the stress corrosion cracking for low residual stress. The paper also show the relationship between roll, hydraulic and explosive expansion. The results obtain are as follows (1) Because of the explosive bonding is to use the high speed pressure and energy by the explosive, workability is good, bonding region is homogenous (2) Expansion ratio is 2.7%, Pull-out strength 850kg, Leakage strength $500kg/cm^2$. Clearance gap is 10~30mm in case of explosive expansion and interface structure of the tube and tubesheet is optimum condition. (3) As the transition region of the explosive expansion is inactive, the resistance of the stress corrosion cracking is increases 30~40% compare to the roll and hydraulic expansion.

  • PDF

An Experimental Study of Window Air Tightness according to Filling Piece Shapes (창호 풍지판 형상에 따른 기밀성의 실험적 연구)

  • Yun, Yura;Park, Jong-Jun;Kim, Young Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.63-68
    • /
    • 2016
  • To study the effect of installation and the shapes of filling pieces used for windows on the infiltration rate, infiltration tests were performed with two types of sliding windows and two shapes for the filling pieces. Infiltration occurred most at the top and bottom parts of the center location where two windows overlap, indicating the necessity of a filling piece to be installed at these locations. Infiltration velocity is proportional to the square root of the pressure difference, complying well with the theoretical correlation. Infiltration is reduced about 50% by the filling piece installation. This study shows that filling pieces are essential and their shapes play significant roles in reducing the infiltration of windows.

E/V Shaft Cooling Method as a Stack Effect Countermeasure in Tall Buildings

  • Lee, Joonghoon;Song, Doosam;Jeong, Eunyoung
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • The higher the building height and the larger the temperature difference between the outdoor and indoor space, the more remarkable is the draft driven by the stack effect in high-rise buildings. Moreover, the stack effect can bring about the deterioration of habitability and the degradation of the performance of the indoor control system in high-rise buildings. In this study, as a measure to attenuate the stack effect, the E/V shaft cooling method was proposed and its performance was compared with the conventional stack effect control method for strengthening the air-tightness of the building using a numerical simulation method. The total decreasing ratios on the stack effect in a building were compared, and the probabilities of the secondary problems were analyzed. The results show that the E/V shaft cooling is very effective to decrease the stack effect in a high-rise building in terms of the reduction performance and application. Moreover, this method does not cause secondary problems, such as stack pressure transition to other walls, unlike the conventional stack effect mitigation method.

The Effects of Static Hamstring Stretching on Hip Motion and Lumbo-Pelvic Kinematics

  • Oh, Jaeseop;Kang, Minhyeok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.3
    • /
    • pp.2102-2106
    • /
    • 2020
  • Background: Static hamstring stretching exercises have been widely used to improve flexibility of the hamstring muscles. However, few studies have examined the influence of standing static hamstring stretching (e.g., jack-knife stretching) on movements of the lumbopelvic-hip complex. Objectives: To examine the short-term effects of jack-knife stretching on movements of the lumbopelvic-hip complex. Design: Case series. Methods: Fourteen participants with hamstring tightness (8 male, 6 female) were recruited. Participants performed jack-knife stretching for 150 s. Before and after stretching, participants performed the finger-to-floor distance (FFD), sit and reach (SRT), active knee extension (AKE), passive straight leg raising (PSLA), and active straight leg raising (ASLR) tests as well as pelvic tilt while standing to identify the effects of stretching. Results: There were significant improvements in the FFD, SRT, AKE, PSLA, and ASLR tests after stretching. However, pelvic tilt angle while standing did not significantly change. Conclusion: Jack-knife stretching can be a useful exercise to improve flexibility of the hamstring muscles, but not pelvic alignment while standing.

The Optimization Study on the Test Method of Remanufactured Power Steering Oil Pump by Using FMEA (FMEA를 활용한 재제조 파워스티어링 오일펌프 시험법에 대한 최적화 연구)

  • Seo, Youngkyo;Jung, Dohyun;Yu, Sangseok;Rha, Wanyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.90-98
    • /
    • 2016
  • Currently government certified test method for an automobile remanufactured products is insufficient. Thus many automotive parts in the remanufacturing market are lacking proper evaluation criteria and production of defective products are causing customer dissatisfaction. In this paper a power steering oil pump, which requires stringent manufacturing standards, is studied by the failure mode and effect analysis approach. The research suggested that the test criteria such as discharge flow characteristic test, tightness test, pulley run-out test, pressure switch operation test, low temperature test and rotation pressure durability test should be performed to evaluate the reliability of remanufactured power steering oil pumps. As a result of tests, the performance of remanufactured power steering oil pump satisfied the evaluation criteria of pressure switch operation test and low temperature test. However, the remanufactured power steering oil pump failed to satisfy the evaluation criteria on discharge performance test, tightness test and pulley run-out test. These performance evaluation tests proved the necessity of standard process for the remanufactured power steering oil pump.

Innovative technologies for spent fuel safe management at Ignalina channel-type reactors

  • Babilas, Egidijus;Dokucajev, Pavel;Janulevicius, Darius;Markelov, Aleksej;Pabarcius, Raimondas;Rimkevicius, Sigitas;Uspuras, Eugenijus;Vaisnoras, Mindaugas
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.504-511
    • /
    • 2018
  • In Lithuania, all spent nuclear fuel (SNF) resulted from the operation of the Ignalina Nuclear Power Plant (INPP), which had two Russian Acronym for "Channelized Large Power Reactor"-type reactors. After the final shutdown, the total amount of SNF at the INPP was approximately 22,000 fuel assemblies. All these assemblies will be stored for about 50 years and disposed of after that. The decision to shut down and decommission both reactors in Lithuania before termination of design period raises a significant challenge for the treatment of accumulated SNF. Therefore, various techniques and technologies for SNF management were developed and justified for that specific case, and a set of special equipment was installed at the INPP, the effectiveness of which was demonstrated during its operation. This article presents unique techniques related to the management of SNF adopted and commissioned at the INPP after its operation shutdown, namely fuel rod cladding leak tightness control system and special equipment for collection of possible spillage during handling of SNF assembly in the hot cell. The operational experience and measurement results of fuel rod cladding leak tightness control system are presented.