• 제목/요약/키워드: Tied-Hollow Fiber

검색결과 2건 처리시간 0.016초

Flow-Dependent Friction Loss in an Implantable Artificial Lung

  • Lee, Sam-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • 제16권11호
    • /
    • pp.1470-1476
    • /
    • 2002
  • The goal of this work is to design and build an implantable artificial lung that can be inserted as a whole into a large vein in the body with the least effect on cardiovascular hemodynamics. The experimental results demonstrate that the pressure drop is not entirely related to viscosity effects. The friction factor decreases with an increase in the number of tied-hollow fibers at a constant Reynolds number A uniform flow pattern without stagnation is observed at all numbers of tied hollow fibers tested. The tied hollow fiber module, built in this study with 3 cm of outer diameter of module. 380 m of outer diameter of tied hollow fiber, and 700 number of tied hollow fiber with length of 60 cm, which shows a pressure drop of 13-16 mmHg, satisfies the required pressure drop qualifying 15 mmHg as an intravascular artificial lung.

외부흐름 중공사 막형 인공폐의 액체흐름과 압력손실 (Liquid Flow and Pressure Drop of an Outside Flow Membrane Oxygenator with Hollow Fibers)

  • 이삼철;김기범
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권1호
    • /
    • pp.27-32
    • /
    • 2002
  • 본 연구에서는 혈관내 혈액 흐름의 압력손실을 최소화하여야 하는 제한 인자를 만족하는 새로운 막형 인공폐에서 액체흐름경향과 중공사 개수에 대한 압력손실 영향을 고찰하고자 하였다 막형 인공폐는 380 $\mu m$의 중공사 외경과 600 mm의 축 방향 길이를 갖는 수 백 개의 중공사로 이루어진 다발이다 중공사 다발은 8가지로 변화시켰으며 흐름은 펌프를 이용하여 조절하였다 혈액대용물질로 글리세롤 용액과 물을 사용하여 압력손실을 측정하였으며 동일한 흐름 경향을 각 중공사들에서 얻었다. 700개의 중공사로 이루어진 막형 인공 폐의 외부 압력손실은 13-16 mmHg이었으며 중공사 개수의 감소에 따른 마찰계수는 중공사와 액체와의 효과적인 접촉이 일어나므로 증가되었다.