• 제목/요약/키워드: Tie-bar

검색결과 61건 처리시간 0.049초

전단보강근이 배근된 외부 보기둥 접합부에 정착된 헤드 철근의 스트럿-타이 모델 (Strut-And-Tie Model for Headed Bar Anchored in Exterior Beam-Column Joint with Transverse Reinforcement)

  • 천성철;홍성걸;오보환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.454-457
    • /
    • 2006
  • This study presents a strut-and-tie model for the development of headed bars in an exterior beam-column joint with transverse reinforcements. The tensile force of a headed bar is considered to be developed by head bearing together with bond along a bonded length as a partial embedment length. The model requires construction of struts with biaxially compressed nodal zones for head bearing and fan-shaped stress fields against neighboring nodal zones for bond stresses along the bonded length. Due to the existence of transverse reinforcements, the fan-shaped stress fields are divided into direct and indirect fan-shaped stress fields. A required development length and head size of a headed bar can be optimally designed by adjusting a proportion between a bond contribution and bearing contribution.

  • PDF

역V형 철골 가새골조의 비탄성거동 및 내진성능향상 방안에 관한 연구 (Inelastic Behavior and Seismic Retrofit of Inverted V Braced Steel Frames)

  • 김남훈;이철호
    • 한국강구조학회 논문집
    • /
    • 제15권5호통권66호
    • /
    • pp.571-578
    • /
    • 2003
  • 본 논문에서는 중심가새골조 가운데 가정 널리 사용되는 역V형 철골 가새골조의 내진거동을 탄소성 후좌굴해석에 의해 고찰하고, 압축가새의 좌굴이 최초로 발생한 층에 소성화가 집중되는 약층화 현상을 완화할 수 있는 효과적 내진보강 방안을 제시하고자 하였다. 즉 좌굴이 발생한 층에 집중되는 비탄성변형을 건물전체로 재분재하는 기능을 갖는 인장재(tie bar)를 삽입하여 내진성능을 효과적으로 개선할 수 있음을 입증하였다. 아울러 압축가새의 좌굴발생 순서를 감안하여 보강 인장재를 경제적으로 설계할 수 있는 실용적 설계방안을 제시하였다.

콘크리트포장 확장부 타이바 설치방법의 개발 (Development of Tie-Bar Installation Method for Concrete Pavement Widening)

  • 황인규;양성철;정진훈;유태석
    • 한국도로학회논문집
    • /
    • 제8권1호
    • /
    • pp.33-43
    • /
    • 2006
  • 신설포장에 시공되는 타이바의 경우에는 콘크리트 타설시 타이바가 슬래브 안에 묻히기 때문에 타이바의 정착강도가 문제되지 않으나, 확장시에는 기존 포장을 천공한 후 충전재를 주입하여 설치하기 때문에 타이바가 충분한 정착강도를 확보 할 수 있도록 설계해야 한다. 만일 삽입된 타이바가 충분한 정착강도를 확보하지 못한다면, 슬래브 간에 하중 전달에 문제가 생길 뿐만 아니라 줄눈 간격이 과도하게 벌어져서 사용성 및 내구성에도 나쁜 영향을 주게 된다. 본 연구에서는 현재 현장에서 설치하는 시공방법에 의해 타이바의 정착강도를 확인하고 이에 대한 대안을 제시 하고자 한다. 실험결과 현장 시공방법으로 설치된 타이바의 정착강도는 소요 정착강도의 42.7%에 불과하였다. 첫 번째 대안으로서 주입기를 이용하여 충전재를 주입하고 마개를 사용하여 충전재가 흘러 나오지 못하게 막는 방법의 경우에는 소요 정착강도를 충분히 만족 하였으나, 현장에서의 품질관리가 쉽지 않을 것으로 판단된다. 두 번째 대안으로 제시된 SL 앵커볼트를 이용하여 타이바를 설치하는 방법은 충분한 정착강도를 확보 할 수 있으며 품질관리 및 시공성이 용이 한 것으로 판단된다.

  • PDF

생태축조블록의 국부적 안정성에 관한 실험적 연구 (An Experimental Study on Local Stability of Eco-block)

  • 이승현;이수형
    • 한국산학기술학회논문지
    • /
    • 제12권6호
    • /
    • pp.2866-2871
    • /
    • 2011
  • 본 연구에서는 생태축조블록을 적용한 보강토 옹벽의 국부적 안정성 검토에 필요한 보강재 인장력 계산법을 정립하고 국부적 안정성 검토와 관련한 주요 설계인자인 보강재와 블록 사이의 연결강도와 블록 접촉면 사이의 전단강도를 시험을 통해 규명하였다. 연결강도 시험결과에 따르면 생태축조블록의 내부를 흙으로 속채움하고 D13 이형철근을 사용할 경우 첨두 하중값은 이형철근의 허용인장력 정도임을 알 수 있었으며 D16 이형철근을 사용할 경우 첨두하중값은 허용인장력의 76% 정도였다. 생태축조블록의 내부를 콘크리트로 속채움하는 경우에 있어서 D10, D13 이형철근을 사용하였을 때의 연결강도는 각각의 이형철근의 허용인장력보다 크게 나타났다. 생태축조블록의 접촉면 전단시험결과를 통해 구한 전단저항 매개변수인 ${\alpha}_u$는 1.7kN/m 이었고 ${\lambda}_u$$27.6^{\circ}$ 이었다.

Nonlinear finite element model of the beam-to-column connection for precast concrete frames with high ratio of the continuity tie bars

  • Sergio A. Coelho;Sergio A. Coelho
    • Computers and Concrete
    • /
    • 제31권1호
    • /
    • pp.53-69
    • /
    • 2023
  • The rotational stiffness of a semi-rigid beam-to-column connection plays an important role in the reduction of the second-order effects in the precast concrete skeletal frames. The aim of this study is to present a detailed nonlinear finite element study to reproduce the experimental response of a semi-rigid precast beam-to-column connection composed by corbel, dowel bar and continuity tie bars available in the literature. A parametric study was carried using four arrangements of the reinforcing tie bars in the connection, including high ratio of the continuity tie bars passing around the column in the cast-in-place concrete. The results from the parametric study were compared to analytical equations proposed to evaluate the secant rotational stiffness of beam-to-column connections. The good agreement with the experimental results was obtained, demonstrating that the finite element model can accurately predict the structural behaviour of the beam-to-column connection despite its complex geometric configuration. The secant rotational stiffness of the connection was good evaluated by the analytical model available in the literature for ratio of the continuity tie bars of up to 0.69%. Precast beam-to-column connection with a ratio of the continuity tie bars higher than 1.4% had the secant stiffness overestimated. Therefore, an adjustment coefficient for the effective depth of the crack at the end of the beam was proposed for the analytical model, which is a function of the ratio of the continuity tie bars.

헤디드 바와 강섬유로 보강된 Dapped End Beam의 구조 거동에 관한 실험적 연구 (Behavior of Reinforced Dapped End Beams with T-headed Bar and Steel Fibers)

  • 최진혁;이창훈;이주하;윤영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.49-52
    • /
    • 2004
  • In this studies, Dapped End Beams(DEB) having disturbed regions were designed by using strut tie model, and the main purpose of this paper is that whether T-headed bars and Steel fibers will be present or not. The ability of DEB with T-headed bars have a superior performance rather than others, such as improved ductility, larger energy adsorption and enhanced post-peak load carrying capability. The capacity of DEB with steel fibers also show increase of ductility, shear strength, fatigue strength and crack. Each DEB with both headed bars and steel fibers, headed bars, and steel fibers as a substitute reinforced steel in the disturbed regions and a DEB with only stirrup and tie reinforced steel were comparable. In contrast, the headed bar stirrups, the tie headed bars and the reinforced steel fibers did not lose their anchorage and hence were able to develop strain hardening and also served to delay buckling of the flexural compression steel. Excellent load-deflection predictions were obtained by increasing the tension stiffening effect to account for high load effects.

  • PDF

띠철근 형상이 철근 콘크리트 사각형 기둥의 연성에 미치는 영향 (Effect of ties on the ductility in reinforced concrete rectangular column)

  • 한창윤;김창훈;박상렬;좌용현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.81-82
    • /
    • 2009
  • 본 연구는 띠철근 형상이 철근 콘크리트 사각형 기둥의 연성에 미치는 영향에 대해 실험을 통해 평가하고자 하였다. 철근 콘크리트 기둥에 대해 띠철근의 형상 및 배근에 관한 기준이 있음에도 불구하고 현재 일부 시공현장에서 사용되어지는 띠철근은 시공의 편의성을 위해 설계와 다른 형상으로 시공되어지고 있는 경우가 많다. 따라서 이러한 띠철근의 형상변경으로 인하여 콘크리트 기둥의 거동에 야기될 수 있는 문제점을 분석하여 안전성을 평가할 수 있는 연구가 필요하였다.

  • PDF

Pullout Test of Headed Reinforcement 2: Deep Embedment

  • Choi, Dong Uk;Shin, InYong
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.1091-1096
    • /
    • 2003
  • Pullout tests of single headed bars using plain concrete blocks indicate that the embedment depth of $10d_b$ is in general required for the headed bars to develop pullout strength equivalent to 125% of bar yield strength. In this experimental study, test results of multiple headed bars installed in reinforced concrete column sections are presented. Test variables included embedment depth, column main reinforcement ratio, and spacing of column ties. 2D29 bars were pulled out at one time from normal strength concrete. Test results indicated that the embedment depths, column tie spacings, and column main reinforcement ratios all influenced the pullout strengths of the headed bars. When the embedment depth was not sufficient, narrow tie spacings especially resulted in increased pullout strengths of the headed bars. Test results also indicated that the embedment depth of 15㏈ was sufficient for the closely spaced two headed bars (head-to-head spacing =$6d_b$) to develop pullout strength equivalent to 125% of the bar yield strength.

  • PDF

전동식 사출기의 특성파악 및 수명예측 (Characterization and Life Prediction for an Electric Molding Machine)

  • 김정석;홍성원;정필중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.794-799
    • /
    • 2001
  • For the development of an electric molding machine with low energy, high performance, and high reliability, characterization, finite element analysis and fatigue strength analyses were performed. Strain was measured by strain gages bonded on electric molding machine and compared with stress analysis results using I-DEAS. The analyses showed good agreement with test results. By means of the comparison, we could draw an adequate boundary condition for the stress analysis of the components of electric molding machine. Additionally, we could verify the load distribution mechanism among the parts. The life prediction results for tie bar and thread zone showed infinite life.

  • PDF