• 제목/요약/키워드: Tidal Volume

검색결과 225건 처리시간 0.036초

Influence of Evjenth-Hamberg Stretching on the Lung Function of Adults with Forward Head Posture

  • Kim, Nyeon Jun;Koo, Ja Pung
    • 국제물리치료학회지
    • /
    • 제9권4호
    • /
    • pp.1663-1668
    • /
    • 2018
  • This study was conducted to examine the effects of Evjenth-Hamberg stretching of the sternocleidomastoid, upper trapezius, and pectoralis major on the lung function of adults with forward neck posture. The subjects were 20 adult students in P university located in Pohang, Korea, whose degree of head forward displacement measured according to NEW YORK state posture test was mild. The subjects were randomly and equally assigned to the Evjenth-Hamberg Stretching group (EHSG, n=10) and the control group (CG, n=10). Their forced vital capacity (FVC), slow vital capacity (SVC), and maximal voluntary ventilation (MVV) were measured before and after the experiment. In within-group comparison, only the EHSG experienced statistically significant improvement in FVC, forced expiratory volume in the first second (FEV1), and peak expiratory flow (PEE) after the experiment, compared to before the experiment (.05

폐쇄용적(Closing Volume)이 증가된 만성 폐질환 환자에서 체위에 따른 폐환기량의 변화 (Effect of Posture on the Distribution of Pulmonary Ventilation in Patients with Increased Closing volume)

  • 김용태;김미경;임채만;고윤석;김우성;류진숙;이명혜;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제40권6호
    • /
    • pp.631-637
    • /
    • 1993
  • 연구배경 : 정상 성인에서 폐환기는 균등하지 않아서, 평상호흡(tidal volume breathing)시 폐상부 보다 하부에서 환기가 더 많이 일어나는 것으로 알려져 있다. 한편 유아에서는 흉곽벽이 단단하지 못하여 폐에 대한 견인력이 부족하므로 평상호흡시 폐저부에 기도폐쇄가 일어나, 폐상부의 환기가 하부보다 더 많은 것으로 보고되었다. 또한 성인에서도 폐쇄용적이 증가하면 평상호흡시 폐하부에 기도폐쇄가 일어나 폐하부보다 폐상부에 환기가 더 많이 일어날 수 있을 것으로 예상할 수 있겠다. 방법 : 이에 연구자들은 이를 증명하기 위하여 정상대조군 및 만성 폐질환 환자군을 대상으로 폐활량측정법(spirometry) 및 폐쇄용적(dosing volume)을 측정하고 환기의 불균형은 체위에 따르므로 $^{133}Xe$ 폐환기주사($^{133}Xe$ ventilation scan)를 정와위(supine), 좌와위(left lateral decubitus) 및 우와위(right lateral decubitus)에서 시행하여 좌우 폐의 환기비를 측정하였다. 결과 : 1) 대상 환자는 정상 대조군 7명(평균 연령$62.9{\pm}6.1$세), 환자군중 폐쇄용적 정상인 6명(폐쇄용적 정상군)(연령 $62.8{\pm}8.2$세), 폐쇄용적 증가된 7명(폐쇄용적 증가군)(연령 $63.0{\pm}15.3$세)이었다. 2) 정상대조군에서 FVC는 평균(${\pm}$표준편차) 추정정상치의 $104{\pm}11%,\;FEV_1\;120{\pm}16%,\;FEV_1/FVC\;112{\pm}5%$, 폐쇄용적 $86.9{\pm}12.5%$으로 모두 정상범위 이었으며, 만성 폐질환 환자중 폐쇄용적 정상군에서는 FVC $62{\pm}11%,\;FEV_1\;54{\pm}17%$$FEV_1/FVC\;84{\pm}23%$로서 제한성 환기 장애 소견을 보였고 폐쇄용적 $92.6{\pm}15.5%$이었으며, 폐쇄용적 증가군에서는 FVC $53{\pm}9%,\;FEV_1\;38{\pm}13%,\;FEV_1/FVC\;69{\pm}16%$로서 폐쇄성 환기장애의 소견을 보였고, 폐쇄용적 $176.1{\pm}36.6%$로 환기용적 증가군에서 폐쇄용적이 유의하게 높았다(p<0.02). 3) $^{133}Xe$ 폐환기 주사상 좌측폐의 환기량이 정상대조군에서는 정와위시 총 환기량의 $48.1{\pm}5.3%$, 좌측 하위시 $54.1{\pm}9.8%$, 좌측 상위시 $40.9{\pm}6.5%$, 폐쇄용적 정상 폐질환군에서는 정와위시 $44.6{\pm}2.1%$, 좌측 하위서 $58.7{\pm}5.6%$, 좌측 상위시 $31.7{\pm}8.3%$, 폐쇄용적 증가 만성 폐질환군에서는 정와위시 $48.7{\pm}4.5%$, 좌측 하위시 $41.7{\pm}9.4%$, 좌측상위시 $60.9{\pm}15.7%$로서 정상대조군과 폐쇄용적 정상 만성폐질환 군에서는 좌측하위시 좌측환기량이 정와위시보다 유의하지는 않으나 증가하였고, 좌측상위시 좌측 환기량이 좌측 하위시보다 유의하게 감소하였으며, 폐쇄용적 증가군에서는 좌측 하위시 좌측의 환기량이 정와위시보다 유의하지는 않으나 감소하였고 좌측 상위시 좌측의 환기량이 좌측 하위시보다 유의하게 증가하여 양환자군 사이에 상반된 소견을 보였다. 결론 : 이상의 결과로서 폐쇄용적이 증가한 성인 만성 폐 질환 환자에서 평상호흡시 폐상부의 환기가 폐하부보다 더 많이 일어나는 것을 관찰할 수 있었다.

  • PDF

신생아 호흡곤란 증후군에서 volume-controlled ventilation과 pressure-limited ventilation의 효과에 관한 비교연구 (Comparative study on effects of volume-controlled ventilation and pressure-limited ventilation for neonatal respiratory distress syndrome)

  • 김재진;황문종;이상길
    • Clinical and Experimental Pediatrics
    • /
    • 제53권1호
    • /
    • pp.21-27
    • /
    • 2010
  • 목 적 : 인공호흡기 사용과 관련된 폐손상에 대한 연구가 활발히 이루어져 왔다. 특히 전통적 압력조절방식의 인공호흡기 사용시 발생하는 용적손상의 중요성이 밝혀지면서 신생아 호흡 곤란 증후군의 치료에서 용적조절방식의 인공호흡기가 부각되고 있다. 이에 저자들은 신생아 호흡곤란 증후군 환아를 대상으로 전통적 압력조절방식의 SIMV와 용적조절방식을 바탕으로 한 PRVC를 비교분석하고자 하였다. 방 법 : 2007년 5월부터 2008년 4월까지 대구파티마병원 신생아 중환자실에 입원한 환아중 출생 체중이 1,500 g 미만이고 신생아 호흡곤란 증후군이 있어 기도삽관에 의한 인공호흡기 치료 및 폐표면 활성제를 투여한 환아 34명을 대상으로 하여 PRVC 사용군 14명, SIMV 사용군 20명으로 나누어 비교하였다. 폐표면 활성제 투여 후 시간경과에 따른 PIP값의 변화, 감압된 PIP의 누적값, 기도발관까지의 기간, 그리고 전체 인공호흡기 사용기간을 조사하였고, 주요 합병증인 폐외 공기 누출, 기관지폐 이형성증, 폐고혈압, 미숙아 망막증, 뇌실내 출혈, 동맥관 개존증의 빈도를 조사하였다. 결 과 : 재태연령, 출생시 체중, 성별, 극소 저출생 체중아 비율, 1분 및 5분 Apgar 점수, 호흡 곤란 증후군 등급, 폐표면 활성제 투여 횟수 및 분만 방법, 산모의 임신성 고혈압, 조기양막파수 유무에서 두 군간의 임상적 특성 차이는 없었다. 폐표면 활성제 투여 전 및 투여 후 48시간까지의 PIP값은 PRVC군에서 보다 낮게 측정되었고, 투여 후 24시간까지 PRVC군에서 PIP의 감압이 더 잘 이루어 졌다(P<0.05). 기도발관까지 걸린 시간과 전체 인공호흡기 사용기간, 합병증의 발생 빈도 및 퇴원시점까지 소요된 시간 비교에서는 의미있는 차이는 없었다. 결 론 : SIMV군에 비해 PRVC군에서 PIP 값이 낮고, 폐표면 활성제 투여 후 감압이 더 잘 이루어졌다. 급변하는 폐유순도에 상응하는 감압에 있어 PRVC군이 더 유리하다고 볼 수 있다. 호흡기 이탈기간 및 합병증의 발생에 있어 차이는 없었으나, 잠재적인 폐의 용적손상과 관련 기존 SIMV군에서 필요 이상의 PIP가 설정되었던 것으로 생각되는 바, 이는 앞으로 더 많은 연구가 필요할 것으로 사료된다.

개흉술후 경막외 몰핀에 의한 진통효과 (Effect of Epidural Mortphine for Post-Thoracotomy Pain)

  • 유웅철;이정은;임승평
    • Journal of Chest Surgery
    • /
    • 제26권4호
    • /
    • pp.303-307
    • /
    • 1993
  • Postoperative pain relief and the side effects of epidurally injected morphine were investigated in 10 patients who received thoracotomy. Epidural morphine injection was given via an epidural catheter after thoracotomy. The pain score[VAS] and repiratory rate were decreased and the SaO2, tidal volume and vital capacity were increased significantly after epidural morphine injection. The analgesia of epidural morphine lasted for 13 hours with average. The side effects of epidural morphine were few and mild, but urinary retention was in 10%[1/10] of total patients.

  • PDF

폐결핵환자에서 폐절제술이 폐기능에 미치는 영향에 관한 연구 (The Effects of Pulmonary Resectional Surgery for Cavitary Tuberculosis on Ventilation and Arterial Respiratory Gases)

  • 이현우
    • Journal of Chest Surgery
    • /
    • 제6권1호
    • /
    • pp.7-14
    • /
    • 1973
  • Ventilatory functions and arterial respiratory gases were studied in 24 patients who underwent resectional surgery for pulmonary tuberculosis. Postoperative measurements were made 24 hours, 72 hours and 7 days after surgery and the results were compared to preoperative values. Twenty-four hours postoperatively, there occurred striking increase in respiratory rate, minute ventilation, dead space ventilation and dead space tidal volume ratio, and the increase in minute ventilation was caused primarily by the increase in respiratory rate. However, alveolar ventilation, oxygen consumption, carbon dioxide elimination and respiratory quotient showed no significant postoperative changes although two of the last values showed slight decreases 24 hours after surgery. The lowest arterial oxygen saturation level was obtained 24 hours postoperatively followed by gradual rises but not to the preoperative levels until 7 days after surgery. A decreased arterial carbon dioxide tension with elevated pit was noted 24 hours after surgery, which returned to the preoperative level on the following measurement.

  • PDF

단순모델을 이용한 하구역 지형변화와 해수유동장 변화 수치모의 (Numerical Simulation of Tidal Current Patterns for Estuary Morphological Changes using Simple 2D Model)

  • 이영복;윤한삼;류청로
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.445-448
    • /
    • 2006
  • 본 연구는 기초적인 연구로 낙동강 하구역을 단순 사각형 만의 형상을 가진 지형으로 설정하고 내부 지형의 변화(수심 및 사주 면적)에 따른 해수유동장을 해수유동 수심적분모델로 구축하여 계산하였다. 계산된 유속장 결과를 바탕으로 내부 지형의 대표단면에서의 단면유량플럭스를 계산하여 상호 비교함으로써 하구역내 사주의 생성 및 발달(내부 지형 용적 변화)에 따른 하구역 입구부에서의 해수용적 변화(순환)의 정도를 평가하고자 하였다.

  • PDF

위급 중환자에 특화된 호흡 모니터링 시스템의 유효성 평가 (Assessment of efficacy of respiration monitoring system customized for patients under critical care)

  • 이인광;박미정;김경옥;차은종;김경아
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1431-1432
    • /
    • 2015
  • A system was developed to continuously monitor the respiratory signal under critical care, followed by performance evaluation for clinical application. Very much accurate pressure measurement was made in the endo-tracheal tube with mean relative error of 0.13%. In the comparative experiment simulating inspiration and expiration, the tidal volume measurement was also accurate within mean relative error of 3%, validating reliable measurement of respiratory signals.

  • PDF

서미스터를 이용한 호흡유량 바이오센서 (Development of Breath Flow Sensor with Thermistor)

  • 송찬이;배황;장근식;김사지
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.468-471
    • /
    • 2008
  • We have developed a breath flow sensor that is cheap, robust and has reasonable accuracy. It based on using two thermistors implanted in a breath nozzle, apart by a small but known distance. The sensors detect the small time interval when the breath tidal wave passes by. Therefore the speed of the breath gas can be determined in a given pipe of known diameter. The sensors are calibrated for a few parameters and their accuracy has been estimated.

  • PDF

새만금 간척사업과 해양환경의 변화상 (Changing Phases in Coastal Environment of the Saemangeum Area by Tideland Reclamation Project Mid-west of Korea)

  • 이흥재
    • Ocean and Polar Research
    • /
    • 제28권3호
    • /
    • pp.353-360
    • /
    • 2006
  • A 33-km long sea dyke is being constructed in the Saemangeum area mid-west of Korea to reclaim a surface area of 40,100 ha which includes well-developed tidal flat and two river estuaries. The northern part of the dyke was closed on 10 June 2003, while the southern part was recently closed on 21 April 2006 by plugging two opening gaps of 2.7 km in length. In this study, firstly we review the outlines of key national projects which described marine environments in the Saemangeum area and secondly we present a summary of remarkable changes in marine environments after the closure of the northern dyke, based on marine environmental data collected during 2002-2005. Details in each discipline of the marine environments are presented both in other papers of this special volume and in a series of annual reports of the Ministry of Maritime Affairs and fisheries.