• Title/Summary/Keyword: TiN-coating

Search Result 436, Processing Time 0.027 seconds

Fabrication of functional nanoparticles by layer-by-layer self-assembly method (LBL 법을 이용한 기능성 나노 입자 제조)

  • Kim, Jin-Ho;Hwang, Jong-Hee;Lim, Tae-Young;Kim, Sae-Hoon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.6
    • /
    • pp.305-310
    • /
    • 2009
  • $TiO_2$ thin films consisting of positively charged poly (diallyldimethylammonium chloride) (PDDA) and negatively charged titanium (IV) bis (ammonium lactato) dihydroxide (TALH) were successfully fabricated on a poly (methyl methacrylate) (PMMA) by layer-by-layer (LBL) self-assembly method. By the measurement of quartz crystal microbalance (QCM), it was found that as the solution pH of TALH decreased, the deposition volume of TALH increased and the thickness of (PDDA/TALH) thin film coated on the surface of PMMA particles increased. The PMMA particles coated with the coating sequence of (PDDA/TALH)n showed the variation of color changes as a function of the number of bilayer. The number of bilayer (n) of (PDDA/TALH) thin films was 10 and 20, the values of $a^*$ and $b^*$ decreased from those of PMMA particles without coating films and the color changes was shifted to green and blue direction in the $a^*$, $b^*$ chromaticity diagram. And then, the number of n increased to 30 and 40, the values of $a^*$ and $b^*$ increased and the color changes was shifted to red and yellow direction, respectively. Finally the PMMA particles coated with $(PDDA/TALH)_{50}$ thin film showed a little same value of $a^*$ and $b^*$ with the PMMA particles without (PDDA/TALH) thin film.

Evaluation of Fatigue Fracture Life for TiN Coated Abutment Screw in Dental Implant

  • Choe, Han-Cheol;Chung, Chae-Heon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.115-116
    • /
    • 2012
  • In this study, fitness and fatigue test were performed to estimate the coating effects of abutment screw for implant system after fatigue test. The purpose of this study was to investigate fatigue fracture phenomena of dental implant fixture used titanium nitride coated abutment screw under cyclic load.

  • PDF

Characterization of multi-layer antireflection coating for crystalline silicon solar cells (결정질 실리콘 태양전지의 다층 반사방지막 특성)

  • Ju, Dae-Hyeon;Yang, Jong-U;Seong, Seung-Gi;Cheon, Hui-Gon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.55-55
    • /
    • 2008
  • 반사방지막은 태양전지 셀 제작에 적용되고 있으며, 효율을 향상시키기 위하여 $SiO_2$, $TiO_2$를 이용한 Multi-layer 반사방지막을 적용하였다. Multi-layer의 효과가 기존의 SiN 반사방지막에 비하여 광수집의 향상에 영향을 주었음을 알 수 있었다.

  • PDF

Properties of TiN Thin Films Fabricated by Oblique Angle Deposition Technique (경사 코팅법으로 제조된 TiN 박막의 물성 연구)

  • Jang, Seung-Hyeon;Yang, Ji-Hun;Park, Hye-Seon;Jeong, Jae-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.75-75
    • /
    • 2011
  • 전이금속(transition metal) 질화물(nitride)은 높은 경도, 내마모성, 부식 저항성 그리고 내열성 등과 같은 우수한 기계적 물성 때문에 많은 연구가 되어 왔다. 이 중 질화 티타늄은 높은 경도, 내식 및 내마모의 우수한 기계적 특성으로 공구(tool)와 같은 제품의 수명 향상을 위한 표면 코팅으로 사용되어 왔으며, 금(gold)색의 미려한 색상을 이용한 제품의 외관 표면처리, 정형외과 및 치과용 보형물의 수명 및 안정성 향상 등 다양한 분야에 응용 되고 있다. 본 연구에서는 Cathodic Arc 코팅 방식을 이용하여 질화 티타늄을 합성하였으며, 경사 코팅에 따른 단층 및 다층 피막(3-layer)의 미세조직 변화와 그 물성을 평가하였다. 아크 소스에 장착된 타겟은 99.5%의 Ti 타겟을 사용하였고, 시편과 타겟 간의 거리는 약 31 cm이며, 시편은 알코올과 아세톤으로 초음파 세척 된 냉연강판과 SUS 304를 사용하였다. 시편을 진공용기에 장착하고 ~10-6 Torr까지 진공배기를 실시하고, Ar 가스를 진공용기 내로 공급하여 ~10-4 Torr에서 시편에 bias (Pulse : 400V)를 인가한 후 아크를 발생시켜 약 5분간 청정을 실시하였다. 플라즈마 청정이 끝나면 시편에 인가된 bias를 차단하고 코팅하였다. 경사 코팅을 위한 시편의 회전각은 $30^{\circ}$, $45^{\circ}$, $60^{\circ}$이며, 질화 티타늄의 두께는 약 $3{\mu}m$로 동일하게 코팅 하였다. 경사 코팅된 박막의 경우는 동일 시간 코팅하였을 경우 경사각이 커질수록 두께가 감소하였다. 경사각에 따라 코팅 층이 성장하였고, Bias를 인가 할 경우에는 경사 입사의 효과가 상쇄됨이 관찰되었다. 또한 경사 코팅에 의해 제조된 티타늄 질화물의 경도는 저하 되었으며, $30^{\circ}$$60^{\circ}$에 비해 $45^{\circ}$ 경우 경도 저하가 가장 적었다. 결론적으로 Cathodic 아크 코팅 방법으로 질화티타늄을 합성하였고, 경사 코팅을 통해 박막의 미세조직 변화를 확인 하였다. 본 연구에서 얻어진 결과를 이용하여 다양한 구조로 박막의 성장을 유도 할 수 있으며, 이를 통해 경도, 내마모성, 내식성 등의 물성을 변화시킬 수 있는 장점을 가질 것으로 예상된다.

  • PDF

Photocatalytic Degradation of Phenol in $UV/TiO_2$ Packed-bed System ($UV/TiO_2$ 충진 반응기에서 페놀의 광산화 반응)

  • Park, Kil-Soon;Kim, Jong-Hwa;Lee, Sang-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.939-945
    • /
    • 2005
  • The Photocatalytic activity was investigated with the increase of flow rate in a $UV/TiO_2$ packed-bed system. The rate of phenol degradation over $UV/TiO_2$ (dia. = 5 mm) was increased up to 300 mL/min and reached a plateau beyond 400 mL/min. The bead photocatalysts did not exhibit a distinct difference of the phenol degradation rate irrespective of corrosion rates of glass beads and $TiO_2$ coating amounts. Degussa P25 exhibited a higher photocatalytic activity in comparison to other $TiO_2$ sols(Ishihara & N). The performance(activity and durability) of $UV/TiO_2$ packed-bed system can be enhanced by the use of $TiO_2$-coated glass beads instead of granular types that is easily attrited by the shearing force of flowing fluids.

Improvement of Electron Emission Characteristics and Emission Stability from Metal-coated Carbon Nanotubes (금속 코팅된 탄소나노튜브의 전계 방출 특성 및 신뢰성 향상)

  • Uh, H.S.;Park, S.;Kim, B.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.436-441
    • /
    • 2011
  • Metal coating with several nanometer thickness was applied on the carbon nanotubes (CNTs) in order to improve electron emission characteristics and emission reliability for the potential applications in the area of various electron sources and displays. CNTs were grown on the 2-nm thick Invar (52% Fe, 42% Ni, 6% Co alloy)-catalized Si substrate by using plasma-enhanced chemical vapor deposition at $450^{\circ}C$. In order to reduce the spatial density of densely packed CNTs, as-grown CNTs were partly etched back by $N_2$ plasma and subsequently coated with 5~150 nm thick Ti by a sputtering method. 5 nm thick Ti-coated CNTs produced four times higher emission current density at the electric field of 6 V/${\mu}m$ and much lower emission current fluctuation, compared with the as-grown CNTs. These improved emission properties are mainly due to not only the work function of Ti (4.3 eV) lower than that of pristine CNTs (5 eV), but also lower contact resistance and better adhesion between CNT emitters and substrate accomplished by Ti coating.

Influence of Silver Ions in HA Film on Morphology of Macrophages

  • Feng, Q.L.;Kim, T.N.;Kim, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.s1
    • /
    • pp.50-56
    • /
    • 1998
  • Ion beam assisted deposition (IBAD) was successfully used to produce a dense and ultra-adherent Hydroxyapatite (HA) film on titanium alloy and alumina. Recently it is also proved that the HA coatings on alumina substrate treated with 20 ppm $AgNO_3$ had the structure of $(Ag, Ca)_10(PO_4)6(OH)_2$, which exhibited excellent antimicrobial effects. The present paper aims to morphlogically characterize the adhesion of macrophages on newly developed Ag-HA coated alumina and Ti6A14V substrates and to evaluate the biocompatibility of the coatings in vitro. It can be found that the cell number on alumina of the concentration of $AgNO_3$ in the treatment, the cell number on Ag-HA coatings decreased. Up to 20 ppm $AgNO_3$ by Ag-treatment, the morphological development of the cells on Ag-HA coating was similar to that of the cells on HA coating, suggesting the biotolerance of the Ag-HA coatings.

  • PDF

A Study on the Cutting Characteristics of Inconel 690 alloy (인코넬 합금의 절삭특성에 관한 연구)

  • 황경충
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.315-319
    • /
    • 1999
  • This paper has been considered on the cutting characteristics such as chip formation and surface roughness for Inconel 690 alloy with difficult-to-cut because of high toughness and strength. We have made efforts solving the problem to difficult-to-cut of Inconel by improvement of tool with TiN coating and the selection of optimum cutting condition. We used the CCD camera and the surface roughness tester to observe the chip formation and the state of machined surface by using the improved tool with diamond coating and various cutting condions. We have found that the chip formation showed the tooth shape of tooth blade and the surface roughness was very poor. but it can be better by selection of optimum cutting condition.

  • PDF

Fractal Analysis of the Surface in Thin Film Capacitors

  • Hong, Kyung-Jin;Min, Yong-Ki;Cho, Jae-Cheol
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.2
    • /
    • pp.18-22
    • /
    • 2001
  • The thin films of high permitivity in ferroelectric materials using a capacitor are applied to DRAMs and FRAMs. (Ba, Sr)TiO$_3$ thin as ferroelectric materials were prepared by the sol-gel method and made by spin-coating on the Pt/Sio$_2$/Si substrate at 4,000 [rpm] for 10 seconds. The structural characteristics of the surface were analyzed by fractal dimension. The thickness of BST ceramics thin films was about 260∼280 [nm]. The property of the leakage current was stable with 10-9∼10-11[A] when the applied voltage was 0∼3[V]. BST thin films ha low leakage current properties when fractal dimension was low and a coating area was high.

The Reactions of the Ti Melt with CaO and Graphite and the Effect of Pressure on the Formation of Gas Porosity (티타늄 용탕의 산화칼슘 및 흑연과의 반응 및 기포 결함의 형성에 미치는 압력의 영향)

  • Bae, Chang-Gun;Kwon, Hae-Wook
    • Journal of Korea Foundry Society
    • /
    • v.20 no.4
    • /
    • pp.247-253
    • /
    • 2000
  • Titanium was melted in the CaO-coated alumina crucible and the reaction between the melt and the coating layer was negligible. The volume fraction of the gas porosity was decreased with increasing pressure and the sound bar castings with no porosity was obtained under the Ar atmosphere of the pressure of $300kN/mm^2$. The surface of the casting obtained from CaO-coated graphite mold was slightly rougher than that from graphite without coating. The reaction product of titanium melt with the layer of CaO was mainly titanium oxide and that with graphite crucible was titanium cabide with small amount of titanium nitride.

  • PDF