• 제목/요약/키워드: TiAgN coating

검색결과 8건 처리시간 0.018초

AIP법으로 형성된 TiAgN 코팅필름의 바이어스전압에 따른 표면 특성 분석 (Surface Characterization According to the Bias Voltage of the TiAgN Coating Film Layer Formed by the AIP Process)

  • 백민숙;윤동주;강병모;정운조;김병일
    • 한국재료학회지
    • /
    • 제25권5호
    • /
    • pp.253-257
    • /
    • 2015
  • The implanting of metal products is performed with numerous surface treatments because of toxicity and adhesion. Recently, the surface modification of metal products has been actively studied by coating the surface of the TiC or TiN film. We prepared a Ti(10%)Ag Target which may be used in dental oral material by, using the AIP(arc ion plating) system TiAgN coating layer that was deposited on Ti g.23. The purpose of this study was to establish the optimal bias voltage conditions of the coated TiAgN layer formed by the AIP process. The TiAgN coatings were prepared with different bias voltage parameters (0V to -500V) to investigate the effect of bias voltage on their mechanical and chemical properties. The SEM(scanning electron microscope), EDS(energy dispersive X-ray spectrometer), XRD(X-ray diffraction), micro-hardness, and potentiodynamic polarization were measured and the surface characteristics of the TiAgN coating layers were evaluated. The TiAgN coating layer had different mechanical characteristics based on the bias voltage, which also showed differences in thickness and composition.

Incorporation of silver nanoparticles on the surface of orthodontic microimplants to achieve antimicrobial properties

  • Venugopal, Adith;Muthuchamy, Nallal;Tejani, Harsh;Anantha-Iyengar-Gopalan, Anantha-Iyengar-Gopalan;Lee, Kwang-Pill;Lee, Heon-Jin;Kyung, Hee Moon
    • 대한치과교정학회지
    • /
    • 제47권1호
    • /
    • pp.3-10
    • /
    • 2017
  • Objective: Microbial aggregation around dental implants can lead to loss/loosening of the implants. This study was aimed at surface treating titanium microimplants with silver nanoparticles (AgNPs) to achieve antibacterial properties. Methods: AgNP-modified titanium microimplants (Ti-nAg) were prepared using two methods. The first method involved coating the microimplants with regular AgNPs (Ti-AgNP) and the second involved coating them with a AgNP-coated biopolymer (Ti-BP-AgNP). The topologies, microstructures, and chemical compositions of the surfaces of the Ti-nAg were characterized by scanning electron microscopy (SEM) equipped with energy-dispersive spectrometer (EDS) and X-ray photoelectron spectroscopy (XPS). Disk diffusion tests using Streptococcus mutans, Streptococcus sanguinis, and Aggregatibacter actinomycetemcomitans were performed to test the antibacterial activity of the Ti-nAg microimplants. Results: SEM revealed that only a meager amount of AgNPs was sparsely deposited on the Ti-AgNP surface with the first method, while a layer of AgNP-coated biopolymer extended along the Ti-BP-AgNP surface in the second method. The diameters of the coated nanoparticles were in the range of 10 to 30 nm. EDS revealed 1.05 atomic % of Ag on the surface of the Ti-AgNP and an astounding 21.2 atomic % on the surface of the Ti-BP-AgNP. XPS confirmed the metallic state of silver on the Ti-BP-AgNP surface. After 24 hours of incubation, clear zones of inhibition were seen around the Ti-BP-AgNP microimplants in all three test bacterial culture plates, whereas no antibacterial effect was observed with the Ti-AgNP microimplants. Conclusions: Titanium microimplants modified with Ti-BP-AgNP exhibit excellent antibacterial properties, making them a promising implantable biomaterial.

흡수층을 이용한 무반사, 무정전용 광학박막의 설계 (The design of the optical film for absorbent ARAS coating)

  • 박문찬;손영배;정부영;이인선;황보창권
    • 한국안광학회지
    • /
    • 제5권1호
    • /
    • pp.7-11
    • /
    • 2000
  • ITO, $TiN_xW_y$, Ag 등의 전도성 흡수층으로 무반사, 무정전 광학박막을 Essential Macleod 프로그램을 이용하여 설계했다. 그 결과 [공기 ${\mid}SiO_2{\mid}TiN_xW{\mid}$ 유리] 층은 단 두층코팅막으로 가시광선 파장영역(45~700nm)에서 넓게 무반사 코팅이 되었다. 이 때 반사률과 투과률은 각각 0.5% 미만과 약 75%이다. [공기 $SiO_2{\mid}TiO_2{\mid}SiO_2{\mid}ITO {\mid}$ 유리] 층은 약 0.5% 미만의 반사률이 있는 무반사 코팅이 되며 투과률은 97% 이상이며, 450nm 파장 영역부근에서 투과률이 비교적 낮은 것은 ITO의 흡수계수 영향 때문이다. 또한 [공기 $SiO_2{\mid}TiO_2{\mid}SiO_2{\mid}Ag{\mid}$ 유리] 층은 반사률이 1~2%인 AR코팅이며 투과률은 96% 이상이다.

  • PDF

Aging 효과에 따른 나노메탈(Au, Ag)-이산화티탄 복합체의 항균 활성도 (Aging Effect on the Antimicrobial Activity of Nanometal (Au, Ag)-Titanium Dioxide Nanocomposites)

  • 박혜림;이상화;유인상
    • 공업화학
    • /
    • 제23권3호
    • /
    • pp.293-296
    • /
    • 2012
  • 항균 활성도를 조사하기 위해 이산화티탄미립자 표면에 나노메탈(Au, Ag)을 균일하게 도핑한 나노복합체($Ag-TiO_2,\;Au-TiO_2,\;Ag-TiO_2$@$TiO_x$)를 초음파환원법과 졸-겔 법으로 제조하였다. 이렇게 제조된 나노메탈-이산화티탄 복합체의 항균 활성도는 고체배지 표면에 나노복합체와 함께 E. coli를 도말하여 $37^{\circ}C$에서 배양한 후 생존된 콜로니 개수의 측정을 통해서 이루어졌다. 나노복합체의 초기 항균 효율은 나노메탈이 도핑된 이산화티탄미립자($Ag-TiO_2,\;Au-TiO_2,\;Ag-TiO_2$@$TiO_x$)) 복합체가 도핑하지 않은 이산화티탄미립자($TiO_2$)에 비해 높은 항균 효율을 나타내주었다. 이후, 나노복합체를 $4^{\circ}C$에서 보관 후 장기보관에 따른 항균특성을 비교해본 결과, 나노메탈만 도핑된 복합체($Ag-TiO_2,\;Au-TiO_2$)보다는 $Ag-TiO_2,$의 표면을 다시 산화티탄막으로 코팅한 복합체($Ag-TiO_2$@$TiO_x$)의 항균특성이 오랫동안 유지되는 것을 알수 있었다. 이는 산화티탄막으로 다시 코팅한 $Ag-TiO_2$@$TiO_x$의 경우에 Ag 나노메탈의 산화방지 및 나노복합체의 콜로이드 안정성 향상이 이루어졌기 때문으로 사료된다.

Influence of Silver Ions in HA Film on Morphology of Macrophages

  • Feng, Q.L.;Kim, T.N.;Kim, J.W.
    • 한국진공학회지
    • /
    • 제7권s1호
    • /
    • pp.50-56
    • /
    • 1998
  • Ion beam assisted deposition (IBAD) was successfully used to produce a dense and ultra-adherent Hydroxyapatite (HA) film on titanium alloy and alumina. Recently it is also proved that the HA coatings on alumina substrate treated with 20 ppm $AgNO_3$ had the structure of $(Ag, Ca)_10(PO_4)6(OH)_2$, which exhibited excellent antimicrobial effects. The present paper aims to morphlogically characterize the adhesion of macrophages on newly developed Ag-HA coated alumina and Ti6A14V substrates and to evaluate the biocompatibility of the coatings in vitro. It can be found that the cell number on alumina of the concentration of $AgNO_3$ in the treatment, the cell number on Ag-HA coatings decreased. Up to 20 ppm $AgNO_3$ by Ag-treatment, the morphological development of the cells on Ag-HA coating was similar to that of the cells on HA coating, suggesting the biotolerance of the Ag-HA coatings.

  • PDF

금속 코팅을 통한 다양한 반도체/금속 나노선 제작 (Fabrication of Various Semiconductor/Metal Structured Nanowires Using Metal Coating)

  • 박병준;김경환;김현석;조경아;김진형;이준우;김상식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.252-255
    • /
    • 2004
  • Various Semiconductor/Metal structured nanowires were synthesized from the simple thermal annealing of ball-milled compound powders and the thermal evaporation of metals. Their structural properties were investigated by Scanning Electron Microscopy(SEM) and Transmission Electron Microscopy(TEM), Energy Dispersive X-ray spectroscopy(EDX). Depending on the type of metals and the material of nanowires, uniform somiconductor/metal nanowires(GaN/Al, GaN/Ag) or isolated metal particles on semiconductor nanowires$(SnO_2/Ti,\;Si/Ti)$ were formed on the surface of nanowires.

  • PDF

Determination of Hg22+ Ions Using a Modified Glassy Carbon Electrode with 2,2':6':2''-Terpyridine

  • Kong, Young-Tae;Bae, Yun-Jung;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권2호
    • /
    • pp.346-350
    • /
    • 2002
  • A glassy carbon electrode (GCE) modified with 2,2':6':2”-terpyridine (2,2':6':2”-TPR) using a spin coating method was applied for the highly selective and sensitive analysis of a trace amount of $Hg_2^{2+}$ ions. Various experimental parameters, which influenced the response of the 2,2':6':2”-TPR modified electrode to $Hg_2^{2+}$ ions, were optimized. The linear sweep and differential pulse voltammograms for the 2,2':6':2”-TPR modified electrode deposited with Hg show a well-defined anodic peak at +0.65 V (vs. Ag|AgCl). After a 25 min preconcentration time in an $Hg_2^{2+}$ ion solution (0.1 M acetate buffer, pH 5.0), differential pulse voltammetry(DPV) with 2,2':6':2”-TPR modified electrode shows a linear response between $1.0\;{\times}\;10^{-6}M\;and\;2.0\;{\times}\;10^{-7}M$. The least-square treatment of these data produce an equation of I[${\mu}A$] = 0.031 + 0.005C with r = 0.980(n = 5). The detection limit of this electrode with linear sweep voltammetry and differential pulse anodic voltammetry were $2.0\;{\times}\;10^{-6}M\;and\;8.0\;{\times}\;10^{-8}M$, respectively. The presence of Pb, Fe, Cd, Ti, Ni, Co, Mg, Al, Mn, and Zn did not interfere in the analysis of the $Hg_2^{2+}$ ion. The 2,2':6':2”-TPR modified GCE has been successfully applied in determination trace amounts of Hg in a human urine sample.

초고진공계재료 (UHV Materials)

  • 박동수
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.24-24
    • /
    • 1998
  • 반도체장비를 포함하는 초고진공장비의 園훌化가 급속히 그리고 절실히 요구되고 있는 것이 현실정이다. 當面해서 실현할 국산진공장비의 대상은 廣範圍하다. 즉, 각종 진공 pump ( (rotary, dry, diffusion, cryo, ion, turbo melecular pump), 진공 chamber, 진공 line, gate valve 를 위 시 한 진공 V머ve, flange, gasket, fl않d야lU, mainpulater 퉁 진공 部品이 다. 진공계 의 핵심 은 適切하고 優良한 진공재료의 선태파 사용이다. 진공장비는 사용자가 원하는 진공도를 원하 는 시간 동안 륨空度를 유지해 주어야 한다. 진공재료 선태의 기준사항은:(1) 기체의 透過성 (2) 薰했훌 (3) 혔體放出특성 - -outgassing과 degassing- (4) 機械的 량훌度 (5) 온도 의존성 (6) 化學톡성 (7) 加I성 및 鎔接 성 (8) 課電특성 (9) 磁氣특성 (10) 高速함子 및 放射線 특성 (11) 經濟성 및 調達생 둥이 다. 우량한 초고진공계재료는 풍부하게 개발되어 왔고, 또 新材料들이 개발되고 있다. 여기에서는 주로 초고진공 내지는 극고진공계의 構造材料, 機能材料, 部品材料 일반파 몇가지 신재료의 특 성에 관해서 記述한다. M Mild SteeHSAE, 1112, 1010, 1020, 1022, etc)., S Stainless SteeHAlSI, 304, 304L, 310, 316, 321, 347): 구조재료, chamber, fl하1ges A Aluminum과 Alloys (1060, 1100, 2014, 4032, 6(뻐1): 구조재료, chamber, flanges, gaskets A AI, Al 떠loy는 SS에 代替하는 역 할올 시 작하고 있다. C Copper, Copper Alloys(C11$\alpha$)0, C26800, C61400, Cl7200): 내장인자, gasket, cryopanel, tubing T Titanium, Ziriconium, Haf띠um 및 Alloys: 특히 Ti은 10n pump 용 getter material 이 외 에 U UHV,XHV용 chamber계로서 관심올 끌고 있다. N Nickel, Nickel Alloys (200, 204, 211, monel, nichrome): 부식 방지 , 전자장치 , 자기 장치 귀 금속(Ag, Au, Pt, Pd, Rh, Ir, Os, Ru): 보조부품, gasket, filament, coating, thermocouple, 접 합부위 T TiC, SiC, zrC, HfC, TaC 둥의 탄화물과, BN, TiN, AlN 동의 질화물, 붕화물이 둥장하고 었 다. 유리: Soda Lime, Borosilicate, Potash Soda Lead: View Port, Chamber envelope C Ceramics: AlZ03, BeO, MgO, zrOz, SiOz, MgOzSiOz, 3Alz032SiOz, Z$textsc{k}$hSiOz S상N4: e electrical, thermal insulators, crucibles, boats, single crystals, sepctr려 windows 저자는 최근 저자들이 발견한 Zr-Ti-Cu-Ni-Be amorphous alloys coated cham뾰r가 radiation p proof로 이용될 수 있는 사실을 점검하고 었다 .. Z.Y. Hua 들은 Cs3Sb를 새로운 photocathode 재료로 보고하고 있다.

  • PDF