• Title/Summary/Keyword: Thyroid Uptake

Search Result 142, Processing Time 0.019 seconds

Clinical Observation on Subacute Thyroiditis (아급성(亞急性) 갑상선염(甲狀腺炎)의 임상적(臨床的) 고찰(考察))

  • Kim, Sam-Yong;Jung, Jun-Ki;Suk, Chang-Ho;Hong, Kee-Suck;Lee, Hong-Kyu;Koh, Chang-Soon;Park, Seong-Hoe;Kim, Yong-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.12 no.2
    • /
    • pp.41-46
    • /
    • 1978
  • 8 cases of subacute thyroiditis was diagnosed among 108 needle biopsy of the thyroid during the period from April 1976 to August 1978. Correlation of the histologic findings with the clinical staging proposed by Czernick was relatively well matched; cases with long clinical course or low thyroid hormone levels showed greater fibrosis and reduction of follicular elements in thyroid. Thyroid $^{131}I$ uptake or the uptake as seen on the thyroid scanning correlated inversely with the thyroid hormone levels. The clinical course of the patients seen in their initial stage of disease followed the classical pattern; hyperthyroid-like, hypothyroid-like and recovery. 3 among the 4, who were seen in their later clinical course showed hypothyroidism, which seemed the final outcome of their diseases.

  • PDF

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF

Simultaneous Visualization of the Sublingual Thyroid and Lactating Breasts with Tc-99m Pertechnetate Scintigraphy (설하갑상선과 수유중 유방이 Tc-99m Pertechnetate 스캔에 동시에 관찰된 증례)

  • Seo, Ji-Hyoung;Seong, Young-Ok;Bae, Jin-Ho;Jeong, Shin-Young;Ahn, Byeong-Cheol;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.489-490
    • /
    • 2005
  • Purpose: The thyroglossal duct runs from the base of the tongue to the thyroid. Rarely the thyroid completely fails to migrate and results in ectopic thyroid tissue, which can be demonstrated scintigraphically. A 31-year old female patient was referred for thyroid scintigraphy due to protruding mass at the base of the tongue. She was mildly hypothyroid. Te-99m pertechnetate thyroid scan was performed to rule out ectopic thyroid gland. There showed a focal area of intense tracer uptake in sublingual area, suggesting the sublingual thyroid. In addition there noted diffusely increased tracer uptake in both breasts. The patient delivered a baby 6 months prior to the scan and was on breast-feeding. Free Tc-99m pertechnetate physiologically secrets into the salivary glands, the stomach, the gastrointestinal tract, the genitourinary tract and the mammary glands and sodium-iodide symporter plays a role in the accumulation of free Tc-99m pertechnetate. We report simultaneous visualization of lactating breasts and ectopic thyroid gland in the base of the tongue.

A Case of Ectopic Thyroid with Clinical Evaluation of Fifteen Cases (이소성 갑상선 1례 및 국내 증례의 임상적 고찰)

  • 고중화;안성윤;송정환;박승구
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.1
    • /
    • pp.55-61
    • /
    • 1999
  • The authors recently experienced a case of ectopic thyroid. A 15-year-old female patient visited to ENT department with the complaint of the submental neck mass. On physical examination, the mass was relatively firm, non tender and 3$\times$2cm in size. Oral cavity examination revealed 0.5$\times$0.5cm sized pink colored mass near the foramen cecum area. Suspecting ectopic thyroid, thyroid function test, thyroid scan, neck computed tomogram scan were performed. Thyroid scan revealed a functioning thyroid on the lingual and submental area without normal uptake in the anterior neck area. Thyroid (unction test was normal. Pre-contrast computed tomogram scan revealed an ectopic thyroid in the lingual and submental area. A review of literature concerning ectopic thyroid was discussed.

  • PDF

The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate (갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향)

  • Hwang, Dong Hun;Oh, Shin Hyun;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq ($5{\mu}Ci$) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to $364.4keV{\pm}20%$ energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.

  • PDF

Evaluate Utility of Thyroid Cancer Discrimination by 18F-FDG PET/CT Delay Scan Images (18F-FDG PET/CT검사에서 지연영상을 이용한 갑상선암 진단의 유용성 평가)

  • Lee, Hyeon-Guck;Han, Man-Seok;Kim, Yong-Kyun;Seo, Sun-Youl;Jeon, Min-Cheol;Kim, Tae-Hyung;Hong, Seong-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2958-2965
    • /
    • 2013
  • Purpose : To evaluate the degree of malignancy of incident thyroid lesion found in 18F-FDG PET/CT findings and the usefulness of the method suggested in this study, we applicate the Delay Scan Method that differentiate a false positive benign tumor, inflammation and malignancy, as well as make the criteria of SUV. Materials and Methods : A retrograde study was conducted of 25 patients(1 exception) who were admitted in E hospital to receive 18F-FDG PET/CT examination until Janaary and April of 2008. 18F-FDG PET/CT image photographing was taken in Biograph-Duo made by SIEMENS, after taking normal 18F-FDG PET/CT image(1hr) and then 1hr later we took the thyroid 1 bed-delayed image for the patients who showed abnormal thyroid 18F-FDG uptake and above 2.0 SUV for 2 minutes every 1 bed. For the patients who showed abnormal thyroid uptake and above 2.0 SUV, 1hr later, we took a 1 bed-delayed image and then made a comparative study between measured maxSUV of 1hr-abnormal uptake image and that of 2hr-delayed image. Results : In this 18F-FDG PET/CT study among the patients who showed incidental 18F-FDG thyroidal uptake the number of thyroid cancer was 5(20.8%), all of then showed benign findings. a comparison of results for 18F-FDG PET/CT. the benign patient measured maxSUV in the PET/CT. image(1hr) mean value 5.06maxSUV and delay image(2hr) mean value 5.23maxSUV differences of two value is 0.19maxSUV and the malignantIt patient measured maxSUV in the PET/CT. image(1hr) mean value 9.63maxSUV and delay image(2hr) mean value 10.65maxSUV differences of two value is 10.65maxSUV in Thyroid abnormal uptake patients. Conclusion : in the case of incidental 18F-FDG uptake in thyroid, max SUV of focal thyroid lesion is above 5.0 if 18F-FDG PET/CT examine the delayed images to add, You could see that reasonable diagnostic method useful. to differentiate whether lesions of malignant.

Use of $^{99m}TcO_4^-$ Salivary-Thyroid Ratio As a Test of Thyroid Function (갑상선스캔상에서 갑상선섭취율의 추정방법 : 타액선-갑상선계수율)

  • Yang, Woo-Jin;Chung, Soo-Kyo;Chun, Ki-Sung;Kim, Jong-Woo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.151-154
    • /
    • 1987
  • Total 114 patients were studied prospectively with radioiodine uptake (RAIU) and $^{99m}TcO_4^-$ thyroid scan to design a very simple, rapid and inexpensive method measuring the thyroid uptake on thyroid scan. After the RAIU was obtained at 24 hours after P.O. of $^{131}I$, Thyroid scan was performed at 20 minutes after LV. of $^{99m}TcO_4^-$ and the bilateral salivary glands were included in the scan field. Pinhole collimated and computer assisted gamma camera was used. Three regions of interest were set on each salivary gland and on the thyroid by automatic edge detection method. Mean counts per pixel were calculated for each ROI and the salivary-thyroid ratio (STR) was defined as; $$STR(%)=\frac{Mean\;counts\;per\;pixel\;of\;salivary\;glands\;(KC)}{Mean\;counts\;per\;pixel\;of\;thyroid\;gland\;(KC)}\times100$$ 114 cases consisted of 41 normal, 55 hyperthyroid and 18 hypothyroid patients and correlation between the STR and the RAID were evaluated in total and each group. The STR and the RAID showed reverse linear regression in 114 cases (r= -0.8, P=0) and closer correlation was shown in hyperthyroid group (r= -0_9, p=0). Mean STR in normal group was 47.6%. In predicting the RAID by STR, sensitivity and specificity were 88.3% and 64.9% in 114 cases and 95.3% and 83.3% in hyperthyroid group. It is recommended that the STR be used in place of the RAID giving same information at saving time, money and radiation exposure.

  • PDF

Evaluate Utility of Thyroid Incidentaloma Discrimination by $^{18}F$-FDG PET/CT Delay Scan Images ($^{18}F$-FDG PET/CT검사에서 지연영상을 이용한 갑상선 우연종 감별의 유용성 평가)

  • Lee, Hyun-Kuk;Yang, Seoung-Oh;Song, Gi-Deok;Song, Chi-Ock;Lee, Gi-Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.184-191
    • /
    • 2008
  • Purpose: To evaluate the degree of malignancy of incident thyroid lesion found in $^{18}F$-FDG PET/CT findings and the usefulness of the method suggested in this study, we applicate the Delay Scan Method that differentiate a false positive benign tumor, inflammation and malignancy, as well as make the criteria of SUV. Materials and Methods: A retrograde study was conducted of 800 patients who were admitted in E hospital to receive $^{18}F$-FDG PET/CT examination. One patient who was diagnosed as primary thyroid cancer and received $^{18}F$-FDG PET/CT examination was excluded. The number of final patients of this study was 799, the reasons of $^{18}F$-FDG PET/CT examination of these patients were follow-up of old cancer or suspicious tumorous lesion in 696 and disease screening in 103. $^{18}F$-FDG PET/CT image photographing was taken in Biograph-Duo made by SIEMENS, after taking normal $^{18}F$-FDG PET/CT image (1 hr) and then 1 hr later we took the thyroid 1 bed-delayed image for the patients who showed abnormal thyroid $^{18}F$-FDG uptake and above 2.0 SUV for 2 minutes every 1 bed. For the patients who showed abnormal thyroid uptake and above 2.0 SUV, 1 hr later, we took a 1 bed-delayed image and then made a comparative study between measured $SUV_{max}$ of 1 hr-abnormal uptake image and that of 2 hr-delayed image. Results and Conclusion: In this $^{18}F$-FDG PET/CT study among the patients who showed incidental $^{18}F$-FDG thyroidal uptake the number of thyroid incidentaloma was 5 (0.63%), all of then showed benign findings. And in the case of incidental $^{18}F$-FDG uptake in thyroid, $SUV_{max}$ variance obtained from 2 hr delayed image can be a indirect criteria in differentiating benign tumor from malignancy and decrease finding error. In the cases found thyroid incidentaloma when 1) $SUV_{max}$ of focal thyroid lesion is above 5.0 and 2) $SUV_{max}$ variance between normal $^{18}F$-FDG PET/CT exam and 2 hr delayed is $1.0{\pm}0.5$, they are suspected as malignancy and confirming biopsy is to be followed. Otherwise, I also think that distinct follow-up PET or CT image study is a reasonable diagnostic method.

  • PDF

High Dose Therapy of Radioactive Iodine for Thyroid Ablation in Thyroid Carcinoma (갑상선 악성종양에서 갑상선 전절제술 후 방사성 요오드 치료의 효과)

  • Ahn Hee-Cheol;Kang Seong-Joon;Hong In-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.1
    • /
    • pp.61-69
    • /
    • 1998
  • Objectives: The response rate of the radioactive iodine(RI) therapy with low dose was variable. Only a few studies reported the response and complication rate with high dose. The goal of this study was to access the ablation and complication rate after high dose of RI therapy (more than 100mCi) and to evaluate the factors affect the results. Material and Methods: During a period of 12 years, 225 patients received high dose of RI from 100 to 200mCi depending on the RI uptake in the whole body after total thyroidectomy. 100mCi of RI was given to 123 patients for ablation who showed the uptake only in the thyroid bed. 150mCi was given to another 84 patients for ablation who had uptake confined to the neck. The other 21 patients took more than 200mCi of RI because the whole body scan showed distant metastasis. Among these patients, the ablation and the complication rate was investigated. Results: Elevated level of the serum thyroglobulin(Tg) decreased less than 5ng/ml after RI therapy in all patients except two in the first group. The second group showed reduction of the serum Tg in 93%. Eighteen of the 21 patients in the third group are still alive after RI therapy. There were no fatal complications after high dose RI therapy and most of the complications were minimal and transient. The complication rate was not related with the dose of RI, age, sex, DNA flowcytometry, serum thyroglobulin level and the extent of node dissection. Conclusion: We concluded that RI therapy with high dose was very effective for thyroid ablation after operation and it also showed excellent results with minimal complications for treatment of metastatic lesions.

  • PDF

Lobular Breast Carcinoma Metastasis to the Thyroid Gland: Case Report and Literature Review

  • Bourcier, Kevin;Fermeaux, Veronique;Leobon, Sophie;Deluche, Elise
    • Journal of Breast Cancer
    • /
    • v.21 no.4
    • /
    • pp.463-467
    • /
    • 2018
  • Metastasis from primary cancer to the thyroid is uncommon in breast cancer. Here we present a case of lobular breast carcinoma that metastasized to the thyroid. A 54-year-old woman without symptoms was admitted to our institution for staging of the lymph node above the left clavicle. An $^{18}F$-fluoro-deoxy-D-glucose positron emission tomography scan was performed for staging, and low uptakes were observed in the left supraclavicular and cervical lymph nodes. High uptake was seen in the posterior and lower left lobe of the thyroid. Histologic findings indicated lobular breast carcinoma (positive GATA3, loss of E-cadherin expression) metastatic to the thyroid with a luminal profile. Immunohistochemical analysis was negative for primary thyroid or parathyroid carcinoma. To our knowledge, this is the first report of a patient presenting a metastatic invasive lobular carcinoma in the thyroid and lymph nodes without a prior diagnosis of breast cancer.