• 제목/요약/키워드: Thyroid, aspiration biopsy

검색결과 67건 처리시간 0.031초

Degenerating Thyroid Nodules: Ultrasound Diagnosis, Clinical Significance, and Management

  • Jie Ren;Jung Hwan Baek;Sae Rom Chung;Young Jun Choi;Chan Kwon Jung;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • 제20권6호
    • /
    • pp.947-955
    • /
    • 2019
  • Degenerating nodules (DNs), which primarily manifest as benign thyroid nodules, are one of the main causes of discordance in ultrasonography (US) and cytological assessments. Intranodular hemorrhage is one of the mechanisms contributing to discordant nodules, and an impaired blood supply may explain further DN shrinkage and infarction. The surgical specimens can be divided into acute and chronic stages based on the histological changes, which usually mimic the US features of malignant tumors. Serial US follow-up should be recommended instead of other unnecessary procedures. However, repeated fine-needle aspiration, diagnostic surgery, or core-needle biopsy may still be necessary for indeterminable or highly suspicious DNs.

경부에 전이한 Sex Cord Tumor with Annular Tubules의 세침흡인 세포소견 - 1예 보고 - (Fine Needle Aspiration Cytologic Findings of Metastatic Sex Cord Tumor with Annular Tubules to the Neck - A Case Report -)

  • 오소영;강명재;정명자;문우성;이동근
    • 대한세포병리학회지
    • /
    • 제8권2호
    • /
    • pp.185-189
    • /
    • 1997
  • A sex cord tumor with annnular tubules is a relatively rare ovarian neoplasm. The cytologic findings from a fine needle aspiration biopsy of neck metastasis of a sex cord tumor with annnular tubules are described. The origin of the neck metastasis was the right ovary, and the tumor was diagnosed six years ago. The cytologic findings were characterized by tumor cells arranged in solid or follicular patterns. The tumor cells formed rosette-like or complex tubular structures with central rounded or coalesced hyaline materials. It was difficult to distinguish this tumor cytologically from granulosa cell tumor, thyroid follicular neoplasm, Sertoli-Leydig cell tumor, and Brenner tumor, but complex tubular structures were helpful in discriminating between these tumors.

  • PDF

The Usefulness of Immunocytochemistry of CD56 in Determining Malignancy from Indeterminate Thyroid Fine-Needle Aspiration Cytology

  • Cha, Hyunseo;Pyo, Ju Yeon;Hong, Soon Won
    • 대한병리학회지
    • /
    • 제52권6호
    • /
    • pp.404-410
    • /
    • 2018
  • Background: Fine-needle aspiration cytology serves as a safe, economical tool in evaluating thyroid nodules. However, about 30% of the samples are categorized as indeterminate. Hence, many immunocytochemistry markers have been studied, but there has not been a single outstanding marker. We studied the efficacy of CD56 with human bone marrow endothelial cell marker-1 (HBME-1) in diagnosis in the Bethesda System for Reporting Thyroid Cytopathology (TBSRTC) category III. Methods: We reviewed ThinPrep liquid-based cytology (LBC) samples with Papanicolaou stain from July 1 to December 31, 2016 (2,195 cases) and selected TBSRTC category III cases (n=363). Twenty-six cases were histologically confirmed as benign (six cases, 23%) or malignant (20 cases, 77%); we stained 26 LBC slides with HBME-1 and CD56 through the cell transfer method. For evaluation of reactivity of immunocytochemistry, we chose atypical follicular cell clusters. Results: CD56 was not reactive in 18 of 20 cases (90%) of malignant nodules and showed cytoplasmic positivity in five of six cases (83%) of benign nodules. CD56 showed high sensitivity (90.0%) and relatively low specificity (83.3%) in detecting malignancy (p=.004). HBME-1 was reactive in 17 of 20 cases (85%) of malignant nodules and was not reactive in five of six cases (83%) of benign nodules. HBME-1 showed slightly lower sensitivity (85.0%) than CD56. The specificity in detecting malignancy by HBME-1 was similar to that of CD56 (83.3%, p=.008). CD56 and HBME-1 tests combined showed lower sensitivity (75.0% vs 90%) and higher specificity (93.8% vs 83.3%) in detecting malignancy compared to using CD56 alone. Conclusions: Using CD56 alone showed relatively low specificity despite high sensitivity for detecting malignancy. Combining CD56 with HBME-1 could increase the specificity. Thus, we suggest that CD56 could be a useful preoperative marker for differential diagnosis of TBSRTC category III samples.

BRAFV600E Mutation Analysis in Fine Needle Aspiration Biopsy Cytology and Formalin Fixed Paraffin Embedding Block of the Thyroid

  • Han, Kyung Hee;Park, Won Young;Lee, Young Nam
    • 대한임상검사과학회지
    • /
    • 제45권2호
    • /
    • pp.66-72
    • /
    • 2013
  • Fine Needle Aspiration Biopsy Cytology (FNABC), which is known as the most accurate and cost-effective method for diagnosis of the thyroid nodule, may still result in indeterminate cases that are cellular paucity and show minor nuclear atypia. However, most cases are associated with suspicion of papillary thyroid carcinoma (PTC). A B-type Raf kinase (BRAF) mutation was found in about half of PTCs which is currently helping us to differentiate malignancies from benign lesions. Cases studied included 46 histological, confirmed PTC cases. FNABC 102 cell paucity and 74 atypia benign cases were previously diagnosed as suspicious of PTC using cytologic examination. These cases were analyzed for BRAF mutation by polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) with a new restriction enzyme. In this study, the sensitivity and specificity were calculated and, BRAF mutation was detected by means of a histological method in 23 of 46 cases of PTC and no mutation was found in 22 cases. However, one case was not detected. In using FNABC, BRAF mutation was detected in 6 of 102 cases in cell paucity and in 11 of 74 cases in the atypia. Two cases were not detected in the atypia. The sensitivity and specificity of PCR-RFLP in FNABC were 60% and 97.4% respectively. Assessment of Formalin Fixed Paraffin Embedding (FFPE) block demonstrated similarly a 51.1% positive and 48.9% negative in PTC. Evaluation of BRAF mutation revealed high specificity and low sensitivity in using FNABC method. This study suggests that BRAF mutation analysis should be useful for the clinical diagnosis of PTC in FNABC with cytological findings suspicious for PTC.

  • PDF

Diagnostic Performance of Core Needle Biopsy for Characterizing Thyroidectomy Bed Lesions

  • So Yeong Jeong;Jung Hwan Baek;Sae Rom Chung;Young Jun Choi;Dong Eun Song;Ki-Wook Chung;Won Woong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • 제23권10호
    • /
    • pp.1019-1027
    • /
    • 2022
  • Objective: Thyroidectomy bed lesions frequently show suspicious ultrasound (US) features after thyroid surgery. Fine-needle aspiration (FNA) may not provide definitive pathological information about the lesions. Although core-needle biopsy (CNB) has excellent diagnostic performance in characterizing suspicious thyroid nodules, no published studies have evaluated the performance of CNB specifically for thyroidectomy bed lesions. Therefore, we aimed to evaluate the diagnostic performance and safety of CNB for characterizing thyroidectomy bed lesions. Materials and Methods: A total of 124 thyroidectomy bed lesions in 113 patients (79 female and 34 male; age, 23-85 years) who underwent US-guided CNB between December 2008 and December 2020 were included. We reviewed the US imaging features of the target lesions and the histories of previous biopsies. The pathologic results, diagnostic performance for malignancy, and complications of CNB were analyzed. Results: All samples (100%) obtained by CNB were adequate for pathological analysis. Pathological analysis revealed inconclusive results in two lesions (1.6%). According to the reference standard, 50 lesions were ultimately malignant (40.3%), and 72 were benign (58.1%), excluding the two inconclusive lesions. The performance of CNB for diagnosing malignant thyroidectomy bed lesions in the 122 lesions had a sensitivity of 98.0% (49/50), a specificity of 100% (72/72), positive predictive value of 100% (49/49), and negative predictive value of 98.6% (72/73). Eleven lesions were referred for CNB after prior inconclusive FNA results in thyroidectomy bed lesions, for all of which CNB yielded correct conclusive pathologic diagnoses. According to the pathological analysis of CNB, there were various benign lesions (58.9%, 73/124) besides recurrence, including benign postoperative lesions other than suture granuloma (32.3%, 40/124), suture granuloma (15.3%, 19/124), remnant thyroid tissue (5.6%, 7/124), parathyroid lesions (4%, 5/124), and abscesses (1.6%, 2/124). No major or minor complications were associated with the CNB procedure. Conclusion: US-guided CNB is accurate and safe for characterizing thyroidectomy bed lesions.

갑상샘 유두암과 혼재하여 발견된 편평세포암 1예 (A Case of Mixed Papillary Thyroid Tumor and Squamous-Cell Carcinoma)

  • 김호수;정태식;정정화;김수경;이상민;정순일;함종렬
    • Journal of Yeungnam Medical Science
    • /
    • 제28권2호
    • /
    • pp.206-210
    • /
    • 2011
  • The occurrence of a mixed tumor containing papillary thyroid carcinoma (PTC) and primary squamous-cell carcinoma (SCC) is rare because there is no squamous epithelium in the thyroid gland. Reported herein is a 30-year-old female with mixed PTC and primary sec of the thyroid presented as thyroid incidentaloma. Fine-needle aspiration biopsy of the thyroid nodule revealed the presence of malignant thyroid cells. The histopathological examination following total thyroidectomy yielded two mixed, morphologically distinct histotypes that included PTC and sec. After total thyroidectomy, the patient underwent radioactive iodine therapy. No recurrence or metastasis occurred during the 20-month follow-up period after the operation.

  • PDF

Technical Report: A Cost-Effective, Easily Available Tofu Model for Training Residents in Ultrasound-Guided Fine Needle Thyroid Nodule Targeting Punctures

  • Yun-Fei Zhang;Hong Li;Xue-Mei Wang
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.166-170
    • /
    • 2019
  • Objective: To establish a cost-effective and easily available phantom for training residents in ultrasound-guided fine needle thyroid nodule targeting punctures. Materials and Methods: Tofu, drinking straws filled with coupling gel, a urine tube, and 21-gauge needles were used to generate a phantom thyroid with nodules for training. Twelve radiology residents were involved in the study. The puncture success rates were recorded and compared before and after phantom training using the Wilcoxon signed-rank test. Results: On ultrasonography, tofu mimicked the texture of the thyroid. Drinking straws filled with coupling gel mimicked vessels. The urine tube filled with air mimicked the trachea, and 21-gauge needles mimicked small nodules in the transverse section. The entire phantom was similar to the structure of the thyroid and surrounding tissues. The puncture success rates of radiology residents were significantly increased from 34.4 ± 14.2% to 66.7 ± 19.5% after training (p = 0.003). The phantom was constructed in approximately 10 minutes and materials cost less than CNY 10 (approximately $ 1.5) at a local store. Conclusion: The tofu model was cost-effective, easily attainable, and effective for training residents in ultrasound-guided fine needle thyroid nodule targeting punctures in vitro.

Surgical Perspective of T1799A BRAF Mutation Diagnostic Value in Papillary Thyroid Carcinoma

  • Brahma, Bayu;Yulian, Erwin Danil;Ramli, Muchlis;Setianingsih, Iswari;Gautama, Walta;Brahma, Putri;Sastroasmoro, Sudigdo;Harimurti, Kuntjoro
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권1호
    • /
    • pp.31-37
    • /
    • 2013
  • Background: Throughout Indonesia, thyroid cancer is one of the ten commonest malignancies, with papillary thyroid carcinoma (PTC) in our hospital accounting for about 60% of all thyroid nodules. Although fine needle aspiration biopsy (FNAB) is the most reliable diagnostic tool, some nodules are diagnosed as indeterminate and second surgery is common for PTC. The aim of this study was to establish the diagnostic value and feasibility of testing the BRAF T1799A mutation on FNA specimens for improving PTC diagnosis. Materials and Methods: This prospective study enrolled 95 patients with thyroid nodules and future surgery planned. Results of mutational status were compared with surgical pathology diagnosis. Results: Of the 70 cases included in the final analysis, 62.8% were PTC and the prevalence of BRAF mutation was 38.6%. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for BRAF mutation analysis were 36%, 100%, 100% and 48%, respectively. With other data findings, nodules with "onset less than 5 year" and "hard consistency" were proven as diagnostic determinants for BRAF mutation with a probability of 62.5%. This mutation was also a significant risk factor for extra-capsular extension. Conclusions: Molecular analysis of the BRAF T1799A mutation in FNAB specimens has high specificity and positive predictive value for PTC. It could be used in the selective patients with clinical characteristics to facilitate PTC diagnosis and for guidance regarding extent of thyroidectomy.

갑상선암의 경부 림프절 전이 진단을 위한 미세침세척액 티로글로불린 측정법 (Thyroglobulin Measurement in Fine Needle Aspirates for Diagnosing Cervical Lymphnode Metastasis from Differentiated Thyroid Malignancy)

  • 고희영;김승수;이춘호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.181-185
    • /
    • 2010
  • 갑상선암 환자의 경부 림프절에서 미세침흡인생검술(fine needle aspiration biopsy, FNAB)을 시행하며 얻은 미세침세척액의 티로글로불린(thyroglobulin, Tg)측정법의 진단적 성적과 유용성을 알아보고자 FNAB 세포검사의 결과와 비교하였다. 갑상선암의 경부림프절 전이가 의심되어 초음파 시행한 총 37명의 환자 48개의 FNAB 검체를 대상으로 하였고, 수술 후 조직검사결과 또는 장기간 영상 추적검사를 기준으로 하여 세포검사와 미세침세척액 티로글로불린(FNAB-Tg)측정법을 비교하여, 각 검사의 특이도, 민감도 및 정확도를 평가하였다. 추가적으로 Tg-항체가 양성일때 FNAB-Tg 검사에는 어떠한 영향을 미치는지 Tg-항체 검사를 같이 시행한 34명을 대상으로 분석하여 보았다. FNAB 검체의 세포검사에서 전이 음성인 36개 검체 중 35개 검체에서 음성을 보였고, 전이 양성인 12개 검체 중 9개 검체에서 양성을 보였다. FNAB-Tg측정법의 경우 전이 음성인 36개의 검체 중 32개의 검체에서 음성을 보였고, 전이 양성인 12개의 검체 중 12개 검체 모두 양성을 보였다. 따라서 세포검사의 민감도와 특이도는 각각 75.0% (9/12)와 97.2% (35/36)였고, 위음성이 25% (3/12)였다. 반면에 FNAB-Tg 측정법의 민감도와 특이도는 각각 100% (12/12)와 88.9% (32/36)였고, 위양성이 11.1% (4/36)였다. 정확도는 두 검사 모두 91.7% (44/48)였다. Tg-항체에 대한 검사 결과를 얻을 수 있는 34명을 따로 분석한 결과, Tg-항체의 존재 유무가 FNAB-Tg 측정법의 진단 성능에 영향을 주지 않음을 확인할 수 있었다. FNAB 검체를 이용한 세포검사는 특이도가 높고 반면, FNAB-Tg 측정법은 민감도가 높은 검사임을 확인할 수 있었다. 따라서 림프절 전이가 의심되는 갑상선환자에서 FNAB를 시행할 때 세포검사와 FNAB-Tg 측정법은 동시에 시행되어야 할 상호보완적인 검사들이다.

  • PDF

Diagnostic value of Thyroglobulin Measurement with Fine-needle Aspiration Biopsy for Lymph Node Metastases in Patients with a History of Differentiated Thyroid Cancer

  • Zhang, Hai-Shan;Wang, Ren-Jie;Fu, Qing-Feng;Gao, Shi;Sun, Bu-Tong;Sun, Hui;Ma, Qing-Jie
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권24호
    • /
    • pp.10905-10909
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the diagnostic value of FNA-Tg for detecting lymph node metastases in patients with a history of differentiated thyroid cancer (DTC). Materials and Methods: A total of 58 patients with DTC diagnosis and evidence of single or multiple suspicious cervical lymph nodes were assessed. All underwent total or near-total thyroidectomy with (35 cases) or without (23 cases) radioiodine (RAI) ablation, followed by thyroid stimulating hormone (TSH) suppression therapy. A total of 68 lymph nodes were examined by ultrasound-guided fine needle aspiration (US-FNA) for both cytological examination and FNA-Tg measurement. Serum Tg and anti-thyroglobulin antibody (TgAb) levels were also measured. Diagnostic performance including sensitivity, specificity, accuracy, positive (PPV) and negative predictive value (NPV) of FNAC and FNA-Tg were calculated and compared. The Spearman's rank correlation coefficient was used to estimate the relationship between FNA-Tg and serum TgAb. Results: The FNA-Tg levels were significantly higher with DTC metastatic lymph nodes (median 927.7 ng/mL, interquartile range 602.9 ng/mL) than non-metastatic lymph nodes (median 0.1 ng/mL, interquartile range 0.4 ng/mL) (p<0.01). Considering 1.0 ng/mL as a threshold value for FNA-Tg, the sensitivity, specificity, accuracy, PPV and NPV of FNA-Tg were 95.7%, 95.5%, 95.6%, 97.8% and 91.3%, respectively. The sensitivity and accuracy of the combination of FNAC and FNA-Tg were significantly higher than that of FNAC alone (p<0.05). The diagnostic performance of FNA-Tg was not significantly different between cases with or without RAI ablation, and the serum TgAb levels did not interfere with FNA-Tg measurements. Conclusions: Measurement of FNA-Tg is useful. The combination of FNAC and FNA-Tg is more sensitive and accurate for detecting lymph node metastases in patients with a history of DTC than FNAC alone. Serum TgAbs appear to be irrelevant for measurement of FNA-Tg.