Analysis on the Effects of TRV and MOV in Real System with TCSC (TCSC가 적용된 실계통 시스템에서의 TRV와 MOV의 영향에 대한 분석)

  • Lee, Seok-Ju
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.41-46
    • /
    • 2019
  • The application of series compensator in a power system affects other devices such as circuit breakers transient recovery voltage (TRV) problem. In this paper, we analyze the TRV effect on a line circuit breaker in the cases with and without thyristor-controlled series capacitor (TCSC) via simulation, and suggest an effective method to overcome the increase of TRV due to the TCSC installation. It also discusses the impact of proposed protection on metal oxide varistor (MOV). A 345 kV transmission line in Korea was selected as a study case. Grid system was modelled using PSCAD (Power Systems Computer Aided Design) / EMTDC(Electro Magnetic Transient Direct Current). The TRV was analyzed by implementing a short circuit fault along the transmission line and at the breaker terminal. The proposed protection scheme, the TRV satisfies the standard. However, the MOV energy capacity increased as the delay time increased. This result can solve the TRV problem caused by the expected transmission line fault in a practical power system.

Surge current endurance evaluation of Thyristor (사이리스터(Thyristor)의 서지(Surge) 전류 내력 평가에 관한 연구)

  • Jeong, Jong-Kyou;Seo, Dong-Woo;Jung, Hong-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.253-254
    • /
    • 2020
  • High Voltage Direct Current (HVDC) 시스템은 고압 직류송전을 위한 시스템이다. 고압 직류 송전을 위해서는 전력변환기가 교류전력을 직류전력으로 변환해주어야 하는데, 최근에는 모듈형 멀티레벨 컨버터(Modular Multilevel Converter, MMC)가 많이 적용되고 있다. MMC는 다수의 서브모듈이 직렬로 구성되어 있으며 DC-link단에 대용량 커패시터가 없다. MMC의 심각한 사고 중에 하나는 DC측 전력케이블의 단락사고로 시스템에 따라서 수십 kA 정도의 사고전류가 AC측 CB(Circuit Breaker)가 열리기 전까지 수십 ms에서 수백 ms동안 흐른다. 만약 하프브릿지 회로의 서브모듈로 구성된 컨버터에 별도 보호장치가 없으면 단락전류는 서브모듈의 하단 다이오드를 통해서 흐르게 되어 소손되게 된다. 이를 방지하기 위해 단락전류를 바이패스(by-pass) 시키기 위한 별도의 사이리스터를 추가하는데 이 기기의 사양은 DC 단락 전류를 충분히 견딜 수 있어야 한다. 본 논문에서는 사이리스터의 서지 전류 내력을 평가하기 위해 사양을 분석하고 시뮬레이션과 실험을 통해서 검증하였다.

  • PDF

Contactless DC Circuit Breakers Using MOS-controlled Thyristors (전력용 사이리스터 MCT를 이용한 무접점 직류차단기)

  • Sim, D.Y.;Kim, C.D.;Nho, E.C.;Kim, I.D.;Kim, Y.H.;Jang, Y.S.
    • Journal of Power System Engineering
    • /
    • v.4 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • Circuit breakers have traditionally employed mechanical methods to interrupt excessive currents. According to power semiconductor technology advances in power electronic device, some mechanical breakers are replaced with solid state equivalents. Advantages of the contactors using semiconductor devices include faster fault interrupting, fault current limiting, no arc to contain or extinguish and intelligent power control, and high reliability. This paper describes the design of a static $100{\pm}10%V$ and 0 to 50A DC self-protected contactor with 85A "magnetic tripping" and 100A interruption current at $2.2A/{\mu}s$ short circuit of load condition using a new power device the HARRIS MCT (600V-75A). The self-protection circuit of this system is designed by the classical ZnO varistor for energy absorption and turn-off snubber circuit ("C" or "RCD") of the MCT.

  • PDF

Test results of small scale changeover system using in neutral section for AC feeding system (축소형 교류급전시스템 절연구간 자동절체장치 성능시험)

  • Jang, Dong-Uk;Han, Moon-Seob
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.948-953
    • /
    • 2011
  • In AC railway feeding system, three phase received from the network is changed to two phase power sources with different phases. The main circuit breaker installed train is automatically open by track signal when the train passes the neutral section. In order to continuously supply power source to train, the changeover system was used in Japan. Therefore, the train is able to operate under powering condition when it was passing through the neutral section. We investigated the control method to reduce the inrush current flowing main transformer in train. To examine the inrush current and operate the static semiconductor switch such as thyristor, we manufactured the small scale the changeover system and carried out performance tests.

  • PDF