• Title/Summary/Keyword: Thyristor AC/DC converter

Search Result 16, Processing Time 0.028 seconds

Algorithm Development for Improving Output Characteristics of Thyristor Dual Converter with AC Input Voltage Variation (교류 입력 전압 변동에 따른 사이리스터 듀얼 컨버터의 출력 특성 개선을 위한 알고리즘 개발)

  • Kim, Sung-An;Han, Sung-Woo;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1437-1443
    • /
    • 2017
  • Electric energy is consumed or regenerated according to an operation of electric rail cars in urban railway power substations. A thyristor dual converter system is used to deal with the electric energy. Since the AC input voltage of power substations is $22.9kV{\pm}10%$, the magnitude of the AC voltage fluctuates according to load conditions, so the secondary side voltage of the DDY transformer also fluctuates. In the thyristor dual converter, the response characteristics of the DC output voltage and the DC output current are changed based on an initial firing angle in the cross mode conversion between the forward mode and the reverse mode. Therefore, this paper proposes the initial firing angle tracking algorithm considering fluctuation of the AC input voltage. The effectiveness of the proposed algorithm is verified by a simulation compared with the conventional algorithm.

PROTECTION SEQUENCE OF AC/DC CONVERTERS FOR ITER PF MAGNET COILS

  • Oh, Byung-Hoon;Hwang, Churl-Kew;Lee, Kwang-Wang;Jin, Jeong-Tae;Chang, Dae-Sik;Oh, Jong-Seok;Choi, Jung-Wan;Suh, Jae-Hak;Tao, Jun;Song, In-Ho
    • Nuclear Engineering and Technology
    • /
    • v.42 no.3
    • /
    • pp.305-312
    • /
    • 2010
  • The protection sequence of an AC/DC converter for an ITER PF coil system is developed in this study. Possible faults in the coil system are simulated and the results reflected in the design of a sequence to protect the coil and converter. The inductances of the current sharing reactors and thyristor numbers in parallel with the bridge arms are optimized with the designed protection sequence.

KO AC/DC Converter System Installation Status and Commissioning Plan at ITER Site (이터 초전도자석 전원공급장치 현장 설치현황 및 시운전 계획)

  • Song, Inho;Oh, Jong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.397-401
    • /
    • 2022
  • The construction of the ITER tokamak machine is ongoing at a 77% process rate to achieve the first plasma in 2025. The 18 sets of power supply systems comprising 400 MVA thyristor AC/DC converters for the superconducting magnets supplied by Korea (KO) are being installed with other systems, such as PF converters (China), DC busbars (Russia), and cooling water systems (India), in two buildings (Europe). The system interfaces have been defined during the design stage, and the systems have been manufactured. However, during the on-site installation work, several installation and integration issues emerged due to the manufacturing tolerance and design mistakes. To continue the installation and testing, the engineers of each system resolved the interface issues, planned the commissioning, and integrated the test plan. This paper describes the on-site installation status and issues and the commissioning plan of KO AC/DC converters.

Thyristor전력변환기-전동기계의 무효전력의 처리에 관한 연구

  • 유철로
    • 전기의세계
    • /
    • v.31 no.1
    • /
    • pp.50-58
    • /
    • 1982
  • As a method for improving the power factor and the waveform of ac line current drawn by ac to dc converters, converters of pulse-width control type with forced commutation circuits have been developed in recent years. However, these converters have rather complex commutation circuits which contain auxiliary thyristors in addition to the main thyristors, and their performance is not satisfactory. This paper proposes a new pulse-width controlled ac to dc converter, and analyses its commutation mechanism and its input and output characteristics. The proposed converter circuit consists of a usual thyristor bridge circuit with series diodes to which reactors and diodes are added. This circuit dose not contain auxiliary thyristors, and in this sense it is simpler than the previous converter circuits of pulse-width control type. Since the main thyristors of the converter can be forcedly turned off several times in a half cycle of source voltage, a pulse-width modulation control is possible in order to improve the current waveform as well as the power factor on ac line side. As to dc output side it is shown that the adjustable range of output voltage is wide and the voltage regulation is good due to a rapid reversal of voltage across the commutating capacitors by LC resonance during commutation period. It is also shown that the regenerative operation of the converter is possible.

  • PDF

Fine output voltage control of a phase-controlled converter (위상정류제어기의 정밀출력제어)

  • Kang, Y.;You, D.;Baek, J.;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.240-242
    • /
    • 1994
  • Diode and thyristor-based bridge converter have been used for ac/dc conversion. Comparatively, diode bridges are simpler, more robust, less expensive and have a better power factor. However when voltage regulation is required, the thyristor-based phase-controlled converter have been used. But their use is limited by the low power factor and considerable harmonics in the input and output. An ac/dc power conversion scheme capable of fine output voltage control is investigated in this paper.

  • PDF

Diode-Bridge Type Three Phase Six Pulse Dual Converter (다이오드 브릿지 방식에 의한 3상 6펄스 튜엘 콘버어터에 관한 연구)

  • 김철우;윤병도
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.3
    • /
    • pp.179-187
    • /
    • 1987
  • Dual converter using diode bridge and 6-thyristor is discussed and the characteristics of this converter depending on their switching mode is revealed. The switching modes of converter operation are identified on both ac and dc sides. The circuit has the ability to accept or deliver DC current without change of nominal DC voltage magnitude or polarity and has the capability not only to instantaneously change from motoring to generating and vice versa, but to operate cycloconverter.

  • PDF

A Single-Phase PWM Converter with fast response (빠른 응답성을 갖는 단상 PWM Converter)

  • 배기훈;기상우;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.322-327
    • /
    • 1999
  • In most railway vehicle applications, a single phase AC/DC converter is used greatly and is essential equipment for Korea High Speed Train. A diode bridge rectifier and a phase-controlled thyristor bridge rectifier generate harmonics in power system. Nowadays, power factor and harmonics become major issue in electrical equipment for railway vehicle. Many researchers have been trying to improve the power factor and ac-side harmonics. Therefore the PWM converter is used to operate at unity Power factor and to reduce ac-side current harmonics. This paper describes the circuit for AC/DC PWM converter of Korea High Speed Train and proposes control algorithm to realize the sinusolidal input current waveform and the effective unity power factor. The validity of the proposed control method is verified through the experimental result.

  • PDF

A Study on Design of Controller Gain for PWM Converter (PWM 컨버터 제어기 이득의 해석적 설계)

  • Gho J.S.;Cho J.S.;Kang B.H.;Choe G.H.;Kwak C.H.;Chung S.E.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.491-495
    • /
    • 2001
  • Compare with diode or thyristor bridge AC/DC converter, the 3 phase PWM converter has some merits of low THD and unit power factor. So, in many critical application like as UPS, using PWM converter is the trends. 3 phase PWM converter had been studied widely already. But analytical design procedure can not found from publication for hardware design and controller design. So, in this paper, 3 phase PWM converter analysis review was given. And from the DC analysis result, parameter design was done. From the AC model, the voltage controller and current controller was designed. The gain of controllers was calculated by analytical method.

  • PDF

Analysis of HVDC Converter Commutation Process (HVDC 전력변환기의 Commutation 동작분석)

  • Kwak, J.S.;Wook, W.J.;Koh, B.E.;Kim, C.K.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1286-1288
    • /
    • 2000
  • Commutation failure can be considered as the severest abnormal operation of thyristor HVDC converter. During the failure, power conversion from DC to AC is stopped until the AC voltage get recovered. The process of thyristor converter is subscribed at normal and abnormal state, respectively. The detection and the protection for Cheju HVDC are explained by computer simulation results.

  • PDF

A Study on the Development of the Charging-Discharging System with High Power Factor and High Efficiency (고역율, 고효율 충.방전기 개발에 관한 연구)

  • Kim, Eun-Soo;Joe, Kee-Yeon;Byun, Young-Bok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.568-572
    • /
    • 1994
  • This paper presents equipment for charging and discharging with high power factor aid high efficiency. This equipment is consisted of $3{\phi}$SPWM AC/DC converter for improving input current waveform and input power factor, and bidirectional DC/DC converter for electric isolation in the DC link Part. Therefore, Input power factor and the total efficiency in the proposed system can be increased more than in the conventional phase-controlled thyristor Charging - Discharging System.

  • PDF