• 제목/요약/키워드: Through-transmission measurement

검색결과 319건 처리시간 0.037초

Two-Terminal Numerical Algorithm for Single-Phase Arcing Fault Detection and Fault Location Estimation Based on the Spectral Information

  • Kim, Hyun-Houng;Lee, Chan-Joo;Park, Jong-Bae;Shin, Joong-Rin;Jeong, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.460-467
    • /
    • 2008
  • This paper presents a new numerical algorithm for the fault location estimation and arcing fault detection when a single-phase arcing ground fault occurs on a transmission line. The proposed algorithm derived in the spectrum domain is based on the synchronized voltage and current samples measured from the PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. In this paper, the algorithm uses DFT(Discrete Fourier Transform) for estimation. The algorithm uses a short data window for real-time transmission line protection. Also, from the calculated arc voltage amplitude, a decision can be made whether the fault is permanent or transient. The proposed algorithm is tested through computer simulation to show its effectiveness.

공중 전화회선용 다중 채널 ECG데이터 원격 측정시스템 설계 (A Design of Multi-Channel Biotelemetry for ECG Encoding and Transmission Over the Public Telephone Line)

  • 계신웅;장원석;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권1호
    • /
    • pp.21-34
    • /
    • 1986
  • In this paper, we described the ECG telemetry system via the Public Telephone Line. The system consist of a signal acquisition and measurement section, a signal processing section, and a signal transmission section. It used 8 bits microprocessor. The transmission section is composed of 3 ch. analog modulators and 1 ct. digital modem. Especially, using the digital modem, signal is transmitted with about 50n data reduction ratio by the TP (Turning Point) algorithm. The acoustic coupler or inductive coil for linking the public telephone line are used. The speed of the digital modem is 300 baud rate. The MCBS (Multi Channel Biotelemetry System) is tested and evaluated through the experiment.

  • PDF

Development of a Live-line Insulator Inspection Tool System for 154 kV Power Transmission Lines

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak;Oh, Ki-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.23-33
    • /
    • 2012
  • The current paper deals with a new live-line insulator inspection tool system that will be used by the Korea Electric Power Corporation for its 154 kV power transmission lines in 2011. Unlike the existing contact type tools, the developed inspection tool automates parts of the insulator inspection process using a sensor and an actuator. The tool sustains its weight independently, not by a lineman. In addition, the inspection tool measures the insulation resistance of an insulator together with its distribution voltage, thus providing more information for analysis and diagnosis. Such characteristics improve the system's operation efficiency, measurement reliability, and usability. We confirmed its effectiveness through live-line field tests with actual power transmission lines.

실린더 페라이트 코어를 사용한 무접점 전력 변환 시스템 (A Contactless Power Conversion System Use a Slinder Ferrite Core)

  • 이승준;안재우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.638-641
    • /
    • 2001
  • Connectorless power transmission and supply are the power transfer device revealed by resonant inverter or transformer using inductant device. Recently, on power supply have been going on frequently, so several power supply circuit forms are announced. But Compared with the circuit of previous paper, instead of the circuit composed of a simple sylinder Ferrit, I was manufacture in a sylinder that It was a double overlab to a sylinder and I was followed a double flux in inner flux path. Above all, for practicalization, supply circuit operation character analysis and development of controller should be preceded. According to this paper, power transmission and supply analyze characters and design control circuit like the analysis of general resonant inverter for power transmission. They compose the circuit to get sinusoid wave output voltage using pulse width modulation control mode. For Supply, output wave form through power track and power pick-up of magnetic inductance includes ripper component. So I intend to design the controller including filter and regulator, compare analyze theoretical result with real measurement value and then show you their practicality

  • PDF

2차원 구조물의 진동 인텐시티 계측에 대한 연구 (A Study on Structural Intensity Measurement of 2-dimensional Structure)

  • 이덕영;박성태
    • 소음진동
    • /
    • 제7권3호
    • /
    • pp.477-488
    • /
    • 1997
  • In order to control vibration in structures, it is desirable to be able to identify dominant paths of vibration transmission from sources through the structure to some points of interest. Structural intensity vector(power flow per width of cross section) using cross spectra is able to measure the vibration power flow at a point in a structure. This paper describes the structural intensity measurement of 2-dimensional structure. Structural intensity of 2-dimensional structure can be obtained from eight point cross spectral measurement per axis, or two point measurement per axis on the assumption of far field. Approximate formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained on an infinite plate at the near and far field in flexural vibration. The measurement error of two point measurement is rather bigger than eight point measurement on account of the assumption that Poisson's ratio is 1. The structural intensity vectors on the plate are checked the ability to identify the path of vibration power flow in random excitation and 200Hz sine excitation, the result of two point measurememt is almost the same as the result of eight point measurement in 200Hz sine excitation.

  • PDF

건축설비 기계실의 벽체 투과손실에 관한 실험적 연구 (Experimental Study on Wall Sound Transmission Loss at Construction Equipment Machinery Room)

  • 국정훈;정철운;윤재현;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.701-705
    • /
    • 2007
  • The equipment noise of machine room that generates at the building where human-being is living, is becoming to an object of strong civil appeal, and because it influences to the residential space through the floor or wall, its damage is very serious level. Accordingly, while an efficient forming of the sound insulating measures is earnest, as most of the transmission loss data was the material measured in laboratory, in case when it was applied to the job site, due to the precision difference of constructing work and the influence of detoured transmitting sound, the case of disaccord is the most. Therefore, this thesis has intended to present a fundamental data for an efficient establishment of sound insulation measure, by means of comparison analysis with the existing transmission loss data, after measurement of the transmission loss on the object of various walls, at the construction equipment machinery room.

  • PDF

Performance Evaluation of a Driving Power Transmission System for 50 kW Narrow Tractors

  • Hong, Soon-Jung;Ha, Jong-Kyou;Kim, Yong-Joo;Kabir, Md. Shaha Nur;Seo, Young Woo;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • 제43권1호
    • /
    • pp.1-13
    • /
    • 2018
  • Purpose: The development of compact tractors that can be used in dry fields, greenhouses, and orchards for pest control, weeding, transportation, and harvesting is necessary. The development and performance evaluation of power transmission units are very important when it comes to tractor development. This study evaluates the performance of a driving power transmission unit of a 50 kW multi-purpose narrow tractor. Methods: The performance of the transmission and forward-reverse clutch, which are the main components of the driving power transmission unit of multi-purpose narrow tractors, was evaluated herein. The transmission performance was evaluated in terms of power transmission efficiency, noise, and axle load, while the forward-reverse clutch performance was evaluated in terms of durability. The transmission's power transmission efficiency accounts for the measurement of transmission losses, which occur in the transmission's gear, bearing, and oil seal. The motor's power was input in the transmission's input shaft. The rotational speed and torque were measured in the final output shaft. The noise was measured at each speed level after installing a microphone on the left, right, and upper sides. The axle load test was performed through a continuous equilibrium load test, in which a constant load was continuously applied. The forward-reverse clutch performance was calculated using the engine torque to axle torque ratio with the assembled engine and transmission. Results: The loss of power in the transmission efficiency test of the driving power unit was 6.0-9.7 kW based on all gear steps. This loss of horsepower was equal to 11-18% of the input power (52 kW). The transmission efficiency of the driving power unit was 81.5-89.0%. The noise of the driving power unit was 50-57 dB at 800 rpm, 70-77 dB at 1600 rpm, and 76-83 dB at 2400 rpm. The axle load test verified that the input torque and axle revolutions were constant. The results of the forward-reverse clutch performance test revealed that hydraulic pressure and torque changes were stably maintained when moving forward or backward, and its operation met the hydraulic design standards. Conclusions: When comprehensively examined, these research results were similar to the main driving power transmission systems from USA and Japan in terms of performance. Based on these results, tractor prototypes are expected to be created and supplied to farmhouses after going through sufficient in-situ adaptability tests.

함정의 해수 배관소음 저감을 위한 흡음형 소음기 연구 (A Study on the Absorptive Silencer for Reducing Noise Propagate in Seawater Pipes on Ship)

  • 서영수;박경훈;전재진
    • 한국소음진동공학회논문집
    • /
    • 제23권8호
    • /
    • pp.770-776
    • /
    • 2013
  • Fluid-borne noise produced by seawater circulating pumps propagates through the seawater connected pipes and radiates from the hull opening of a ship. This noise causes the increases of underwater radiated noise and self noise of ship. To reduce the noise propagation through the seawater connected pipes, absorptive silencer must be needed. In this paper, theoretical model to analyze the transmission loss of absorptive silencer was presented and the design parameters of absorptive silencer were verified. Theoretical calculations were performed according to a thickness, a length, an internal pressure and mechanical properties of its absorptive material in order to analyze the characteristics of absorptive silencer. From the theoretical calculation results, the absorptive silencer was manufactured and transmission loss was measured in the test facilities. The results of theory and measurement are compared and discussed.

Fast Measurement using Wave-Cutoff Method

  • 서상훈;나병근;유광호;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

Irradiance Distribution in East Sea by Using Measured Optical Properties for Squid Jigging Vessels

  • Bae, JaeHyun;Kim, SangWoo;Park, TaeYang;Cho, HyunWoo;An, YoungDuk;Kim, SangHyun;Ra, HyunWoon;Cho, YoungSil;Koh, JaeSeok;Jung, MeeSuk
    • Journal of the Optical Society of Korea
    • /
    • 제20권5호
    • /
    • pp.547-556
    • /
    • 2016
  • A fishing lamp is the instrument for attracting distributed fish to a certain place, and is the lighting system mainly used in fishery. In the inshore fishing, most fishing lamps are used for squid and hairtail jigging fishing, and the light source of the fishing lamps mainly used is metal halide with 1.5 KW in electric power consumption. We will analyze the irradiance distribution according to depth because squid is attracted towards light. To analyze irradiance distribution by such fishing lamps, data for seawater Type-II among the seawater types defined in 1976 are applied to East Sea. However, the Type-II data have limitations in analyzing precise seawater transmission characteristics, due to insufficient information on deep seawater. This paper analyzed the irradiance distribution of fishing lamps using the measurement of transmission characteristics in the seawater in East Sea up to 100 m underwater instead of Type-II data, which is not sufficient for transmission. A compensation factor was drawn between the actual measurement data and Type-II data through seawater transmission characteristics simulation.