• Title/Summary/Keyword: Thrombus

Search Result 344, Processing Time 0.023 seconds

Quantitative Assessment of Coronary Artery Diameter in Patients with Atrial Fibrillation and Normal Sinus Rhythm (심방세동 환자와 정상 심전도 환자의 관상동맥 직경 정량적 평가)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.567-574
    • /
    • 2022
  • Coronary artery disease (CAD) and atrial fibrillation (AF) are known to share many risk factors. In particular, in the case of acute coronary syndrome, it may be difficult to clearly determine the diameter of the vessel due to complete occlusion of the vessel and thrombus. Thus, the relationship between the diameter of the coronary arteries was evaluated to be used as a reference data before the treatment of coronary arteries and drug selection in patients with AF. From January 2020 to August 2022, images of coronary angiography (CAG) with AF and normal sinus rhythm (NSR) on electrocardiography were target. In both subjects, images of normal coronary artery without lesions as a result of CAG were used. For all vessels, the diameters of the vessels were measured by dividing them into proximal, middle, and distal parts, and the measured diameters were divided by the average for evaluation. As a result of analyzing the left anterior descending artery diameter, the vessel diameter of the AF patient was 2.24±0.26 mm, which was smaller than that of the NSR patient, 2.86±0.38 mm, and was statistically significant. (p<0.001) As a result of analyzing the left circumflex artery diameter, the vessel diameter of the AF patient was 2.34±0.28 mm, which was smaller than the vessel diameter of the NSR patient, 2.87±0.29 mm, and was statistically significant. (p<0.001) As a result of analyzing the diameter of the right coronary artery, the vessel diameter of the AF patient was 2.68±0.5 mm, which was smaller than the vessel diameter of the NSR patient, 3.35±0.4 mm, and was statistically significant. (p<0.001) Considering that the coronary artery size of AF patients is significantly smaller than the coronary vessel size of NSR patients, it is considered as a useful study to be used as a reference for evaluating coronary artery diameter when the arrhythmia is AF. In particular, it is considered to be a study that can be helpful in diagnosing lesions, using drugs before and after surgery, and choosing to use auxiliary devices such as intravascular ultrasound.

Efficacy and Safety of a Newly Developed Self-Expanding Open-Cell Type Nitinol Stent for Peripheral Arteries: A Preclinical Study in Minipigs (새로 개발된 말초동맥용 자가팽창성 개방형 니티놀 스텐트의 유효성 및 안전성 평가: 미니피그 전임상실험)

  • Min Uk Kim;Jae Hwan Lee;Chang Jin Yoon;Won Seok Choi;Saebeom Hur;Jin Wook Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.899-911
    • /
    • 2020
  • Purpose To evaluate the safety and efficacy of the newly designed open-cell type self-expandable nitinol stent (NiTi-stent) for peripheral arteries. Materials and Methods Twenty-eight limbs of 14 minipigs were randomly assigned to the NiTistent group or conventional nitinol stent group. Stents were symmetrically implanted into the iliac arteries of each animal using carotid artery approach and were observed for 1 month (n = 5) and 6 months (n = 9). The angiographic lumen diameter (ALD), late lumen loss, angiographic stenosis, histomorphometric lumen area, neointimal area, and area stenosis were analyzed and compared between the groups. Results Stent migration, stent fracture, or thrombus formation were not observed in either group. At the 1-month follow-up, the neointimal area (p = 0.008) and area stenosis (p = 0.016) were significantly smaller in the NiTi-stent group than in the control group. At the 6-months followup, the NiTi-stent group showed significantly larger ALD (p = 0.014), less late lumen loss (p = 0.019), less angiographic stenosis (p = 0.014), larger lumen area (p = 0.040), and smaller neointimal area and area stenosis (p = 0.004 and p = 0.014, respectively) compared with the control group. Conclusion The NiTi-stent is as safe and effective as the conventional nitinol stent and induces less neointimal hyperplasia in a minipig iliac artery model.

A Study on Risk Factors for Early Major Morbidity and Mortality in Multiple-valve Operations (중복판막수술후 조기성적에 영향을 미치는 인자에 관한 연구)

  • 한일용;조용길;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.233-241
    • /
    • 1998
  • To define the risk factors affecting the early major morbidity and mortality after multiple- valve operations, the preoperative, intraoperative and postoperative informations were retrospectively collected on 124 consecutive patients undergoing a multiple-valve operation between October 1985 and July 1996 at the department of Thoracic and Cardiovascular Surgery of Pusan Paik Hospital. The study population consists of 53 men and 71 women whose mean age was 37.9$\pm$11.5(mean$\pm$SD) years. Using the New York Heart Association(NYHA) classification, 41 patients(33.1%) were in functional class II, 60(48.4%) in class III, and 20(16.1%) in class IV preoperatively. Seven patients(5.6%) had undergone previous cardiac operations. Atrial fibrillations were present in 76 patients(61.3%), a history of cerebral embolism in 5(4.0%), and left atrial thrombus in 13(10.5%). The overall early mortality rate and postoperative morbidity was 8.1% and 21.8% respectively. Among the 124 cases of multiple-valve operation, there were 57(46.0%) of combined mitral valve replacement(MVR) and aortic valve replacement(AVR), 48(38.7%) of combined MVR and tricuspid annuloplasty(TVA), 12(9.7%) of combined MVR, AVR and TVA, 3(2.4%) of combined MVR and aortic valvuloplasty, 2(1.6%) of combined MVR and tricuspid valve replacement, and others. The patients were classified according to the postoperative outcomes; Group A(27 cases) included the patients who had early death or major morbidity such as low cardiac output syndrome, mediastinitis, cardiac rupture, ventricular arrhythmia, sepsis, and others; Group B(97 cases) included the patients who had the good postoperative outcomes. The patients were also classified into group of early death and survivor. In comparison of group A and group B, there were significant differences in aortic cross-clamping time(ACT, group A:153.4$\pm$42.4 minutes, group B:134.0$\pm$43.7 minutes, p=0.042), total bypass time(TBT, group A:187.4$\pm$65.5 minutes, group B:158.1$\pm$50.6 minutes, p=0.038), and NYHA functional class(I:33.3%, II:9.7%, III:20%, IV:50%, p=0.004). In comparison of early death(n=10) and survivor(n=114), there were significant differences in age(early death:45.2$\pm$8.7 years, survivor:37.2$\pm$11.6 years, p=0.036), sex(female:12.7%, male:1.9%, p=0.043), ACT(early death:167.1$\pm$38.4 minutes, survivor:135.7$\pm$43.7 minutes, p=0.030), and NYHA functional class(I:0%, II:4.9%, III:1.7%, IV:35%, p=0.001). In conclusion, the early major morbidity and mortality were influenced by the preoperative clinical status and therefore the earlier surgical intervention should be recommended whenever possible. Also, improved methods of myocardial protection and operative techniques may reduce the risk in patients with multiple-valve operation.

  • PDF

Development of Korean Version of Heparin-Coated Shunt (헤파린 표면처리된 국산화 혈관우회도관의 개발)

  • Sun, Kyung;Park, Ki-Dong;Baik, Kwang-Je;Lee, Hye-Won;Choi, Jong-Won;Kim, Seung-Chol;Kim, Taik-Jin;Lee, Seung-Yeol;Kim, Kwang-Taek;Kim, Hyoung-Mook;Lee, In-Sung
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.97-107
    • /
    • 1999
  • Background: This study was designed to develop a Korean version of the heparin-coated vascular bypass shunt by using a physical dispersing technique. The safety and effectiveness of the thrombo-resistant shunt were tested in experimental animals. Material and Method: A bypass shunt model was constructed on the descending thoracic aorta of 21 adult mongrel dogs(17.5-25 kg). The animals were divided into groups of no-treatment(CONTROL group; n=3), no-treatment with systemic heparinization(HEPARIN group; n=6), Gott heparin shunt (GOTT group; n=6), or Korean heparin shunt(KIST group; n=6). Parameters observed were complete blood cell counts, coagulation profiles, kidney and liver function(BUN/Cr and AST/ ALT), and surface scanning electron microscope(SSEM) findings. Blood was sampled from the aortic blood distal to the shunt and was compared before the bypass and at 2 hours after the bypass. Result: There were no differences between the groups before the bypass. At bypass 2 hours, platelet level increased in the HEPARIN and GOTT groups(p<0.05), but there were no differences between the groups. Changes in other blood cell counts were insignificant between the groups. Activated clotting time, activated partial thromboplastin time, and thrombin time were prolonged in the HEPARIN group(p<0.05) and differences between the groups were significant(p<0.005). Prothrombin time increased in the GOTT group(p<0.05) without having any differences between the groups. Changes in fibrinogen level were insignificant between the groups. Antithrombin III levels were increased in the HEPARIN and KIST groups(p<0.05), and the inter-group differences were also significant(p<0.05). Protein C level decreased in the HEPARIN group(p<0.05) without having any differences between the groups. BUN levels increased in all groups, especially in the HEPARIN and KIST groups(p<0.05), but there were no differences between the groups. Changes of Cr, AST, and ALT levels were insignificant between the groups. SSEM findings revealed severe aggregation of platelets and other cellular elements in the CONTROL group, and the HEPARIN group showed more adherence of the cellular elements than the GOTT or KIST group. Conclusion: Above results show that the heparin-coated bypass shunts(either GOTT or KIST) can suppress thrombus formation on the surface without inducing bleeding tendencies, while systemic heparinization(HEPARIN) may not be able to block activation of the coagulation system on the surface in contact with foreign materials but increases the bleeding tendencies. We also conclude that the thrombo-resistant effects of the Korean version of heparin shunt(KIST) are similar to those of the commercialized heparin shunt(GOTT).

  • PDF