• 제목/요약/키워드: Throat Area

검색결과 158건 처리시간 0.029초

가변형 음속/초음속 이젝터 시스템에 관한 실험적 연구 (An Experimental Study of the Variable Sonic/supersonic Ejector Systems)

  • 이준희;김희동
    • 대한기계학회논문집B
    • /
    • 제29권5호
    • /
    • pp.554-560
    • /
    • 2005
  • A new method to improve the efficiency of a hydrogen fuel cell system was introduced by using variable sonic/supersonic ejectors. To obtain the variable area ratio of the nozzle throat to ejector throat which controls the mass flow rate of the suction flow, the ejectors used a movable cylinder inserted into a conventional ejector-diffuser system. Experiments were carried out to understand the flow characteristics inside the variable ejector system. The secondary mass flow rates of subsonic and supersonic ejectors were examined by varying the operating pressure ratio and area ratio. The results showed that the variable sonic/supersonic ejectors could control the recirculation ratio by changing the throat area ratio, and also showed that the recirculation ratio increased fur the variable sonic ejector and decreased for the variable supersonic ejector, as the throat area ratio increases.

가변형 음속 이젝터 시스템에 관한 실험적 연구 (An Experimental Study on the Variable Sonic Ejector System)

  • 이준희;정성재;김희동;구병수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2035-2040
    • /
    • 2004
  • A cone cylinder is used to obtain variable operation conditions for the sonic ejector-diffuser system. The cone cylinder is designed to move upstream and downstream to change the ejector throat area ratio, thus obtaining variable mass flow rates. The present study investigates the effects of ejector throat area ratio and operating pressure ratio on the entrainment of secondary stream for the variable sonic ejector system. In experiment, the ejector throat area is varied in the range from ${\psi}=11.88$ to 66.69, and the operating pressure ratio from $p_{0p}/p_a=1.25$ to 9.0. The results show that the variable sonic ejector system is suitable for a required entrainment ratio of secondary stream by altering the ejector throat area ratio and operating pressure ratio.

  • PDF

A Study of a Variable Sonic Ejector Flow

  • Lee, Jun-Hee;Kim, Heuy-Dong
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.414-417
    • /
    • 2004
  • A cone cylinder is used to obtain variable operation conditions for the sonic ejector-diffuser system. The cone cylinder is designed to be shifted upstream and downstream to change the ejector throat area ratio, thus obtaining variable mass flow rates. The present study investigates the effects of ejector throat area ratio and operating pressure ratio on the entrainment of secondary stream for the variable sonic ejector system. The study is carried out experimentally. The ejector throat area is varied at the range from Ψ= 11.88 to 66.69, and the operating pressure ratio is changed from $P_{op}$ / $P_{a}$=1.25 to 9.0. The results show that the variable sonic ejector system can be operated to obtain specific entrainment ratio of secondary stream by altering the ejector throat area ratio and operating pressure ratio.o.

  • PDF

이중목 노즐에서 발생하는 초음속유동 특성에 관한 연구 (A Study on the Supersonic Flow Characteristics Through a Dual Throat Nozzle)

  • 신춘식;김희동
    • 한국추진공학회지
    • /
    • 제14권5호
    • /
    • pp.1-7
    • /
    • 2010
  • 최근 이중목 노즐(Dual Throat Nozzle, DTN)을 사용하여 추진체의 추력을 제어하는 방 이 많은 주목을 받고 있다. 이중목 노즐은 공동을 사이에 두고 두 개의 노즐 목을 가지도록 설계된다. 본 연구에서는 DTN의 기초 유동특성을 조사하기 위하여, 수치해석적인 방법을 적용하였으며, 노즐압력비와 노즐목 면적비를 변화시켰다. 수치해석에서는 축대칭, 압축성 Navier-Stokes방정식을 풀기 위하여, 유한체적법을 적용하였다. 그 결과 본 수치해석은 실험결과를 잘 예측하였으며, DTN의 성능을 추력계수와 유출계수의 항으로 상세하게 설명하였다.

베인 디퓨져 목 형상비 변화에 따른 소형 터보압축기 성능특성 고찰 (Performance Characteristics of a Small-Size Turbo-Compressor with Different Vaned Diffuser Throat Area Ratios)

  • 김홍식;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.120-125
    • /
    • 2001
  • The effects of various vaned diffuser configurations, such as throat area ratios and rectangular and conical cross-section shapes. to the performance of a small-size turbo-compressor are studied. Numerical analyses were carried out for the region of diffuser and casing only. The pressure recovery coefficient was calculated to estimate the performance of the diffuser, and then compared with the measured data. Results show that the shapes and the throat area ratios of the diffuser strongly influence on the performance of a turbo-compressor.

  • PDF

가변형 음속 이젝터 유동에 관한 수치해석적 연구 (A Computational Study of a Variable Sonic Ejector Flow)

  • 이준희;최보규;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.526-531
    • /
    • 2003
  • A cone cylinder is used to obtain variable operation conditions of a sonic ejector-diffuser system. The cone cylinder is movable to change the ejector area ratio, thus obtaining variable mass flow rates. The present study investigates the effects of ejector throat area ratio and operating pressure ratio on the entrainment of secondary stream. The numerical simulations are based on a fully implicit finite volume scheme of the compressible, Reynolds-Averaged, Navier-Stokes equations. The ejector throat area is varied between 3.94 and 8.05, and the operating pressure ratio is changed from 3.0 to 9.0. The results show that the entrainment ratio and mass flux ratio become more dependent on the ejector throat area ratio, when the pressure operating ratio is low. The total pressure losses produced in the present ejector system increase with the operating pressure ratio and the ejector area ratio, but for a given operating pressure ratio, the losses are not significantly dependent on the ejector area ratio when it is larger than about 5.0.

  • PDF

Study on the Off-design Performance on a Plug Nozzle with Variable Throat Area

  • Azuma, Nobuyuki;Tanatsugu, Nobuhiro;Sato, Tetsuya;Kobayashi, Hiroaki;Hongo, Motoyuki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.644-648
    • /
    • 2004
  • In the present study were examined numerically and experimentally the off-design performance characteristics on an axisymmetric plug nozzle with variable throat area. In this nozzle concept, its throat area can be changed by translating the plug into the axial direction. First, a mixed-expansion plug nozzle, in which two expansion parts are arranged both inside and outside, was designed by means of the method of characteristics. Second, the CFD analysis was verified by the cold-flow wind tunnel test. Third, its performance characteristics were evaluated over a wide range of pressure ratio from half to double throat area through the design point, using the CFD code verified by the wind tunnel tests. It was made clear from the study that not so critical thrust efficiency losses were found and the maximum thrust efficiency loss was at most approximately 5 % under off-design conditions without external flow. This result shows that a plug nozzle can give the altitude compensation even under off-design geometry operations. However, shock waves were observed in the inner expansion part under the doubled throat area operation and thus some thermal problems may be caused on the plug surface. Furthermore, collapse of cell structure on the plug surface was observed with external flow (around Mach number 2.0) as it became lower pressure ratio below the design point and the fact may result in big efficiency loss regardless of geometrical configuration.

  • PDF

와류실식 디젤기관의 배기배출물 저감을 위한 연소실의 압축비 및 분구면적비 개선 (Improving Compression and Throat Ratios of Combustion Chamber for Reduction of Exhaust Emissions for a Swirl Chamber Type Diesel Engine)

  • 이창규;허윤근;서신원
    • 농업과학연구
    • /
    • 제37권3호
    • /
    • pp.501-508
    • /
    • 2010
  • A swirl chamber type diesel engine attachable to 18 kW agricultural tractors was improved to reduce exhaust emissions. Compression ratio and throat area ratio of the combustion chamber were varied to determine optimum combustion conditions. Tests were composed of full load and 8-mode emission tests. Compression ratio was fixed as 21, but the swirl chamber volume was increased by 3.8%. Output power, torque, specific fuel consumption, exhaust gas temperature, and smoke level were not considerably different for compression ratios of 21.5 (reference condition) and 21 (test condition), while NOx, HC, CO and PM levels for the compression ratio of 21 were decreased by 11%, 46%, 28%, 11%, respectively, from those for the compression ratio of 21.5. The tests were also conducted with a compression ratio of 22 and 4.3% increased chamber volume. Output power, torque, exhaust gas temperature and smoke level were greater, while specific fuel consumption was less for the compression ratio of 22 than those for the compression ratio of 21.5. Increase of compression ratio decreased HC and CO levels by 24%, 39%, but increased NOx and PM levels by 24%, 39%. Based on these results, a compression ratio of 21 was selected as an optimum value. Then, full load tests with the selected compression ratio of 21 were carried out for different throat ratios of 1.0%, 1.1%, 1.2%. Output power and torque were greatest and smoke was lowest when throat area ratio was 1.1%, which satisfied the target values of specific fuel consumption (less than 272 g/$kW{\cdot}h$) and exhaust gas temperature (less than $550^{\circ}C$). Therefore, a throat area ratio of 1.1% was selected as an optimum value.

화학레이저 구동용 이젝터 시스템 개발 (II) - 이차목 형태의 환형 초음속 이젝터 최적 설계 - (Development of an Ejector System for Operation of Chemical Lasers (II) - Optimal Design of the Second-Throat Type Annular Supersonic Ejector -)

  • 김세훈;진정근;권세진
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1231-1237
    • /
    • 2004
  • Determination of geometric design parameters of a second-throat type annual supersonic ejector is described. Tested geometric parameters were primary nozzle area ratio, cross-sectional area of second-throat, L/D ratio of second-throat and primary flow injection angle. Varying these four geometric parameters, we build a test matrix made of 81 test conditions, and experimental apparatus was fabricated to accommodate them. For each test condition, the stagnation pressure of primary flow and the static pressure of the secondary flow were measured simultaneously along with their transition to steady operation and finally to unstarting condition. Comparing the performance curve of every case focused on starting pressure, the unstarting pressure and the minimum secondary pressure, we could derive correlations that the parameters have on the performance of the ejector and presented the optimal design method of the ejector. Additional experiments were carried out to find effects of temperature and mass flow rate of the secondary flow.

液休용 이젝터 性能에 관한 CAD와 實驗結果와의 比較 (The Comparison of Experimental Results of Liquid Ejector Performance to Predictions by the Computer Aided Design Program)

  • 김경근;김명환;홍영표;고상철
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.520-527
    • /
    • 1988
  • 본 연구에서는 액체용 이젝터의 성능을 결정하는 여러가지 제약인자중 특히 레이놀즈수 변화에 따른 구동노즐의 면적비 및 목부길이가 액체용 이제터성능에 미치 는 영향을 체계적인 실험을 통하여 연구함으로써 기 개발된 CAD용 전산프로그램의 타 당성을 보다 세밀히 검토하고 이에 보완을 가하는데 연구의 목적이 있다.