• 제목/요약/키워드: Threshold of 0.5%

검색결과 1,172건 처리시간 0.022초

개의 발에 염증 유발 후 전침이 통증역치 및 뇌줄기 큰솔기핵의 5-Hydroxytryptamine 합성에 미치는 효과 (The Effect of Electroacupuncture on Pain Threshold and 5.Hydroxytryptamine Synthesis Induced by Nociception in the Raphe Magnus Nucleus of Dog Brain Stem)

  • 조미숙
    • The Journal of Korean Physical Therapy
    • /
    • 제23권1호
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of electroacupuncture on pain threshold and 5-HT synthesis in raphe magnus nucleus of dog brain stem following nociception induced by 1% carageenan. Method: Twenty male dogs were randomly divided into two groups, a control group and an electroacupuncture group with the following parameters: ST36, LI11 and SP9 with 120Hz and 0.5mA. The dogs were sacrificed at 30, 60, 90, 120, 150 and 180 min after nociception using 1% carageenan injection into the plantar side of the dog's left leg. The pain threshold was recorded by an Analgesia-meter. After making brain slice sections, the tissues were immunostained with 5-HT antisera (1:2,500). Results: The pain threshold for the electroacupuncture group was higher than for the control group. The number of 5-HT immunoreactive neurons in the electroacupuncture group was greater than that of the control group. Differences between the two groups regarding the number of 5-HT immunoreactive neurons at 30 min and 60 min (p<0.05), at 120 min and 150 min (p<0.01), and at 8 days (p<0.05) were significant. Conclusion: The increases in pain threshold and number of 5-HT immunoreactive neurons in the raphe magnus nucleus of dog brain stem showed that electroacupuncture can attenuate pain transduction through the descending tract.

직선 편광 근적외선 조사가 건강인의 실험적 통증역치에 미치는 영향 (Effect of Linear Polarized Near-Infrared Ray Radiation on the Experimental Pain Threshold in Healthy Subjects)

  • 이재형;송인영;최은영
    • 대한물리치료과학회지
    • /
    • 제2권4호
    • /
    • pp.771-778
    • /
    • 1995
  • 편광 근적외선 조사가 실험적 통증역치에 영향을 미치는지를 규명하기 위해서 건강한 성인의 합곡혈에 여러 단계의 출력량으로 편광 근적외선을 30초간 조사하고 시간 경과에 따라 실험적 통증역치를 측정하여 분석하였다. 실험 결과 출력량 0 %인 대조군과 10 % 및 20 %의 출력량에서는 실험적 통증역치의 유의한 변화가 없었다. 그러나 출력량 40 %군의 실험적 통증역치는 편광 근적외선 조사전 $3.85{\pm}0.51mA$에서 조사 직후 $4.77{\pm}0.87mA$, 조사 후 30분 $5.57{\pm}0.98mA$, 조사 후 1시간 $5.68{\pm}1.06mA$, 조사 후 2시간 $5.34{\pm}0.96mA$로 증가되었고, 출력량 80 %군에서도 실험적 통증역치가 조사전 $3.87{\pm}0.92mA$에서 조사 직후 $4.45{\pm}0.62mA$, 조사 후 30분 $4.91{\pm}0.51mA$, 조사 후 1시간 $4.93{\pm}0.62mA$, 조사 후 2시간 $5.55{\pm}1.11mA$로 증가하였다. 실험적 통증역치는 편광 근적외선 조사 직후부터 2시간까지 유의하게 증가하였다. 40 % 출력량과 80 % 출력량의 실험적 통증역치는 유의한 차이가 없었고, 출력량과 시간의 상호작용효과는 없었다. 건강인의 실험적 통증역치를 대상으로 한 본 연구 결과를 통증이 있는 환자에게 직접 적용하기는 어렵다고 생각하며 앞으로 환자를 대상으로한 연구가 수행되기를 기대한다.

  • PDF

방사선 조사 전분류의 확인을 위한 점도측정조건 및 threshold values 설정 (Establishment of Viscosity Measuring Conditions and Threshold Values for Identifying Irradiated Starches)

  • 안경아;최종동;김현구;권중호
    • 한국식품과학회지
    • /
    • 제36권5호
    • /
    • pp.693-700
    • /
    • 2004
  • 방사선 조사 전분류의 확인방법을 연구하기 위하여 옥수수 전분, 고구마 전분 및 감자 전분을 대상으로 Brookfield rheometer를 이용한 점도측정법의 적용 가능성을 검토하면서, 전분현탁액의 농도(7.0-9.5%)와 점도계의 spindle 회전속도(25-125rpm)가 감마선 조사(0-6.0kGy) 시료의 점도에 미치는 영향을 조사하였다. 모든 변수들의 관계에서 조사선량과 점도의 상관성이 가장 높은 조건을 선택하여 점도 측정을 위한 최적 조건으로 설정하고, 아울러 조사 전분에 대한 검지방법으로 적용하기 위하여 점도 threshold value를 설정하였다. 모든 시료에서 조사선량이 증가함에 따라 점도가 유의적으로 감소하였으며 (p<0.05), 시료 현탁액의 농도가 증가할수록 점도가 증가하고 rpm이 증가할수록 점도는 감소하는 경향을 보였다. 조사 전분의 확인에 있어서, 점도 측정조건으로 유용한 전분 농도(%)와 spindle 회전속도(rpm)는 옥수수 전분 7.5(6.7%, d.b.)와 125, 고구마 전분 8.5(7.3%, d.b.)와 125, 감자 전분 9.0(7.3%, d.b.)와 100이었다. 그리고 이 조건에서 threshold value는 비조사 시료가 0.521, 0.798 및 1.693임에 비해 최저 선량인 1.5 kGy 조사시료는 0.313, 0.345 및 0.811로 뚜렷한 차이를 보여 감마선 조사 시료는 비조사 시료로부터 확인이 가능하였다.

젊은 한국여성에서 붉은고추의 섭취량, 캡사이신 역치, 영양소 섭취량 및 신체계측치간의 관련성 (Relationship between Red Pepper Intake, Capsaicin Threshold, Nutrient Intake, and Anthropometric Measurements in Young Korean Women)

  • 김석영;박경민
    • Journal of Nutrition and Health
    • /
    • 제38권1호
    • /
    • pp.76-81
    • /
    • 2005
  • The effects of the amount of red pepper intake per a day on the capsaicin threshold, nutrient intake, and anthropo-metric measurements were investigated in 100 female students of university. Three 24-hour recalls were performed to estimate usual nutrient and red pepper intake of free-living participants. The solutions containing capsaicin at concentration of 0.05, 0.1, 0.2, 0.3, 0.4, 0.5ppm used for the evaluation of hot-taste detection threshold. Subjects were asked to recognize the burning sensation after tasting l0ml of each test solution in ascending order of capsaicin concentrations. Mean intake of red pepper was 4.6 g/d and the capsaicin threshold was 0.27 ppm. The detection threshold for capsaicin was correlated with the amount of pepper intake per a day. Red pepper intake was correlated with energy, protein, lipid, carbohydrate, Iron, vitamin A, vitamin B$_2$ niacin, and vitamin E intakes. However, it was not correlated with intake of calcium, vitamin B$_1$ or vitamin C. The red pepper intake was negatively correlated with fat mass and waist girth and the capsaicin threshold was also negatively correlated with pulse. In conclusion, red pepper intake was associated with nutrient intake and capsaicin threshold whereas it was negatively correlated with fat mass and waist girth.

파라미터의 변경에 따라 나선형 전산화 단층 촬영의 체적 변화 (Volume Change of Spiral Computed Tomography due to the Changed in the Parameters)

  • 이준행
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.307-311
    • /
    • 2013
  • 본 논문에서는 피폭선량 절감을 위해 기존의 선량보다 낮은 선량으로 CT검사를 했을 경우에 병변의 유무를 충분히 가릴 수 있는지 scan parameter(절편두께, Helical Pitch)와 3차원으로 영상재구성시 threshold값의 설정에 따른 영상의 변화정도를 3차원 영상화를 통하여 시료의 체적 변화를 알아보고, 피폭선량절감을 위한 CT에서 허용 가능한 scan parameter를 찾고자 연구를 시도하였다. 실험방법으로는 실리콘을 이용하여 시료를 제작하였으며, 이때 시료의 크기는 직경이 50, 40, 30, 20, 10mm로 10mm 간격으로 5개의 구형 모형을 제작하였고, 5개의 시료를 관전압, 관전류를 각각 120Kvp, 50mA로 고정하고, 단면두께(1.0, 2.0, 3.0, 5.0, 7.0mm), Helical Pitch(1.5, 2.0, 3.0)를 각각 변화시켜 Scan 하고 영상 간의 interval은 (1.0, 2.0, 3.0, 5.0, 7.0mm)로 구성하여, 영상을 workstation으로 전송하고, Volume Rendering Technique를 사용하여 threshold(-200,-50,50 ~1,000) 값을 변화시키면서 3차원 영상으로 재구성하고, 시료의 체적을 측정하였다. 실험결과 Helical pitch가 1.5일 때 체적변화가 가장 적었고, Helical pitch가 3.0일 때 체적변화가 가장 많이 감소하였으며, 절편두께가 증가할수록 시료의 체적도 실측치보다 감소한다는 것을 실험을 통해 확인 할 수 있었다. 또한 3차원 영상재구성시 threshold 범위를 -200~1,000으로 설정한 경우, 시료의 체적의 변화가 가장 적은 것으로 나타났다.

p-채널 다결정 실리콘 박막 트랜지스터의 문턱전압 변동을 보상할 수 있는 5-TFT OLED 화소회로 (5-TFT OLED Pixel Circuit Compensating Threshold Voltage Variation of p-channel Poly-Si TFTs)

  • 정훈주
    • 한국전자통신학회논문지
    • /
    • 제9권3호
    • /
    • pp.279-284
    • /
    • 2014
  • 본 논문에서는 p-채널 저온 다결정 실리콘 박막 트랜지스터의 문턱전압 변동을 보상할 수 있는 새로운 OLED 화소회로를 제안하였다. 제안한 5-TFT OLED 화소회로는 4개의 스위칭 박막 트랜지스터, 1개의 OLED 구동 박막 트랜지스터 및 1개의 정전용량으로 구성되어 있다. 제안한 화소회로의 한 프레임은 초기화 구간, 문턱전압 감지 및 데이터 기입 구간, 데이터 유지 구간 및 발광 구간으로 나누어진다. SmartSpice 시뮬레이션 결과, 구동 트랜지스터의 문턱전압이 ${\pm}0.25V$ 변동 시 최대 OLED 전류의 오차율은 -4.06%이였고 구동 트랜지스터의 문턱전압이 ${\pm}0.50V$ 변동 시 최대 OLED 전류의 오차율은 9.74%였다. 따라서 제안한 5T1C 화소회로는 p-채널 다결정 실리콘 박막 트랜지스터의 문턱전압 변동에 둔감하여 균일한 OLED 전류를 공급함을 확인하였다.

Should Threshold Growth Be Considered a Major Feature in the Diagnosis of Hepatocellular Carcinoma Using LI-RADS?

  • Jae Hyon Park;Yong Eun Chung;Nieun Seo;Jin-Young Choi;Mi-Suk Park;Myeong-Jin Kim
    • Korean Journal of Radiology
    • /
    • 제22권10호
    • /
    • pp.1628-1639
    • /
    • 2021
  • Objective: Based on the Liver Imaging Reporting and Data System version 2018 (LI-RADS, v2018), this study aimed to analyze LR-5 diagnostic performance for hepatocellular carcinoma (HCC) when threshold growth as a major feature is replaced by a more HCC-specific ancillary feature, as well as the frequency of threshold growth in HCC and non-HCC malignancies and its association with tumor size. Materials and Methods: This retrospective study included treatment-naive patients who underwent gadoxetate disodium-enhanced MRIs for focal hepatic lesions and surgery between January 2009 and December 2016. The frequency of major and ancillary features was evaluated for HCC and non-HCC malignancies, and the LR-category was assessed. Ancillary features that were significantly more prevalent in HCC were then used to either replace threshold growth or were added as additional major features, and the diagnostic performance of the readjusted LR category was compared to the LI-RADS v2018. Results: A total of 1013 observations were analyzed. Unlike arterial phase hyperenhancement, washout, or enhancing capsule which were more prevalent in HCCs than in non-HCC malignancies (521/616 vs. 18/58, 489/616 vs. 19/58, and 181/616 vs. 5/58, respectively; p < 0.001), threshold growth was more prevalent in non-HCC malignancies than in HCCs (11/23 vs. 17/119; p < 0.001). The mean size of non-HCC malignancies showing threshold growth was significantly smaller than that of non-HCC malignancies without threshold growth (22.2 mm vs. 42.9 mm, p = 0.040). Similar results were found for HCCs; however, the difference was not significant (26.8 mm vs. 33.1 mm, p = 0.184). Additionally, Fat-in-nodule was more frequent in HCCs than in non-HCC malignancies (99/616 vs. 2/58, p = 0.010). When threshold growth and fat-in-nodule were considered as ancillary and major features, respectively, LR-5 sensitivity (73.2% vs. 73.9%, p = 0.289) and specificity (98.2% vs. 98.5%, p > 0.999) were comparable to the LI-RADS v2018. Conclusion: Threshold growth is not a significant diagnostic indicator of HCC and is more common in non-HCC malignancies. The diagnostic performance of LR-5 was comparable when threshold growth was recategorized as an ancillary feature and replaced by a more HCC-specific ancillary feature.

소음노출량측정기의 Set Up 방법간의 시간가중평균값(TWA)의 차이 (Difference of Time Weighted Averages in Different Setting Ups for Noise Dosimeter)

  • 양흥석;이광묵;원정일
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.193-199
    • /
    • 1995
  • This study was designed to investigate the difference of time weighted average(TWA) of noise levels and noise doses by the different operating parameter settings such as exchange rate, threshold level and criterion level for noise dosimeter in the field measurements of noise at industrial working environments. The time weighted averages of noise level and noise doses for noise working environments were determined by noise dosimeter on 80 workers employed at 20 industrial establishments of 8 industries. The results obtained were as follows: 1. The mean time weighted average(TWA) of the noise working environments by the operating parameter settings showed 93.4 dB(A) in 3 dB of exchange rate, 80 dB of threshold level and 90dB of criterion level 92.0 dB(A) in 3 dB-exchange rate, 90 dB-threshold level and 90 dB-criterion level, in 90.8 dB(A) in 5 dB of exchange rate, 80 dB of threshold level and 90 dB of criterion level, and 86.7 dB(A) in 5 dB of exchange rate, 90 dB of threshold level and 90dB of criterion level. 2. ln group of noise level less than 90 dB(A), mean TWAs of 80 dB of threshold level were significantly higher than that of 90 dB of threshold level in 3 dB and 5 dB of exchange rate. 3. The case exceeded threshold limit value of noise was 49(61.3 %) in 3dB, 80dB and 90 dB setting, 44(55.0 %) in 3 dB, 90 dB, 90 dB setting, 33(41.3 %) in 5 dB, 80dB, 90 dB setting and 26(32.5%) in 5 dB, 90 dB, 90 dB setting. Above considerations in mind, it is suggested that exchange rate and threshold level be specified in related laws and regulations in the evaluation of working environments noise.

  • PDF

유역의 강우-유출 특성을 고려한 NRCS-CN 방법의 선행토양함수조건의 재설정: 선행5일강우량을 기준으로 (Re-establishing the Antecedent Moisture Condition of NRCS-CN Method Considering Rainfall-Runoff Characteristics in Watershed Based on Antecedent 5-Day Rainfall)

  • 유지영;문건우;안재현;김태웅
    • 대한토목학회논문집
    • /
    • 제34권3호
    • /
    • pp.849-858
    • /
    • 2014
  • 유효강우량을 산정하는 NRCS-CN 방법의 선행토양함수조건을 결정하기 위하여 일반적으로 선행5일강수량이 사용된다. 본 연구에서는 유역의 유출특성을 고려하여 선행5일강수량의 기준값을 재설정하기 위해서 선행5일강수량의 기준값을 변화시키면서 실제 관측 직접유출고와의 오차에 대한 비교 분석을 실시하였다. 그 결과, 전체 18개 대상유역에서 본 연구에서 재설정한 기준값을 적용하여 산정한 직접유출량의 평균오차(RMSE = 27.3 mm)는 일반적으로 적용되는 기준값을 적용하여 산정한 직접유출량의 평균오차(RMSE = 35.2 mm)보다 감소하는 것으로 확인되었다. 또한, 향상 지수를 바탕으로 유역별 선행5일강수량의 기준에 대한 효율성을 평가한 결과, 본 연구에서 재설정한 선행5일강수량의 기준값을 활용하여 직접유출량을 추정하였을 경우, 평균적으로 약 30% 정도의 정확도가 향상되는 것으로 확인되었다. 이와 더불어 본 연구에서는 미계측 유역에 대한 선행5일강수량의 기준값을 재설정하기 위하여 지형지표를 활용한 선형회귀모형을 제안하였다. 회귀모형을 이용하여 재조정된 선행5일강수량의 기준값을 적용할 경우, RMSE가 감소(최소 0.4 mm에서 최대 15.1 mm)함과 동시에 Nash and Sutcliffe의 효율성 계수는 최대 0.33까지 증가하였다.

Brief, Intense TENS 자극이 신경전도, 통증역치의 변화에 미치는 효과 (The effects of Breif, Intense Transecutaneous Electrical Nerve Stimulation on Nerve conduction, Pain Threshold in Healthy subjects)

  • 김태열;황태연;허춘복
    • The Journal of Korean Physical Therapy
    • /
    • 제6권1호
    • /
    • pp.171-183
    • /
    • 1994
  • Purphose. This present study examines the effect of brief, intense transcutaneous electrical nerve stimulation(BTENS) on sensory nerve conduction, electrical pain threshold, and two-point discrimination measured at the superficial radial nevre distribution in 20 healthy subjects. Subjects. Twenty volunteercs, (10 females and 10 males(age range : 20-38 years : $mean{\pm}SD\;:\;27.00{\pm}5.12$), only subjects without prior traumatological and pathological were eligible to participated in this study. Methods. Nerve conduction were determined for the right superficial radial nerve. Electrical pain threshold were determined for the right wrist ipsilateral to the site of BTENS. Small disc electrodes were attached to the surface of the skin stradding the end of the radius. Square wave electrical pulses were delivered from an isolated stimulator through a constant current device at a frequency of 2 Hz(5 ms pulse width). Two-point discrimination, measured on the sensory distribution of superficial radial nerve. BTENS was delivered using a Max-SD( Medical design co.) portable battery powered stimulator. A cicular Ag/AgCl electrode in contact with hypertonic saline gel was attached to the lateral(radial side) surface of the forearm. Results. No significant effects were observed between stimulation methods in the prestimulation cycle(multi-way ANOVA repeated measures : distal latency ; F1.14=0.332. amplitude ; F 0.80=0.445, pain threshold ; F0.06=0.940.2 point discrimination ; F1.50=0.236). Highly significant effects were observed time with the pretreatment and 6 posttreatment cycles(p<0.01). Mighty significants differences in nerve conduction and pain threshold were found using un multi-way ANOVA repeated measures among stimulation methods for each cycles(p<0.01). Conclusion and Discussion The authors concludes that both nerve conduction and pain threshold changes are associated with therapy (stimulation) level of BTENS.

  • PDF