• Title/Summary/Keyword: Threshold concentration

Search Result 465, Processing Time 0.024 seconds

Measurement of Low Hydrogen Sulfide Concentrations in the Coastal Area Near the Ulsan Industrial Complex (울산 산업단지인근 해변지역에서의 저 농도 황화수소 측정)

  • Yu, Mee Seon;Yang, Sung-Bong
    • Journal of Environmental Science International
    • /
    • v.25 no.11
    • /
    • pp.1555-1562
    • /
    • 2016
  • Concentrations of hydrogen sulfide in ambient air have been measured from January 2014 to June 2016 in a coastal area near the Ulsan National Industrial Complex. The measurement sites were 1 km, 2.6 km, 5.6 km, and 20 km away from a kraft pulp mill, which is located at the most southern edge of the complex. Concentrations above 0.4 ppb were monitored every 5 min and the highest concentration of the day was determined. From a total of 775 measurement days, hydrogen sulfide concentrations > 20 ppb were recorded on 36 and 38 days at the measurement site closest to the mill and the residential area 2.6 km away from the mill, respectively. At the site farthest from the mill, the concentrations were always 20 ppb lower than the malodor regulation for the residential area but sometimes higher than the odor recognition threshold for hydrogen sulfide. Although several emission sources of hydrogen sulfide have been published in the Pollutant Release and Transfer Register of Korea, the kraft pulp mill is considered to be the biggest contributor of atmospheric hydrogen sulfide in the southern coastal area of Ulsan.

Distribution of PCBs in Surface Sediments inside Seogwipo and Hallim Harbors of Jeju Island, Korea (제주도 서귀포항 및 한림항내 표층퇴적물의 PCBs 분포)

  • Cho, Eun-Il;Heo, Ryun-Yong;Lee, Min-Gyu;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.26 no.5
    • /
    • pp.639-649
    • /
    • 2017
  • Measurements of polychlorinated biphenyls (PCBs) were taken in surface sediments inside Seogwipo and Hallim Harbors of Jeju Island, Korea, to evaluate their distribution. These harbors typically have heavy ship traffic. The samples were collected three times (in June, October, and December, 2013). PCB concentrations in sediments from Seogwipo Harbor were higher than in those from Hallim Harbor, but both levels were very low, compared with those in other parts of the world. Sedimentary PCB levels had a strong correlation with organic carbon and fine granule mud content. PCB concentration values in the examined surface sediments were much lower than Sediment Quality Guidelines (SQGs) such as ER-L (Effect Rrange-Low), TEL (Threshold Effects Level) and ISQG (Interim Sediment Quality Guideline)-low value applied in countries, such as USA, Canada, and Australia. This suggests that the PCBs did not have significant biological effects on benthic organisms in the marine environment.

Cochlodinium Red Tide Effects on the Respiration of Abalone, Haliotis discus hannai Ino

  • Seo, Kyung-Suk;Lee, Chang-Kyu
    • ALGAE
    • /
    • v.22 no.3
    • /
    • pp.241-246
    • /
    • 2007
  • Cochtodinium votykrikoides -related red tide is the most notorious tidal bloom, resulting in mass mortality to marineanimals. This study aimed to test the effect of C. polyknkoides on the lethality to Haliotis discus hannai under con-trolled conditions. The oxygen demand of C. polykrikoides increases to reach its peak duhng the night, while the oxy-gen usage by H. discus hannai was continuously decreased with a threshold of 2 mg L U. The addition of C.polykrikoides did not effect the respiration of the H. discus hannai. However, the usage of oxygen by C. polykrikoidesduhng the night may lead to anoxia in the animal. With aeration, the level of dissolved oxygen (D.O.) was between6.06 and 7.28 mg LU; 90% of abalones survived even with a high concentration of C. potykrikoides (9000 cells mL U).Without aeration (3 mg LU of D.O.), however, the H. discus hannai suffocated immediately. Once 20 hours hadelapsed, all of the abalones were dead. The density of the H. discus hannai population contributed to their mortality.Therefore, aeration during the night and maintaining lower abalone densities is the best way to promote the sur-vivorship of H. discus hannai during a C. polykrikoides red tide.

Short Channel Analytical Model for High Electron Mobility Transistor to Obtain Higher Cut-Off Frequency Maintaining the Reliability of the Device

  • Gupta, Ritesh;Aggarwal, Sandeep Kumar;Gupta, Mridula;Gupta, R.S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.2
    • /
    • pp.120-131
    • /
    • 2007
  • A comprehensive short channel analytical model has been proposed for High Electron Mobility Transistor (HEMT) to obtain higher cut-off frequency maintaining the reliability of the device. The model has been proposed to consider generalized doping variation in the directions perpendicular to and along the channel. The effect of field plates and different gate-insulator geometry (T-gate, etc) have been considered by dividing the area between gate and the high band gap semiconductor into different regions along the channel having different insulator and metal combinations of different thicknesses and work function with the possibility that metal is in direct contact with the high band gap semiconductor. The variation obtained by gate-insulator geometry and field plates in the field and channel potential can be produced by varying doping concentration, metal work-function and gate-stack structures along the channel. The results so obtained for normal device structure have been compared with previous proposed model and numerical method (finite difference method) to prove the validity of the model.

EFFECT OF D-PROPRANOLOL ON TRANSMEMBRANE ACTION POTENTIAL OF CARDIAC PAPILLARY MUSCLE OF CAT (고양이 유두근의 활동전압에 미치는 d-propranolol의 영향)

  • Lee, Jong-Heun;Kim, Joong-Soo
    • The Journal of the Korean dental association
    • /
    • v.16 no.7 s.110
    • /
    • pp.531-536
    • /
    • 1978
  • Adult cats were light anesthetized with ethyl ether and heart was removed fastly. cardiac papillary muscle was dissected from heart in organ bath con taining Tyrode solution saturated with 95% O₂+5% CO₂, and prepared papillary muscles were placed in Tyrode solution that was continuously circulated and gassed with 95% O₂+5% CO₂at 32℃. The isolated papillary muscle was stimulated continuously with platinum pin electrode at frequency of 15/min and 90/min by means of electric stimulator and transmembrane action potentials were recorded with microelectrdes on the oscilloscope. The drug used was d-propranolol and its concentration was 0.5, 1.5 and 5.0 mg/L. The results obtained were as follows: 1. D-propranolol increased the threshold voltage of papillary muscle and raised by average of 213.6% of control. 2. D-propranolol had no effect on duration of action potential. 3. Conduction time of isolated papillary muscle was increased by d-propranolol and its effect was prominent at frequency of 90/min. 4. the maximum upstroke velocity was decreased by d-propranolol and its effect was dose-depndent decrease.

  • PDF

A study on effects of water-cement ratio and crack width on chloride ion transmission rate in concrete

  • Li, Yue;Chen, Xiaohan;Zhang, Guosheng
    • Computers and Concrete
    • /
    • v.19 no.4
    • /
    • pp.387-394
    • /
    • 2017
  • To study the effects of water-cement ratio changes and cracks on chloride ion transmission rate in cracked concrete, RCM method was adopted to accelerate the diffusion of chloride ion in cracked concrete, and the changes in chloride ion concentration and around the cracks are inferred by finite-element method. The test results show that as far as prefabricated cracks on concrete components are concerned, the width thresholds of two cracks on the concrete specimens with a water-cement ratio of 0.5 and 0.6 are 0.05 mm and 0.1 mm respectively, the width threshold of two cracks on the concrete specimens with a water-cement ratio of 0.4 is 0.05 mm and 0.2 mm respectively; and the results of numerical simulation show that the smaller the water-cement ratio is, the more significant effects of cracks on chloride ion transmission rate are. As a result, more attention shall be paid to the crack prevention, repairing and strengthening for high-strength concrete.

Reliability Analysis to Contaminant Migration in Saturated Sandy Soils: Implementation and Verification (포화(飽和)된 사질토(砂質土) 내로의 오염물(汚染物) 이동에 관한 신뢰성(信賴性): 수행(遂行) 및 검증(檢證))

  • Jang, Yeon Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.217-227
    • /
    • 1992
  • The first and second-order reliability method(FORM and SORM) is presented using one dimensional finite difference and two dimensional finite element transport models. FORM and SORM can be used without any restrictive assumptions about the properties of the media, and the sensitivity information obtained as part of these analyses is used to identify the parameters which have major influence on the estimate of probability. The reliability analysis of transport in a one-dimensional domain is used to test the robustness of the reliability code and to evaluate the accuracy of the reliability method. A continuous source 2-D example with a concentration threshold limit state function is used to evaluate the influence of the parameters in the location of interest on the reliability solution.

  • PDF

Lipid Peroxidation and the Thiobarbituric Acid Assay: Standardization of the Assay When Using Saturated and Unsaturated Fatty Acids

  • Rael, Leonard T.;Thomas, Gregory W.;Craun, Michael L.;Curtis, C. Gerald;Bar-Or, Raphael;Bar-Or, David
    • BMB Reports
    • /
    • v.37 no.6
    • /
    • pp.749-752
    • /
    • 2004
  • Saturated fatty acids are less vulnerable to lipid peroxidation than their unsaturated counterparts. In this investigation, individual fatty acids of the $C_{16}$, $C_{18}$ and $C_{20}$ families were subjected to the thiobarbituric (TBA) assay. These fatty acids were chosen based on their degree of saturation and configuration of double bonds. Interestingly, an assay threshold was reached where increasing the fatty acid concentration resulted in no additional decrease in the TBARS concentrations. Therefore, the linear range of TBARS inhibition was determined for fatty acids in the $C_{16}$ and $C_{20}$ families. The rate of TBARS inhibition was greater for the saturated than for unsaturated fatty acids, as measured from the slope of the linear range. These findings demonstrate the need to standardize the TBARS assay using multiple fatty acid concentrations when using this assay for measuring in vitro lipid peroxidation.

Effect of Salt on Facilitated Propylene Transport through Crosslinked PVA/Silver Salt Complex Membranes

  • Kim, Jong-Hak;Min, Byoung-Ryul;Lee, Ki-Bong;Kang, Yong-Soo
    • Korean Membrane Journal
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2006
  • Complex membranes consisting of silver salt ($AgBF_4,\;AgCF_3SO_3,\;AgSbF_6,\;AgNO_3$) and poly(vinyl alcohol) (PVA) or crosslinked PVA (CPVA) were prepared and tested for the separation of propylene/propane mixtures. For the tested membranes, the complex membranes containing $AgBF_4$ exhibited the highest separation properties, i.e., approximately 20 GPU ($1 GPU=10^{-6}cm^3 (STP)/(cm^2 sec cmHg)$) and 100 of selectivity at 0.2 of silver mole fraction. The CPVA membranes containing silver salt always showed higher selectivity than PVA membranes, presenting silver ions coordinated to -CHO are more effective than those to -OH groups. The threshold silver concentration of CPVA membranes was lower than that of PVA membranes, which might be due to stronger interaction of silver ions with -CHO than that with -OH. The composition at which the selectivity is the highest did not significantly depend on the crosslinking, but did on the kind of silver salt.

Electrical characteristics of polycrystalline 3C-SiC thin film diodes (다결정 3C-SiC 박막 다이오드의 전기적 특성)

  • Chung, Gwiy-Sang;Ahn, Jeong-Hak
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.259-262
    • /
    • 2007
  • This paper describes the electrical characteristics of polycrystalline (poly) 3C-SiC thin film diodes, in which poly 3C-SiC thin films on n-type and p-type Si wafers, respectively, were deposited by APCVD using HMDS, $H_{2}$, and Ar gas at $1150^{\circ}C$ for 3 hr. The schottky diode with Au/poly 3C-SiC/Si (n-type) structure was fabricated. Its threshold voltage ($V_{bi}$), breakdown voltage, thickness of depletion layer, and doping concentration ($N_{D}$) value were measured as 0.84 V, over 140 V, 61 nm, and $2.7{\times}10^{19}cm^{-3}$, respectively. Moreover, for the good ohmic contact, Al/poly 3C-SiC/Si (n-type) structure was annealed at 300, 400, and $500^{\circ}C$, respectively for 30 min under the vacuum condition of $5.0{\times}10^{-6}$ Torr. Finally, the p-n junction diodes fabricated on the poly 3C-Si/Si (p-type) were obtained like characteristics of single 3CSiC p-n junction diode. Therefore, poly 3C-SiC thin film diodes will be suitable for microsensors in conjunction with Si fabrication technology.