• Title/Summary/Keyword: Threshold Amplitude

Search Result 134, Processing Time 0.025 seconds

Accuracy Improvement Methode of Step Count Detection Using Variable Amplitude Threshold (가변 진폭 임계값을 이용한 걸음수 검출 정확도 향상 기법)

  • Ryu, Uk Jae;Kim, En Tae;An, Kyung Ho;Chang, Yun Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.6
    • /
    • pp.257-264
    • /
    • 2013
  • In this study, we have designed the variable amplitude threshold algorithm that can enhance the accuracy of step count using variable amplitude. This algorithm converts the x, y, z sensor values into a single energy value($E_t$) by using SVM(Signal Vector Magnitude) algorithm and can pick step count out over 99% of accuracy through the peak data detection algorithm and fixed peak threshold. To prove the results, We made the noise filtering with the fixed amplitude threshold from the amplitude of energy value that found out the detection error was increasing, and it's the key idea of the variable amplitude threshold that can be adapted on the continuous data evaluation. The experiment results shows that the variable amplitude threshold algorithm can improve the average step count accuracy up to 98.9% at 10 Hz sampling rate and 99.6% at 20Hz sampling rate.

Auditory Evoked Skin Potential in Normal Subjects (정상 성인에서 청성유발 피부전위)

  • Heo, Seung-Deok;Jung, Dong-Keun;Suh, Duk-Joon;Kim, Gwang-Nyeon;Kim, Gi-Ryon;Kang, Myung-Koo;Kim, Lee-Suk
    • Speech Sciences
    • /
    • v.12 no.2
    • /
    • pp.81-88
    • /
    • 2005
  • Electrodermal activity(EDA) is a bio-electric signal which occurs at the skin surface during the sweating. EDA reflects the activity of the sympathetic axis of the autonomic nervous system. EDA is associated with the eccrine sweat gland at the palmar and plamar surface. This study was aimed to characterize the relationship between EDA and auditory stimulus intensities. Acoustic stimulus used in this study were 500 Hz, 1 kHz, 2 kHz of narrow band noise, which were representative of speech frequencies in audible range. Stimulus intensity between 90 and 30 dB in 10 dB within dynamic range. After deriving the minimum stimulus intensity(threshold of skin potential) which elicited skin potential, and then the latency and amplitude were derived from waveform of skin potential, each latency and amplitude were compared to stimulus intensity. The waveform of skin potential were recorded stably, and the threshold of skin potential appeared nearly the hearing threshold level of the participant. The latency was decreased and the amplitude was increased according to the increase of the stimulus intensity. These results suggest that auditory evoked skin potential can be applicable to auditory assessment and audiological diagnosis tool.

  • PDF

Evaluation of pulse effect on frequency content of ground motions and definition of a new characteristic period

  • Yaghmaei-Sabegh, Saman
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.457-471
    • /
    • 2021
  • This study aims at providing a simple and effective methodology to define a meaningful characteristic period for special class of earthquake records named "pulse-like ground motions". In the proposed method, continuous wavelet transform is employed to extract the large pulse of ground motions. Then, Fourier amplitude spectra obtained from the original ground motion and the residual motion is simply compared. This comparison permits to define a threshold pulse-period (Tp∗) as the threshold period above which the pulse component has negligible contributions to the Fourier amplitude spectrum. The effect of pulse on frequency content of motions was discussed on the light of this definition. The advantage and superior features of the new definition were related to the inelastic displacement ratio (IDR) for single-degree-of-freedom systems with period equal to one half of the threshold period. Analyses performed for the proposed period at three ductility levels u=2,4,6 were compared with the results obtained at half of pulse period derived from wavelet analysis, peak-point method and the peak of product of the velocity and the displacement response spectra (Sv x Sd). According to the results, pulse effects on inelastic displacement ratio seem to be more important when $\frac{T_p^*}{T}=2$ (T is the fundamental vibration period of system). The results showed that utilizing of the proposed definition could facilitate an enhanced understanding of pulse-like records features.

Dynamic Properties of Soils at High Amplitude (With Emphasis on Threshold Strain) (흙의 고변형률 진동 특성(한계 변형률을 중심으로))

  • ;Stokoe K.H.Il
    • Geotechnical Engineering
    • /
    • v.7 no.2
    • /
    • pp.41-50
    • /
    • 1991
  • This study investigated the variation of the threshold strain and pore water pressure response of the coils at high amplitude vibration using resonant column test. As a result of tests, threshold shear strains of soft clay, clean quartz sand and stiff volcanic deposit were turned out to be 1$\times$10-2%, 1$\times$10-3%, 1$\times$10-4% respectively. Also, threshold shear Strain was found to be changed with confining pressure for the clean quartz sand. An increase of pore water pressure with shear strain was not significant within the shear strain 3~4$\times$10-3%, but it was abruptly increased beyond shear strain 1$\times$10-2%.

  • PDF

A Study on the Reliability Comparison of Median Frequency and Spike Parameter and the Improved Spike Detection Algorithm for the Muscle Fatigue Measurement (근피로도 측정을 위한 중간 주파수와 Spike 파라미터의 신뢰도 비교 및 향상된 Spike 검출 알고리듬에 관한 연구)

  • 이성주;홍기룡;이태우;이상훈;김성환
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.380-388
    • /
    • 2004
  • This study proposed an improved spike detection algorithm which automatically detects suitable spike threshold on the amplitude of surface electromyography(SEMG) signal during isometric contraction. The EMG data from the low back muscles was obtained in six channels and the proposed signal processing algorithm is compared with the median frequency and Gabriel's spike parameter. As a result, the reliability of spike parameter was inferior to the median frequency. This fact indicates that a spike parameter is inadequate for analysis of multi-channel EMG signal. Because of uncertainty of fixed spike threshold, the improved spike detection algorithm was proposed. It automatically detects suitable spike threshold depending on the amplitude of the EMG signal, and the proposed algorithm was able to detect optimal threshold based on mCFAR(modified Constant False Alarm Rate) in the every EMG channel. In conclusion, from the reliability points of view, neither median frequency nor existing spike detection algorithm was superior to the proposed method.

The effects of Breif, Intense Transecutaneous Electrical Nerve Stimulation on Nerve conduction, Pain Threshold in Healthy subjects (Brief, Intense TENS 자극이 신경전도, 통증역치의 변화에 미치는 효과)

  • Kim Tae-Youl;Hwang Tae-Yeun;Huh Choon-Bok
    • The Journal of Korean Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.171-183
    • /
    • 1994
  • Purphose. This present study examines the effect of brief, intense transcutaneous electrical nerve stimulation(BTENS) on sensory nerve conduction, electrical pain threshold, and two-point discrimination measured at the superficial radial nevre distribution in 20 healthy subjects. Subjects. Twenty volunteercs, (10 females and 10 males(age range : 20-38 years : $mean{\pm}SD\;:\;27.00{\pm}5.12$), only subjects without prior traumatological and pathological were eligible to participated in this study. Methods. Nerve conduction were determined for the right superficial radial nerve. Electrical pain threshold were determined for the right wrist ipsilateral to the site of BTENS. Small disc electrodes were attached to the surface of the skin stradding the end of the radius. Square wave electrical pulses were delivered from an isolated stimulator through a constant current device at a frequency of 2 Hz(5 ms pulse width). Two-point discrimination, measured on the sensory distribution of superficial radial nerve. BTENS was delivered using a Max-SD( Medical design co.) portable battery powered stimulator. A cicular Ag/AgCl electrode in contact with hypertonic saline gel was attached to the lateral(radial side) surface of the forearm. Results. No significant effects were observed between stimulation methods in the prestimulation cycle(multi-way ANOVA repeated measures : distal latency ; F1.14=0.332. amplitude ; F 0.80=0.445, pain threshold ; F0.06=0.940.2 point discrimination ; F1.50=0.236). Highly significant effects were observed time with the pretreatment and 6 posttreatment cycles(p<0.01). Mighty significants differences in nerve conduction and pain threshold were found using un multi-way ANOVA repeated measures among stimulation methods for each cycles(p<0.01). Conclusion and Discussion The authors concludes that both nerve conduction and pain threshold changes are associated with therapy (stimulation) level of BTENS.

  • PDF

CNT-PDMS Composite Thin-Film Transmitters for Highly Efficient Photoacoustic Energy Conversion

  • Song, Ju Ho;Heo, Jeongmin;Baac, Hyoung Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.297.2-297.2
    • /
    • 2016
  • Photoacoustic generation of ultrasound is an effective approach for development of high-frequency and high-amplitude ultrasound transmitters. This requires an efficient energy converter from optical input to acoustic output. For such photoacoustic conversion, various light-absorbing materials have been used such as metallic coating, dye-doped polymer composite, and nanostructure composite. These transmitters absorb laser pulses with 5-10 ns widths for generation of tens-of-MHz frequency ultrasound. The short optical pulse leads to rapid heating of the irradiated region and therefore fast thermal expansion before significant heat diffusion occurs to the surrounding. In this purpose, nanocomposite thin films containing gold nanoparticles, carbon nanotubes (CNTs), or carbon nanofibers have been recently proposed for high optical absorption, efficient thermoacosutic transfer, and mechanical robustness. These properties are necessary to produce a high-amplitude ultrasonic output under a low-energy optical input. Here, we investigate carbon nanotube (CNT)-polydimethylsiloxane (PDMS) composite transmitters and their nanostructure-originated characteristics enabling extraordinary energy conversion. We explain a thermoelastic energy conversion mechanism within the nanocomposite and examine nanostructures by using a scanning electron microscopy. Then, we measure laser-induced damage threshold of the transmitters against pulsed laser ablation. Particularly, laser-induced damage threshold has been largely overlooked so far in the development of photoacoustic transmitters. Higher damage threshold means that transmitters can withstand optical irradiation with higher laser energy and produce higher pressure output proportional to such optical input. We discuss an optimal design of CNT-PDMS composite transmitter for high-amplitude pressure generation (e.g. focused ultrasound transmitter) useful for therapeutic applications. It is fabricated using a focal structure (spherically concave substrate) that is coated with a CNT-PDMS composite layer. We also introduce some application examples of the high-amplitude focused transmitter based on the CNT-PDMS composite film.

  • PDF

X-ray fluorescence spectrum of the block algorithm to apply the interval threshold method using DWT (DWT를 이용한 형광 X-선 스펙트럼의 interval Threshold를 적용하기 위한 블록화 알고리즘)

  • Yang, Sang-Hoon;Lee, Jae-Hwan;Park, Dong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2291-2297
    • /
    • 2012
  • X-ray fluorescence sprectrum signal include the continuum. XRF analysis the components of material by the amplitude of peaks. XRF remove the noise and background. To remove the noise, we apply the smoothing filter. And background removal methods applied such as SNIP, Morphology, Threshold methods. In this paper, we applied Threshold using DWT. Interval threshold method divide the some blocks in particular levels. We propose the method that is divided the particular level.

A Study on the P Wave Arrival Time Determination Algorithm of Acoustic Emission (AE) Suitable for P Waves with Low Signal-to-Noise Ratios (낮은 신호 대 잡음비 특성을 지닌 탄성파 신호에 적합한 P파 도달시간 결정 알고리즘 연구)

  • Lee, K.S.;Kim, J.S.;Lee, C.S.;Yoon, C.H.;Choi, J.W.
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.349-358
    • /
    • 2011
  • This paper introduces a new P wave arrival time determination algorithm of acoustic emission (AE) suitable to identify P waves with low signal-to-noise ratio generated in rock masses around the high-level radioactive waste disposal repositories. The algorithms adopted for this paper were amplitude threshold picker, Akaike Information Criterion (AIC), two step AIC, and Hinkley criterion. The elastic waves were generated by Pencil Lead Break test on a granite sample, then mixed with white noise to make it difficult to distinguish P wave artificially. The results obtained from amplitude threshold picker, AIC, and Hinkley criterion produced relatively large error due to the low signal-to-noise ratio. On the other hand, two step AIC algorithm provided the correct results regardless of white noise so that the accuracy of source localization was more improved and could be satisfied with the error range.

Metal Drilling using Amplitude Modulated Laser Pulse (AM 변조된 레이저 펄스를 이용한 금속 Drilling)

  • Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1210-1212
    • /
    • 1994
  • An amplitude modulation technique for increasing the laser penetration efficiency for metals has been studied. By chopping electro-optically Nd:YAG laser pulse, the threshold energy for reliable hole drilling was decreased significantly and the penetration depth was increased. It was observed that the effect of chopping was optimal at 8-12 kHz with 60% duty cycle. It is believed that this improvement is due to an increase in the vapor recoil pressure and reduced plasma screening.

  • PDF