Analysis on the Characteristics of Voltage Unbalance Factor by Load Variations (부하 변동에 의한 전압불평형율의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.47-53
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating voltage unbalance. Voltage unbalance factor is mainly affected by load system rather than stable power system. Unbalanced voltage will draw a highly unbalanced current. As a result, the three-phase currents may differ considerably, thus resulting in an increased temperature rise in the machine. This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared by the current unbalance factor. Two methods are indicated similar results. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. Each phase has an impedance each other by the unbalanced operation pattern and give rise to voltage unbalance.

Three Phase AC-DC Converter with Elimination of Filter (LC필터를 제거한 3상 AC-DC 컨버터)

  • Kim, Jong-Dal;Nam, Jing-Rak;Lee, Ok-Hyeong;Kim, Joon-Hong;Sohn, Mu-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.76-79
    • /
    • 2004
  • This paper proposed that the conventional three phase AC-DC converter with bulk LC output filter has been widely used in the industry because of simple circuit, low cost and high power factor (90%). One of the biggest drawback of this three phase AC-DC converter is bulk and heavy. This is serious especially for aerospace applications. To solve this problem a new simple three phase AC-DC converter is presented. Operation of the proposed high power factor three phase AC-DC converter is illustrated and verified by PSpice simulation.

  • PDF

Driving Algorithm on Three Phase BLDC Motor Applied 4-Switch using Voltage Doubler (Voltage Doubler를 이용한 4-스위치 3상 BLDC 전동기 구동 알고리즘)

  • Yoon, Yong-Ho;Lee, Jung-Suk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.48-52
    • /
    • 2011
  • Over the years, traditionally, six-switch three-phase inverters have been widely utilized for variable speed alternating current motor drives. Recently, some efforts have been made on the application of four-switch three phase inverter for uninterruptible power supply and variable speed drives. This is due to some advantages of the four-switch three phase inverter over the conventional six-switch three-phase inverters such as reduced price due to reduction in number of switches, reduced switching losses, reduced number of interface circuits to supply logic signals for the switches, simpler control algorithms to generate logic signals, less chances of destroying the switches due to lesser interaction among switches, and less real-time computational burden. However such as slow di/dt and speed limitation, are the inherent characteristics and main drawbacks of the four-switch configuration. Those problems can be overcome in conjugation with Voltage-doublers which has additional advantage, such as unity power factor correction.

Three Phase Sinewave Soft-switching PWM Inverter using Bridge Type Resonant AC Link Snubber (브리지형 공진 AC 링크 스너버 방식을 이용한 3상 정현파 소프트 스위칭 PWM 인버터)

  • Kim, Jeong-Sik;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.58-62
    • /
    • 2017
  • This paper presents a novel prototype of the resonant AC link snubber circuit for the three-phase sinwave soft-switching PWM inverter. In principle, its operating principle is described, and the performance evaluations of the specific instantaneous space voltage modulated three-phase sinewave soft switching PWM inverter incorporating a resonant AC link snubber is illustrated, and evaluated, introducing the specific space voltage vector modulation implementation. It is conferred that the validity of three-phase soft-switching inverter treated here in setup experiment.

Neutral Point Voltage Control for Grid-Connected Three-Phase Three-Level Photovoltaic Inverter (계통연계형 3상 3레벨 태양광 인버터의 중성점 전압제어)

  • Park, Woonho;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.72-77
    • /
    • 2015
  • Three-level diode clamped multilevel inverter, generally known as neutral point clamped (NPC) inverter, has an inherent problem causing neutral point (NP) potential variation. Until now, the NP potential problem of variation has been investigated and lots of solutions have also been proposed. This paper presents a neutral point voltage control technology using the anti-windup PI controller and offset technology of PWM (Pulse Width Modulation) to control the variation of NPC 3-phase three-level inverter neutral point voltage. And the proposed algorithm is tested and verified using a PLL (Phase Locked Loop) in order to synchronize the phase voltage from the line voltage of grid. It significantly improves the voltage balancing under a solar fluctuation conditions of the inverter. Experimental results show the good performance and effectiveness of the proposed method.

Effective Algorithm in Steady-State Analysis for Variable-Speed and Constant-Speed Wind Turbine Coupled Three-Phase Self-Excited Induction Generator

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.3
    • /
    • pp.139-146
    • /
    • 2003
  • In this paper, the steady-state operating performance analysis for the three-phase squirrel cage rotor self-excited induction generator (SEIG) driven by a variable-speed prime mover (VSPM) in addition to a constant-speed prime mover (CSPM) is presented on the basis of an effective algorithm based on its frequency-domain equivalent circuit. The operating characteristics of the three-phase SEIG coupled by a VSPM and/or a CSPM are evaluated on line processing under the condition of the electrical passive load parameters variations with simple and efficient computation processing procedure in unregulated voltage control loop scheme. A three-phase SEIG prototype setup with a VSPM as well as a CSPM is implemented for the small-scale clean renewable and alternative energy utilizations. The experimental operating characteristic results are illustrated and give good agreements with the simulation ones.

Design of the Robust Hybrid Controller for Three-Phase Four-Leg Voltage Source Inverter under the Unbalance Load (불평형 부하에서 강인한 3상4족 전압형 인버터를 위한 하이브리드 제어기의 설계)

  • Doan, Van-Tuan;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.291-292
    • /
    • 2014
  • The three-phase four-leg voltage source inverter (VSI) topology can be an interesting option for the three phase-four wire system. With an additional leg, this topology can achieve superior performance with unbalanced and/or nonlinear load. This paper proposes a new hybrid controller which combines PI controller and resonant controller in synchronous frame for three phase four leg inverter. The hybrid controller is simple in structure and easy to implement. The performance of proposed controller is verified by the experiments and compared with that of the conventional PI controller.

  • PDF

Temperature Rise Prediction of 25.8kV 25kA Three-phase GIS Bus Bar (25.8kV 25kA 3상 GIS 모선의 온도상승 예측)

  • Kim, Joong-Kyoung;Hahn, Sung-Chin;Oh, Yeon-Ho;Park, Kyong-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.894-895
    • /
    • 2007
  • This paper presents coupled analysis between finite element method and analytic technique for predicting temperature rise of 25.8kV 25kA three-phase GIS bus bar. The power losses and temperature distribution of three-phase GIS bus bar model are analyzed by magneto-thermal finite element method. The heat transfer coefficients on the boundaries are analytically calculated by applying Nusselt number considering material constant and model geometry for the natural convection. And these are used as the input data to predict the temperature rise of three-phase GIS bus bar model by coupled magneto-thermal F.E.A. The predicted temperature of 25.8kV 25kA three-phase GIS bus bar model shows good agreement with the experimental data.

  • PDF

Detection of Orthopedic Disease Using Three Phase Radionuclide Bone Scan in the Dog (개에서 3단계 골스캔을 이용한 골병변의 진단)

  • 강성수;최석화
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.103-106
    • /
    • 2002
  • Specific diagnosis of orthopedic disease can be diffcult in canine practice. Failure to detect the clinical signs of a disorder during physical examination of dogs with acute or chronic lameness is the most common reason for failure to make specific diagnosis. A 6-month-old, female doberman with history of swelling and non-weight-bearing lameness in the left forelimb was referred to Beterinary Teaching Hospital of Chungbuk National University. Physical examination, plain radiography, and conventional three-phase radionuclide bone scan were performed in the patient. Based on the physical exam and radiography, this case was diagnosed as elbow strain and subluxation. Conventional three-phase bone scan detected soft tissue inflammation and osteochondral lesions of elbow joint, and revealed good agreement with clinical findings. Therefore, conventional three-phase bone scan was able to provide the precise information about inflammation of soft tissue and osteochondral lesions of joint.

A High Performance Three-Phase Telecom Supply Incorporating a HF Switched Mode Rectifier with a Phase Shifted PWM Controller

  • Shahani, Arushi;Singh, Bhim;Bhuvaneshwari, G.
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.219-227
    • /
    • 2010
  • Telecom supplies need to conform to low Total Harmonic Distortion (THD) and high Power Factor (PF) as per IEC 61000-3-2 and IEEE 519-1992 standards. These high rating power supplies use a three phase utility in which low THD and high PF are realized via various passive and active wave shaping schemes. In this paper, a new design for three phase telecom power supplies is presented with circuit parameter values optimized for high performance in terms of a low THD, high PF, low ripple and high line and load regulation using a suitable combination of various strategies. The performance of the power supply is validated by extensive simulations.