• Title/Summary/Keyword: ThreePhase

Search Result 6,254, Processing Time 0.034 seconds

A New Control of Three-Phase PWM Rectifier with Single Current Sensor (단일 전류 센서를 사용한 3상 PWM 정류기의 새로운 제어)

  • Lee, U-Cheol;Hyeon, Dong-Seok;Lee, Taek-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.440-447
    • /
    • 1999
  • This paper proposes a control method for three-phase PWM rectifier with only single current sensor in DC link side. A PWM modulation strategy for reconstructing three phase currents from the DC link current is given. The states of the retifier switch are modified so that all phase currents can be reconstructed in a switching period although one or two of active vectors is applied only for a short time. Therefore, a new current control using an adjustment scheme of the modulation signal for three-phase PWM rectifier will be discussed, and verified the experimental results.

  • PDF

Novel Third Harmonic Current Injection Technique for Harmonic Reduction of Controlled Converters

  • Eltamaly, Ali M.
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.925-934
    • /
    • 2012
  • Three-phase controlled converters have many applications in the utility interfacing of renewable energy sources and adjustable speed drives as a rectifier or inverter. The utility line currents of these converters have a high harmonic distortion, which is more than the harmonic standards. This paper introduces a new technique for circulating the third harmonic currents from the dc-link to the line currents to reduce their harmonic contents. The proposed system uses a single-phase PWM converter to control the angle and amplitude of the injection current for each of the firing angle of a three-phase converter. A detailed analysis is introduced to achieve a relationship between the firing angle of the three-phase controlled converter and the power angle of the PWM converter. In addition, a detailed design for the other injection path components is introduced. A simulation and experimental work is introduced to prove the mathematical derivations. Analysis, simulation and experimental results prove the superiority of the proposed technique.

Three-Phase High-Power-Density Bidirectional DC-DC Converter (3상 변압기를 이용한 고밀도 양방향 전력변환기)

  • Le, Tuan-Vu;Choi, Woo-Seok;Kim, Sun-Pil;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.45-46
    • /
    • 2014
  • This paper presents a three-phase high-power-density bidirectional DC-DC converter. The converter employs dual three-phase active bridges and a three-phase transformer. The presented converter is controlled by two symmetric PWM modules and phase between two symmetric PWM modules to control the power flow. Simulation is included to verify the presented converter.

  • PDF

Analytical Study on Effective Thermal Conductivity of Three-Phase Composites (3상 복합재의 등가열전도계수 예측에 대한 연구)

  • Lee, Jae-Kon;Kim, Jin-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.2931-2938
    • /
    • 2011
  • Effective thermal conductivity of three-phase composites, consisting of matrix and two kinds of spherical inclusions, has been derived as an explicit form by extending modified Eshelby model (MEM) for two-phase composites. The present results are compared with those by differential effective medium model (DEMM), which are also compared with the experimental results of two- and three-phase composites in the literatures to be validated. For two-phase composites, the results by MEM are better than those by DEMM for the inclusion volume fraction smaller than 0.5. Comparisons between the results by two models and experimental results have been made for three-phase composite, resulting in that MEM predicts better than DEMM for smaller volume fraction of the inclusion having larger inclusion-to-matrix thermal conductivity ratio, but DEMM predicts better as its volume fraction increases. It has been observed through parametric study that its volume fraction is the critical factor affecting the deviation of predictions by the two models. The results by them show a good agreement with the three-phase composite proposed by Molina et al..

Three-Phase Four-Wire Inverter Topology with Neutral Point Voltage Stable Module for Unbalanced Load Inhibition

  • Cai, Chunwei;An, Pufeng;Guo, Yuxing;Meng, Fangang
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1315-1324
    • /
    • 2018
  • A novel three-phase four-wire inverter topology is presented in this paper. This topology is equipped with a special capacitor balance grid without magnetic saturation. In response to unbalanced load and unequal split DC-link capacitors problems, a qusi-full-bridge DC/DC topology is applied in the balance grid. By using a high-frequency transformer, the energy transfer within the two split dc-link capacitors is realized. The novel topology makes the voltage across two split dc-link capacitors balanced so that the neutral point voltage ripple is inhibited. Under the condition of a stable neutral point voltage, the three-phase four-wire inverter can be equivalent to three independent single phase inverters. As a result, the three-phase inverter can produce symmetrical voltage waves with an unbalanced load. To avoid forward transformer magnetic saturation, the voltages of the primary and secondary windings are controlled to reverse once during each switching period. Furthermore, an improved mode chosen operating principle for this novel topology is designed and analyzed in detail. The simulated results verified the feasibility of this topology and an experimental inverter has been built to test the power quality produced by this topology. Finally, simulation results verify that the novel topology can effectively improve the inhibition of an inverter with a three-phase unbalanced load while decreasing the value of the split capacitor.

Comparison of PWM Strategies for Three-Phase Current-fed DC/DC Converters

  • Cha, Han-Ju;Choi, Soon-Ho;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.363-370
    • /
    • 2008
  • In this paper, three kinds of PWM strategies for a three-phase current-fed dc/dc converter are proposed and compared in terms of losses and voltage transfer ratio. Each PWM strategy is described graphically and their switching losses are analyzed. With the proposed PWM C strategy, one turn-off switching of each bridge switch is eliminated to reduce switching losses under the same switching frequency. In addition, RMS current through the bridge switches is lowered by using parallel connection between two bridge switches and thus, conduction losses of the switches are reduced. Further, copper losses of the transformer are decreased due to the reduced RMS current of each transformer's winding. Therefore, total losses are minimized and the efficiency of the converter is improved by using the proposed PWM C strategy. Digital signal processor (DSP: TI320LF2407) and a field-programmable gate array (FPGA: EPM7128) board are used to generate PWM patterns for three-phase bridge and clamp MOSFETs. A 500W prototype converter is built and its experimental results verify the validity of the proposed PWM strategies.

Compact Dual-Band Three-Way Metamaterial Power-Divider with a Hybrid CRLH Phase-Shift Line

  • Jang, Kyeongnam;Kahng, Sungtek;Jeon, Jinsu;Wu, Qun
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.1
    • /
    • pp.15-24
    • /
    • 2014
  • A compact dual-band three-way metamaterial power divider is proposed that has three in-phase outputs. Fully printed composite rightand left-handed (CRLH) unequal and equal power dividers are first implemented for 900-MHz and 2.4-GHz bands with the power-division ratios of 2:1 and 1:1, respectively. An initial 1:1:1 power divider is then achieved by incorporating the input of the two-way equal block into an output of the unequal block, and trimming the interconnection parameters. The condition of an identical phase at the three outputs of the power divider is then met by devising a hybrid CRLH phase-shift line to compensate for the different phase errors at the two frequencies. This scheme is confirmed by predicting the performance of the power divider with circuit analysis and full-wave simulation and measuring the fabricated prototype. They results show agreement; the in-phase outputs as well as the desirable power-division are accomplished and outdo the conventional techniques.

A STUDY ON THE REACTIVE POWER COMPENSATION OF THREE PHASE UNBALANCED LOAD FOR VAR SYSTEM (VAR 시스템에 의한 3 상 불평형 부하의 무효전력 보상에 관한 연구)

  • Jung, Yon-Taek;Seo, Young-Soo;Kim, Young-Bong;Kim, Han-Soo;Lee, Bong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.531-534
    • /
    • 1989
  • In this paper, the way that input voltage and input line current as a control variable is provided as one unit is projected. Till no, have denied with three phase balanced load. But, in that case, total power factor compensation is difficult, for to control each phase at unbalanced load. Therefor, in this paper suggest of the scheme that three phase unbalanced load is controlled by each phase and input total power factor is compensated unit input factor. therefore, in this paper suggest that three phase unbalanced load is controlled and the method in compensation of unit input factor to be attended by unbalanced load. Besides, the object of control is calculating quantity for input voltage and input line current for the point at issuse make to improve of control method at unbalanced load. As a result, control system of each phase could maintain as a unit input total power factor has been state diviation error of 2% with unbalanced load.

  • PDF

A Switching Method for Minimizing the Over Current in Transient Response of 3-phase Interleaved Bidirectional DC-DC Converter with Frequency Modulation (주파수 변조 방식 3상 인터리브드 양방향 DC-DC 컨버터의 과도상태 과전류를 최소화하기 위한 스위칭 기법)

  • Bae, Jongwoo;Jeong, Hyesoo;Jung, Jae-Hun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.530-537
    • /
    • 2016
  • This work deals with a switching method for minimizing overcurrent in a three-phase interleaved bidirectional DC-DC converter with frequency modulation. Generally, a three-phase interleaved DC-DC converter is used to reduce a current ripple component. The combined operation of three-phase and two-phase converters can significantly reduce the ripple component. However, the conventional PWM method cannot solve severe overcurrent during phase transfer or frequency variation for power control. To overcome this problem, this work proposes a new PWM switching method. A 3 kW DC-DC power converter is designed and implemented, and the converter is operated in discontinuous current mode with varying switching frequencies for power control. Simulation and experimental results show the validity of the proposed switching method. The proposed switching method can be widely used in the field of current ripple reduction for three-phase interleaved bidirectional DC-DC converters.

A Fast and Robust Grid Synchronization Algorithm of a Three-phase Converters under Unbalanced and Distorted Utility Voltages

  • Kim, Kwang-Seob;Hyun, Dong-Seok;Kim, Rae-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1101-1107
    • /
    • 2017
  • In this paper, a robust and fast grid synchronization method of a three-phase power converter is proposed. The amplitude and phase information of grid voltages are essential for power converters to be properly connected into the utility. The phase-lock-loop in synchronous reference frame has been widely adopted for the three-phase converter system since it shows a satisfactory performance under balanced grid voltages. However, power converters often operate under abnormal grid conditions, i.e. unbalanced by grid faults and frequency variations, and thus a proper active and reactive power control cannot be guaranteed. The proposed method adopts a second order generalized integrator in synchronous reference frame to detect positive sequence components under unbalanced grid voltages. The proposed method has a fast and robust performance due to its higher gain and frequency adaptive capability. Simulation and experimental results show the verification of the proposed synchronization algorithm and the effectiveness to detect positive sequence voltage.