• 제목/요약/키워드: Three-zone model

검색결과 398건 처리시간 0.023초

Effect of spatial characteristics of a weak zone on tunnel deformation behavior

  • Yoo, Chungsik
    • Geomechanics and Engineering
    • /
    • 제11권1호
    • /
    • pp.41-58
    • /
    • 2016
  • This paper focuses on the deformation behavior of tunnels crossing a weak zone in conventional tunneling. A three-dimensional finite element model was adopted that allows realistic modeling of the tunnel excavation and the support installation. Using the 3D FE model, a parametric study was conducted on a number of tunneling cases with emphasis on the spatial characteristics of the weak zone such as the strike and dip angle, and on the initial stress state. The results of the analyses were thoroughly examined so that the three-dimensional tunnel displacements at the tunnel crown and the sidewalls can be related to the spatial characteristic of the weak zone as well as the initial stress state. The results indicate that the effectiveness of the absolute displacement monitoring data as early warning indicators depends strongly on the spatial characteristics of the weak zone. It is also shown that proper interpretation of the absolute monitoring data can provide not only early warning for a weak zone outside the excavation area but also information on the orientation and the extent of the weak zone. Practical implications of the findings are discussed.

PISO 알고리즘을 이용한 세 가지 형태의 아트리움 공간에서 화재 발생시 연기 거동에 대한 수치해석적 연구 (A Numerical Study of Smoke Movement for the Three Types of Atrium Fires using PISO Algorithm)

  • 정진용;유홍선;김성찬
    • 한국화재소방학회논문지
    • /
    • 제13권1호
    • /
    • pp.21-30
    • /
    • 1999
  • 본 연구는 세 가지 유형의 아트리움 공간에 대해서 Zone 모델과 Field 모델을 비교하였으며, Zone 모델로는 FIRST, CFAST, NIST에서 개발된 CCFM.VENTS 그리고 CSIRO에서 개발된 NBTC 1-room 모델을 사용하였고 Field 모델로는 Chow에 의해 개발된 화재모델과 본 연구에서 개발된 SMEP을 사용하였다. 두 모델들에 대한 비교는 서로 유사한 결과를 보였으며, 특히 PISO 알고리즘을 사용한 SMEP의 경우가 SIMPLER 알고리즘이 적용된 field 모델에 비해 더 빠른 계산시간을 보여 주었다.

  • PDF

유한요소법 및 유사 3 차원 스트릿-타이 모델 방법을 이용한 PSC 박스거더 정착부의 해석 (Analysis of PSC Box Girder Anchorage Zone using FEM and 2D SUB-3D STM Approach)

  • 윤영묵;김승억;오진우;박정웅
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.113-129
    • /
    • 2000
  • This study evaluates the behavior and strength of an anchorage zone of the prestressed concrete box girder bridge on the Kyungboo highway railroad using the 2D SUB-3D STM approach and a linear elastic finite element analysis. The 2D SUB-3D STM approach utilizes several two-dimensional sub strut-tie models that represent the compressive and tensile stress flows of each projected plane of the three-dimensional structural concrete in the selection of a three dimensional strut-tie model, evaluation of the effective strengths of the concrete struts, and verification of the geometric compatibility condition and bearing capacity of the critical nodal zones in the selected three-dimensional strut-tie model. The finite element analysis uses an 8-node brick element and the longitudinal prestressing force is considered as the equivalent nodal force. Analysis results show that the 2D SUB-3D STM approach and linear elastic finite element method can be effectively applied to the analysis and design of three-dimensional structural concrete including a prestressed concrete box girder anchorage zone.

  • PDF

추이대(推移帶)를 중심으로 한 경상북도 3개 도시의 열섬 평가 (Evaluation of the heat island in transition zone of three cities in Kyungpook, Korea)

  • 박인환;장갑수;김종용
    • 환경영향평가
    • /
    • 제8권2호
    • /
    • pp.73-82
    • /
    • 1999
  • This study analyzed the relationship between NDVI(Normalized Difference Vegetation Index) and urban heat island in three cities: Daegu, Kyungju, and Pohang for understanding the degree of nature conservation concentrating in the transition zone of them. Daegu city is the third city in Korea which has a dense population. Kyungju is a traditional city which has good nature. Pohang is an industrial city which has those of characters of Daegu and Kyungju. Landsat 1M data in May 17, 1997 were used for the analysis of heat island. There were about four theoretical models to estimate the surface temperature from TM data: Two-point linear model, Linear regression model, Quadratic regression model, and Cubic regression model. In this study, Linear regression model had been utilized to analyze the urban heat island. On the resultant images, the transition zone of Daegu was urbanized more extremely than those of other two cities. It is thought that the analysis of relationship between NDVI and surface temperature, used in this study, is regarded as one of effective methodologies for urban-environmental detection from satellite imageries.

  • PDF

중력모형에서 존내 분포통행 예측방법에 관한 연구 (A Study on Inner Zone Trip Estimation Method in Gravity Model)

  • 유영근
    • 대한토목학회논문집
    • /
    • 제26권5D호
    • /
    • pp.763-769
    • /
    • 2006
  • 중력모형은 출발 존의 유출통행량과 도착존의 유입통행량, 그리고 출발존 중심에서 도착존 중심까지의 교통저항을 이용하여 장래 분포통행을 예측한다. 중력모형에서 존내통행 예측의 경우 교통저항이 "0"로 산정되기 때문에 중력모형에 의해 예측하지 못하고 성장율법과 같은 타 방법에 의해 예측을 행해야 하는 어려움이 존재했다. 본 연구에서는 중력모형에 의한 분포통행 예측시 구축된 중력모형을 이용하여 존내 분포통행을 예측하는 방법을 제안하였는데, 제안한 방법은 기준연도의 존내 분포통행량과 유출, 유입통행량을 존간통행에서 구축된 중력모형식에 대입하여 존내 교통저항을 산출하고 이를 다시 중력 모형에 대입하여 장래 존내 분포통행 예측을 행하는 것이다. 1988년 O-D표를 기준연도 O-D로 하고, 본 연구에서 제안한 방법과 기존의 방법인 성장률법과 회귀모형법의 1992년과 2004년 예측결과들을 실제 O-D와 $x^2$, RMSE, 상관계수 등으로 비교 분석해 본 결과, 본 연구에서 제안한 방법이 우수한 결과를 나타내었다.

A Mechanical Model of the End Anchorage Zone of Prestressed Concrete Members

  • Kang, Won-Ho;You, Young-Min;Oh, Seung-Hyun;Lee, Sang-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.35-41
    • /
    • 2006
  • It is expected that recent development of mechanical models will soon supersede previous empirical methods of detailing. In this study, a mechanical model is proposed to analyze the behavior of the anchorage zone of prestressed concrete members. The main characteristics of the proposed model lies in its rational consideration of material properties such as concrete strength in biaxial stress state and that of local zone reinforced by spirals. The shear friction strength of concrete surrounding a spiral is also considered. The computational results of the proposed model as well as the existing Strut-and-Tie model(STM) and nonlinear finite element analysis are compared with experimental results. The results of the comparison revealed that the proposed model showed better prediction of the failure mode as well as the failure load. Additionally, the proposed model also explained the three-dimensional failure mechanism very well, while other methods based on two-dimensional analysis could not do so well.

Response of lap splice of reinforcing bars confined by FRP wrapping: modeling approach

  • Thai, Dam Xuan;Pimanmas, Amorn
    • Structural Engineering and Mechanics
    • /
    • 제37권1호
    • /
    • pp.95-110
    • /
    • 2011
  • This paper presents a tri-uniform bond stress model for predicting the lap splice strength of reinforcing bar at the critical bond splitting failure. The proposed bond distribution model consists of three zones, namely, splitting zone, post-splitting zone and yielding zone. In each zone, the bond stress is assumed to be constant. The models for bond strength in each zone are adopted from previous studies. Combining the equilibrium, strain-slip relation and the bond strength model in each zone, the steel stress-slip model can be derived, which can be used in the nonlinear frame analysis of the column. The proposed model is applied to derive explicit equations for predicting the strength of the lap splice strengthened by fiber reinforced polymer (FRP) in both elastic and post-yield ranges. For design purpose, a procedure to calculate the required FRP thickness and the number of FRP sheets is also presented. A parametric investigation was conducted to study the relation between lap splice strength and lap splice length, number and thickness of FRP sheets and the ratio of concrete cover to bar diameter. The study shows that the lap splice strength can be enhanced by increasing one of these parameters: lap splice length, number or thickness of FRP sheets and concrete cover to bar diameter ratio. Verification of the model has been conducted using experimental data available in literature.

쇄파대 동력학에 대한 새로운 접근 (New Approach for Surf Zone Dynamics)

  • Lee, Jung-Lyul;Hsiang Wang
    • 한국해안해양공학회지
    • /
    • 제5권4호
    • /
    • pp.384-394
    • /
    • 1993
  • 간단한 쇄파대 모델이 제시된다. 제시된 모델은 파랑작용(wave action)이 쇄파대내에서 보존된다는 것을 입증함으로써 기존의 방법과는 아주 다른 접근방법을 택하고 있다. 파랑작용 이러한 보존법척은 파랑 에너지의 보존법칙과 함께 비교적 적은 실험상수를 필요로하는 쇄파대 모델의 개발을 가능토록하였다. 모델은 쇄파대 특성을 예상 가능케하며 2차원적인 점진적 경사에 대해서 분석적인 형태로 제시된다. 그 분석된 결과는 가능한 실험실자료와 비교하여 만족할만하였다. 이 쇄파대 모델은 수직적 흐름 모델의 수면경계에서의 흐름패턴을 제공하고 따라서 3차원적인 흐름패턴의 해를 구하는 데 상당히 기여할 것이다.

  • PDF

A simple panel zone model for linear analysis of steel moment frames

  • Saffari, Hamed;Morshedi, Esmaeil
    • Steel and Composite Structures
    • /
    • 제35권4호
    • /
    • pp.579-598
    • /
    • 2020
  • Consideration of the panel zone (PZ) deformations in the analysis of steel moment frames (SMFs) has a substantial effect on structural response. One way to include the PZ effect on the structural response is Krawinkler's PZ model, which is one of the best and conventional models. However, modeling of Krawinkler's PZ model has its complexity, and finding an alternative procedure for PZ modeling is of interest. In this study, an efficient model is proposed to simplify Krawinkler's PZ model into an Adjusted Rigid-End Zone (AREZ). In this way, the rigid-end-zone dimensions of the beam and column elements are defined through an appropriate rigid-end-zone factor. The dimensions of this region depend on the PZ stiffness, beam(s) and columns' specifications, and connection joint configuration. Thus, to obtain a relationship for the AREZ model, which yields the dimensions of the rigid-end zone, the story drift of an SMF with Krawinkler's PZ model is equalized with the story drift of the same structure with the AREZ model. Then, the degree of accuracy of the resulting relationship is examined in several connections of generic SMFs. Also, in order to demonstrate the applicability of the proposed model in SMFs, several SMFs ranging from 3- to 30-story representing low- to high-rise buildings are examined through linear static and dynamic time history analysis. Furthermore, non-linear dynamic analyses of three SMFs conducted to validate the degree of accuracy of the proposed model in the non-linear analysis of SMFs. Analytical results show that there is considerable conformity between inter-story drift ratio (IDR) results of the SMFs with Krawinkler's PZ model and those of the centerline SMFs with AREZ.

레이저 표면경화처리에서 빔의 형태에 따른 경화층 크기에 관한 연구

  • 김재웅
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 춘계학술대회 논문집
    • /
    • pp.13-17
    • /
    • 1993
  • Analytical models for the prediction of the size of hardened zone in laser surface hardening are presented. The models are based on the solutions to the problem of three-dimensional heat flow in plates with infinite thickness. The validity of the model was tested on medium carbon steel for Gaaussian mode of beam. Then the model for rectangular beam was used for the prediction of the size of harened zone on various hardening process parameters. From the calculation results it appeared that the size and shape of the hardened zone are strongly dependent on process parameters suchas beam mode, beam size, and traverse speed.