• Title/Summary/Keyword: Three-tank System

Search Result 218, Processing Time 0.035 seconds

Conceptual design and analysis of rotor for a 1-kW-Class HTS rotating machine

  • Kim, J.H.;Hyeon, C.J.;Quach, H.L.;Chae, Y.S.;Moon, J.H.;Boo, C.J.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.4
    • /
    • pp.45-50
    • /
    • 2017
  • This paper presents a conceptual design and analysis for a 1-kW-class high-temperature superconducting rotating machine (HTSRM) rotor. The designed prototype is a small-scale integration system of a HTSRM and a HTS contactless rotary excitation device (CRED). Technically, CRED and HTSRM are connected in the same shaft, and it effectively charges the HTS coils of the rotor field winding by pumping fluxes via a non-contact method. HTS coils in rotor pole body and toroidal HTS wire in CRED rotor are cooled and operated by liquid nitrogen in cryogen tank located in inner-most of rotor. Therefore, it is crucial to securely maintain the thermal stability of cryogenic environment inside rotor. Especially, we critically consider not only on mechanical characteristics of the rotor but also on cryogenic thermal characteristics. In this paper, we conduct two main tasks covering optimizing a conceptual design and performing operational characteristics. First, rotor parameters are conceptually designed by analytical design codes. These parameters consider to mechanical and thermal performances such as mechanical strength, mechanical rigidity, and thermal heat losses of the rotor. Second, mechanical and thermal characteristics of rotor for 1-kW-class HTSRM are analyzed to verify the feasible operation conditions. Hence, three-dimensional finite element analysis (3D-FEA) method is used to perform these analyses in ANSYS-Workbench platform.

Study on the Motion of Floater Structure for Design of Wave Energy Generation in Ocean (해양 파력 발전 시스템 설계를 위한 부유체 거동에 관한 연구)

  • Li, Kui Ming;Parthasarathy, Nanjundan;Park, Young-Kyu;Jung, Ho-Yun;Choi, Yoon-Hwan;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.632-639
    • /
    • 2011
  • In order to design a wave energy generate system, a 6-Degree of freedom motion analysis technique was applied to the three-Dimensional CFD analysis on two floating body and the behavior was interpreted according to the nature of the incoming wave. The waves are generated by the same type of wave in the model of tank using the piston type, but due to the shallow water that is generated from the bottom of the wave energy is attenuated by Ekman boundary layer. According to the wavelength of waves generated by the result of evaluating the behavior of floating body, it is concluded that 0.3m is the maximum amplitude of wavelength of 5m, and 0.15m is the minimum amplitude of wavelength of 1m. 1.06m is the maximum distance between the two floaters of wavelength of 6m.

ANALYSIS OF $PGE_2$ CONCENTRATION IN SYNOVIAL FLUID ASPIRATES FROM TMJS OF PATIENTS WITH MANDIBULAR FRACTURE (하악골절 환자에서 악관절강내 활액의 $PGE_2$ 농도 분석)

  • Lee, Gi-Hyug;Kim, Su-Gwan;Kim, Myung-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.204-208
    • /
    • 2001
  • The purpose of this study is to examine the change of enzymeimmuno-assay for $prostaglandinE_2$ in the synovial fluid lavage specimen of patients with mandibular fracture patients without condylar fracture. For this study, fourteen patients (eight males, six females) with mandibular fractures without condylar fracture was investigated to analyse the synovial fluid from upper temporomandibular joint cavities. Synovial fluid was collected from TMJ cavities of mandibular fracture patients before open reduction and after one week of open reduction, and then stored in liquid nitrogen tank after centrifuge. Two synovial fluid lavage samples of TMJs of 2 asymptomatic served as normal controls referred from other data. The concentrations of $PGE_2$ were measured by use of $PGE_2$ EIA System ($Amersham^{(R)}$). The following results were obtained: 1) In nine patients, the concentrations of $PGE_2$ are lower after open reduction than before. 2) In three patients, the concentrations of $PGE_2$ are higher after open reduction than before. 3) There was no statistical significant between the preoperative group and postoperative 7 days (p>0.05), but there was some difference between the two groups. In conclusion, the results suggest that $PGE_2$ probably does not play as important role in the harm of TMJ.

  • PDF

Analysis of Dominant Microorganisms of Bulking Sludge at Low Dissolved Oxygen Concentration using 16S rRNA Sequences (16S rRNA 염기서열을 이용한 낮은 용존산소농도에서 발생한 벌킹슬러지의 우점종 분석)

  • Kim, Yun-Jung;Park, Eun-Hye;Kim, Gyu-Dong;Nam, Kyoungphile;Chung, Tai Hak
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.506-511
    • /
    • 2004
  • Maintaining dissolved oxygen (DO) at sufficiently low concentration in the aeration tank at a wastewater treatment plant (WWTP) is essential for reduction of the costs of operation and maintenance. On the other hand, the low DO level may result in adverse effect on the integrity of the activated sludge, A typical and disastrous outcome frequently experienced is the outgrowth of filamentous microorganisms, which is called as filamentous bulking, In addition to the traditional methods such as sludge settleability and microscopic observation of the culture, molecular techniques including polymerase chain reaction (PCR) amplification followed by 16S rRNA sequencing were applied to identify filamentous bacteria present in bulking sludge under a condition of low DO concentration, Two morphologically distinct groups, presumably consisting of Sphaerofilus nafans, and Eikelboom Type 1701 or Type 1851, were identified through microscopic observation. They were further confirmed by subsequent 16S rRNA sequencing. Dominant filamentous bacteria identified by the molecular techniques were consisted of three major groups. Sequences of partial 16S rRNA cloned showed that the filamentous bulking organisms were closely related to Eikelboom Type 021N and Eikelboom Type 1701, and Sphaerotilus natans, respectively. Molecular methods were found to possess a strong potential of direct examination of the microbial community of an activated sludge system.

Effect of Dye-Degrading Microbes' Augmentation on Microbial Ecosystem of the Fluidizing Media and Color Treatment in a Pilot Plant (염료 분해균 증대를 통한 Pilot Plant에서의 담체 내 미생물 생태와 색도처리에 미치는 영향)

  • Kim, Jung-Tae;Lee, Geon;Park, Do-Hyeon;Kang, Kyeong-Hwan;Kim, Joong-Kyun;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.681-695
    • /
    • 2014
  • In a pilot-scale dyeing wastewater treatment using two-type fluidizing media, each thickness of biofilm was 15 and 30 ${\mu}m$, respectively. The numbers of protozoa inhabited in small-size (PEMT A) and big-size (PEMT B) media were $7.5{\times}10^4$ and $1.25{\times}10^5$ cells/ml, respectively, and dominant species were Entosiphon sulcatus var sulcatus in PEMT A and Chlamydomonas reinhardtii in PEMT B, respectively. Flask experiments using the two media revealed that the percentages of color removal were 25.8% in PEMT A and 27.1% in PEMT B after 72-h cultivation, indicating the necessity of bioaugmentation. Experiments for bioaugmentation effect on color removal were carried out in the pilot-scale treatment for 75 d by three-step operation under the control of wastewater loading rate and microbial input rate. Dye degradation occurred mainly in the second reaction tank, and the attachment of augmented dye-degrading microorganisms to media took at least 35 d. Final value of chromaticity in effluent was 227, meeting the required standard. Therefore bioaugmentation onto media was good for color treatment. In summary, thickness of biofilm formed on the media depended upon the size of media, resulting in different ecosystem inside the media. Hence, this affected microbial community and color treatment further. Accordingly, the reduction of operation cost is expected by efficient color-treatment process using bioaugmented media.

Design and Optimization of Vibration-resistant and Heat-insulating Support Structure of Fuel Cylinder for LNG Vehicles (차량용 LNG 연료 용기의 내진동 단열지지구조 설계 및 최적화)

  • Kwon, Hyun-Wook;Hwang, In-Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.6-11
    • /
    • 2014
  • To optimize the design of fuel cylinder for LNG vehicles, we introduced the design parameters of the inner and the outer tank of the vessel support structure by analyzing the structural characteristics of conventional design. We selected the inner and outer diameter of the hollow support bars and a dimension of the inner structure of the vessel among the design parameters for design optimization. In this study the temperature distribution and thermal stress of the support structure were evaluated by using the utility program as MSC/MARC. The evaluation criteria are first mode natural frequency, total transferred energy through support structure and thermal stress. The developed design satisfied the design criteria and it was made of prototype. The prototype was verified through three-dimensional vibration testing and thermal performance test.

A Study on Worker Exposure to Ethylene Oxide in Central Supply Sterilizing Room of Hospital (일부 종합병원 중앙공급실에서의 Ethylene Oxide 노출에 관한 연구)

  • Seo, Sang Ok;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.68-86
    • /
    • 1995
  • This study was conducted at five Ethylene Oxide(EO) sterilizing processes in hospitals located in Seoul from August 8 to August 30, 1994. The main purposes of this study were to assess the TWA(Time Weighted Average) and short term exposures to EO and to evaluate factors affecting EO concentrations in sterilizing room. Results are summarized as follows. 1. The TWA concentrations of the sterilizing operators ranged from <0.005ppm to 3.04ppm and those of two sterilizing rooms out of five exceeded 1ppm, the Korean and ACGIH standards. 2. When the door of the sterilizer is opened at the end of the sterilization cycle, the short term concentrations of operators ranged from <0.005ppm to 11.4ppm, and those of three sterilizing room out of five exceeded 5ppm, the ACGIH short term exposure limit(STEL). The short term concentrations of area samples ranged from 0.24ppm to 49.2ppm and those of four sterilizing room out of five exceeded 5ppm. 3. Factors affecting EO exposure level were aeration type, the location of storage site for sterilized item, amount of gas, use period of sterilizer(p<0.005). 4. Following recommendations are suggested to minimize exposure to EO. The use of EO gas should be reduced by using another available sterilization methods, and the sterilizers and gas tank storage site should be isolated from, other work areas. Combination of local and general ventilation system should be installed. Metal carts or baskets for sterilization load should be used, and work environment and medical monitoring should be performed regularly.

  • PDF

Optimization of water intake scheduling based on linear programming (선형계획법을 이용한 정수장 취수계획 최적화)

  • Jeong, Gimoon;Lee, Indoe;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.8
    • /
    • pp.565-573
    • /
    • 2019
  • An optimization model of water intake planning is developed based on a linear programming (LP) for the intelligent water purification plant operation system. The proposed optimization model minimizes the water treatment costs of raw water purification by considering a time-delay of treatment process and hourly electricity tariff, which is subject to various operation constraints, such as water intake limit, storage tank capacity, and water demand forecasts. For demonstration, the developed model is applied to H water purification center. Here, we have tested three optimization strategies and the results are compared and analyzed in economic and safety aspects. The optimization model is expected to be used as a decision support tool for optimal water intake scheduling of domestic water purification centers.

An Experimental Study of Wave Overtopping Characteristics on the Structure for Wave Overtopping Power Generating System (월파형 파력발전구조물의 월파 특성에 관한 실험적 연구)

  • Shin, Seung-Ho;Hong, Key-Yong
    • Journal of Navigation and Port Research
    • /
    • v.30 no.8 s.114
    • /
    • pp.649-655
    • /
    • 2006
  • Waves progressing into the coastal area can be amplified, swashed and overtopped by a wave overtopping control structure, and it converts the kinetic energy of the waves to the potential energy with a hydraulic head above the mean sea level by conserving the overflow in a reservoir. Then the potential energy in the form of hydraulic head can be converted to electric power utilizing extremely low-head hydraulic turbine. This study aims to find the most optimal shape of wave overtopping structure which maximizes overtopping volume rate of sea water. Laboratory experiments for the performance evaluation of wave overtopping control structures were carried out in three dimensional wave tank, and the three dimensional structure models with planar wave concentration shapes(B/b) were manufactured into five classes, which were optimized by cross sectional parameters of the structure, ie, length of ramp(l), gradient of inclined ramp($cot{\phi}$) and freeboard height of the wave overtopping structure($h_e$) proposed by Shin and Hong(2005). The wave overtopping discharges were investigated with 20 incident wave conditions and wave directions of $0^{\circ},\;15^{\circ},\;30^{\circ}$.

The Effect of Media Application in Aeration Tank for Aerobic Treatment of Swine Slurry (돈분뇨슬러리 폭기시 담체 설치효과)

  • Jeong, Kwang-Hwa;Choi, S.H.;Kwag, J.H.;Kim, J.H.;Jeong, E,S.;Jeong, M,S.;Kang, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.167-174
    • /
    • 2010
  • This study was performed to evaluate the removal effects of nutritive salts and organic pollutants in experimental aeration reactor for treatment of piggery slurry. In this study, three types of reactors were manufactured and operated. The fibrous media was equipped in one of three reactors. Another reactor was equipped with the siliceous media and the other reactor used as a control was equipped with typical aeration system only. Treatment efficacy of three types of reactors were evaluated according to the pollutants removal rate of the piggery slurry. The results obtained in this study are as follows : 1) In the reactor containing fibrous media, the removal efficiency of BOD, T-N and T-P was 11%, 13.9% and 21.2%, respectively. 2) In the reactor containing siliceous media, the removal efficiency of BOD, T-N and T-P was 6.9%, 25.3% and 47.8%, respectively. 3) In the reactor not containing media, the removal efficiency of BOD. T-N and T-P was 6.1%, 8.1.% and 23.6%, respectively. 4) Sludge accumulation in the reactor equipped with filamentous media was lower than that of other experimental reactors.