• Title/Summary/Keyword: Three-input

Search Result 2,930, Processing Time 0.029 seconds

SVPWM controlled the Three-phase AC to DC Boost Converter for High Power Factor (SVPWM 방식의 3상 고역율 AC-DC Boost 컨버터)

  • Na, Jae-Hyeong;Lee, Jung-Hyo;Kim, Kyung-Min;Lee, Su-Won;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.327-331
    • /
    • 2008
  • The problems of power factor and harmonics are occurred in converter system which used to SCRs and diodes as power semiconductor devices IGBT was solved that problem, maintain the input line current with sinusoidal wave current of input power source voltage. In this paper, three phase AC to DC boost converter that operates with unity power factor and sinusoidal input currents is presented. The current control of the converter is based on the space vector PWM strategy with fixed switching frequency and the input current tracks the reference current within one sampling time interval. Space vector PWM strategy for current control was materialized as a digital control method. By using this control strategy low ripples in the output voltage, low harmonics in the input current and fast dynamic responses are achieved with a small capacitance in the dc link.

  • PDF

Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage (전원전압과 DC-link 전압 추정을 통한 3상 컨버터 센서리스 제어)

  • Chu, Hung-Seok;Park, Sung-Jun;Kim, Kwong-Tae;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1233-1235
    • /
    • 2000
  • A new control method of three phase converter without measuring input phase-voltage and DC-link voltage is proposed. Input phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In addition, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF

Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage (전원전압과 DC-link 전압 추정에 의한 3상 컨버터 센서리스 제어)

  • Chu Hung-Seok;Cheon Chang-Gun;Ahn Jin-Woo;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.227-230
    • /
    • 2001
  • A new control method of three phase converter without measuring input Phase-voltage and DC-link voltage is Proposed. Input Phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In additon, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF

Reduction of Input Current Harmonics for Three Phase PWM Converter Systems under a Distorted Utility Voltage

  • Park, Nae-Chun;Mok, Hyung-Soo;Kim, Sang-Hoon
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.428-433
    • /
    • 2010
  • This paper proposes a harmonics reduction technique for the input currents of three phase PWM converters. The quality of the phase angle information on the utility voltage connected to the PWM converters affects their control performance. Under a distorted utility voltage, the extracted phase angle based on the synchronous reference frame PLL method is distorted. This causes large harmonics in the input currents of a PWM converter. In this paper, a harmonics reduction method that makes the input currents in the PWM converter sinusoidal even under distorted utility conditions is proposed. By the proposed method, without additional hardware, the THD (Total Harmonic Distortion) of the input currents can be readily limited to below 5% which is the harmonic current requirements of IEEE std. 519. Its validity is verified by simulations and experimental results.

"Least Gain or Wrist Pain": A comparative study about performance and usability of mouse, trackball, and touchpad

  • Yunsun Alice Hong;Kwanghee Han
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.2
    • /
    • pp.298-309
    • /
    • 2023
  • The mouse as an input device has undoubtedly brought convenience to users due to its intuitiveness and simplicity, but it also brought unprecedented issues such as carpal tunnel syndrome (CTS). As a result, the necessity of alternative input devices that put less strain on the wrist, while still providing the convenience of a conventional mouse, has emerged. Unfortunately, there have been several research about alternative devices to replace a mouse, however, they showed inconsistent results. This study suggests that those inconsistent results may stem from the type and the difficulty of tasks used in previous studies. Therefore, we designed this study to compare the performance and perceived workload of three input devices (Mouse/Trackball/Touchpad) in each condition in terms of task type (Targeting/Tracking) and difficulty level (Easy/Hard). The results indicated that there were significant performance differences and no significant workload differences among the three devices, and the interactions were observed in some conditions. These results can provide users with practical guidelines to choose the optimal input device according to their needs or purpose.

Harmonic Reduction in Three-Phase Boost Converter with Sixth Order Harmonic Injected PWM (6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감)

  • 이정호;김재문;이정훈;원충연;김영석;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.176-183
    • /
    • 2000
  • In this paper, sixth order hannonic injected PWM for improving‘ input CWTent distortion of single switch t three phase boost converter is presented. Peliodic sixth order hmmonic ${\gamma}$oltage is inj<:ded in the control circuit t to var${\gamma}$ the duty ratio of the converter switch within one switching cycle. In the result, the input phase c currents are forced to track the input voltage and an 해most unity power factor is obtained. Expelimental r results are verified by converter operating at 400V /6kW with three phase 140V ~220V input and by C02 arc w welding machine which was nonlinear load with 3 $\phi$ 220V input.

  • PDF

Double Line Voltage Synthesis Strategy for Three-to-Five Phase Direct Matrix Converters

  • Wang, Rutian;Zhao, Yanfeng;Mu, Xingjun;Wang, Weiquan
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.81-91
    • /
    • 2018
  • This paper proposes a double line voltage synthesis (DLVS) strategy for three-to-five phase direct matrix converters. In the proposed strategy, the input and expected output voltages are divided into 6 segments and 10 segments, respectively. In addition, in order to obtain the maximum voltage transfer ratio (VTR), the input line voltages and "source key" should be selected reasonably according to different combinations of input and output segments. Then, the corresponding duty ratios are calculated to determine the switch sequences in different segment combinations. The output voltages and currents are still sinusoidal and symmetrical with little lower order harmonics under unbalanced or distorted input voltages by using this strategy. In addition, the common mode voltage (CMV) can be suppressed by rearranging some of the switching states. This strategy is analyzed and studied by a simulation model established in MATLAB/Simulink and an experimental platform, which is controlled by a DSP and FPGA. Simulation and experimental results verify the feasibility and validity of the proposed DLVS strategy.

Three-Port Converters with a Flexible Power Flow for Integrating PV and Energy Storage into a DC Bus

  • Cheng, Tian;Lu, Dylan Dah-Chuan
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1433-1444
    • /
    • 2017
  • A family of non-isolated DC-DC three-port converters (TPCs) that allows for a more flexible power flow among a renewable energy source, an energy storage device and a current-reversible DC bus is introduced. Most of the reported non-isolated topologies in this area consider only a power consuming load. However, for applications such as hybrid-electric vehicle braking systems and DC microgrids, the load power generating capability should also be considered. The proposed three-port family consists of one unidirectional port and two bi-directional ports. Hence, they are well-suited for photovoltaic (PV)-battery-DC bus systems from the power flow viewpoint. Three-port converters are derived by combining different commonly known power converters in an integrated manner while considering the voltage polarity, voltage levels among the ports and the overall voltage conversion ratio. The derived converter topologies are able to allow for seven different modes of operation among the sources and load. A three-port converter which integrates a boost converter with a buck converter is used as a design example. Extensions of these topologies by combining the soft-switching technique with the proposed design example are also presented. Experiment results are given to verify the proposed three-port converter family and its analysis.

A Novel Three Level DC/DC Converter for High power applications operating from High Input Voltage (대용량 및 높은 입력전압에 적합한 새로운 Three Level DC/DC 컨버터)

  • Han S.K.;Oh W.S.;Moon G.W.;Youn M.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.317-322
    • /
    • 2003
  • A novel three-level DC/DC converter (TLC)for high power applications operating from high input voltage Is proposed. Its switch voltage stress can be ensured to be only one-half of the Input voltage. Nevertheless, since all input voltage is applied to the transformer primary side, it has good turns ratio. The driving method of each module is same as those of the conventional phase-shifted ZVS full bridge PWM converter (PSFB) and the zero-voltage-switching (ZVS) of the leading leg are achieved exactly in the same manner as that of the PSFB. Moreover, its three-level operation can considerably reduce the current ripple through the output inductor and it has no problems of the DC-link voltage unbalance. Therefore, it features a low voltage stress, high efficiency, low EMI, high power density, and small sized filter. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 200W, 600V/DC-48V/DC prototype are presented.

  • PDF

Output Voltage Control of Z-Source Inverter by the Detection of the Input DC Voltage and Z-Network Capacitor Voltage (입력 직류 전압과 Z-네트워크 커패시터 전압 검출에 의한 Z-소스 인버터의 출력 전압 제어)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1515-1522
    • /
    • 2011
  • This paper proposes the algorithm for the output AC voltage control of Z-source inverter by the detection of the input DC voltage and Z-network capacitor voltage. The actual modulation index of the proposed method is detected by the capacitor voltage in Z-network and input DC voltage of three-phase Z-source inverter. Control modulation index for the output voltage control is calculated by the detected actual modulation index and reference modulation index. And, calculated control modulation index is applied to the modified space vector modulation (SVM) for control the output voltage of Z-source inverter. To verify the validity of the proposed method, PSIM simulation was achieved and a DSP controlled 1[kW] three-phase Z-source inverter was producted. The simulation and experiment were performed under the condition that the load was changed in case of the constant input DC voltage and the input DC voltage was changed in case of the load was constant. As a result, we could know that the output phase voltage of Z-source inverter followed to the reference voltage 70[VRMS] despite the load or the input DC voltage were suddenly changed.