• Title/Summary/Keyword: Three-dimensional anthropometric measurement

Search Result 17, Processing Time 0.024 seconds

Classification and Characteristics of Neck-base Shape of Korean Females in Their Twenties (20대 여성의 목밑둘레 형태 유형화 및 특징)

  • Hwang Keun Young;Nam Yun Ja;Park Jae Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.3_4 s.141
    • /
    • pp.502-510
    • /
    • 2005
  • The purpose of this study is to identify neck shapes of women by classifying their neck-base types according to the shapes of neck and analyzing the characteristics of each type. The subjects were 58 women $18\~24$ years of age. Their body were measured directly and indirectly by using camera, 3-dimensional body scanner. The anthropometric measurements were composed of 17 items. They were measured during the months of October in 2001 The results and discussions of this study are as follows. There were three kinds of neck-base type. The first type was slant from the back neck-base to the side neck-base, and slant from the side neck-base to the front neck-base. The second type was gentle from the back neck-base to the side neck-base, and gentle from the side nect-base to the front neck-base. finally, the third type was gentle from the back neck-base to the side neck-base, and slant from the side neck-base to the front neck-base. Hopefully, understanding the shapes of neck and characteristics of each neck-base type will help to suggest computer assisted neck-base's landmark identification algorithms and measurement extraction methods from three-dimensional body scan data.

Comparison of the 3D Digital Photogrammetry and Direct Anthropometry in Unilateral Cleft Lip Patients (일측성 구순열 환자에서 3차원 수치사진측량 스캔과 직접계측 방법의 비교)

  • Seok, Hyo Hyun;Kwon, Geun-Yong;Baek, Seung-Hak;Choi, Tae Hyun;Kim, Sukwha
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • Background: In cleft lip patients, the necessity of a thorough preoperative analysis of facial deformities before reconstruction is unquestioned. The surgical plan of cleft lip patient is based on the information gained from our preoperative anthropometric evaluation. A variety of commercially available three-dimensional (3D) surface imaging systems are currently introduced to us in plastic surgery for these use. However, few studies have been published on the soft tissue morphology of unrepaired cleft infants described by these 3D surface imaging systems. Methods: The purpose of this study is to determine the accuracy of facial anthropometric measurements obtained through digital 3D photogrammetry and to compare with direct anthropometry for measurement in unilateral cleft lip patients. We compared our patients with three measurements of dimension made on both sides: heminasal width, labial height, and transverse lip length. Results: The preoperative measurements were not significantly different in both side of labial height and left side of heminasal width. Statistically significant differences were found on both side of transverse lip length and right side of heminasal width. Although the half of preoperative measurements were significantly different, trends of results showed average results were comparable. Conclusion: This is the first study in Korea to simultaneously compare digital 3D photogrammetry with traditional direct anthropometry in unilateral cleft lip patients. We desire this study could contribute the methodological choice of the many researchers for proper surgical planning in cleft lip reconstruction field.

Analyzing Adult Male Hand Shape for the Development of Work Gloves (작업용 장갑 개발을 위한 성인 남성 손 형태 분석)

  • Sujoung Cha
    • Journal of Fashion Business
    • /
    • v.27 no.4
    • /
    • pp.21-37
    • /
    • 2023
  • This study aimed to classify the hand types of adult males aged 20 to 69 years using three-dimensional measurement data from the 2020 8th Korean Anthropometric Survey, the latest measurement data from the National Institute of Standards and Technology Size Korea, and explore the characteristics of each type. Through this, I aimed to draw implications for the development of work gloves. The factors that make up an adult male's hand were categorized into hand and finger thickness factors, palm length factors, and finger length factors. Adult male hands were categorized into four types: small, thin hands and long fingers; thick, long fingers; medium, short hands and fingers; and large, thin, short fingers. The analysis showed that the younger the age, the more slender and long the hands and fingers, and as age increased, hands and fingers became shorter and thicker. Implications for the development of work gloves included the need for size segmentation based on the age of the work glove user, changes in the way glove dimensions are set based on hand length and hand circumference, and the need to segment gloves by the type of work. Hand typing in future research should be done according to occupational groups, and glove patterns should be developed for each type of work based on the results of this study.

New Breast Measurement Technique and Bra Sizing System Based on 3D Body Scan Data

  • Oh, Seolyoung;Chun, Jongsuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.4
    • /
    • pp.299-311
    • /
    • 2014
  • Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.

Anthropometric analysis of the eyeball exposure area in Koreans

  • Park, Ki Soo;Ka, Soon Il;Park, Dae Hwan
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.9-14
    • /
    • 2020
  • Background Eyelids vary in morphology and structure depending on age, sex, and race. Usually, one-dimensional measurements are used to evaluate blepharoplasty outcomes. However, in recent years, three- or four- directional enlargements of the eyelid have been used for blepharoplasty in Asian patients, and the outcomes of techniques such as lateral canthoplasty or canthotomy and medial epicanthoplasty with increased scleral area cannot be analyzed using marginal reflex distance 1 or the area of corneal exposure. Therefore, we describe the use of a measurement method based on the eyeball exposure area (EEA). Methods To obtain normal EEA values by age and sex, 320 individuals were recruited. The participants were divided into eight age groups (n=40 in each group: female subjects, n=20; male subjects, n=20): 10-19, 20-29, 30-39, 40-49, 50-59, 60-69, 70-79, and 80-89 years. The EEA value was obtained by dividing the exposed area by the total eyeball area. The normal EEA values and differences in EEA according to age and sex were calculated. Results The mean EEA values for male and female subjects were 66.86% ±9.20% and 71.48%±10.48%, respectively. In each age group, the EEA values of females were higher than those of males. EEA decreased significantly with age in both male and female subjects (P<0.05). Conclusions We determined normal EEA values according to age and sex. EEA can be used as an indicator of the outcome of blepharoplasty.

HRTF Measurement and Its Application for 3-D Soung Localization

  • Kang, Kyeong Ok;Kang, Dong-Gyu;Hahn, Minsoo;Jho, Moon Jae;Jeong, Dae-Gwon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3E
    • /
    • pp.50-55
    • /
    • 1997
  • Based on the anthropometric data of Korea male adults, a head and torso simulator(HATS) is constructed to measure its head related transfer functions (HRTFs) which can be used for three dimensional (3-D) sound localization. The HRTFs binaural impulse responses, are measured in an anechoic chamber using a burst maximum length sequence (MLS) signal of 65,535 samples and 32,768 samples acquisition at the sampling rate of 75.47kHz. Also measured are the impulse responses of a driving loudspeaker and some headphones for sound reproduction to get the exact HRTF of the HATS-alone. Through a post-processing procedure, the impulse-version HRTFs at the sampling frequency of 44.1 kHz, which have filter lengths of 512 points, are finally obtained. As an application of the measured HRTFs, a 3-D sound processor for headphone reproduction has been developed. The signal intervals to be processed can be selected and each interval is manipulated to have its diretionality and distance information by using corresponding HRTF and energy control.

  • PDF

Upper Body Surface Change Analysis using 3-D Body Scanner (3차원 인체 측정기를 이용한 체표변화 분석)

  • Lee Jeongran;Ashdoon Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1595-1607
    • /
    • 2005
  • Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.