• 제목/요약/키워드: Three-dimensional anthropometric measurement

검색결과 17건 처리시간 0.026초

20대 여성의 목밑둘레 형태 유형화 및 특징 (Classification and Characteristics of Neck-base Shape of Korean Females in Their Twenties)

  • 황근영;남윤자;박재경
    • 한국의류학회지
    • /
    • 제29권3_4호
    • /
    • pp.502-510
    • /
    • 2005
  • The purpose of this study is to identify neck shapes of women by classifying their neck-base types according to the shapes of neck and analyzing the characteristics of each type. The subjects were 58 women $18\~24$ years of age. Their body were measured directly and indirectly by using camera, 3-dimensional body scanner. The anthropometric measurements were composed of 17 items. They were measured during the months of October in 2001 The results and discussions of this study are as follows. There were three kinds of neck-base type. The first type was slant from the back neck-base to the side neck-base, and slant from the side neck-base to the front neck-base. The second type was gentle from the back neck-base to the side neck-base, and gentle from the side nect-base to the front neck-base. finally, the third type was gentle from the back neck-base to the side neck-base, and slant from the side neck-base to the front neck-base. Hopefully, understanding the shapes of neck and characteristics of each neck-base type will help to suggest computer assisted neck-base's landmark identification algorithms and measurement extraction methods from three-dimensional body scan data.

일측성 구순열 환자에서 3차원 수치사진측량 스캔과 직접계측 방법의 비교 (Comparison of the 3D Digital Photogrammetry and Direct Anthropometry in Unilateral Cleft Lip Patients)

  • 석효현;권근용;백승학;최태현;김석화
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.11-15
    • /
    • 2013
  • Background: In cleft lip patients, the necessity of a thorough preoperative analysis of facial deformities before reconstruction is unquestioned. The surgical plan of cleft lip patient is based on the information gained from our preoperative anthropometric evaluation. A variety of commercially available three-dimensional (3D) surface imaging systems are currently introduced to us in plastic surgery for these use. However, few studies have been published on the soft tissue morphology of unrepaired cleft infants described by these 3D surface imaging systems. Methods: The purpose of this study is to determine the accuracy of facial anthropometric measurements obtained through digital 3D photogrammetry and to compare with direct anthropometry for measurement in unilateral cleft lip patients. We compared our patients with three measurements of dimension made on both sides: heminasal width, labial height, and transverse lip length. Results: The preoperative measurements were not significantly different in both side of labial height and left side of heminasal width. Statistically significant differences were found on both side of transverse lip length and right side of heminasal width. Although the half of preoperative measurements were significantly different, trends of results showed average results were comparable. Conclusion: This is the first study in Korea to simultaneously compare digital 3D photogrammetry with traditional direct anthropometry in unilateral cleft lip patients. We desire this study could contribute the methodological choice of the many researchers for proper surgical planning in cleft lip reconstruction field.

작업용 장갑 개발을 위한 성인 남성 손 형태 분석 (Analyzing Adult Male Hand Shape for the Development of Work Gloves)

  • 차수정
    • 패션비즈니스
    • /
    • 제27권4호
    • /
    • pp.21-37
    • /
    • 2023
  • This study aimed to classify the hand types of adult males aged 20 to 69 years using three-dimensional measurement data from the 2020 8th Korean Anthropometric Survey, the latest measurement data from the National Institute of Standards and Technology Size Korea, and explore the characteristics of each type. Through this, I aimed to draw implications for the development of work gloves. The factors that make up an adult male's hand were categorized into hand and finger thickness factors, palm length factors, and finger length factors. Adult male hands were categorized into four types: small, thin hands and long fingers; thick, long fingers; medium, short hands and fingers; and large, thin, short fingers. The analysis showed that the younger the age, the more slender and long the hands and fingers, and as age increased, hands and fingers became shorter and thicker. Implications for the development of work gloves included the need for size segmentation based on the age of the work glove user, changes in the way glove dimensions are set based on hand length and hand circumference, and the need to segment gloves by the type of work. Hand typing in future research should be done according to occupational groups, and glove patterns should be developed for each type of work based on the results of this study.

New Breast Measurement Technique and Bra Sizing System Based on 3D Body Scan Data

  • Oh, Seolyoung;Chun, Jongsuk
    • 대한인간공학회지
    • /
    • 제33권4호
    • /
    • pp.299-311
    • /
    • 2014
  • Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.

Anthropometric analysis of the eyeball exposure area in Koreans

  • Park, Ki Soo;Ka, Soon Il;Park, Dae Hwan
    • Archives of Plastic Surgery
    • /
    • 제47권1호
    • /
    • pp.9-14
    • /
    • 2020
  • Background Eyelids vary in morphology and structure depending on age, sex, and race. Usually, one-dimensional measurements are used to evaluate blepharoplasty outcomes. However, in recent years, three- or four- directional enlargements of the eyelid have been used for blepharoplasty in Asian patients, and the outcomes of techniques such as lateral canthoplasty or canthotomy and medial epicanthoplasty with increased scleral area cannot be analyzed using marginal reflex distance 1 or the area of corneal exposure. Therefore, we describe the use of a measurement method based on the eyeball exposure area (EEA). Methods To obtain normal EEA values by age and sex, 320 individuals were recruited. The participants were divided into eight age groups (n=40 in each group: female subjects, n=20; male subjects, n=20): 10-19, 20-29, 30-39, 40-49, 50-59, 60-69, 70-79, and 80-89 years. The EEA value was obtained by dividing the exposed area by the total eyeball area. The normal EEA values and differences in EEA according to age and sex were calculated. Results The mean EEA values for male and female subjects were 66.86% ±9.20% and 71.48%±10.48%, respectively. In each age group, the EEA values of females were higher than those of males. EEA decreased significantly with age in both male and female subjects (P<0.05). Conclusions We determined normal EEA values according to age and sex. EEA can be used as an indicator of the outcome of blepharoplasty.

HRTF Measurement and Its Application for 3-D Soung Localization

  • Kang, Kyeong Ok;Kang, Dong-Gyu;Hahn, Minsoo;Jho, Moon Jae;Jeong, Dae-Gwon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제16권3E호
    • /
    • pp.50-55
    • /
    • 1997
  • Based on the anthropometric data of Korea male adults, a head and torso simulator(HATS) is constructed to measure its head related transfer functions (HRTFs) which can be used for three dimensional (3-D) sound localization. The HRTFs binaural impulse responses, are measured in an anechoic chamber using a burst maximum length sequence (MLS) signal of 65,535 samples and 32,768 samples acquisition at the sampling rate of 75.47kHz. Also measured are the impulse responses of a driving loudspeaker and some headphones for sound reproduction to get the exact HRTF of the HATS-alone. Through a post-processing procedure, the impulse-version HRTFs at the sampling frequency of 44.1 kHz, which have filter lengths of 512 points, are finally obtained. As an application of the measured HRTFs, a 3-D sound processor for headphone reproduction has been developed. The signal intervals to be processed can be selected and each interval is manipulated to have its diretionality and distance information by using corresponding HRTF and energy control.

  • PDF

3차원 인체 측정기를 이용한 체표변화 분석 (Upper Body Surface Change Analysis using 3-D Body Scanner)

  • 이정란
    • 한국의류학회지
    • /
    • 제29권12호
    • /
    • pp.1595-1607
    • /
    • 2005
  • 3차원 스캐너를 통한 인체 측정치는 다양한 분야에서 사용되고 있다. 본 연구는 이러한 3차원 측정치의 정확성과 신뢰도를 조사하기 위한 것이다. 이를 위해 TECMATH사의 VITUS 전신 스캐너로 인체를 측정, ScanWorX Body Measure 소프트웨어를 이용하여 항목을 측정 한 값과 직접 인체측정 에 의해 얻어진 값을 비교하였다. 피험자는 평균 체형의 미국 여대생 25명이며 기준 자세와 일상생활에 많이 쓰이는 $135^{\circ}$ 양팔들기, 어깨 구부리기, 어깨 들어올리기의 3가지 동적 자세를 실험 동작으로 하여 체표의 길이 및 둘레의 변화를 측정하였다. 기준 자세와 135"양팔 들기에 대한 측정치 비교에서 두 가지 측정법에 의한 항목들의 차이는 $-2\~20mm$였으나 두 동작 모두에서 목둘레만이 유의한 차이가 있는 것으로 나타났다. 또한 길이항목보다 둘레항목에서 좀 더 큰 차이를 보였다. 실험 동작에 의해 상반신 18개의 측정항목들은 유의한 체표변화를 나타내었으며 특히 어깨길이, 겨드랑앞벽사이길이, 겨드랑뒤벽사이길이 그리고 견봉사이길이에서 뚜렷한 변화가 나타났다. 그러나 두 측정 법에 따른 체표변화 차이는 없었다. 어깨 구부리기와 어깨 들어올리기 동작시에는 스캔 측정을 3회 반복함으로써 3차원 측정치의 신뢰도를 조사하였는데 모든 항목에서 3회 반복된 측정치가 통계적으로 동일한 것으로 나타났다. 또한 ScanWorX소프트웨어의 가상적 도구인 Body Measure와 자동 프로그램인 ScanWorX Tailor의 측정치를 비교한 결과 자동 측정치가 더 큰 값을 보였고 사용한 프로그램에 따른 유의한 차이를 나타내는 항목들이 나타났다. 이상의 결과로 3차원 인체 측정기를 사용함으로써 짧은 시간에 동작을 촬영하고 이에 대한 측정치를 얻을 수 있어 편리함과 신뢰도에 있어서 장점을 가짐을 확인할 수 있었다. 그러나 좀 더 다양한 분석과 정확한 결과를 얻기 위해서는 의복 분야에 유용한 자동 프로그램의 개발과 3차원 인체 측정기간의 호환성의 문제들이 요구된다고 할 수 있다.