• Title/Summary/Keyword: Three-dimensional Reconstruction

Search Result 462, Processing Time 0.027 seconds

One injection for a great projection: a quick and simple procedure for nipple reconstruction

  • Tanini, Sara;Calabrese, Sara;Lucattelli, Elena;Russo, Giulia Lo
    • Archives of Plastic Surgery
    • /
    • v.48 no.2
    • /
    • pp.179-184
    • /
    • 2021
  • Women attach great importance to the presence of a three-dimensional nipple upon completion of the breast reconstruction process. To meet patients' expectations, nipple-areolar complex reconstruction should achieve symmetry in position, size, shape, texture, and color, as well as minimizing donor-site morbidity. However, it is well known that regardless of the reconstructive technique, loss of nipple projection can be reasonably expected. We developed and evaluated a quick, simple, and innovative technique using injectable Integra Flowable Wound Matrix to increase nipple projection after reconstruction. Twenty breast cancer patients who underwent nipple reconstruction resulting in unsatisfactory projection were enrolled in our retrospective study. Nipple projection was measured at the time of surgery and after 6 and 12 months. A visual analogue scale was used to assess patients' satisfaction. Our technique yielded reliable results in terms of the long-lasting maintenance of nipple projection. This method is high-priced, but cost-effective, since one kit may suffice for three patients. Furthermore, our patients were very appreciative of this technique as a single-step, minimally invasive, painless procedure with no reported necessity of re-intervention.

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

Computational reconstruction techniques in integral imaging by use of a lenslet array

  • Shin, Dong-Hak;Kim, Eun-Soo;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1588-1591
    • /
    • 2005
  • In this paper, we propose novel computational reconstruction technique of three-dimensional objects in integral imaging by use of a lenslet array. We applied our technique to two different integral imaging systems according the distance between lenslet array and elemental image plane. Experimental results are presented and discussed as well.

  • PDF

Occluded Object Motion Tracking Method based on Combination of 3D Reconstruction and Optical Flow Estimation (3차원 재구성과 추정된 옵티컬 플로우 기반 가려진 객체 움직임 추적방법)

  • Park, Jun-Heong;Park, Seung-Min;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.5
    • /
    • pp.537-542
    • /
    • 2011
  • A mirror neuron is a neuron fires both when an animal acts and when the animal observes the same action performed by another. We propose a method of 3D reconstruction for occluded object motion tracking like Mirror Neuron System to fire in hidden condition. For modeling system that intention recognition through fire effect like Mirror Neuron System, we calculate depth information using stereo image from a stereo camera and reconstruct three dimension data. Movement direction of object is estimated by optical flow with three-dimensional image data created by three dimension reconstruction. For three dimension reconstruction that enables tracing occluded part, first, picture data was get by stereo camera. Result of optical flow is made be robust to noise by the kalman filter estimation algorithm. Image data is saved as history from reconstructed three dimension image through motion tracking of object. When whole or some part of object is disappeared form stereo camera by other objects, it is restored to bring image date form history of saved past image and track motion of object.

Late reconstruction of oncological maxillary defect with microvascular free flap (상악결손부의 2차적 재건에 있어 유리 혈관화 피판의 적용)

  • Kwon, Tae-Geon;Kim, Chin-Soo
    • The Journal of the Korean dental association
    • /
    • v.49 no.9
    • /
    • pp.527-534
    • /
    • 2011
  • Microvascular reconstruction of maxillary composite defect after oncologic resection has improved both esthetic and functional aspect of quality of life of the cancer patients. However, a lot of patients had prior surgery with radiation and/or chemotherapy as a part of comprehensive cancer treatment. Sometimes it is nearly impossible to find out adequate recipient vessel for maxillary reconstruction with microvascular anastomosis. Therefore long pedicle of the flap is needed to use distant neck vessels located far from the reconstruction site such as ipsilateral transverse cervical artery or a branch of contralateral external carotid artery. For this reason, although we know the treatment of the choice is osteocutaneous flap, it is difficult to use this flap when we need long pedicle with complex three dimensional osseous defect. Vascular option for these vessel-depleted neck patients can be managed by a soft tissue reconstruction with long vascular pedicle and additional free non-vascularized flap that is rigidly fixed to remaining skeletal structures. For this reason, maxillofacial reconstruction by vascularized soft tissue flap with or without the secondary restoration of maxillary bone with non-vascularized iliac bone can be regarded as one of options for reconstruction of profound maxillofacial composite defect resulted from previous oncological resection with chemo-radiotherapy.

Quantitative analysis of three dimensional volumetric images in Chest CT (흉부 CT 검사에서 3차원 체적 영상의 정량적 분석)

  • Jang, Hyun-Cheol;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.255-260
    • /
    • 2011
  • We wanted to evaluate the usefulness of three-dimensional reconstructive images using computed tomography for rib fracture patients. The reconstruction used in clinical multi planar reformation(MPR), volume rendering technique(VRT), and image data using quantitative methods and qualitative methods were compared. Much more, the artifact shadow was minimized to reconstruct with 3D volumetric image by using an law data in the analysis of the reconstructive image and chest CT scan of the evaluation result fractures of the thoracic patient. And we could know that the fractures of the thoracic determination and three dimension volume image reconstruction time were reduced.

Detection of Foreign Body in Esophageal Foreign Body Model Using Three Dimensional Reconstruction Technique (식도 이물 모델에서 이물 탐색을 위한 삼차원 재구성법의 활용)

  • Woo, Kuk Sung;Yoo, Young Sam;Kim, Dong Won
    • Korean Journal of Bronchoesophagology
    • /
    • v.18 no.1
    • /
    • pp.13-18
    • /
    • 2012
  • Objective This study was conducted to gather basic information of 3D CT in detecting and gaining information of esophageal foreign body (FB) models. Materials and Methods The chest model was made using PVC bottle, rubber balloon and plaster. Fish bone, Persimmon stone were used to mimic foreign bodies of esophageal model. The foreign body models were inserted into the balloon removing air from it and the balloon was sealed. The esophageal FB model was inserted into the chest model. The remaining space in the chest model was filled with fish paste and water to simulate soft tissue around esophagus. CT of chest model was reconstructed three-dimensionally by Rapidia software to make images of foreign body models. The axial CT, MPR image and VOI image were compared with real foreign body materials as to shape, size, location and orientation. Results Esophageal FB models were easily made. CT data gave good 3D images and showed realistic foreign body materials. Conclusion The results indicate the usefulness of 3D CT technique to help in diagnosis of esophageal foreign body models.

  • PDF

Analysis of Isometric Position of the Anterior Cruciate Ligament During the Knee Flexion-Extension (무릎 굴신 운동과 전십자 인대의 등장위치 해석)

  • Park J.H.;Son K.;Moon B.Y.;Suh J.T.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1933-1936
    • /
    • 2005
  • The isometric area of the anterior cruciate ligament was calculated during knee flexion-extension. Flexion-extension motion data of the joint were obtained using Fastrak and a three-dimensional motion measurement system. A total of five subjects were seated on a flat table and the tibia sensor position was measured with the femur fixed on the table. A three-dimensional knee model was constructed using a graphic tool to simulate the knee motion. Twenty seven positions of the tibia region and forty two positions of the femur region were selected and the distances between the determined tibial and femoral points were calculated. Highly isometric areas were found and displayed as three dimensional aspects.

  • PDF

Optical Implementation of Three-Dimensional Image using Modified Triangular Interferometer (변형 삼각간섭계를 이용한 3차원 영상의 광학적 구현)

  • 김수길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.15-20
    • /
    • 2004
  • We presented the optical reconstruction system of complex hologram and theoretically demonstrated that the proposed system could display complex hologram. And we made the complex hologram of a three-dimensional image using the modified triangular interferometer, and presented and analyzed the three-dimensional images numerically and optically reconstructed from it.

Three-dimensional Information and Refractive Index Measurement Using a Dual-wavelength Digital Holographic

  • Shin, Sang-Hoon;Yu, Young-Hun
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.173-177
    • /
    • 2009
  • Digital holographic microscopy allows optical path difference measurement. Optical path difference depends on the both refractive index and morphology of sample. We developed a dual-wavelength in-line digital holographic microscope that can measure simultaneously the refractive index and morphology of a sample, providing highly precise three-dimensional information. Here we propose theoretical and experimental methods for dual-wavelength in-line digital holographic microscopy. The measured data were reasonable, although there was data error. By improving the experimental method, we could measure the refractive index more precisely and obtain more accurate three-dimensional information on samples.