• Title/Summary/Keyword: Three-dimensional Measurements

Search Result 700, Processing Time 0.031 seconds

Power Savings of a Refrigerator with 3D-PTV Measurements (3D-PTV에 의한 냉장고 소비전력 저감)

  • Hwang Tae-Gyu;Doh Deog-Hee;Park Seong-Ryong;Bang Yoon-Seok;Yang Min-Cheol;Jang Gyu-Seob;Kim Suk-Roh;Lee Yeon-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1145-1153
    • /
    • 2005
  • 3D-PTV measurement has been carried out for the inner flows of a refrigerator. To visualize the air flows three-dimensionally, a helium bubble generator has been used for the 3D-PTV measurements. Three-dimensional flow field of the refrigerator's compartments have been reconstructed by the results obtained by the 3D-PTV Measurements on the electric power-consumption was also carried out in order to evaluate the improvements of the flow characteristics. It was verified that $3\%$ of power consumption was saved by improving the flow passages and characteristics.

Usefulness of 3-Dimensional Body Surface Scanning in the Evaluation of Patients with Pectus Carinatum

  • Song, Seung Hwan;Kim, Chong Hoon;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.301-305
    • /
    • 2020
  • Background: Radiographic modalities have been commonly used to evaluate pectus carinatum (PC), and compressive orthotic bracing is the most widely accepted treatment method. The aim of this study was to determine the efficacy of 3-dimensional (3D) body surface scanning as an alternative modality for the evaluation of PC. Methods: The medical records of 63 patients with PC who were treated with compressive orthotic bracing therapy between July 2017 and February 2019 were retrospectively analyzed. Using both 2-view chest radiography (posteroanterior and lateral view) and 3D body scanning, the height of maximal protrusion of the chest wall was measured both before and after 2 weeks of bracing therapy. The difference between the pre- and post-treatment measurements was calculated for both modalities, and these differences were compared and analyzed. Results: Based on the comparison between the pre- and post-treatment radiographs, bracing therapy produced favorable outcomes in all patients (p<0.001). The measurements obtained via 3D scanning were strongly correlated with those obtained via chest radiography (r=0.60). Conclusion: Based on the findings of this study, 3D body surface scanning appears to be an effective, radiation-free, and simple method for the post-treatment follow-up evaluation of PC, and thus can be considered an alternative to radiography.

Dosimetric Characteristic of Digital CCD Video Camera for Radiation Therapy

  • Young Woo. Vahc;Kim, Tae Hong.;Won Kyun. Chung;Ohyun Kwon;Park, Kyung Ran.;Lee, Yong Ha.
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.147-155
    • /
    • 2000
  • Patient dose verification is one of the most important parts in quality assurance of the treatment delivery for radiation therapy. The dose distributions may be meaningfully improved by modulating two dimensional intensity profile of the individual high energy radiation beams In this study, a new method is presented for the pre-treatment dosimetric verification of these two dimensional distributions of beam intensity by means of a charge coupled device video camera-based fluoroscopic device (henceforth called as CCD-VCFD) as a radiation detecter with a custom-made software for dose calculation from fluorescence signals. This system of dosimeter (CCD-VCFD) could reproduce three dimensional (3D) relative dose distribution from the digitized fluoroscopic signals for small (1.0$\times$1.0 cm$^2$ square, ø 1.0 cm circular ) and large (30$\times$30cm$^2$) field sizes used in intensity modulated radiation therapy (IMRT). For the small beam sizes of photon and electron, the calculations are performed In absolute beam fluence profiles which are usually used for calculation of the patient dose distribution. The good linearity with respect to the absorbed dose, independence of dose rate, and three dimensional profiles of small beams using the CCD-VCFD were demonstrated by relative measurements in high energy Photon (15 MV) and electron (9 MeV) beams. These measurements of beam profiles with CCD-VCFD show good agreement with those with other dosimeters such as utramicro-cylindrical (UC) ionization chamber and radiographic film. The study of the radiation dosimetric technique using CCD-VCFD may provide a fast and accurate pre-treatment verification tool for the small beam used in stereotactic radiosurgery (SRS) and can be used for verification of dose distribution from dynamic multi-leaf collimation system (DMLC).

  • PDF

Pitch Measurement of 150 nm 1D-grating Standards Using an Nano-metrological Atomic Force Microscope

  • Jonghan Jin;Ichiko Misumi;Satoshi Gonda;Tomizo Kurosawa
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.3
    • /
    • pp.19-25
    • /
    • 2004
  • Pitch measurements of 150 nm one-dimensional grating standards were carried out using a contact mode atomic force microscopy with a high resolution three-axis laser interferometer. This measurement technique was named as the 'nano-metrological AFM'. In the nano-metrological AFM, three laser interferometers were aligned precisely to the end of an AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$ stabilized He-Ne laser at a wavelength of 633 nm. Therefore, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM could be used to directly measure the length standard. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM). The primary source of uncertainty in the pitch-measurements was derived from the repeatability of the pitch-measurements, and its value was about 0.186 nm. The average pitch value was 146.65 nm and the combined standard uncertainty was less than 0.262 nm. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

A Study on the Compensation of Thermal Errors for Phase Measuring Profilometry (PMP 형상 측정법의 열 변위 보정에 관한 연구)

  • Kim, Gi-Seung;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.598-603
    • /
    • 2019
  • Three-dimensional shape measurement technology is used in various industries. Among them, optical three-dimensional shape measurement techniques based on the optical trigonometry are mainly used in the field of semiconductor product inspection, where large quantities of three-dimensional shape measurements are made daily in factories and fine measurements are also required. The light source and the drive circuit, which are components of three-dimensional measurement equipment based on this optical trigonometry, produce heat generated by prolonged operation, and may be exposed to conditions where the ambient temperature is not constant, resulting in temperature-induced measurement errors. In this study, the compensation method of the Thermal Errors for Phase Measuring Profilometry is proposed. Three-Dimensional Shape Measurement Equipment based on Phase Measuring Profilometry is implemented to measure the height of an object and ambient temperature for 10 Hours, and a regression line was obtained line by making simple linear regression using measured temperature and height values. This regression line was used to correct the error of the height measurement according to the temperature, and thermal error was from 139.88 um(Micrometer) to 13.12 um.

Comparison of conventional lateral cephalograms with corresponding CBCT radiographs

  • Park, Chang-Seo;Park, Jae-Kyu;Kim, Huijun;Han, Sang-Sun;Jeong, Ho-Gul;Park, Hyok
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.201-205
    • /
    • 2012
  • Purpose: This study was performed to assess the compatibility of cone beam computed tomography (CBCT) synthesized cephalograms with conventional cephalograms, and to find a method for obtaining normative values for three-dimensional (3D) assessments. Materials and Methods: The sample group consisted of 10 adults with normal occlusion and well-balanced faces. They were imaged using conventional and CBCT cephalograms. The CBCT cephalograms were synthesized from the CBCT data using OnDemand 3D software. Twenty-one angular and 12 linear measurements from each imaging modality were compared and analyzed using paired-t test. Results: The linear measurements between the two imaging modalities were not statistically different (p>0.05) except for the U1 to facial plane distance. The angular measurements between the two imaging modalities were not statistically different (p>0.05) with the exception of the gonial angle, ANB difference, and facial convexity. Conclusion: Two-dimensional cephalometric norms could be readily used for 3D quantitative assessment, if corrected for lateral cephalogram distortion.

Evaluation of Dynamic Characteristic of a Globe Valve with Various Plug Types (플러그 형상에 따른 글로브 밸브의 동특성 평가)

  • Ko S. H.;Park S.;Yang S. M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.29-32
    • /
    • 2004
  • A three dimensional numerical analysis and experimental measurements were made for incompressible flows in a globe valve with three different types of plug. Characteristics of pressure drop across the valve were investigated for each type of plug at various opening positions. Numerical simulation results show a good agreement with experimental data.

  • PDF

Prediction and Measurement of the Path Loss in a Building including the Staircase (계단이 포함된 건물 내부의 경로손실 예측과 측정)

  • 최태관;김성진;김채영
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.219-222
    • /
    • 1999
  • A SBR/Image ray-tracing technique using triangular ray tubes to predict the effects of walls. rooms. floors, and staircase is considered. Suggested technique is very efficient to estimate the path loss in three-dimensional buildings including the staircase. The model to predict the path loss through walls and floors in a multifloored building is presented. Measurements are made for three corridors having the staircase at 850 MHz, Measured data shows a close agreement with a simulated data.

  • PDF

Experimental validation of smartphones for measuring human-induced loads

  • Chen, Jun;Tan, Huan;Pan, Ziye
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.625-642
    • /
    • 2016
  • The rapid technology developments in smartphones have created a significant opportunity for their use in structural live load measurements. This paper presents extensive experiments conducted in two stages to investigate this opportunity. Shaking table tests were carried out in the first stage using selected popular smartphones to measure the sinusoidal waves of various frequencies, the sinusoidal sweeping, and earthquake waves. Comparison between smartphone measurements and real inputs showed that the smartphones used in this study gave reliable measurements for harmonic waves in both time and frequency domains. For complex waves, smartphone measurements should be used with caution. In the second stage, three-dimensional motion capture technology was employed to explore the capacity of smartphones for measuring the movement of individuals in walking, bouncing and jumping activities. In these tests, reflective markers were attached to the test subject. The markers' trajectories were recorded by the motion capture system and were taken as references. The smartphone measurements agreed well with the references when the phone was properly fixed. Encouraged by these experimental validation results, smartphones were attached to moving participants of this study. The phones measured the acceleration near the center-of-mass of his or her body. The human-induced loads were then reconstructed by the acceleration measurements in conjunction with a biomechanical model. Satisfactory agreement between the reconstructed forces and that measured by a force plate was observed in several instances, clearly demonstrating the capability of smartphones to accurately assist in obtaining human-induced load measurements.

A Comprehensive Analysis of 3D Body Scanning vs. Manual Measurements in a Large-Scale Anthropometric Survey -Insights from the 8th Size Korea Project- (대규모 인체치수조사 사업에서 3차원 측정치와 직접측정치의 차이 분석 -제8차 사이즈코리아 사업을 중심으로-)

  • Sunmi Park
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.2
    • /
    • pp.233-253
    • /
    • 2024
  • This study analyzed differences between three-dimensional (3D) body scanning and manual measurements, aiming to assess whether 3D scanning can replace traditional anthropometric tools, such as tape measures and calipers. Data from 4,478 participants in the 8th Size Korea Project were analyzed, covering 43 measurement items. Since Given that the 3D and manual measurements were performed on the same subjects in the 8th Size Korea Project, it was possible to determine the correlation more accurately between the two measurement methods more accurately. Using Applying ISO 20685-1(2018) standards, 15 out of the 43 items fell within allowable error limits. When classified into six types, "small circumferences" and "segment lengths" showed averages of 3.35 mm and 3.10 mm, respectively, within acceptable range. "Body heights" and "body depths" slightly exceeded the limit, with averages of 5.28 mm and 6.58 mm. "Body widths" and "large circumferences" surpassed the limit, with means of 16.77 mm and 16.18 mm. The study offers an objective basis to for validate validating 3D measurements' measurements' reliability and accuracy, addressing various industries' needs for information on the human body's dimensions information.