• 제목/요약/키워드: Three-dimensional CT image

검색결과 195건 처리시간 0.023초

Automated 2D/3D Image Matching Technique with Dual X-ray Images for Estimation of 3D In Vivo Knee Kinematics

  • Kim, Yoon-Hyuk;Phong, Le Dinh;Kim, Kyung-Soo;Kim, Tae-Seong
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권6호
    • /
    • pp.431-435
    • /
    • 2008
  • Quantitative information of a three dimensional(3D) kinematics of joint is very useful in knee joint surgery, understanding how knee kinematics related to joint injury, impairment, surgical treatment, and rehabilitation. In this paper, an automated 2D/3D image matching technique was developed to estimate the 3D in vivo knee kinematics using dual X-ray images. First, a 3D geometric model of the knee was reconstructed from CT scan data. The 3D in vivo position and orientation of femoral and tibial components of the knee joint could be estimated by minimizing the pixel by pixel difference between the projection images from the developed 3D model and the given X-ray images. The accuracy of the developed technique was validated by an experiment with a cubic phantom. The present 2D/3D image matching technique for the estimation of in vivo joint kinematics could be useful for pre-operative planning as well as post-operative evaluation of knee surgery.

Quantitative Feasibility Evaluation of 11C-Methionine Positron Emission Tomography Images in Gamma Knife Radiosurgery : Phantom-Based Study and Clinical Application

  • Lim, Sa-Hoe;Jung, Tae-Young;Jung, Shin;Kim, In-Young;Moon, Kyung-Sub;Kwon, Seong-Young;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.476-486
    • /
    • 2019
  • Objective : The functional information of $^{11}C$-methionine positron emission tomography (MET-PET) images can be applied for Gamma knife radiosurgery (GKR) and its image quality may affect defining the tumor. This study conducted the phantom-based evaluation for geometric accuracy and functional characteristic of diagnostic MET-PET image co-registered with stereotactic image in Leksell $GammaPlan^{(R)}$ (LGP) and also investigated clinical application of these images in metastatic brain tumors. Methods : Two types of cylindrical acrylic phantoms fabricated in-house were used for this study : the phantom with an array-shaped axial rod insert and the phantom with different sized tube indicators. The phantoms were mounted on the stereotactic frame and scanned using computed tomography (CT), magnetic resonance imaging (MRI), and PET system. Three-dimensional coordinate values on co-registered MET-PET images were compared with those on stereotactic CT image in LGP. MET uptake values of different sized indicators inside phantom were evaluated. We also evaluated the CT and MRI co-registered stereotactic MET-PET images with MR-enhancing volume and PET-metabolic tumor volume (MTV) in 14 metastatic brain tumors. Results : Imaging distortion of MET-PET was maintained stable at less than approximately 3% on mean value. There was no statistical difference in the geometric accuracy according to co-registered reference stereotactic images. In functional characteristic study for MET-PET image, the indicator on the lateral side of the phantom exhibited higher uptake than that on the medial side. This effect decreased as the size of the object increased. In 14 metastatic tumors, the median matching percentage between MR-enhancing volume and PET-MTV was 36.8% on PET/MR fusion images and 39.9% on PET/CT fusion images. Conclusion : The geometric accuracy of the diagnostic MET-PET co-registered with stereotactic MR in LGP is acceptable on phantom-based study. However, the MET-PET images could the limitations in providing exact stereotactic information in clinical study.

The location of midfacial landmarks according to the method of establishing the midsagittal reference plane in three-dimensional computed tomography analysis of facial asymmetry

  • Kim, Min Sun;Lee, Eun Joo;Song, In Ja;Lee, Jae-Seo;Kang, Byung-Cheol;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.227-232
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the influence of methods of establishing the midsagittal reference plane (MRP) on the locations of midfacial landmarks in the three-dimensional computed tomography (CT) analysis of facial asymmetry. Materials and Methods: A total of 24 patients (12 male and 12 female; mean age, 22.5 years; age range, 18.2-29.7 years) with facial asymmetry were included in this study. The MRP was established using two different methods on each patient's CT image. The x-coordinates of four midfacial landmarks (the menton, nasion, upper incisor, and lower incisor) were obtained by measuring the distance and direction of the landmarks from the MRP, and the two methods were compared statistically. The direction of deviation and the severity of asymmetry found using each method were also compared. Results: The x-coordinates of the four anatomic landmarks all showed a statistically significant difference between the two methods of establishing the MRP. For the nasion and lower incisor, six patients (25.0%) showed a change in the direction of deviation. The severity of asymmetry also changed in 16 patients (66.7%). Conclusion: The results of this study suggest that the locations of midfacial landmarks change significantly according to the method used to establish the MRP.

Stafne Bone Cavity of the Mandible

  • Lee, Jae Il;Kang, Seok Joo;Jeon, Seong Pin;Sun, Hook
    • 대한두개안면성형외과학회지
    • /
    • 제17권3호
    • /
    • pp.162-164
    • /
    • 2016
  • Stafne bone cavity is a rare mandibular defect that was first reported by Edward C. Stafne in 1942. It commonly presents with a well-demarcated, asymptomatic, unilateral radiolucency that indicates lingual invagination of the cortical bone. A 52-year-old female patient who with nasal bone fracture, visited the hospital. During facial bone computed tomography (CT) for facial area evaluation, a well-shaped cystic lesion was accidentally detected on the right side of the mandible. Compared to the left side, no swelling or deformity was observed in the right side of the oral lesion, and no signs of deformity caused by mucosal inflammation. 3D CT scans, and mandible series x-rays were performed, which showed a well-ossified radiolucent oval lesion. Axial CT image revealed a cortical defect containing soft tissue lesion, which has similar density as the submandibular gland on the lingual surface of the mandible. The fact that Stafne cavity is completely surrounded by the bone is the evidence to support the hypothesis that embryonic salivary gland is entrapped by the bone. In most cases, Stafne bone cavity does not require surgical treatment. We believe that the mechanical pressure from the salivary gland could have caused the defect.

하악 전돌증 환자의 악교정 수술에서 기도 공간의 부피변화에 관한 3차원적 분석 (THE THREE DIMENSIONAL ANALYSIS OF VOLUMETRIC AIRWAY CHANGE IN ORTHOGNATHIC SURGERY OF MANDIBULAR PROGNATHISM)

  • 이지호;팽준영;명훈;황순정;서병무;최진영;이종호;정필훈;김명진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권6호
    • /
    • pp.552-558
    • /
    • 2005
  • Orthognathic surgery changes patient's mandibular position and environment of related anatomic structures. Many clinicians were interested in these changes and studied about this problem. However, most of them were based on two dimensional cephalogram. According to the development of image and computer system, it would be possible that the airway change is analyzed with three dimensional CT. So we tried to measure the volumetric change of airway and analyzed the relationship between the airway structure and volumetric change. Nineteen patients who experienced orthognathic surgery due to mandibular prognathism were analyzed with 3D CT data (preoperative and postoperative 6 months) and 2D lateral cephalometry. Volumetric change was measured and 3 dimensional change of related structure was assessed with simulation program ($V-works^{(R)}$, 4.0 Cybermed, Korea). Ten patients showed the decrease of airway volume change and nine showed the increase of airway volume change. Volumetric change was determined by dimensional change of mandible and hyoid bone. The dimensional positions of mandible and hyoid bone were the key factor for determining the airway change after surgery. Airway change is also predictable with the dimensional change of mandible and hyoid bone.

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF

전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석 (Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion)

  • 김수산;하성환;최은경;이병용
    • Radiation Oncology Journal
    • /
    • 제22권1호
    • /
    • pp.55-63
    • /
    • 2004
  • 목적 : 방사선치료계획용 전산화단층활영(computerized tomography, 이하 CT) 시 주사시간이 종양부피의 재현성에 미치는 영향을 살펴보고자 하였다. 대상 및 방법 : 인공호흡기의 환기작용에 의해 세로방향의 왕복 운동을 하는 N자형 모형을 제작하였고, 호흡주기를 T로 하였을 때 주사시간을 상대적으로 각각 0.33, 0.50, 0.67, 0.75, 1.00, 1.33, 그리고 1.53 T로 설정하고 CT촬영을 시행하였다. 또한 2002년 3월 19일부터 2002년 5월 21일까지 서울아산병원 방사선종양학과에서 정위방사선수술(stereotactic radiosurgery)을 시행받은 비소세포성 폐암 환자 3명을 대상으로, 주사시간이 빠른 CT (LightSpeed, GE Medical Systems, 주사시간 0.8초)와 느린 CT (IQ Premier, Picker, 주사시간 2.0초)를 각각 $1\~4$회 시행하였다. 각각의 slice에서, N자형 모형의 왕복 운동이 CT 영상에 반영된 좌우방향 선분의 길이를 측정하여 치료계획용 CT 촬영이 모형의 움직임을 반영하는 정도를 측정하였다. 환자를 대상으로 한 연구에서는 정위적 체부 고정틀을 이용하여, 빠른 CT 및 느린 CT의 종양을 하나의 CT 영상조합에서 재구성하여 종양의 체적과 장경을 측정하여 비교하였다. 결과 : 모형실험에서 주사시간에 비례하여, 세로방향 운동을 CT 촬영에서 반영하는 정도는 증가하였으며 1.00 T 이상에서는 일정한 양상을 보였다 주사시간 1.00 T 이상에서 얻어진 결과를 기준으로, 1.00 T 미만의 주사시간을 가지는 CT촬영에서 모형운동을 반영하지 못하는 비율이 각각 $0.33\;T:\;30\%,\;0.50\;T:\;27\%,\;0.67\;T:\;20\%,\;0.75\;T:\;7.0\%$로 측정되었다. 또한 투시검사로 측정한 종양의 세로 방향 움직임이 각각 3 mm, 5 mm, 10 mm이었던 각각의 환자에서 느린 CT에서 얻어진 종양의 세로방향 장경이 빠른 CT에 비해 $5.3\%\;17\%,\;23\%$ 증가하였다. 결론 : 주사시간을 환자의 호흡주기 이상으로 하는 경우 setup margin만을 고려하여 계획용표적체적(planning target volume, PTV)을 정의할 수 있으므로 정상 폐조직에 조사되는 방사선량을 줄여 치료효율을 향상시킬 수 있을 것으로 생각된다.

방광암 환자의 영상유도 방사선치료에 관한 고찰 (The Investigation Image-guided Radiation Therapy of Bladder Cancer Patients)

  • 배성수;배선명;김진산;강태영;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제24권1호
    • /
    • pp.39-43
    • /
    • 2012
  • 목 적: 현재 본원에서 방광암 환자의 영상유도 방사선치료는 재현성을 높이기 위하여 환자의 상태에 따라 알맞은 양의 생리식염수를 주입하고 영상유도 시스템(On-Board Imager system, OBI, VARIAN, USA)의 Cone.Beam CT (CBCT)로 3차원 정합(3D-3D matching)을 하여 치료를 한다. 본 연구에서는 방광암 환자의 치료 시 획득한 CBCT 영상의 분석을 통해 뼈를 기준으로 한 정합과 방광을 기준으로 한 정합의 차이를 알아보고, 생리 식염수를 주입한 방광의 체적 변화를 알아보고 방광암 환자의 치료 시 더욱 적절한 영상정합방법을 평가하고 고찰하고자 한다. 대상 및 방법: 본원에서 2009년 1월에서 2010년 4월까지 방사선치료를 위해 내원한 방광암 환자 7명을 대상으로 Folly catheter를 이용하여 방광 내 잔류 소변을 제거한 뒤 환자 개개인에 맞게 정해진 양 만큼의 생리식염수를 주입하고 CT-Sim 후 치료계획을 설계하였다. 그 뒤 OBI system을 이용하여 치료 전 자세 확인을 위해 CBCT를 찍었고, 담당 주치의가 모든 대상 환자의 영상 정합을 진행하였다. 총 45개 CBCT 영상을 이용하여 뼈를 기준으로 한 영상정합과 방광을 기준으로 한 영상정합의 차이를 분석하였다. 또, 방광의 체적 변화를 Eclipse (version 8.0, VARIAN, USA)를 통해 얻어냈다. 결 과: 뼈를 기준으로 한 영상정합을 한 후 다시 방광을 기준으로 한 정합의 차이는 X축으로 평균 $3{\pm}2mm$, Y축으로 $1.8{\pm}1.3mm$, Z축으로 $2.3{\pm}1.7mm$이고 전체 이동거리는 $4.8{\pm}2.0mm$로 나타났다. 또 방광의 체적은 기준 대비 $4.03{\pm}3.97%$의 차이를 나타냈다. 결 론: 방광의 특성상 해부학적 위치 및 내부의 움직임으로 인해 뼈를 이용한 영상정합 후에도 방광의 위치 차이가 발생하였다. 또, 생리식염수를 채운 방광의 체적은 4.03%의 차이를 나타냈으나 영상 정합 시 모두 계획한 볼륨 안에 포함되는 것을 확인 할 수 있었다. 따라서 생리식염수를 주입한 뒤 방광을 기준으로 영상 정합을 실시함으로써 더욱 정확한 치료를 실시 할 수 있을 것으로 사료된다.

  • PDF

조영법을 이용한 뇌수막종에서 3차원 CT영상의 유용성 (Usefulness of Three-Dimensional CT Image in Meningioma Using Contrast Method)

  • 이준행;백성은;이상복;김용완
    • 한국방사선학회논문지
    • /
    • 제2권1호
    • /
    • pp.17-21
    • /
    • 2008
  • 본 연구에서는 뇌수막종이 늦게 조영증강 된다는 점을 착안하여 뇌수막종을 최대 조영 증강시킨 검사를 시작하였다, 검사 후에 두개내의 수막종과 혈관과의 관계를 알아보고 전산화 단층 촬영 조영술의 3차원 CT 영상 기법(이하, 3차원 CT 영상 기법)과 고식적 혈관 촬영 조영술의 영상을 비교하였다. 연구대상은 3차원 CT 영상 기법과 고식적 혈관 촬영 조영술을 병행 시행하였던 6명의 환자를 대상으로 하였으며. 그 중 추체접형골동사대부 5예, 방시상동에 생긴 1예였다. 검사방법으로는 조영제를 초당 3/120 ml를 주입하여, GE Medical System Program(smart prep)을 이용하여 CT Number 값이 100에 도달한 후, 검사를 시작하였다. 스캔파라미터는 조영제가 모두 주입된 직후에 1.25 mm / 3.75 mm, HQ-Mode로 scan한 후 1 mm interval로 재구성하였다. 검사한 영상을 3D-Med Software Program(Rapidia)을 이용하여 3차원 CT 영상 기법으로 영상을 재구성한 다음 고식적 혈관 촬영 조영술과 비교하였다. 결과를 살펴보면 뇌수막종의 최대조영 시간은 조영제을 주입한 후 약120-180초에 혈관과 종양과의 관계를 가장 잘 구별할 수 있었다. 3차원 CT 영상 기법으로 재구성한 6예는 모두 종양과 혈관과의 관계를 잘 구별할 수 있었다. 또한 종양과 동반된 동맥류도 1예에서 잘 보여주었다. 이를 종합하여 보면 두 개 내 뇌수막종의 환자에서 조영제를 주입하여 3차원 CT 영상을 시행하였던 영상은 종양과 혈관과의 관계를 입체적으로 구분할 수 있어 수술에 많은 도움이 되었다.

  • PDF

입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획 (3-D Conformal Radiotherapy for CNS Using CT Simulation)

  • 추성실;조광환;이창걸
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.90-98
    • /
    • 2003
  • 목적 : 척수에 전이가 가능한 뇌종양 치료를 위한 두개척수 방사선치료를 전산화단층촬영장치(volumetric spiral CT)와 입체조준장치(CT simulator) 및 3차원 조형치료계획장치(3D conformal planning system)를 이용한 두개척수 방사선치료계획 방법을 개발하고 기하학적 검증을 통하여 유용성과 정확성을 평가한다. 방법 : 연세암센터 방사선종양학과에서 두개척수 방사선치료를 받은 환자 11명을 대상으로 전산화 단층촬영을 이용한 입체 모의치료계획과 3차원 방사선조형치료를 시행하였다. 중증의 뇌종양 환자의 두경부는 두부고정틀(thermoplastic mask, $Aquaplast^{R}$)로 고정시키고, 전신은 $Vac-Loc$ $Aquaplast^{R}$ (전성물산, 한국)으로 고정한 후 전산화단층촬영장치(Spiral CT)를 이용하여 전신체적영상(volumetric image)을 얻었다. 환자자세의 재현성 확인 및 검증을 위해 두부에 세 개의 점과 전신에 기준선 및 기준점 등을 표시하였다. 이후 입체조준장치(CT-simulator)의 가상현실영상(virtual fluoroscopy)에서 인체의 크기와 방향에 제약이 없고 치료 침대와 고정기구에 대한 시각장애를 제거함으로써 자유롭게 모의치료를 할 수 있었으며, 조사면과 선속을 결정하고 디지털화재구성사진(digitally reconstructed radiography, DRR)과 디지털화합성사진(digitally composited radiography, DCR)을 통하여 분해능이 좋은 화질의 투시 및 모의치료영상을 획득하였다. 기하학적 검증은 치료중심점 이동시 얻은 모의치료영상과 첫 치료 시에 얻은 조사면 검증 사진(port verification film) 등을 전산화단층촬영영상으로부터 재구성한 DRR 영상과 시각적, 정량적으로 비교, 분석 였다. 결론 : 입체조준장치와 3차원 방사선치료계획 장치 등을 이용하여 두개척수 방사선 치료계획을 신속하고 정확하게 원활히 수행할 수 있었다. 가상현실영상에서 대부분의 설계작업이 이루어지므로 환자의 자세고정을 요하는 시간은 전신체적 영상을 얻는 10분 이내이므로 환자의 불편을 줄일 수 있을 뿐 아니라 모의치료과정 중의 체위 변동 변수를 제거할 수 있었다. 또한 전산화단층촬영영상을 얻음으로써 중요정상조직인 안구, 척수 등을 정확하게 설정할 수 있었고, 조사면 결정과 차폐의 정확성을 증진시킬 수 있었다. 환자자세오차는 디지털화재구성사진과 치료 시마다 얻은 포트필름에서 치료중심점과 척수 사이의 거리를 측정하여 3 mm 이내의 정확성을 얻을 수 있었다. CT조준장치를 이용한 중추신경계의 방사선 입체조형치료는 가상현실모의치료계획으로 두개척수의 방사선치료를 정확하고 용이하게 실현할 수 있었다.

  • PDF