• 제목/요약/키워드: Three-dimensional CT image

검색결과 195건 처리시간 0.036초

Three-dimensional soft tissue analysis for the evaluation of facial asymmetry in normal occlusion individuals

  • Hwang, Hyeon-Shik;Yuan, Donghui;Jeong, Kweon-Heui;Uhm, Gi-Soo;Cho, Jin-Hyoung;Yoon, Sook-Ja
    • 대한치과교정학회지
    • /
    • 제42권2호
    • /
    • pp.56-63
    • /
    • 2012
  • Objective: To identify the right and left difference of the facial soft tissue landmarks three-dimensionally from the subjects of normal occlusion individuals. Materials and Methods: Cone-beam computed tomography (CT) scans were obtained in 48 normal occlusion adults (24 men, 24 women), and reconstructed into 3-dimensional (3D) models by using a 3D image soft ware. 3D position of 27 soft tissue landmarks, 9 midline and 9 pairs of bilateral landmarks, were identified in 3D coordination system, and their right and left differences were calculated and analyzed. Results: The right and left difference values derived from the study ranged from 0.6 to 4.6 mm indicating a high variability according to the landmarks. In general, the values showed a tendency to increase according to the lower and lateral positioning of the landmarks in the face. Overall differences were determined not only by transverse differences but also by sagittal and vertical differences, indicating that 3D evaluation would be essential in the facial soft tissue analysis. Conclusions: Means and standard deviations of the right and left difference of facial soft tissue landmarks derived from this study can be used as the diagnostic standard values for the evaluation of facial asymmetry.

Evaluation of canal preparation with Ni-Ti rotary files by micro computed tomography

  • Lee, Jeong-Ho;Kim, Mi-Ja;Seok, Chang-In;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • 제29권4호
    • /
    • pp.378-385
    • /
    • 2004
  • The purpose of this study was to compare the effects of preparation with GT files and profiles .04 in shaping of root canals and reconstruct the three-dimensional root canal system using micro computed tomography 40 canals of the extracted human mandibular molars were used, and randomly distributed into two experimental groups. In group 1. canals were prepared by GT files. In group 2, Profiles .04. were used. Apical preparation size was #30. For each tooth pre and post operative cross-sectional images were obtained by the micro CT at 50 micron intervals. Pre and post operative cross-sectional images of 1, 2, 3, 5, and 8mm from the apex were compared. For each section. canal area and centering ratio were determined. For each tooth pre- and post-operative root canal volume from the furcation to the apex of the roots was calculated by three-dimensional image software. Following results were obtained: 1. At 8mm from the apex, area of dentin removed by GT rotary file was significantly larger than that by Profile .04. And at the other levels there was not a significant difference. 2. There was a trend for GT rotary file to remain more centered in the canals than Profile .04 at all levels. But at 3mm level. there was a statistically significant difference. 3. In root canal volume increments after instrumentation, there was no significant difference between two groups.

Stereo Vision과 디지털 화상상관법을 이용한 파괴시험편의 측면 함몰의 현장 측정 (In situ Measurement of Lateral Side-Necking of a Fracture Specimen Using a Stereo Vision and Digital Image Correlation)

  • 이정현;강기주
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.154-161
    • /
    • 2004
  • An experimental method for measuring side-necking deformation near a crack-tip is described. It is based on Stereoscopic Digital Speckle Photography and Digital Image Correlation, and it is simple and robust to mechanical vibration inherent to a hydraulic material test system. The validity and accuracy are evaluated through a calibration fur rigid body translation. A case study has been performed for a CT specimen made of a ductile steel and the three dimensional profiles of the side-necked region are presented as the load increases. Also, the details of the procedure and the surface treatment are discussed.

A Post Smoothing Algorithm for Vessel Segmentation

  • Li, Jiangtao;Lee, Hyo Jong
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2009년도 추계학술발표대회
    • /
    • pp.345-346
    • /
    • 2009
  • The segmentation of vessel including portal vein, hepatic vein and artery, from Computed Tomography (CT) images plays an important role in the therapeutic strategies for hepatic diseases. Representing segmented vessels in three dimensional spaces is extremely useful for doctors to plan liver surgery. In this paper, proposed method is focused on smoothing technique of segmented 3D liver vessels, which derived from 3D region growing approach. A pixel expand algorithm has been developed first to avoid vessel lose and disconnection cased by the next smoothing technique. And then a binary volume filtering technique has been implemented and applied to make the segmented binary vessel volume qualitatively smoother. This strategy uses an iterative relaxation process to extract isosurfaces from binary volumes while retaining anatomical structure and important features in the volume. Hard and irregular place in volume image has been eliminated as shown in the result part, which also demonstrated that proposed method is a suitable smoothing solution for post processing of fine vessel segmentation.

CT검사에서 조영제의 혈관외유출에 의한 목 및 흉부 손상의 3차원 재구성 영상 (Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings)

  • 권대철;장근조;유병규;이종석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.281-287
    • /
    • 2007
  • 전산화단층촬영에서 조영제를 자동주입기로 주입하는 과정에서 발생하는 혈관외유출은 조직의 괴사 및 손상의 원인이 되고 있다. 대량의 혈관외유출은 구획증후군으로 발전하여 근막절개술을 시행하는 경우가 발생한다. 혈관외유출이 발생한 환자를 대상으로 혈관외유출 범위 및 부위 정도를 평가하기 위해 CT 검사에서 경정맥에 조영제을 주입하는 과정에서 혈관외유출이 발생한 환자를 대상으로 하였다. 조영제에 의한 혈관외유출 범위 및 손상을 확인하기 조영제 주입부위의 목 및 가슴의 부위를 MDCT를 이용하여 스캔하였다. 경정맥 주사부위의 혈관외유출부위를 MPR, MIP와 볼륨 렌더링의 3차원영상을 3D 프로그램을 이용하여 묘출하였다. 3차원 재구성 영상은 높은 해상력과 정확도를 제공하여 혈관외유출 범위 및 부위를 확인 하여, 환자의 예방의 필요성 및 사후 조치 및 적절한 치료와 수술 계획에 유용하게 이용될 것으로 기대된다.

  • PDF

Analysis of Knit Fabric Structure with its Voxel Data

  • Shinohara, T.;Takayama, J.;Ohyama, S.;Kobayashi, A.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.53-56
    • /
    • 2003
  • For identifying how a sample knit fabric is woven a method to obtain positional information of each yarn of the sample from voxel data made out of its x-ray CT images is newly proposed in this paper. The positional information is obtained by tracing the each yarn. The each yarn is traced by estimating a direction of the yarn in a certain small region in which the yarn can be regarded as straight and moving the region slightly along the estimated direction alternately. The yarn direction is estimated by correlating the voxel data in the region with a three-dimensional yarn model. The effectiveness of this method is confirmed by applying the method to voxel data made out of CT images of a knit fabric experimentally.

  • PDF

가상내시경으로 본 후두개 낭종 (Application of Virtual Endoscopy in Epiglottic Cyst)

  • 유영삼;최정환;김상우;우국성;김동원
    • 대한기관식도과학회지
    • /
    • 제17권2호
    • /
    • pp.108-111
    • /
    • 2011
  • Epiglottic cysts cause stridor mimicking asthma and hinder intubation in surgery. A huge cyst can obstruct the airway, making laryngeal examinations impossible. Before surgery, complete visualization of the larynx is necessary for the successful excision of a cyst. If laryngeal examination fails, computed tomography (CT) scanning can provide detailed information. Virtual endoscopy based on CT data reconstruction can yield a detailed three-dimensional image of the larynx. Here, we report two cases of epiglottic cysts along with virtual endoscopic findings and surgical photographs.

  • PDF

골밀도를 고려한 척추성형술의 생체역학적 평가 (Biomechanical Evaluation of the Vertebroplasty Based on Bone Density)

  • 김동율;이태수;박정율;서중근;최귀원;채수원
    • 한국정밀공학회지
    • /
    • 제23권8호
    • /
    • pp.185-194
    • /
    • 2006
  • In this paper, three dimensional finite element analyses have been performed to investigate the biomechanics of vertebroplasty in patient accurate FE models have been constructed from CT images of a PMMA injected vertebra. In order to apply various material properties of the spine(T12), the functional relation between the well known apparent density and HU(Hounsfield unit) from CT image were employed and thus real material properties can be assigned to each element of FE model. The FE analysis showed similar results with the experiments. With this approach accurate analysis of the vertebroplasty and its clinical applications can be expected.

미세수술을 이용한 하지의 재건시 삼차원 컴퓨터 혈관조영술의 유용성 (Usefullness with 3D CT Angiography in Microsurgical Reconstruction)

  • 성용덕;김효헌
    • Archives of Plastic Surgery
    • /
    • 제33권2호
    • /
    • pp.175-180
    • /
    • 2006
  • Preoperative angiography is frequently used in the planning of microsurgical reconstruction for identification of vascular abnormality that influence the planning of operation. But, recently 3D CT angiography is considered as new technique that can provide detailed information about vascular anatomy as well as soft and bony tissue without the risks of invasive angiography. 3D CT angiograms were performed in 19 patients before microsurgical reconstruction for the lower extremity and hand between May of 2003 and Oct of 2004. Sixteen of the studies were of the donor site and all of 19 studies were of the recipient site. No complications were found from the 3D CT angiograms. In one case of the bone exposed open wound, the injury of anterior tibial artery was identified and the zone of injury was adequately demonstrated. With the improvement in quality of CT imaging, 3D CT angiograms may provide a favorable alternative to invasive angiography. It is capable of providing high-resolution, three dimensional vascular imaging without the need for arterial puncture and prolonged post-procedure observation. The relation among blood vessels, bones, and soft tissue is well demonstrated in 3D CT angiogram. Also The acquisition time and examination cost were considerably lower in comparison with invasive angiography. In conclusion, this study demonstrates that 3D CT angiography may provide accurate, safe, and cost-effective preoperative imaging. The 3D CT angiography with relatively low morbidity, low cost, ease of image acquisition can have an broader role in microsurgical reconstructive surgery.

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah;Ji, Gyu Yeul;Oh, Chang Hyun;Kim, Keung Nyun;Yoon, Do Heum;Shin, Hyunchul
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권4호
    • /
    • pp.441-447
    • /
    • 2017
  • Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.