• Title/Summary/Keyword: Three-Phase Current

Search Result 1,355, Processing Time 0.027 seconds

On the Safety and Performance Demonstration Tests of Prototype Gen-IV Sodium-Cooled Fast Reactor and Validation and Verification of Computational Codes

  • Kim, Jong-Bum;Jeong, Ji-Young;Lee, Tae-Ho;Kim, Sungkyun;Euh, Dong-Jin;Joo, Hyung-Kook
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1083-1095
    • /
    • 2016
  • The design of Prototype Gen-IV Sodium-Cooled Fast Reactor (PGSFR) has been developed and the validation and verification (V&V) activities to demonstrate the system performance and safety are in progress. In this paper, the current status of test activities is described briefly and significant results are discussed. The large-scale sodium thermal-hydraulic test program, Sodium Test Loop for Safety Simulation and Assessment-1 (STELLA-1), produced satisfactory results, which were used for the computer codes V&V, and the performance test results of the model pump in sodiumshowed good agreement with those in water. The second phase of the STELLA program with the integral effect tests facility, STELLA-2, is in the detailed design stage of the design process. The sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger performance test, the intermediate heat exchanger test facility, and the test facility for the reactor flow distribution are underway. Flow characteristics test in subchannels of a wire-wrapped rod bundle has been carried out for safety analysis in the core and the dynamic characteristic test of upper internal structure has been performed for the seismic analysis model for the PGSFR. The performance tests for control rod assemblies (CRAs) have been conducted for control rod drive mechanism driving parts and drop tests of the CRA under scram condition were performed. Finally, three types of inspection sensors under development for the safe operation of the PGSFR were explained with significant results.

A Study on Future System Construction Using WSCR Strengthness Index based on Python (Python 기반 WSCR 강건 지수를 이용한 미래계통 구축에 관한 연구)

  • Park, Seong-Jun;Hur, Jin;Kim, Hyun-Jin;Cho, Yoon-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.994-1001
    • /
    • 2018
  • In this paper, to studied about future power system construction using PSS / E-Python API. Python-based future system automatical construction methods and modeling of renewable sources. it confirmed the stability of the powert system for each renewable area by calculating the weighted short circuit ratio (WSCR) index. it calculated the short circuit ratio (SCR) and selected the transmission line linkage scenario to improve the stability of vulnerable areas. it confirmed the WSCR index improvement through the selected transmission line linkage of scenario, and analyzed the stability of the renewable power system applying the scenario. It describes Facts and Shunt devices adjustment for the load flow convergence. It describes the stable methed of the bus voltage through the transformer Ratio Tap adjustment. By performing PSS/E ASCC using the Python it was performed three-phase short circuit fault capacity analysis, it is confirmed whether excess of the fault current circuit breaker capacity. In order to contingency accident analysis, it have described the generation of one or two line list of each areas using the Python. The list is used to contingency analysis and describe the soluted of the transmission line overload through comparison before and after adding the scenario line.

Quality Monitoring of Specification of Crataegi Fructus in the Korean Pharmacopoeia and Studies HPLC Standard Chromatogram (산사(山楂)의 규격 기준 모니터링 및 HPLC 표준크로마토그램 연구)

  • Kim, Kyoung Hee;Kim, Sun Mi;Lee, Young Jong;Baek, Wan Sook
    • The Korea Journal of Herbology
    • /
    • v.32 no.1
    • /
    • pp.55-62
    • /
    • 2017
  • Objectives : Crataegi Fructus has been used as traditional medicines for more digestion action, amenorrhea due to blood stasis, and hyperlipemia. The aim of this study was to compare of Crataegi Fructus in South Korea collected during three years according to the standards in monographs of the Korean Pharmacopoeia Eleventh edition (KP 11). Methods : Crataegi Fructus was carried out identification test (Qualitative reaction, Thin layer chromatography), heavy metal test, and total ash registered at KP. Add to we tested loss on dry, contents of ethanol-soluble extracts, and HPLC profiling. Results : Identification test (TLC) was on comparing with ursolic acid standard solution in $R_f$ value, all samples showed red purple spot ($R_f$ value 0.9). Ursolic acid spot in $R_f$ value 0.35 showed by changing mobile phase condition. Heavy metals showed contents for Pb, Cd, As, and Hg range of 0.0 ~ 0.5 ppm, 0.0 ~ 0.2 ppm, 0.0 ~ 0.3 ppm, and 0.0 ~ 0.1 ppm. Loss on drying was ranged from 5.5 to 11.9 %, total ash was between the range 2.7 ~ 4.0 %. Contents of ethanol-soluble extracts was ranged from 17.8 to 44.9 %. The content of chlorogenic acid was ranged from 0.0 to 0.1 % based on the chlorogenic acid standard curve. Conclusion : We have verified the current specification standard of Crataegi Fructus and standard that is not set. We hope that it will help the standardization of Crataegi Fructus.

Determinants of Housewives' Caregiving Behavior to Elderly Parents-in-Law (II) : Development of a Causal Model (노인부양행위의 결정요인 II : 인과모형 개발)

  • Kim, Sang-Wook
    • Korean Journal of Social Welfare
    • /
    • v.38
    • /
    • pp.33-67
    • /
    • 1999
  • This study is the second phase of the author's larger attempt to investigate the factors affecting housewives' caregiving behavior to their elderly parents-in-law. Specifically, it revises and expands the previous model (1998) and develops a new one by rectifying the three major problems inherent in the previous study: (1) misspecification error; (2) non-equivalent comparison of results between the father-in-law model and mother-in-law model that stems from the inclusion of heterogeneous group of caregivers; (3) measurement problems for the two endogenous variables of eldercare attitude and behavior. To do this, the current study proposes a more comprehensive model by additionally incorporating other salient exogenous variables, renders the comparison of results between the father-in-law and mother-in-law models equivalent by including only homogeneous group of caregivers (i. e., only those housewives whose parents-in-law are both alive), and introduces standardized measurement scales for the endogenous variables. Estimation of the model in terms of maximum likelihood procedures in LISREL8 attests to a better overall performance over the previous model when judged from several criteria such as coefficient of determination, model fit statistics, proportion of significant causal paths, and measurement properties of reliability and validity for the variables. Interpretation of the findings suggests several salient theoretical implications that concern such crucial issues as the inconsistency between eldercare attitude and behavior, patterns of association among the subdimensions of eldercare, and the difference in the antecedents explaining attitude as opposed to behavior of eldercare. In particular, the finding that indicates almost no differences in the determinants between the father-in-law and mother-in-law models suggests a strong case to argue that caregiving behavior to fathers-in-law and mothers-in-law, respectively, is likely to be a uniform phenomenon sharing virtual1y the same antecedents, and that a unified single model is sufficient to account for caregiving behavior to both parties.

  • PDF

Development Study on the Prototype of Level Measurement System of Launch Vehicle Propellant Tanks (추진제 충전량 측정시스템 시제 개발 연구)

  • Shin, Dong-Sun;Han, Sang-Yeop;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.590-593
    • /
    • 2010
  • The processes of supplying propellants into propellant tanks play important roles during launch preparation of satellite launch vehicle. The total weight of launch vehicle greatly depends on the accuracy of filling quantity of propellant during launch preparation. Among propellants used for launch vehicles a cryogenic propellant such as liquid oxygen is widely adapted as an oxidizer for launch vehicles. Such cryogenic propellant usually resides in a propellant tank as two-phase fluid with liquid and gas, which needs an accurate level measurement system to detect the position of propellant surface precisely. In this paper the fabricating process of a level measurement system using capacitance type with three electrodes is analyzed. In addition, the change of electric signal according to the height of liquid is verified by testing the level measurement system under consideration. The results of tests shows as expected the linear trend of voltage according to the change of water height in a tank.

  • PDF

The New Imperialism, New Security Strategy of the U.S., and the Future of East Asia (신제국주의, 미국의 신안보전략, 그리고 동아시아의 미래)

  • Byung-Doo Choi
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.6
    • /
    • pp.887-905
    • /
    • 2003
  • In this paper, we first understand the concept of imperialism as a 'a dialectical relation between territorial and capitalistic logics of power', as suggested by Harvey, and its history with three phases, the last of which would be seen as the phase of new imperialism. Secondly, we examine the New Security Strategy of the U.S which can be seen as a reflection of the new imperialism of the U.S. with its neo-conservative Bush administration, and explain the wars in Afghanistan and Iraq as the implementation of the new imperialism. And then we take a close look on the current geopolitical situation of East Asia, especially North and South Korea, Japan and China, in terms of the new imperialist foreign policy of the Bush administration. Finally, we consider the limits of the new imperialism of the U.S. and globally emerging movements of anti-imperialism.

A Study on Generating efficiency of the Double Acting Stirling Engine/Generator (양방향 스털링엔진/발전기의 효율 특성 연구)

  • PARK, SEONGJE;KO, JUNSEOK;HONG, YONGJU;KIM, HYOBONG;YEOM, HANKIL;IN, SEHWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.1
    • /
    • pp.114-120
    • /
    • 2016
  • This paper describes generating efficiency characteristics of the double acting Stirling engine/generator for domestic small-scale CHP (Combined Heat and Power) system. In small distributed generation applications, Stirling engine has competition from fuel cell, microturbine and etc. In order to be economical in the applications, a long life with minimum maintenance is generally required. Free piston Stirling engine (FPSE) has no crank and rotating parts to generate lateral forces and require lubrication. Double acting Stirling engine/generator has one displacer and two power piston which are supported by flexure springs. Two power pistons oscillate with symmetric displacement and are connected with moving magnet type linear generators for power generation from PV work. In experiments, 1 kW class double acting free piston Stirling engine/generator is fabricated and tested. Heat is supplied to hot end of engine by the combustion of natural gas and converted to electric power by linear generators which are assembled with power pistons. The electric parameters such as voltage, current and phase are measured with for variable flow rate of fuel gas. Especially, generating efficiency of FPSE is measured with three different measurement methods. Generating efficiency of the double acting Stirling engine/alternator is about 24%.

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.

Development and Application of Pre/Post-processor to EMTP for Sequence Impedance Analysis of Underground Transmission Cables (지중 송전선로 대칭분 임피던스 해석을 위한 EMTP 전후처리기 개발과 활용)

  • Choi, Jong-Kee;Jang, Byung-Tae;An, Yong-Ho;Choi, Sang-Kyu;Lee, Myoung-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1364-1370
    • /
    • 2014
  • Power system fault analysis has been based on symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. Obtaining accurate line impedances as possible are very important for estimating fault current magnitude and setting distance relay accurately. Especially, accurate calculation of zero sequence impedance is important because most of transmission line faults are line-to-ground faults, not balanced three-phase fault. Since KEPCO has started measuring of transmission line impedance at 2005, it has been revealed that the measured and calculated line impedances are well agreed within reasonable accuracy. In case of underground transmission lines, however, large discrepancies in zero sequence impedance were observed occasionally. Since zero sequence impedance is an important input data for distance relay to locate faulted point correctly, it is urgently required to analyze, detect and consider countermeasures to the source of these discrepancies. In this paper, development of pre/post processor to ATP (Alternative Transient Program) version of EMTP (Electro-Magnetic Transient Program) for sequence impedance calculation was described. With the developed processor ATP-cable, effects of ground resistance and ECC (Earth Continuity Conductor) on sequence impedance were analyzed.

Power Monitoring System with Multiple Input Channels Using the Definition of IEEE Standard 1459-2010 (IEEE 1459-2010 규격의 정의를 이용한 다중 입력 채널을 갖는 전력 감시 시스템)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3100-3106
    • /
    • 2014
  • This paper develops power measurement system with multiple sensor input channels (voltage-8 channels and current-10 channels) that simultaneously can monitor power components for both supply and load side of power system. The hardware implementation of the proposed system is based on TMS320C42 DSP and signal processing program algorithm to calculate power components use the definition of IEEE Standard 1459-2010 related power quality. The performance of the developed system is tested by using standard ac power source device, and the test results showed that accuracy of the developed system is less than 0.2 %. Also, field test of the proposed system in the three-phase and four-wire power system was implemented. Simultaneous multiple channel measurement and analysis of power components in commercial and industrial electrical power system using the proposed system will be necessary to reduce power quality problems.