• Title/Summary/Keyword: Three-Dimensional Movement

Search Result 487, Processing Time 0.026 seconds

Finite Element Modeling and Mechanical Analysis of Orthodontics (치아교정의 역학적 해석을 의한 유한요소 모델링 및 치아의 거동해석)

  • Heo, Gyeong-Heon;Cha, Gyeong-Seok;Ju, Jin-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.907-915
    • /
    • 2000
  • The movement of teeth and initial stress associated with the treatment of orthodontics have been successfully studied using the finite element method. To reduce the effort in preprocessing of finite element analysis, we developed two types of three-dimensional finite element models based on the standard teeth model. Individual malocclusions were incorporated in the finite element The movement of teeth and initial stress associated with the treatment of orthodontics have been successfully studied using the finite element method. To reduce the effort in preprocessing of finite element analysis, we developed two types of three-dimensional finite element models based on the standard teeth model. Individual malocclusions were incorporated in the finite element models by considering the measuring factors such as angulation, crown inclination, rotation and translations. The finite element analysis for the wire activation with a T-loop arch wire was carried out. Mechanical behavior on the movement and the initial stress for the malocclusion finite element model was shown to agree with the objectives of the actual treatment. Finite element models and procedures of analysis developed in this study would be suitably utilized for the design of initial shape of the wire and determination of activation displacements.

Integrated three-dimensional digital assessment of accuracy of anterior tooth movement using clear aligners

  • Zhang, Xiao-Juan;He, Li;Guo, Hong-Ming;Tian, Jie;Bai, Yu-Xing;Li, Song
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.275-281
    • /
    • 2015
  • Objective: To assess the accuracy of anterior tooth movement using clear aligners in integrated three-dimensional digital models. Methods: Cone-beam computed tomography was performed before and after treatment with clear aligners in 32 patients. Plaster casts were laser-scanned for virtual setup and aligner fabrication. Differences in predicted and achieved root and crown positions of anterior teeth were compared on superimposed maxillofacial digital images and virtual models and analyzed by Student's t-test. Results: The mean discrepancies in maxillary and mandibular crown positions were $0.376{\pm}0.041mm$ and $0.398{\pm}0.037mm$, respectively. Maxillary and mandibular root positions differed by $2.062{\pm}0.128mm$ and $1.941{\pm}0.154mm$, respectively. Conclusions: Crowns but not roots of anterior teeth can be moved to designated positions using clear aligners, because these appliances cause tooth movement by tilting motion.

Extended Fitts' Law for Three-Dimensional Environment

  • Cha, Yeon-Joo;Myung, Ro-Hae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.861-868
    • /
    • 2010
  • This study explored an extended three-dimensional Fitts' law that is more suited for the pointing task than the conventional Fitts' law. The experiments were conducted under the manipulation of the distance to the target, size of the target, and direction of the target's location that can be described by two angles, $\theta1$ and $\theta2$. Considering the starting point as the center of coordinates, $\theta1$ is the angle between the positive z-axis and the target location and $\theta2$ is the angle between the positive y-axis and the projected target location on the x-y plane. From the experimental results, we confirmed that all four variables significantly affect the movement time. As we extended the index of difficulty of the conventional Fitts' model by incorporating $\theta1$ and $\theta2$, we established an extended Fitts' model that showed better accordance with the empirical data than the conventional Fitts' model and 3D Fitts' law of Murata and Iwase, in terms of the $r^2$ and the standard error of the residual between the measured movement time and the predicted value.

The Three Dimensional Analysis of the Upper Body's Segments of the Elderly during Walking (보행 시 노인의 상체 움직임에 대한 3차원적 분석)

  • Kim, Hee-Su;Yoon, Hee-Joong;Ryu, Ji-Seon;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.1-15
    • /
    • 2004
  • The purpose of this study was to investigate the kinematic variables of the upper part of the body for 8 elderly men during walking. For this study, kinematic data were collected using a six-camera (240Hz) Qualisys ProReflex system. The room coordinate system was right-handed and fixed in space, with righted orthogonal segment coordinate systems defined for the head, trunk, and pelvis. Based on a rigid body model, reflective marker triads were attached on the 3 segments. Three-dimensional Cartesian coordinates for each marker were determined at the time of recording using a nonlinear transformation(NLT) technique with ProReflex software (Qualisys, Inc.). Coordinate data were low-pass filtered using a fourth-order Butterworth with cutoff frequency of 6Hz. Three-dimensional angles of the head, trunk, and pelvis segment were determined using a Cardan method. On the basis of each segment angle, angle-angle plot used to estimated the movement coordinations between segments. The conclusions were as follows; (1) During the support phase of walking, the elderly people generally kept their, head the flexional and abductional posture. Particularly, the elderly displayed little internal/external rotation. (2) The elderly people showed extensional and external rotation postures in the trunk movement. Particularly, It showed the change from adduction into abduction at the heel contact event of the stance phase. (3) The elderly people showed almost same pelvis movement from the flexion into extension, from the abduction into adduction, and from internal rotation into external rotation at the mid stance and toe off of the stance phase.

Kinematic Analysis of Airborne Movement of Dismount from High Bar(I) (철봉 내리기 공중 동작의 운동학적 분석(I))

  • Choi, Ji-Young;Kim, Youg-Ee;Jin, Young-Wan
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.159-177
    • /
    • 2002
  • The purpose of this study was to investigate the relations between the segments of the body, the three dimensional anatomical angle and the angular velocity of the air born phase and understand the control mechanism of the high-bar movement, the somersault, the double somersault, the double somersault with full twist. For this study seven well trained university gymnastic volunteered, Zatsiorky and Seluyanov(1983, 1985)'s sixteen segment system anatomical model was used for this study. For the movement analysis three dimensional cinematographical method(Arial Performance Analysis System : APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 5.1 graphical profromming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and angular velocity were defined. As a result of this study 1. As the rotation of the body increased in the air born phase the projection angle of the CM of the total increased, this resulted the increased of the max hight of the CM. 2. In three dimensional angular velocity the Z axis(vertical direction) projection angular velocity increased as the rotation of the body increased in the airborn phase, but the Y axis and the X axis projection angular velocity did not show significant differences. 3. As the rotation of the body increased in the air born phase the angular movement of the shoulder and the hip showed significant change. These movement act as the starter in the preparation phase. 4. The somersault angle, the twist angle, the tilt angle of the upper body related to the global reference frame in the releas phase the average somersault angle of the three types of high-bar movement was $57.7^{\circ}$, $38.8^{\circ}$, $39.7^{\circ}$, the average tilt angle was $-1.5^{\circ}$, $-5.4^{\circ}$, $-8.4^{\circ}$, the average twist angle was $13.4^{\circ}$, $10.6^{\circ}$, $23.3^{\circ}$. This result showed that the somersault with full twist had the largest movement.

Grouping-based 3D Animation Data Compression Method (군집화 기반 3차원 애니메이션 데이터 압축 기법)

  • Choi, Young-Jin;Yeo, Du-Hwan;Klm, Hyung-Seok;Kim, Jee-In
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.461-468
    • /
    • 2008
  • The needs for visualizing interactive multimedia contents on portable devices with realistic three dimensional shapes are increasing as new ubiquitous services are coming into reality. Especially in digital fashion applications with virtual reality technologies for clothes of various forms on different avatars, it is required to provide very high quality visual models over mobile networks. Due to limited network bandwidths and memory spaces of portable devices, it is very difficult to transmit visual data effectively and render realistic appearance of three dimensional images. In this thesis, we propose a compression method to reduce three dimensional data for digital fashion applications. The three dimensional model includes animation of avatar which require very large amounts of data over time. Our proposed method utilizes temporal and spatial coherence of animation data, to reduce the amount. By grouping vertices from three dimensional models, the entire animation is represented by a movement path of a few representative vertices. The existing three dimensional model compression approaches can get benefits from the proposed method by reducing the compression sources through grouping. We expect that the proposed method to be applied not only to three dimensional garment animations but also to generic deformable objects.

  • PDF

A Study on The Comic Presentation Through Three-Dimensional Shot (입체적인 쇼트를 통한 코믹연출연구)

  • Hwang, Kil-Nam;Kim, Jae-Woong
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.91-99
    • /
    • 2008
  • When making a comic film, the comic presentation that uses stress and exaggeration is the important subject among other things. In this study we tried to investigate the comic effect using the movement of three-dimensional shot. To conduct this study, we extracted the shot manufactured through the Flow Motion of a 3D Production Program Virtual Camera and a High Speed Motion Picture Camera. The shot manufactured applying this manufacturing skill and using three-dimensional production method for the video contents efficiently made was classified into several scenes. The focus of this study is to search for the factor that makes the atmosphere of a story comic through three-dimensional production shot. According to the shot analysis, three-dimensional production method plays a role in developing more stories on space and time by visualizing stories in three dimensions, which makes the most use of the movement of camera, lens and the utilization of focus. In addition, in the presentation where many comic and exaggerated factors are provided, we used the technology that stresses a scene using the size of a shot and the lasting time and presented the method that exaggerates space using a 3D Production Program Virtual Camera and a High Speed Motion Picture Camera. By reviewing the qualitative improvement and the efficient method on making comic films through the possibility that the atmosphere of this three-dimensional shot can apply to the effect for comic presentation, we tried to approach the comic presentation.

Analysis of Performance on Asymmetric LED Lens Design Using Three-Dimensional Free-Form Surface Expression (3차원 자유곡면식을 이용한 LED 비대칭 렌즈 설계 및 성능 비교 분석)

  • Lee, Chang Soo;Lee, Soo Young;Hyun, Dong Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.3
    • /
    • pp.328-336
    • /
    • 2017
  • The exit surface of a lens is designed using a three-dimensional free-form expression in order to easily modify a curved surface. This enables the design of numerical values and mathematical things using three-dimensional free-form expression, and enhances precision because it can be fine-tuned via numerical control. The standard of "Classification of Luminaire Light Distribution" for outdoor lighting fixtures by IESNA is adopted in order to examine the correlation between three-dimensional free-form surface expression and lighting performance. The variation of light distribution type and range is analyzed using the values of maximum light intensity and 50% light intensity. The actual tolerance occurs owing to parameters such as the thickness of the lens, the distance between LEDs, and the movement of the center of the incident surface; the effects of changes in these parameters on the performance are compared and analyzed.

THREE-DIMENSIONAL CRYSTALLIZING ${\pi}$-BONDING , ${\pi}$-FAR INFRARED RAYS AND NEW SPACE ENERGY RESOURCE

  • Oh, Hung-Kuk
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.73-87
    • /
    • 1996
  • The outer-most electrons of metal atoms and the remining valence electrons of any molecular atoms make three dimensional crystallizing $\pi$-bondings. The electrons on the $\pi$-bonding orbital rotate clockwise or counter-clockwise and they then make electro-magnetic waves between atoms on the orbital because electron move between plus charged ions. The three dimensional crystallizing $\pi$-bonding orbitals are quantum-mechanically modeled by a cyclic Kronig-Penny Model and energy band structures are analyzed with their potential barrier thickness. The waves generated between plus charged ions are the particular $\pi$-far infrared rays, which have dual properties between material and electro-magnetic waves and can be measured not by modern electro-magnetic tester but biosensor such as finger's force tester. Because the $\pi$-rays can be modulated with electro-magnetic waves it can be applied for harmful electro-magnetic wave killers. Because the $\pi$-rays make new three dimensional crystallizing $\pi$-bonding orbitals in the material the food and drink can be transformed into a helpful physical constitutional property for human health. Distinction between crystalline and amorphous metals is possible because very strong crystalline $\pi$-bonding orbitals can not easily be transformed into another. The $\pi$-rays can also be applied for biofunctional diagnostics and therapy. Gravitational field is one of the electro-magnetic fields. And also magnetic field and gravitational force field make charge's movement. ($\times$ = q, : magnetic field, : force field, q: plus charge, : velocity field)

  • PDF

The effect of different micro-osteoperforation depths on the rate of orthodontic tooth movement: A single-center, single-blind, randomized clinical trial

  • Ozkan, Tugba Haliloglu;Arici, Selim
    • The korean journal of orthodontics
    • /
    • v.51 no.3
    • /
    • pp.157-165
    • /
    • 2021
  • Objective: This study aimed to identify the clinical effectiveness of two different penetration depths of micro-osteoperforations (MOPs) on the rate of orthodontic tooth movement. Methods: Twenty-four patients requiring the removal of the upper first premolar teeth were selected and randomly divided into two groups. The control group participants did not undergo MOPs. Participants in the experimental group underwent three MOPs each at 4-mm (MOP-4) and 7-mm (MOP-7) depths, which were randomly and equally performed to either the left or right side distal to the canine. The retraction amount was measured on three-dimensional digital models on the 28th day of retraction. MOP-related pain was measured using a visual analog scale (VAS). Between-group statistical differences in the VAS scores were determined using an independent t-test and those in canine retraction were determined using analysis of variance and post-hoc Tukey test. Results: No significant difference was found between the MOP-4 (1.22 ± 0.29 mm/month) and MOP-7 (1.29 ± 0.31 mm/month) groups in terms of the canine retraction rate. Moreover, both the groups demonstrated a significantly higher canine movement than the control group (0.88 ± 0.19 mm/month). MOPs did not significantly affect the mesialization of the posterior teeth (p > 0.05). Moreover, the pain scores in the MOP-4 and MOP-7 groups were similar and showed no statistically significant difference. Conclusions: Three MOPs with a depth of 4 mm can be performed as an effective method to increase the rate of tooth movement. However, three MOPs with depths of 4-7 mm does not additionally enhance tooth movement.